APC SUA3000XLI - Inverter

SUA3000XLI - Inverter APC - Free user manual and instructions

Find the device manual for free SUA3000XLI APC in PDF.

📄 19 pages English EN Download 💬 AI Question 10 questions ⚙️ Specs
Notice APC SUA3000XLI - page 3
Pick your language and provide your email: we'll send you a specifically translated version.
Product TypeUninterruptible Power Supply (UPS)
BrandAPC
ModelSUA3000XLI
Power Rating3000 VA / 2700 W
Input Voltage230 V AC nominal
Input Frequency50/60 Hz (±3 Hz auto-sensing)
Output Voltage230 V AC ±5%
TopologyLine-interactive
Number of Outlets8 (6 x IEC 320 C13, 2 x IEC 320 C19)
Battery TypeMaintenance-free sealed lead-acid
Typical Backup Time~20 min at half load, ~7 min at full load
Recharge Time3 hours typical
Dimensions (H x W x D)17.3 x 6.7 x 17.5 in (440 x 170 x 445 mm)
WeightApproximately 65 kg (143 lbs)
Input ConnectionIEC 320 C20 inlet
Output ConnectionTerminal block or IEC sockets
Management InterfacesUSB, RS-232, SmartSlot for optional network card
Operating Temperature0–40 °C
Relative Humidity0–95% non-condensing
Noise Level45 dBA at 1 m
Safety CertificationsCE, EN 62040-1, EN 62040-2
Warranty2 years (battery 2 years)

Frequently Asked Questions - SUA3000XLI APC

How do I replace the battery in the SUA3000XLI?
The battery is hot-swappable. Open the front panel, disconnect the battery connector, slide out the old battery and insert a new one. Ensure the replacement battery is APC approved (RBC43 or RBC44).
What is the typical runtime at half load?
At 50% load (1350 W), the SUA3000XLI provides approximately 20 minutes of backup time. Runtime varies with load and battery age.
Can I connect any device to this UPS?
Yes, but ensure the total load does not exceed 2700 W. The UPS has eight outlets: six IEC C13 and two IEC C19. Use power distribution units if needed.
How do I monitor the UPS status?
Connect via USB or RS-232 to a computer with APC PowerChute software. You can also install an optional network management card in the SmartSlot for remote monitoring.
What do the alarm sounds mean?
A continuous beep indicates battery low. A beep every few seconds means on-battery operation. A rapid beep alerts overload. Refer to the manual for full details.
Do I need special installation?
Install in a well-ventilated area away from heat sources. The UPS can be placed in a tower or rack orientation using the included rails. Ensure the input circuit breaker is adequate (16 A recommended).
How long does the battery last before replacement?
Battery lifespan is typically 3–5 years under normal conditions. Replace when runtime decreases significantly or the UPS indicates battery replacement.
Can this UPS handle voltage sags and surges?
Yes, the line-interactive topology corrects voltage fluctuations without switching to battery, saving power. It can boost or trim input voltage within 230 V ± nominal range.
What is the recommended maintenance?
Periodically inspect vents for dust, clean with a dry cloth. Test the UPS by disconnecting mains monthly. Replace the battery every 3-5 years. Keep firmware updated.
Is the SUA3000XLI compatible with generators?
Yes, but the generator must produce stable voltage and frequency (50/60 Hz). APC recommends a generator with <5% THD and sufficient power rating. Validate with a no-load test.

User questions about SUA3000XLI APC

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.