TS 2-1000 - Thermostat H-Tronic - Free user manual and instructions
Find the device manual for free TS 2-1000 H-Tronic in PDF.
| Product Type | Universal Temperature Switch (TSM 2100) |
| Dimensions | 160 x 80 x 60 mm |
| Power Supply | 230 V/AC, 50 Hz, 2 VA |
| Output | 4 floating relays, max. 3000 W (16 A) |
| Temperature Range | -99°C to +850°C |
| Accuracy | ≤0.5% FS ± 0.1°C |
| Resolution | 0.1°C |
| Sensor Type | Pt1000 (not included) |
| Number of Sensors | 2 (N1 and N2), both required for certain modes |
| Functions | 7 selectable modes: Thermometer N1, Thermometer N1/N2, Thermo switch N1, Thermo switch N1/N2, Temperature difference, Circulation pump control, Manual control |
| Display | Blue two-line LCD showing current temperature, setpoints, min/max, parameters |
| Alarm Output | Separate alarm relay and internal piezo beeper |
| Alarm Delay | Adjustable 0-8 hours |
| Mounting | Wall mounting, suitable for dry and clean rooms |
| IP Rating | IP20 |
| Safety Features | Sensor malfunction monitoring (short/open), relay position definable at fault, automatic return to mode on power loss |
| Calibration | Offset correction for sensor resistance and temperature (adjustable) |
| Maintenance | Maintenance-free; clean with soft lint-free cloth when disconnected |
| Warranty | 2 years from purchase |
| Compliance | CE, VDE regulations |
Frequently Asked Questions - TS 2-1000 H-Tronic
User questions about TS 2-1000 H-Tronic
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
Download the instructions for your Thermostat in PDF format for free! Find your manual TS 2-1000 - H-Tronic and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. TS 2-1000 by H-Tronic.
USER MANUAL TS 2-1000 H-Tronic
The unIVersal TemperaTure sWITch Tsm 2100 is ideal for all applications where a precise temperature control in heating or cooling is required. The unit can be used in the form of an independent monitor, as a frost guard, as a substitute for defective mechanical thermostats or as a digital thermometer. If the temperature ranges outside of the preset window, a relay will switch each channel individually after an adjustable time between 0-8 hrs. Another relay can also be connected to an alarm system. An internal beeper will also give an alarm signal if required.
FeaTures
- 7 different, freely selectable functions
- For temperature sensor Pt1000*
-Switchingtemperatureadjustable in 1°C increments - Automatic monitoring of sensor for malfunction
– Relay position definable at sensor malfunction - Temperature range: -99 ... +850°C
- Accuracy: ≤0.5% Fs ± 0.1°C
– LCD display shows programmed switching temperatures, current temperature, setting parameters and the min/max temperature - Dim.: 160 × 80 × 60 mm
Technical data
- Power supply: 230 V/AC
- 2 x Pt 1000 Temperature Sensor (Not included)
- Power consumption: 2 VA
- Output: 4 floating relays, max. 3000 W
- Resolution: 0,1°C
- IP-Protection: IP 20
* Not included. For modes 2, 4, 5, and 6 [see page 37] a second temperature sensor Pt1000 is required.
FOR yOur saFeTy
Please read this manual carefully. It contains important information for the safe operation and use of this device. The law requires that we give you important information for your safety and that we point out how to avoid damage to persons, the device and connected devices. No liabilities will be taken for damages or claims resulting out of not reading and/or not following the user guide and/or any form of modification on or in the product. Under these circumstances, no warranty services will be given. Liability will not be taken for consequential damages. These instructions are part of the device and should therefore be stored carefully. In order to avoid malfunction, damage and health problems, please follow the safety instructions carefully:
– Repairs may only be carried out by an expert.
- Dispose of the packaging material and keep it out of reach of children.
There is a danger of suffocation
Electrical devices do not belong in the hands of children.
Store the device in a safe place.

danger! This unit may only be opened or repaired by a person authorized and qualified to do so and/or who has the knowledge of electrical safety regulations. If the device is opened there is a risk of shock. Disconnect the device from the mains before opening the device.
1 designaTed use
The device is designed to switch a connected device (230 V \~ / 50 Hz, Max. 16A, 3000VA) according to a preprogrammed temperature. The temperature switching range is adjustable from -99°C to +850°C in steps of 1°C. Any other use is not permitted.
This device:
- may only be used with the current of 230 VAC/50Hz.
- may only be used in dry and clean rooms.
It may not be used in rooms with high humidity.
- may not be subjected to mechanical strain or mounted in dusty locations.
- may not be modified or reworked in any way differing from the original version.
Should these mentioned points not be followed,
then there is a danger of short-circuit and/or electrocution.
2 FeaTures
The universal Temperature Switch TSM 2100 with seven different functions is ideal for all applications where a precise temperature control in heating or cooling is required. External temperature sensors will detect temperatures from -99°C to +850°C. The programmable switching temperature can be adjusted in 1°C increments. The blue, two line LCD display shows the programmed switching temperatures, the current temperature, the setting parameters and the min/max temperature. The device is not only understandable and easy to use but also contains a number of safety features. A short-circuit within the sensor cable or a defective sensor are immediately indicated on the device. The unit can also be used in the form of an independent monitor, as a frost guard, as a substitute for defective mechanical thermostats or as a digital thermometer. In addition, the device has a separate Min/Max alarm setting. If the temperature ranges outside of the preset window, a relay will switch each channel individually after an adjustable time between 0-8 hrs. Another relay can also be connected to an alarm system. And internal beeper will also give an alarm signal if required. All parameters are adjustable.
3 general saFeTy InsTrucTIOns
- This device should not be handled or installed by persons with reduced physical, sensory or mental capabilities or lack of experience (including children) other than if supervised by a trained, responsible person.
- Children may not play with this device and should be supervised when present.
- This device may only be connected to a properly installed power socket. The voltage must match the specifications depicted on the nameplate of the unit or mentioned in this instruction manual.
- Keep the mains power cord away from sharp edges, moisture, heat or oil.
- Do not connect the device if the power cord is damaged. In order to avoid a hazard or electrocution, a damaged power cord must be replaced immediately by our service centre or a similarly qualified person.
- If the power cord is damaged unplug the device immediately and replace the power cord accordingly by our service centre or a similarly qualified person.
-
Unplug the device if it is not used over a longer period of time.
-
Keep the packing material and the plastic bags away from infants. There is a danger of suffocation.
- When installing the device, install all cables so that they do not become a tripping hazard or can accidentally be pulled out.
- When disconnecting the device from the mains, pull the plug out of the socket. Do not pull at the power cord.
4 saFeTy InsTrucTlOns
When handling electrical devices, the VDE regulations have to be applied. Especially VDE 0100, VDE 0550/0551, VDE 0700, VDE 0711 and VDE 860. - This device may not be modified in any way. The CE conformity has been declared and proven and the corresponding document is deposited with the manufacturer.
- Before opening the device, please disconnect it from the mains and/or make sure that it is not connected to an electrical current.
- Tools may only be used if the device is disconnected from the mains.
- All connecting cables should regularly be inspected for any damages on the insulation.
- Should any damages be found, disconnect the device immediately from the mains and repair or exchange it.
Should there be any open questions on the installation, the devices connected, the functions, the maintenance, the safety or any other point concerning this device, please contact a specialist or a qualified person.
Before installing and using this device, please make sure that it and the attached devices are suitable and compatible. In no event will liabilities be taken for consequential or incidental direct or indirect damages resulting from improper use or incorrect installation of the device.
This item was tested and manufactured according to EU regulations 2014/35/EU and 2004/108/EG and holds the corresponding CE approval. Any change of the circuitry or exchange of components other than specified will invalidate this approval.
malFuncTION
Only use the device if it is functioning without disturbance. If there is any malfunction, switch off the device immediately and consult a specialist. The device may only be reinstalled after it has been checked thoroughly. Signs of malfunction are if:
– The device is visibly damaged.
- The device is malfunctioning.
- Attached cables or the housing has become loose.
Repairs may only be done by a qualified person or a specialist
using original components and parts. There is the danger of electrocution.
5 mOuntIng
The installation may only be done by a qualified person who has knowledge of the current guidelines and regulations!
nOTe: Please make sure that all electricity has been switched off before starting the installation. Make sure only components are used which are either in the packing or described in this manual. This is for your safety.
- This device may only be operated in enclosed, dry areas.
- The device is designed for permanent wall mounting. A properly installed 230 V socket must be located in the near vicinity of the temperature switch. The device may only be installed by a competent person or a qualified electrician.
- If this device is installed to control a load that can cause a danger in the event of malfunction, additional safety measures are required.
- Make sure that all devices are connected according to their instruction manuals. Under certain circumstances the connection to another device (e.g. protective conductor to ground) can cause extreme surges.
- Keep the device away from spray- or rainwater, dust and direct sunlight.
- When mounted in industrial facilities, the accident prevention regulations for electrical systems and equipment of the professional associations must be followed.
- In schools, training centers, clubs and workshops the operation of modules
must be monitored by responsible, trained personnel.
- If the device needs to be repaired only genuine spare parts may be used! The use of other components may result in serious personal injury and damage.
- When the mains plug of the device is inserted into a correctly mounted, 230 V, earthed socket (connect without load), the lighting of the seven segment display signals the operational readiness of the device.
This product is designed for mounting on dry and clean walls. Make sure that this product is mounted on a stable surface.
The device is designed as a class 2 product. Please make sure that, if the connected devices are not class 2 products, the PE is connected according to VDE or applicable regulations.
LEDs:
1 LED "Relais" (Relay) is illuminated: the output relay is switched on.
2 LED "Alarm" is illuminated: the alarm relay is switched on
3 LED "Fehler" (malfunction) is illuminated: the connected sensor is missing or malfunctioning
Buttons:
1 Button "ESC": goes back one step in the menu or aborts the input mode
2 Button "OK": confirms a selected value
3 Button ▲: increases the selected value
4 Button ▼: decreases the selected value
6 CONTROL MENUS

flowchart
graph TD
A["Mode (1-8)\n1. Thermometer N1\n2. Thermometer N1 and N2\n3. Thermo switch N1\n4. Thermo switch N1 and N2\n5. Temperature difference\n6. Circulation pump control\n7. Manual control\n8. Calibrating the sensor\n9. Reset"] --> B["Mode "Thermometer N1""]
B --> C["Mode "Thermometer N1 and N2""]
C --> D["Preferences "Thermal switch N1""]
D --> E["Preferences "Thermal switch N1 and N2""]
E --> F["Preferences "Temperature difference""]
F --> G["Preferences "Circulation pump control""]
G --> H["Preferences "Manual control""]
H --> I["Calibrating the sensor"]
I --> J["Reset all"]
MAIN MENU
When the device is connected with the main power supply the main menu will automatically open the display. Depending on the chosen mode and the settings a submenu is accessible in which various parameters can be changed. Changes can be made with the buttons ▲▼ and confirmed that the button "OK". All input values and data will be stored. In the case of a power loss the device will keep the data and return to the selected mode. Changes can be made by pressing the "ESC" button.
Mode 1-9:
- Thermometer N1
- Thermometer N1 and N2*
- Thermo switch N1
- Thermo switch N1 and N2*
- Temperature difference*
- Circulation pump control*
- Manual control
- Adjustment
- Reset
*For these modes a second temperature sensor PH1000 is required.
6.1 MENU STRUCTURE/DATA INPUT
A menu can consist out of multitude of lines and is indicated has a list. Only one line is shown at a time. The other lines can be accessed by pressing the buttons ▲▼. If the value is changed, the change needs to be confirmed by pressing the button OK. If values cannot be changed, then this will be indicated in the display.
| First menu item | ↓ |
| Value N1 | ↑ |
| Value N2 | ↑ |
| ... | ↑ |
| Last menu item | ↑ |
The symbols on the previous page side of the display have the following meaning:
↓ - First menu point
↓ - Scrolling function is available
↑ - Last menu point
7 FUNCTION MODE „THERMOMETER N1“
In this mode the temperature of the thermometer module NI is measured and the value displayed. The maximum and minimum temperature can be reset by pressing a button "OK"
| Name of the mode | ↓ |
| Temperature | ↓ |
| Highest and lowest measured temperatures | ↑ |
FUNCTION MODE "THERMOMETER N1 AND N2"
In this mode the temperature of the thermometer modules N1 and N2 are measured and the value displayed. The maximum and minimum temperature can be set by pressing a button "OK"
| Name of the mode | ↓ |
| Temperature T1 and T2 | ↓ |
| Highest and lowest measured temperaturesof the external temperature sensor N1 | ↓ |
| Highest and lowest measured temperaturesof the external temperature sensor N2 | ↑ |
INPUT MODE "THERMOSSCHALTER N1" (THERMO SWITCH)
In this mode the device can be configured as a switch for heating or for cooling.
MENU "THERMOSCHALTER N1" (THERMO SWITCH N1)
In this mode the device can be programmed to be a heating or a cooling unit.
INPUT MENU "THERMO SWITCH N1"
The following menu points are displayed:
| T1 EIN (On) | ↓ |
| T1 AUS (Off) | ↑ |
| T1 Alarm Min. | ↑ |
| T1 Alarm Max | ↑ |
| T1 Alarm delay | ↑ |
| Relais Zustand bei Fehler(relay status at malfunction) | ↑ |
| Piezo | ↑ |
| Modus starten (start mode) | ↑ |
The single parameters have the following meanings:
T1 EIN (On)
In this menu you can enter a temperature at which a connected device is to be switched ON. Fist, press button OK. The value can be changed with the buttons ▲▼, now. The selection is confirmed by pressing the button "OK" and the device will move to the next menu point.
T1 AUS (Off)
In this menu you can enter a temperature at which a connected device is to be switched OFF. Press button OK. The value can now be changed with the buttons ▲▼. The selection is confirmed by pressing the button "OK" and the device will move to the next menu point.
T1 Alarm Min
In this menu you can enter a minimum temperature at which an alarm will be sounded. Press button OK. The value can now be changed with the buttons
▲▼. The selection is confirmed by pressing the button "OK" and the device will move to the next menu point.
T1 Alarm Max
In this menu you can enter a maximum temperature at which an alarm will be sounded. Press button OK. The value can now be changed with the buttons
▲▼. The selection is confirmed by pressing the button "OK" and the device will move to the next menu point.
T1 Alarm Delay
In this menu you can enter a time between 0 and 8 hours. The switching of the alarm relay N1 will be delayed by the entered time. Press button OK. The value can be changed with the buttons ▲▼ . The selection is confirmed by pressing the button "OK" and the device will move to the next menu point.
Relay Status at malfunction
In this menu you can define the action of the relay REL1 and ALARM 1 if a malfunction is detected. Options are:
-
ON
-
OFF
-
No changes to existing status.
The value can be changed with the buttons ▲▼. The selection is confirmed by pressing the button "OK" and the device will move to the next menu point.
Piezo
In this menu you can define the action of the piezo speaker if a malfunction is detected. Options are:
-
ON
-
OFF
The value can be changed with the buttons ▲▼. The selection is confirmed by pressing the button "OK" and the device will move to the next menu point.
Start mode
After all inputs have been made the mode is started by confirming this menu point.
Note N1: input values for the temperature range from -99°C to +850°C
Note N2: the input mode can be left at all times by pressing the button ESC
Note N3: if a button is not pressed the duration of 10 seconds in the programming mode, the device will automatically return to the function mode without saving the values that have already been input.
8 FUNCTION MODE "HEATING" AND "COOLING"
The relay ALARM is switched ON if the measured temperature is higher or equal to T ALARM Max or lower or equal to T ALARM Min. The relay ALARM is switched OFF if the measured temperature is higher than T ALARM Min or lower than T ALARM Max.
8.1 FUNCTION MODE "HEATING"
The function "Heating" is active if the programmed switching ON temperature is lower than the switching OFF temperature.
The relay is switched OFF if the measured temperature is equal or higher than T OFF.
The relay is switched ON if the measured temperature is lower or equal to T EIN.
The relay ALARM is switched ON if the measured temperature is higher or equal to T ALARM Max or lower or equal to T ALARM Min.
8.2 FUNCTION MODE „COOLING“
The function "Cooling" is active if the programmed switching ON temperature is higher than the switching OFF temperature.
The relay is switched ON if the measured temperature is equal or higher than T EIN.
The relay is switched OFF if the measured temperature is lower or equal to T AUS.
The relay ALARM is switched ON if the measured temperature is higher or equal to T ALARM Max or lower or equal to T ALARM Min.
Note: if the programmed switching ON and switching OFF temperatures are identical then the device will execute the function "Thermometer". The relays REL and ALARM not switched.
An example for the functions "Heating" and "Cooling"
Example HEATING: you have a heating system which you would like to run as a temperature of 21°C with a hysteresis of +2°C. The input values would be as follows: switching ON value T1 EIN = 21°C and switching OFF value T1 AUS = 23°C. If the temperature reaches or drops beneath 21°C, the relay will switch the heating on. At 23° the relay will switch the heating off.
Example COOLING: you have a cooling system which you would like to run as a temperature of 21°C with a hysteresis of +2°C. The input values would be as follows: switching ON value T1 EIN = 23°C and switching OFF value T1 AUS = 21°C. If the temperature reaches or drops beneath 23 °C, the relay will switch the cooling on. At 21 °C the relay will switch the cooling off.

line
HEATING | Time Point | Temperature (°C) | | :--- | :--- | | switch-ON-point | 23 | | switch-OFF-point | 21 |
line
COOLING | Time Point | Temperature (°C) | | :--- | :--- | | switch-ON-point | 23 | | switch-OFF-point | A21 |9 FUNCTION MODE "THERMOSCHALTER N1" (THERMO-SWITCH)
The following menu points are shown in this mode:
| Name of the mode ↓ | |
| Function) ↑ | |
| Temperature T1 ↓ | |
| T1 Min/Max ↑ | |
| T1 ON ↑ | |
| T1 OFF ↑ | |
| T1 Alarm Min. ↑ | |
| T1 Alarm Max ↓ | |
| T1 Alarm delay ↑ | |
| T1 Alarm timer ↑ | |
| Relay status at malfunction ↑ | |
| Piezo ↑ |
The single parameters have the following meaning:
Function
This menu point shows the function mode in reference to the input values under the parameters T EIN and TAUS. They can be as follows:
- Heizen (heating)
- Kühlen (cooling)
- Thermometer
Temperature T1
In this menu the temperature measured at the sensor T1 is displayed.
T1 Min/Max
In this menu the maximum and minimum temperature measured at the sensor T1 is displayed.
T1 Alarm Timer
In this menu on the value of the alarm delay is displayed.
All other parameters have the same meaning as in the menus mentioned before. Every menu point can be changed.
MODE "THERMOSCHALTER N1 / N2" (THERMO SWITCH N1/N2)
In this mode both external temperature sensors are used at the same time. The settings and the functional use are similar to the mode "Thermoschalter N1".
MODE "TEMP.-DIFF."
In this mode the device can be set as the temperature switch, allowing you to control external devices such as solar panels. The temperature of the solar panel and the temperature of the hot water storage tank are measured resulting in a temperature difference. If the outputs of the temperature switch are connected to circulation pumps, then the pumps can be started and stopped as soon as temperature differences in the solar system occur.
INPUT MENU "TEMP.-DIFF."
The following menu points are displayed:
| Differenz (Difference) | ↓ |
| Hysterese ↑ | |
| T1 EIN (min) ↓ | |
| T2 EIN (max) ↑ | |
| T1 Alarm Min. ↑ | |
| T1 Alarm Max ↑ | |
| T1 Alarm delay ↑ | |
| T2 Alarm Min. ↑ | |
| T2 Alarm Max ↑ | |
| T2 Alarm delay ↓ |
| Relay satus at malfunction ↑ |
| Piezo ↓ |
| Start mode ↑ |
The parameters have the following meanings:
Difference
Defines the temperature difference between T1 and T2 at which the relay REL1 should be switched ON. Value range: 1–30°C
Hysteresis
The hysteresis for the temperature difference value. Value range: 1–20°C
T1 Ein (min)
Minimum temperature value for the solar panel.
T1 Ein (max)
Maximal temperature value for the hot water storage tank
All other parameters have the same meaning as in the menus mentioned before [Thermoschalter T1]. Every menu point can be changed.
Programming and resulting action of REL1:
Relay 1 will switch ON if:
T 1 ≥ T 1 Ein (Min) and T 1 ≥ | T 2 + Difference |
Relay 1 will switch OFF if:
T 1 lt; (T 2 + Difference Hysteresis ) or T 1 lt; (T 1 Ein | Min | - Hysteresis
Example N1:
Set difference =5; Hysteresis = 2; T1 Ein (min) =1.5; T2 Ein (max) =70; Measured: T2=20
Relay ON T1 = 2 5
Relay OFF T1 = 2 3
Example N2:
Set difference = 5; Hysteresis = 2; T1 Ein (min) = 30; T2 Ein (max) = 70; Measured: T2=20
Relay ON T1 = 30
Relay OFF T1 = 28
Programming and resulting action of REL2:
Relay 2 will switch ON if T2 ≥ T2 Ein (max)
Relay 2 will switch OFF if T2 ≤ (T2 Ein (max) - hysteresis)
Set difference =5; Hysteresis = 2; T1 Ein (min) =20; T2 Ein (max) =70
Relay 2 ON T2 = 70
Relay 2 OFF T2 = 68
10 INPUT MODE "TEMP.-DIFF."
The following menu points are shown in this mode:
| Name of the mode | ↓ |
| Temperature T1 and T2 | ↓ |
| dT (T1-T2) | ↓ |
| Differenz | ↓ |
| Hysterese | ↓ |
| T1 EIN (min) | ↓ |
| T2 EIN | ↓ |
| T1 Min/Max | ↓ |
| T2 Min/Max | ↓ |
| T1 Alarm Min. | ↓ |
| T1 Alarm Max | ↓ |
| T1 Alarm delay | ↓ |
| T1 Alarm timer | ↓ |
| T2 Alarm Min. | ↑ |
| T2 Alarm Max | ↑ |
| T2 Alarm delay | ↓ |
| T2 Alarm timer | ↓ |
| Relay status at malf | |
| Piezo | ↑ |
The parameters have the following meanings:
Temperature T1 and T2
In this menu the temperature measured at the sensor T1 and the sensor T2 is displayed.
dT (T1-T2)
In this menu the measured temperature difference at the sensor T1 and the sensor T2 is displayed.
T1 Min/Max
In this menu the highest and lowest measured temperature at the sensor T1 is displayed.
T2 Min/Max
In this menu the highest and lowest measured temperature at the sensor T2 is displayed.
T1 Alarm Timer
In this menu the alarm delay time of the sensor T1 is displayed.
T2 Alarm Timer
In this menu the alarm delay time of the sensor T2 is displayed.
All other parameters have the same meaning as in the menus mentioned before. Every menu point can be changed.
11 INPUT MODE "ZIRKO-KONTROLL" (CONTROLLING THE CIRCULATION PUMPS)
In this mode the device can be configured as an energy saving controller for a circulation pump in hot water and heating systems. To do this the temperature sensors are mounted onto the inflow and outflow pipes. The measured temperature difference between inflow and outflow can be used to control a circulation pump.
MODE MENU "ZIRKO-KONTROLL"
This menu will display the following points:
| Name of the mode | ↓ |
| Temperature T1 and T2 ↓ | |
| dT [T1-T2] ↓ | |
| Differenz ↓ | |
| Hysterese ↓ | |
| Valve interval | ↑ |
| Interval Timer | ↑ |
| Pump running time | ↑ |
| Running time Timer | ↑ |
| T1 Min./Max. | ↑ |
| T2 Min./Max. | ↑ |
| T1 Alarm Min | ↑ |
| T1 Alarm Max | ↑ |
| T1 Alarm delay | ↑ |
| T1 Alarm Timer ↑ | |
| T2 Alarm Min | ↑ |
| T2 Alarm Max | ↑ |
| T2 Alarm delay | ↑ |
T2 Alarm Timer ↑
Relay status at malfunction ↑
Piezo ↑
The parameters have the following meanings:
Temperature T1 and T2
In this menu the temperature measured at the sensor T1 and the sensor T2 is displayed.
dT (T1-T2)
In this menu the measured temperature difference at the sensor T1 and the sensor T2 is displayed.
Interval-Timer
This menu shows the pump interval time value.
Laufzeit Timer
This menu shows the running time of the pump.
T1 Min/Max
In this menu the highest and lowest measured temperature at the sensor T1 is displayed.
T2 Min/Max
In this menu the highest and lowest measured temperature at the sensor T2 is displayed.
T1 Alarm Timer
In this menu the alarm delay time of the sensor T1 is displayed.
T2 Alarm Timer
In this menu the alarm delay time of the sensor T2 is displayed.
All other parameters have the same meaning as in the menus mentioned before. Every menu point can be changed.
12 MODE "MANUELL" (MANUAL)
In this mode all for relays (|REL1, REL2, ALARM1, ALARM2) can be switched manually on and off.
INPUT MODE "MANUELL"
The following menu points are shown in this mode:
| Relay 1 | ↓ | |
| Relay 2 | ↑ | |
| Relay Alarm 1 | ↑ | |
| Relay Alarm 2 | ↑ | |
| Start Mode | ↑ |
The status of the relay can be set by using the buttons ▲▼ The mode is started by confirming the menu point "Start Mode".
MODE MENU "MANUELL" (MANUAL)
The following menu points are shown in this mode:
| Name of the mode | ↓ |
| Relay 1 ↓ | |
| Relay 2 ↓ | |
| Relay Alarm 1 ↑ | |
| Relay Alarm 2 ↑ |
13 MODE "SENSORABGLEICH" (CALIBRATING THE SENSOR)
This menu allows the calibration of the sensors and the connecting cables to the sensors.
| Sensor 1 R-Offset | ↓ |
| Sensor 1 T-Offset ↑ | |
| Sensor 2 R-Offset ↑ | |
| Sensor 2 T-Offset ↑ |
The parameters have the following meanings:
Sensor 1 R-Offset:
This input allows the offset correction of the resistance within the wire leading to sensor 1.
Adjustable value: 0 - 50Ω
Sensor 1 T-Offset:
This input allows the offset correction for sensor 1. This value is added/deducted from the shown temperature value T1.
Adjustable value: -50ircC to +50ircC
Sensor 2 R-Offset:
This input allows the offset correction of the resistance within the wire leading to sensor 2.
Adjustable value: 0 - 500
Sensor 2 T-Offset:
This input allows the offset correction for sensor 2. This value is added/deducted from the shown temperature value T2. Adjustable value: -50ircC to +50ircC
14 MODE "ZURÜCKSETZEN" (RESET)
In this mode all input parameters can be reset to factory settings.
15 ERROR MESSAGES
The device can show the following messages:
Error N1

Err 1 shows that a short-circuit has been detected in the thermometer sensor or that the measured value is below -99°C.
Error N2

Err 2 shows that a thermometer sensor is not connected or that the measured temperature is higher than 850°C.
Error N3

Err 3 shows that the data coming from the thermometers sensor is corrupted.
Note: if an error occurs all relays are set to OFF.
16 MAINTENANCE
The device is basically maintenance free. All sensors should be checked at regular intervals for dirt or corrosion and consequently be cleaned. The full function of the device can be guaranteed, if the device and the sensors are serviced and activated at regular intervals.
CLEANING
Clean the device the soft lint free cloth. The cloth may be dampened slightly if the device is very dirty. To clean the device, make sure that it is disconnected from the mains
MALFUNCTION
Only use the device if it is functioning without disturbance. If there is any malfunction, switch off the device immediately and consults a specialist. The device may only be reinstalled after it has been checked thoroughly. Signs of malfunction are if:
- The device is visibly damaged.
- The device is malfunctioning.
- Attached cables or the housing has come loose.
Repairs may only be done by a qualified person or a specialist using original components and parts. There is the danger of electrocution.
ENVIRONMENTAL NOTES

Consumers are legally obligated and responsible for the proper disposal of electronic and electrical devices by returning them to collecting sites designated for the recycling of electrical and electronic equipment waste. This device and/or components within the device
can be recycled. For more information concerning disposal sites, please contact your local authority or waste management company.
17 WARRANTY
The dealer/manufacturer from which you have purchased this device gives a guarantee for material and function of the device for two years. Should functional defect occur, then the dealer/manufacturer has the right to repair or exchange the device. All exchanged devices are property of the dealer/manufacturer. The customer is committed to indicating any defects immediately together with the purchasing invoice.
The dealer/manufacturer cannot be made liable for defects or malfunctions that occur due to incorrect handling, incorrect mounting, incorrect assembly, the use of non-authorized components or unauthorized changes applied to the device. He can also not be made liable if the instruction manual has not been read and followed. In this case also all rights for guarantee will be void.
The dealer/manufacturer cannot be made liable for any costs and risks occurring through transport, mounting, assembly or any consequential repairs and/or costs.
The guarantee is void and the device will be returned to you at your cost if:
- Changes have been made to the device.
– Unauthorized repairs have been made to the device. - The layout has been changed without consulting the manufacturer.
- Original components have not been used.
- The instruction manual has not been followed.
- The device has been subjected to overload for power surge.
- The device has been connected to an incorrect power source.
- Incorrect and negligent handling.
This manual is a publication of HTRONIC GmbH, Industriegebiet Dienhof 11, 92242 Hirschau, Germany. All rights including translation reserved. Information provided in this manual may not be copied, transferred or put in storage systems without the express written consent of the publisher. Reprinting, also for parts only, is prohibited. This manual is according to the technical data when printed. This manual is according to the technical status at the time of printing and is a constituent part of the device. Changes in technique, equipment and design reserved. © Copyright 2014 by HTRONIC GmbH