Product TypeGas Fireplace
BrandEscea
ModelEK1550
Dimensions (HxWxD)580 x 600 x 250 mm
Weight22 kg
Power Input15 kW (gas)
Efficiency78%
Heating AreaUp to 150 m²
Fuel TypeNatural Gas or LPG
Flue TypeBalanced flue
ControlRemote control included
Glass TypeTempered ceramic glass
MaintenanceClean glass with soft cloth; annual service recommended
Safety FeaturesFlame failure device, overheat protection
Warranty2 years parts and labor
InstallationMust be installed by certified professional
Spare PartsAvailable through Escea authorized dealers

Frequently Asked Questions - EK1550 Escea

What type of gas does the EK1550 use?
The EK1550 can be configured for natural gas or LPG. Check the manual for conversion instructions.
How do I clean the glass on my Escea fireplace?
Use a soft cloth and a mild glass cleaner. Avoid abrasive materials to prevent scratching the ceramic glass.
Can I install the EK1550 myself?
No, installation must be carried out by a certified professional to ensure safety and compliance with local regulations.
How often should I service the EK1550?
It is recommended to have an annual service by a qualified technician to maintain optimal performance and safety.
Does the EK1550 have a remote control?
Yes, it comes with a remote control for easy operation. Batteries are included.
What is the warranty on the EK1550?
Escea offers a 2-year warranty on parts and labor from the date of purchase.
How do I turn off the pilot light?
Refer to the manual for specific instructions. Generally, you can turn off the gas supply or use the remote to switch to off mode.
The fireplace won't ignite. What should I check?
Ensure the gas supply is on, the remote has batteries, and the flame failure device is not triggered. If persistent, contact a service technician.
Can I use the EK1550 without a flue?
No, this model requires a balanced flue system for safe exhaust. It must be installed as per the manual.
Where can I find spare parts for the EK1550?
Spare parts are available through Escea authorized dealers or by contacting Escea customer support.

User questions about EK1550 Escea

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Heating in PDF format for free! Find your manual EK1550 - Escea and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. EK1550 by Escea.

USER MANUAL EK1550 Escea

Installation Instructions and User Guide

EK Series

Escea Fireplace Kitchen

WARNING

THE APPLIANCE & FLUE SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH:

• AS/NZS 2918

• THIS INSTALLATION INSTRUCTION BOOKLET

• LOCAL / NATIONAL BUILDING CODES

• ANY OTHER RELEVANT STATUTORY REGULATIONS

LEAVE THESE INSTRUCTIONS WITH THE END USER.

Warranty Repair and Annual Servicing

Warranty repair work must be carried out by a suitably qualified person.

Any shortcomings in the appliance and flue installation will be the responsibility of the installer. Escea will not be accountable for any such failings or their consequences.

Manufactured by: Escea Ltd, PO Box 5277 Dunedin NZ, Ph: +64 3 478 8220

For contact details of your local Escea distributor or dealer, please visit www.escea.com, call 0800173000, or email us at info@escea.com.

From Australia, please visit www.escea.com.au, call AU: 1800 460 832 or WA: 1800 730 140, or email us at info@escea.com

WARNING

FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN DEATH, SERIOUS BODILY INJURY, AND/OR PROPERTY DAMAGE. FAILURE TO FOLLOW THESE INSTRUCTIONS MAY ALSO VOID YOUR FIRE INSURANCE AND/OR WARRANTY.

MAINTAIN AND OPERATE THE FIREPLACE IN ACCORDANCE WITH THESE INSTRUCTIONS.

DO NOT USE FLAMMABLE LIQUIDS OR AEROSOLS TO START OR REKINDLE A FIRE.

DO NOT PLACE ANY COMBUSTIBLES IN FRONT OF THE FIRE AS SOME FIREWOOD MAY SPIT SPARKS.

DO NOT TOUCH THE SURFACES AS THEY CAN BE VERY HOT EVEN AFTER THE FIRE HAS BURNT OUT.

ENSURE CORRECT INSTALLATION AS PER THESE INSTRUCTIONS.

DO NOT MODIFY THE FIRE.

DO NOT OPERATE THE FIRE WITHOUT THE FLUE SYSTEM.

YOUNG CHILDREN SHOULD BE CAREFULLY SUPERVISED WHEN THEY ARE IN THE SAME AREA AS THE COOKING FIRE.

TODDLERS, YOUNG CHILDREN, AND OTHERS MAY BE SUSCEPTIBLE TO ACCIDENTAL CONTACT BURNS AND MUST NOT OPERATE THE COOKING FIRE. A PHYSICAL BARRIER IS RECOMMENDED IF THERE ARE “AT RISK” INDIVIDUALS IN THE VICINITY. TO RESTRICT ACCESS TO A FIREPLACE OR STOVE, INSTALL AN ADJUSTABLE SAFETY GATE TO KEEP TODDLERS, YOUNG CHILDREN, AND OTHER “AT RISK” INDIVIDUALS OUT OF THE AREA AND AWAY FROM HOT SURFACES.

TAKE CARE WHEN INSTALLING TO PREVENT INJURY AS THIS PRODUCT IS HEAVY.

ALWAYS WEAR THE GLOVES PROVIDED WHEN OPERATING THE APPLIANCE.

IMPROPER DISPOSAL OF ASHES MAY RESULT IN FIRES.

CRACKED, BROKEN, EXTENSIVELY CORRODED OR BUCKLED COMPONENTS MAY RENDER THE INSTALLATION UNSAFE.

DO NOT OVER FIRE THE APPLIANCE - FOLLOW FIRE LOADING GUIDELINES.

DO NOT STORE CHEMICALS OR FLAMMABLE MATERIALS NEAR THIS APPLIANCE.

DO NOT SPRAY AEROSOLS NEAR THIS APPLIANCE.

A Installation Process and Product Details 5

A1 Product Description 5
A2 Product Dimensions 5

B External Clearances to Combustible Surfaces 8

C Platform Minimum Requirements 9

D Concrete/ Block Structure Installation 10

D1 Minimum Requirements of Concrete/ Block Structure 10
D2 Sealing Requirements 11
D3 Concrete/ Block Structure Flue System Installation 12

E Timber/ Combustible Structure Installation 13

E1 Minimum Requirements of the Timber/ Combustible Structure 13
E2 Sealing Requirement 14
E3 Autoclaved Aerated Concrete (AAC) Heat Cell Assembly 15
E4 Timber/ Combustible Structure Flue System Installation 20

F Assembling and Installing the Fireplace 22

F1 Gather Installation 22
F2 Securing the Base of the Appliance 23
F3 Assembling the Fireplace 24
F4 Attaching and Removing the Pivot Drawer 25
F5 Using the Weather Cover (Optional Accessory) 26

G Burning Guide 27

G1 Fuel Selection 27
G2 Starting the Fire 27
G3 Loading the Fire 27
G4 Extinguishing the Fire 27

H Cooking Guide 28

H1 Cast Iron Instructions 28
H2 Storage 28
H3 Optimal Ember Generation 28
H4 Cooking on the Fire 29

I Maintenance 31

11 Chimney Maintenance 31
12 Recommended Refurbishment Products 31

J General Warranty Terms and Conditions 32

A1 Product Description

The EK series is an outdoor cooking wood fire with the ability to seamlessly transform from a cooking appliance into a fireplace for entertainment. It is designed for outdoor use ONLY.

A2 Product Dimensions

The EK series consists of three different sizes of fireplace: the EK950, the EK1250, and the EK1550. Dimensions for each fireplace can be found on the next pages.

For more detail, view architectural drawings at www.escea.com or www.escea.com.au.

EK950

Escea EK1550 - A2 Product Dimensions - 1

natural_image Isometric line drawing of a mechanical or architectural component with labeled dimensions H, W, and D (no text or symbols beyond labels)

948 920 997 188

Flue: Ø350 OD

530 375 120 14 666 14 638 137 50 1423 1543

EK950 Specifications
Appliance Dimensions(mm): 977W x 1543H x 655D
Appliance Weight(kg): 300
Concrete or Concrete Block Structure
Minimum Cavity Dimensions without 140mm concrete(mm): 1077W x 835D
Minimum Cavity Dimensions with 140mm concrete(mm): 1357W x 1050D
Timber or Combustible Structure
Minimum AAC Heat Cell Dimensions(mm):1260W x 1700H x 896D
Minimum Cavity Dimensions(mm):1320W x 1800H x 930D

Note: For Concrete or Concrete Block Structure Height dimension refer to section D1.

EK1250

Escea EK1550 - A2 Product Dimensions - 5

EK1250 Specifications
Appliance Dimensions(mm): 1296W x 1543H x 655D
Appliance Weight(kg): 380
Concrete or Concrete Block Structure
Minimum Cavity Dimensions without 140mm concrete(mm): 1376W x 835D
Minimum Cavity Dimensions with 140mm concrete(mm): 1656W x 1050D
Timber or Combustible Structure
Minimum AAC Heat Cell Dimensions(mm): 1560W x 1700H x 896D
Minimum Cavity Dimensions(mm): 1620W x 1800H x 930D

Note: For Concrete or Concrete Block Structure Height dimension refer to section D1.

Note: The EK1550 requires two flues to function properly - this is mandatory.

Escea EK1550 - A2 Product Dimensions - 6

natural_image Technical line drawing of a mechanical housing or enclosure with labeled dimensions H, D, and W (no text or symbols beyond labels)

1547 1519 355355 1596 188

Flue: Ø350 OD Flue: Ø350 OD

530 375 501423 120 14 666 638137 14 1543

EK1550 Specifications
Appliance Dimensions(mm): 1596W x 1543H x 655D
Appliance Weight(kg): 450
Concrete or Concrete Block Structure
Minimum Cavity Dimensions without 140mm concrete(mm): 1676W x 835D
Minimum Cavity Dimensions with 140mm concrete(mm): 1956W x 1050D
Timber or Combustible Structure
Minimum AAC Heat Cell Dimensions(mm):1860W x 1700H x 896D
Minimum Cavity Dimensions(mm):1920W x 1800H x 930D

Note: For Concrete or Concrete Block Structure Height dimension refer to section D1.

B

External Clearances to Combustible Surfaces

Note: The cavity structure must comply with the relevant section section “D1 Minimum Requirements of Concrete | Concrete Block Structure” on page 10 or section “E1 Minimum Requirements of the Timber | Combustible Structure” on page 13, depending on the installation method of choice.

SIDE VIEW Any heat sensitive roofing/ ceiling material EK950 and EK 1250: 850mm min EK1550: 1500mm min Appliance opening 2000mm min Heat resistant floor protector required. It must extend 300mm away from the appliance opening and cover the entire width of the opening plus 200mm on each side, if a heat sensitive flooring is used. If the opening is to be installed lower than 790mm the entire floor must be heat resistant. Platform 790mm min Floor Any heat-sensitive material

TOP VIEW Appliance opening Heat-sensitive material sidewall EK950 and EK 1250: 650mm min EK1550: 1000mm min

Escea EK1550 - External Clearances to Combustible Surfaces - 3

Platform Minimum Requirements

The platform must be installed at a height to satisfy the requirements listed in section "B Clearances to Combustible Surfaces" on page 8.

If the platform is to be constructed of combustible material, the platform must be insulated from the appliance. The insulation requirement depends on the installation method of choice, as follows:

If the appliance is installed into a poured concrete | concrete block structure:

The perimeter of the platform must be insulated from the appliance using either:

• Calcium silicate board (eg. 9mm Promina)
- AAC material of thickness no less than 75mm and having a minimum thermal resistance/ R-value of no less than 0.59m^2.K / W
• Concrete of a thickness no less than 140mm.

If the appliance is installed into a timber | combustible structure:

The platform must be insulated from the appliance using the required base of the AAC heat cell. See section "E3 Autoclaved Aerated Concrete (AAC) Heat Cell Assembly" on page 15 for details.

View looking down through cavity from above
The platform must not inhibit airflow through the vents to the cavity Platform Appliance opening The platform must be suitable to support the appliance, flue system and any other additional weight placed on it

D1 Minimum Requirements of Concrete | Concrete Block Structure

This appliance is designed for outdoor use ONLY.

If the appliance is installed into a concrete block or poured concrete structure, and the structure forms part of a building, then the entire appliance must be fully enclosed in concrete material of thickness 140mm or greater. Cladding over the concrete structure can consist of any heat resistant material.

When the appliance is installed in a remote, freestanding structure that is not attached to or encompassed within the envelope of the building and is at least 2000mm from any combustible material in any direction, then the enclosure may be constructed from any heat resistant material. If any combustible material is within 2000mm of the fire in any direction, then the enclosure must comply with the concrete structure specified below.

Appliance Minimum Clearances for 140mm thick Concrete Structure

Note: If installing into a heat resistant material other than concrete, or if concrete thickness is less than 140mm- minimum clearance of 2000mm to any heat sensitive material applies.

SECTION A-A 40 40 50 180 Appliance 50mm min side(s) and back clearance to any heat sensitive material, at any height External clearances apply if material extends beyond front of cavity (see Section B) 75 min to full height below flashing Front recess: 400 Concrete required Concrete structure MUST continue through roof line Poured concrete or concrete block structure- 140mm thickness Any combustible material Appliance A A Platform Platform insulation if required (see section C) Minimum 4.6m from top of platform to flue exit

Venting Minimum Requirements for Concrete Structure

The air vent(s) can be any size or shape, provided that the total combined open surface area is at least 28000 mm^2 (eg. 2x 75mm dia vents).

Vents are necessary in the structure, not higher than 300mm above the base of the fire. Vents must take air from outside. Venting air exits the structure through the flashing cone (supplied in Escea flue kit).

Note: The EK1250 |EK950 are shown as an example; the EK1550 requires two flues.

Appliance Opening 300mm A total open surface area of greater than 00mm no 280 higher than 300mm from the base of the appliance to vent the cavity

D2 Sealing Requirements

All joints in the flue system and between the gather | chassis should be sealed with a suitable high temperature fire cement sealant | cement that is able to operate at temperatures greater than 500°C.

D3 Concrete | Concrete Block Structure Flue System Installation

Flue Specifications

Note: The EK1550 will require two of each item shown below (two flue terminals, two cones, etc.). The EK1250 and EK950 require one of each item shown below.

Flue terminal (supplied with flue kit) Cone 350mm to 650mm (supplied with flue kit) Spider 350mm to 650mm (supplied with flue kit). Flashing liner 550mm (installation dependent, not supplied)- flashing must comply with relevant building code Supported heat resistant chimney cap with 550mm spigot (installation dependent, not supplied) Flue liner 450mm (2x supplied with flue kit) Flue 350mm (2x supplied with flue kit) Gather Top Entire cavity concrete/concrete block Gather Top

NOTE: THE APPLIANCE & FLUE SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH AS/NZS 2918 AND THESE SPECIFICATIONS.

Flue Installation- Order of Operations

  1. Install first length of flue, crimp down to fit into firebox spigot
  2. Install first length of liner, crimp up. Liner fits onto tabs welded to firebox gather
  3. Repeat steps 1 and 2 with remaining flue(s) and liner(s)
  4. Complete flashing of structure
  5. Attach spider to final length of flue, such that it spaces off liners appropriately
  6. Fit flashing cone
  7. Fit cowl

Note: repeat the above process for the EK 1550 (as it has two flue pipes)

AS/NZS 2918 external requirements of flue termination to adjacent structures apply Flashing to comply with relevant building code Supported heat resistant chimney cap Concrete structure MUST continue through roof line Any heat sensitive roofing or ceiling material 50 50

E

Timber | Combustible Structure Installation

E1 Minimum Requirements of the Timber | Combustible Structure

This appliance is designed for outdoor use ONLY.

If installing into a timber/combustible structure, and the appliance forms part of a building or is part of a freestanding structure, the following minimum clearances to combustible materials must be adhered to. Furthermore, the appliance MUST be installed with an Autoclaved Aerated Concrete (AAC) heat cell consisting of panels no less than 75mm thick and having a thermal resistance/ R-value of no less than 0.59m ^2 .K/W. The ‘heat cell dropbox’ must be installed with the heat cell to comply. For minimum requirements of the heat cell see “Autoclaved Aerated Concrete (AAC) Heat Cell Assembly” on page 15.

Any cladding over the front of the structure (not including the chimney chase structure) must consist of a heat resistant material. Cladding over any other surface of the structure can consist of a combustible material (eg. plywood).

Appliance Minimum Clearances for Timber | Combustible Structure
TOP VIEW 30 30 34 Timber framing FRONT VIEW SIDE VIEW 380 50 100 Timber framing Chimney chase AAC Heat Cell Appliance 30 30 50 34 451.7

Venting Minimum Requirements for Timber | Combustible Structure

The air vent(s) can be any size or shape, provided that the total combined open surface area is at least 35,300 mm ^2 (eg. 2x 150mm dia vents).

For the EK 1550:

The air vent(s) can be any size or shape, provided that the total combined open surface area is at least 70,600 mm ^2 (eg. 4x 150mm dia vents)

Vents are necessary in the structure, not higher than 300mm above the base of the fire. Vents must take air from outside. Venting air exits through the flashing cone (supplied in Escea flue kit).

Note: The EK1250/EK950 are shown as an example; the EK1550 requires two flues.

Venting Requirements: EK 950/ EK 1250: A total surface area of no less than 35,300mm² EK 1550: A total surface area of no less than 70,600mm² Vents location no higher than 300mmabove the base of the appliance. Vents must take external/ outside air. If venting into a building cavity, ensure building cavity is balanced with outside air. Vents can be in sides, at back or at front of cavity. Symmetry in venting orientation preferred. 300mm MAX Appliance Platform

E2 Sealing Requirement

All joints in the flue system and between the gather / chassis should be sealed with a suitable high temperature fire cement sealant / cement that is able to operate at temperatures greater than 500°C.

Care should be taken to ensure that the cavity is weatherproof.

E3 Autoclaved Aerated Concrete (AAC) Heat Cell Assembly

Minimum Requirements of the Heat Cell

The AAC heat cell MUST be constructed around the appliance if installing into a timber/ combustible structure. AAC panels MUST be at least 75mm thick and must gave a thermal resistance/ R-value of no less than 0.59m ^2 .K/W. The base of the heat cell must be constructed to the minimum dimensions prescribed to insulate the platform from the appliance. The ‘heat cell dropbox’ (supplied separately) MUST be installed with the heat cell to comply.

There should be a recess from the front of the heat cell to the front of the fire of no less than 35mm.

For the EK 950 and EK 1250, vents should be cut at the base of the heat cell, either in the sides or back panel, with an area of no less than 24,000mm^2 . For the EK 1550, the venting area must be no less than 48,000mm^2 . Note: the venting requirement for the heat cell is different from the structure venting requirements.

Note: Heat cell assemblies in this manual represent the minimum dimensions and are a guide only. The models have a 35mm recess to the front of the fire.

Heat Cell Construction Recommendations

Heat cell panels should be screwed together and bonded with a certified mortar (recommended by manufacturer) to ensure a tight seal.

The models shown in this document have a 5mm clearance from the AAC material to the firebox front flange, which should be altered depending on the chosen finishing method for the heat cell. Follow manufacturer's recommendations regarding finishing of the AAC material.

Note: To prevent the heat cell from cracking, it is recommended to light a few small fires first to dry out the AAC material.

EK 950 Heat Cell Dimensions
TOP VIEW 340 580 340 Top 3 896 503 Top 1 Top 4 Top 2

1x Heat cell dropbox required with EK 950 AAC heat cell

FRONT VIEW 157 600 1700 676 117 Front Panel 1 Front Panel 2 Front Panel 3 Front Panel 4 Front Panel 5 Base 1 Basel 2 Base 3 1260

SIDE VIEW BACK V Side Panels 3/6 157 Side Panels 2/5 Side Panels 1/4 896

3506060600 Back Panel 1 Back Panel 2 Back Panel 3 110 110 110 Vents required

EK 1250 Heat Cell Dimensions
Escea EK1550 - Heat Cell Construction Recommendations - 6
1x heat cell dropbox required with EK 1250 AAC heat cell

EK 1550 Heat Cell Dimensions
TOP VIEW 285 580 130 580 285 Top 3 Top 6 Top 1 Top 7 503 Top 2 Top 4 Top 5 710

FRONT VIEW 157 Front Panel 1 600 Front Panel 2 1700 676 Front Panel 3 117 Front Panel 4 Front Panel 5 Base 1 Base 2 Base 3 Base 4 1860

2x heat cell dropboxes required with EK 1550 AAC heat cell W BACK VIEW

SIDE VIEW Side Panels 3/6 157 Side Panels 2/5 Side Panels 1/4 896

Back Panel 1 Back Panel 2 Back Panel 3 Vents required 155 155 155

EK 950 Heat Cell Cut Pattern

Top 1340 x 896Top 4340 x 896
Base 1600 x 896Base 3600 x 896Base 260 x 896
Back 2600 x 1110
Front 5 - 117 x 1110
Back 3 - 350 x 1110
Back 1600 x 1110Front 2600 x 1260Top 2580 x 210Top 3580 x 100
Side 2600 x 896Side 5600 x 896Side 3600 x 821
Side 1350 x 896Side 4350 x 896Side 6600 x 821
Front 1 - 157 x 1260Front 3 - 76 x 676Front 4 - 76 x 676

Panels shown are 600mm x 3000mm x 75mm

EK 1250 Heat Cell Cut Pattern

Top 3580 x 100
Top 1490 x 896Top 4350 x 896
Top 2580 x 210
Base 1600 x 896Base 3600 x 896
Base 2360 x 896
Back 2600 x 1410
Front 5 - 117 x 1410
Back 1350 x 1410
Back 3600 x 1410Front 2600 x 1560
Side 2600 x 896Side 5600 x 896Side 3600 x 821
Side 1350 x 896Side 4350 x 896Side 6600 x 821
Front 1 - 157 x 1560
Front 3 - 76 x 676Front 4 - 76 x 676

Panels shown are 600mm x 3000mm x 75mm

EK 1550 Heat Cell Cut Pattern

Front 2600 x 1860
Top 1490 x 896Front 5 - 117 x 1710
Back 3350 x 1710
Base 1600 x 896Base 2600 x 896
Top 4 - 130 x 896
Base 3
60x 896
Back 2600 x 1710Base 4600 x 896Top 2580 x 210Top 3580 x 100
Back 1600 x 1710Top 7490 x 896
Side 2600 x 896Side 5600 x 896Side 3600 x 821Top 5580 x 280Top 6580 x 100
Side 1350 x 896Side 4350 x 896Side 6600 x 821
Front 1 - 157 x 1860
Front 3 - 76 x 676 | Front 4 - 76 x 676

Panels shown are 600mm x 3000mm x 75mm

E4 Timber | Combustible Structure Flue System Installation

Flue Specifications

Note: The EK1550 will require two of each item shown below (two flue terminals, two cones, etc.). The EK1250 and EK950 require one of each item shown below.

Flue terminal (supplied with flue kit) Cone 350mm to 650mm (supplied with flue kit) Spider 350-400-450-650mm (supplied with flue kit) Flashing plate with 550mm liner (installation dependent, not supplied) - flashing must comply with relevant building code 350-400mm spacers and 400-450mm spacers - x1 per 1200mm flue length (x3 of each supplied with flue kit) 350mm flue (3x 1200mm lengths supplied with flue kit) - minimum 3200mm install flue length 400mm inner liner (3x 1200mm lengths supplied with flue kit) 450mm outer liner (3x 1200mm lengths supplied with flue kit) Timber framing chase structure (50mm clearance required to outer liner) AAC heat cell dropbox- MUST be installed to comply with AS/NZS 2918 (supplied separately) 350mm spacer - transfers weight of liners back to flue (supplied with flue kit) Dropbox Gather Top 3.2m min (excluding cowl) Gather Top

NOTE: THE APPLIANCE & FLUE SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH AS/NZS 2918 AND THESE SPECIFICATIONS

Flue Installation-Order of Operations

  1. Place bottom 350 spacer on first length of flue, at height such that the heat cell dropbox will rest on the spacer.
  2. Lift heat cell dropbox over flue onto bottom spacer.
  3. Install first length of flue together with spacer and dropbox. Install flue crimp down to fit into spigot on firebox gather. Dropbox should fit into square hole at top of heat cell.
  4. Place 350-400 spacer onto first length of flue, near top.
  5. Install first length of inner liner, crimp up. Liner fits to dropbox, on the inside of the dropbox's upright tabs.
  6. Place 400-450 spacer onto first inner liner, near top.
  7. Install outer liner, crimp down. Outer liner sits on the dropbox's upright tabs.
  8. Install further lengths of flue, inner and outer liners as required.
  9. Complete flashing of structure.
  10. Attach spider to final length of flue, such that it spaces off liners appropriately.
  11. Fit flashing cone.
  12. Fit cowl.

Note: repeat the above process for the EK 1550 (as it has two flue pipes).

Timber | Combustible Structure Flashing Options

Flashing with Chase Structure
AS/NZS 2918 external requirements of flue termination to adjacent structures apply Flashing to comply with relevant building code Non-combustible calcium silicate board (eg. 9mm promina) required under flashing plate - following perimeter of chase structure Chase can be in contact with heat sensitive roof structure/ part of building 50mm min. clearance required from outer liner to any heat sensitive material 50 50

Flashing through Roof
AS/NZS 2918 external requirements of flue termination to adjacent structures apply Flashing liner 550mm Rubber flashing (eg. dektite) and flashing plate, to comply with relevant building code 50 50mm min. clearance required from outer liner to any heat sensitive material 50

F

Assembling and Installing the Fireplace

F1 Gather Installation

The EK Series fires are shipped with most of the interior components packaged and set inside the gather. Remove all of these components and set them aside for later.

Insert metal bar intoeach set of eyelets. Use the bar to maneuver the gather into place.

CAUTION: Team or mechanically aided lift required for gather.

Gather Weight

EK950: 60 kg

EK1250: 80 kg

EK1550: 120 kg

Once the gather is in place, attach using the bolts, nuts, and washers provided.

F2 Securing the Base of the Appliance

Begin by removing all of the bricks from the fireplace. Remove the shaded parts below to access the securing holes. The EK1250 has been used as an example; the EK950 and EK1550 would be secured in the same manner.

① Lift out the brick tray ② Slide the stainless steel tray out from below the pivot drawer

Note: Gather is not pictured

Secure the appliance base suitably using any 4 of the holes circled below.

Escea EK1550 - F2 Securing the Base of the Appliance - 2

natural_image Pure diagram of a rectangular frame with six circular holes, no text or symbols present

F3 Assembling the Fireplace

The EK1250 has been used as an example in the images below. The EK950 will have one fewer panel and racking strip; the EK1550 will have one more panel and racking strip. Unwrap all of the provided parts and remove the plastic film from the stainless steel tray (1).

Tilt one end of the hanging bar and carefully lift through the front opening and rest on top of the side panels in the cutaway Carefully tilt one end of the brick tray and carefully lift through the front opening and rest the brick tray on the step of each gusset; avoid scratching the sides. Replace each brick one layer deep Slide the stainless steel tray under the pivot drawer ① ② ③ Carefully lift each panel onto each attachment point ④ Lift each racking strip onto each attachment point ensure one strip is installed on each side of all back panels ⑤ Tilt one end of the grille and carefully lift through the front opening and rest the baffle on the top of the side panels ⑥

Note: Gather & pivot drawer not pictured

Place the end spacers at each side of the brick tray to fill in the spaces EK950 there is no end spacer - cut bricks are supplied

Note: For the EK950 there is no end spacer - cut bricks are supplied

F4 Attaching and Removing the Pivot Drawer

The stainless steel pivot drawer at the front of the fire, shaded grey in the diagram below, can be attached and removed from the fire for cleaning or repair. To remove the drawer, follow the instructions below.

NOTE: Remove the protective plastic film on the pivot drawer prior to burning the fire.

Escea EK1550 - F4 Attaching and Removing the Pivot Drawer - 1

natural_image Technical line drawing of a mechanical housing or enclosure with internal components and mounting brackets (no text or symbols)

Escea EK1550 - F4 Attaching and Removing the Pivot Drawer - 2

natural_image Close-up of a black industrial cabinet with transparent plastic panels and a horizontal light fixture (no visible text or symbols)

The drawer is centrally located by a spring on both the right and left hand sides.

Flip the drawer up and remove the screw holding the pin in place.

Escea EK1550 - F4 Attaching and Removing the Pivot Drawer - 3

natural_image Close-up of a metallic pipe fitting attached to a wall, showing internal components and a cylindrical shaft (no text or symbols visible)

Escea EK1550 - F4 Attaching and Removing the Pivot Drawer - 4

natural_image Close-up of a finger pressing a metallic mechanical component with bolts (no text or symbols visible)

With the screw removed, pull on the pin to remove it. Place one hand beneath the spring to catch it as the pin is removed. Repeat this on the opposite side to remove the other pin. The drawer will now slide out.

To replace the drawer, reverse the above steps.

F5 Using the Weather Cover (Optional Accessory)

The weather cover (shown below) provides protection from the elements for the interior of the firebox. It is an optional accessory that can be purchased from your local Escea dealer. Ensure that the firebox is cool prior to fitting the weather cover.

Weather Cover Latch Weather Cover Hooks

To install the weather cover, position the hooks at the bottom of the weather cover on the pins located on either side of the pivot drawer of the fireplace, as shown below.

Escea EK1550 - F5 Using the Weather Cover (Optional Accessory) - 2

natural_image Technical line drawing of a traditional Chinese industrial furnace or boiler unit with a side-view inset showing internal structure (no text or symbols)

With the bottom hooks in place, rotate the weather cover up until it slides into the top, as shown below. Use the latch to ensure that the weather cover is locked into place.

Escea EK1550 - F5 Using the Weather Cover (Optional Accessory) - 3

natural_image Technical line drawing of a mechanical cabinet or enclosure with a conical top and two internal doors (no text or symbols)

G1 Fuel Selection

For optimal wood burning, use firewood with a moisture content of less than 20%.

G2 Starting the Fire

If you are starting your fire for the purpose of cooking, then please proceed to section "H Cooking Guide" on page 28.

To start the fire, stack kindling so that it leans against the back panels, allowing sufficient airflow between pieces. The use of fire-starters is recommended. Continue adding kindling until you have established an ember bed across the entire width of the fire. Use the provided fire poker to arrange the embers across the fire bed.

Escea EK1550 - G2 Starting the Fire - 1

natural_image Architectural cross-section diagram showing structural layers and material distribution (no text or symbols)

DO NOT load wood higher than 33% the height of the firebox
For an optimal lighting time, stack kindling vertically against the back of the firebox and use fire-starters to ignite the wood in a timely manner.

Note: Expansion/contraction noises during heating up and cooling down cycles are normal and to be expected.

G3 Loading the Fire

Once an ember bed has been established, continue loading larger pieces of firewood onto the fire until the desired temperature or look has been reached. Ensure that all pieces of firewood do not protrude past the bottom stainless steel bar on the fireplace.

Do not load wood higher than 1/3 (33%) of the height of the firebox.

G4 Extinguishing the Fire

Once you have finished with burning the fire, remove all embers and remaining wood pieces from the fire and place them in a fireproof pail. Soak them well. Store them for a minimum of 5 days prior to disposing of them safely.

Supervise the fire until all logs and embers have been removed.

Note: The firebox will remain warm for several hours after the embers have been removed. Use caution when touching any parts of the firebox (i.e. the bricks, pivot drawer, or back panels) and supervise small children until the firebox has cooled completely.

Escea EK1550 - G4 Extinguishing the Fire - 1

Cooking Guide

H1 Cast Iron Instructions

All cast iron parts lock into the grill frames provided with the appliance. Ensure that they are securely set prior to cooking.

The cast iron parts supplied are coated in a vitreous enamel. In the event of decay or chipping, the cast iron can be seasoned by rubbing a thin layer of oil on the cast iron and heating the surface.

Seasoning will protect the surface from rusting and reduce the likelihood of food sticking to the surface.

H2 Storage

The EK range of fireplaces is designed to allow storage of cooking implements within the fire. To access the storage area, lift the pivot drawer as shown in the diagram below.

① Lift the front drawer up ② Store cooking plates, cooking frames, and fat drip containers.

H3 Optimal Ember Generation

The most efficient way to cook on a wood fire is over a consistent bed of embers. To achieve this, an ember generation box has been provided. To begin, affix the ember generator to any of the racking sets on the back of the fireplace and follow the instructions below.

Escea EK1550 - H3 Optimal Ember Generation - 1

natural_image Technical illustration of a mechanical device with cutaway view showing internal components (no text or symbols)

Step 1: Affix the ember generator to the back of the firebox

Step 2: Vertically stack kindling

Step 3: Place and ignite fire-starters on the base of the ember generator

Step 4: Place more logs, & if necessary, more fire-starters

Step 5: For optimal ember generation, keep the ember generator fueled with pieces of hardwood that will roughly fit inside the opening of a drinking mug (80mm cross-section).

Note: Other wood or larger wood diameters can be used but will not perform as well. Softwood embers will burn out more quickly and larger diameter wood will take longer to produce embers.

Continue to load the ember generator with wood. Use the fire poker provided to get embers to fall through the grate on the bottom of the ember generator.

H4 Cooking on the Fire

Begin by positioning the desired number of cooking plates at the desired height in the fire. For a warmer grill, position the cooking grills closer to the bottom of the fire. For lower heat, position the cooking grills higher.

Escea EK1550 - H4 Cooking on the Fire - 1

natural_image Technical line drawing of a traditional heating unit with top, side, and interior panels (no text or symbols)

For the slotted grill, it is best to position the fat drip tray on the front of the grill prior to cooking. The fat drip tray will collect any grease drips to provide easy cleanup. Align the hooks of the fat drip tray with the slots in the grill, then pull forward and hook the fat drip tray to the grill frame.

Meat Hooks Slotted Grill Flat Grill Fat Drip Tray Ember Generator

To heat the grills, use the fire poker to scrape the embers from under the ember generator to beneath the desired grill. Continue to load the ember generator so that fresh embers continue to drop through the grate. To maintain heat, continue to scrape fresh embers beneath the cooking area until cooking is complete.

The EK range also comes with meat hooks, as shown in the image above, that can be used to hang and cook large pieces of meat (for example, a whole chicken). The process is the same as with the grills; scrape embers beneath the meat hooks to cook the meat.

It is also possible to use damp wood chips (i.e. cedar, hickory, etc.) thrown directly onto the embers to provide a smoky flavour to the cooking food.

Once you have finished cooking, remove all cooking trays and the ember generator prior to using the fire for standard outdoor heating.

Use the provided gloves when handling the hot cooking trays and the ember generator. Heat will begin to transfer through the gloves after 30 seconds. It is recommended to move the hot trays within 30 seconds. It is also possible to scrape the embers away from the ember generator and cooking trays to allow them to cool; it takes approximately 20 minutes to be able to move them without the heat transferring through the gloves.

Maintenance

I1 Chimney Maintenance

The chimney must be inspected & cleaned at least once per year.

A chimney fire can permanently damage your chimney system; this damage can only be repaired by replacing the damaged component parts.

Chimney fires are not covered by the warranty.

This product may be used on all black painted surfaces and is available from your Escea dealer.

Before application, ensure any corrosion is removed by a wire brush; also ensure that the surface is clean and free of any dust.

There is no guarantee the parts can be returned to a new finish.

Autosol Metal Polish

This product may be used on any stainless steel surfaces and applied with a soft cloth.

There is no guarantee the parts can be returned to a new finish.

Escea EK1550 - Autosol Metal Polish - 1

General Warranty Terms and Conditions

General Information

This quality manufactured product is state of the art. The materials used were meticulously selected and are constantly checked, as is our entire production process.

Setting up or installing this product requires specialised knowledge. Escea products may therefore only be installed and commissioned by specialised firms and in compliance with statutory regulations as amended.

Warranty Conditions for Escea Outdoor Wood Fires

This warranty is provided by Escea Limited (referred to in this document as Escea). The warranty applies from the date of purchase from or through an authorised Escea dealer.

Nature of Warranty

Subject to the exclusions in section 2 & 3, Escea may undertake to put right any defects in the Escea Outdoor Wood Fire products supplied by Escea for the periods specified below:

Parts Parts and Labour Warranty
Basic firebox**: the steel body of the product only5 years*
Any removable part, including: top combustion panel, back panels, cooking plates, ember generator, pivot drawer, operation devices such as handles, adjustment levers2 year*

* From date of purchase
** Failure is considered a physical crack or hole that stops the fire functioning as it is designed to.

Escea must pre-authorise all warranty work.

The benefits provided under this warranty are in addition to the consumer guarantees and any other statutory rights you may have under the consumer law and/or other applicable laws.

Warranty Exclusions

This warranty does not apply and will be void where:

The Escea Outdoor Wood Fire is not installed in accordance with AS/NZS 2918:2001 and any building code and consent (if required).

The Escea Outdoor Wood Fire has not been installed or operated in accordance to the Escea Outdoor Wood Fire installation manual, in particular, defects, malfunctions or failures caused by incorrect installation, normal wear and tear, misuse, neglect, lack of proper and regular maintenance, accidental damage, any other alteration, or failure to follow operating instructions in the installation manual or any misuse that causes an overfired situation resulting in heat damage.

The use of products, including flue systems, that are not specified in accordance with the installation manual.

Repairs or modifications by persons not authorised by Escea, use of parts not supplied by Escea, or damage or other events which have occurred since the product left the control of Escea.

Any scratches, dints, finger print marks, and melted items that occurred after the arrival of the product to the Escea Dealer.

Discolouration of the enamel, galvanized surfaces, or glass caused by soiling by soot or built-in residues of burnt materials as well as visibly changed colour or other aspects due to thermal stress or overloading.

Changes in the interior / exterior surfaces of the house, fire, or flue (e.g. any staining or soot / smoke damage, cracking, discoloration or degradation of surfaces caused by thermal stress or overloading).

Damage caused by abnormally corrosive environments (e.g. sea salt corrosion).

Escea wood fires are coated with high temperature paint that may show signs of surface rust if exposed to moisture for an extended period of time. Any repair and replacements of parts that are subject to normal wear and tear expected with any outdoor fire product. Any rust damage discolouration or corrosion in any part of the fire over life of the fire is not covered by warranty.

Damage caused by water affecting the Escea outdoor wood fire.

Operation of the Escea outdoor wood fire without its back panels (if applicable).

Damage caused by chimney fires.

This warranty does not cover paint blemishes or imperfections because of the uneven nature of high temperature paint. A spray can of touch up paint is available at a local paint merchant.

Subject to any statutory provisions to the contrary, at Escea's discretion, Escea's liability in respect of EK Series products that are found to have manufacturing defects will be limited to refunding, repairing, or replacing the defective products. The reinstatement and replacement of any affected outside wall, ceiling, or floor coverings, coatings, or claddings are not covered by warranty. Escea does not accept liability for consequential damage or any incidental expenses resulting directly or indirectly from any defect or breach of warranty, claims for damage to building or any other consequential loss.

Other Escea Outdoor Wood Fire Warranty Conditions

No dealer, distributor, or similar person has the authority to warrant Escea products beyond the terms contained in this warranty.

This warranty is automatically voided if the appliance's serial number has been removed or altered in anyway.

Any differences in fireplace appearance from Escea promotional images that is due to printing limitations, environmental factors, or wood variations are not a warranty issue.

Where you make a claim under this warranty, an authorised repairer may need to attend your premises to inspect the Escea product. Escea may charge you a service call fee if a repairer will be required to travel more than 30 km from the nearest service centre to your location. You can obtain details on the location of service centres and service call fees by visiting the Escea website or calling the customer care line below.

Warranty Claims

If you make a valid claim under warranty and none of the exclusions set out in section 2 and 3 apply, Escea will, at Escea's election either:

Repair the relevant part of the Escea product; or

Replace the relevant part of the Escea product with a product of identical specification (or where the product is superseded or no longer in stock, with a product of as close a specification as possible).

How to Make a Warranty Claim

To make a valid claim under this warranty, you must:

  • Lodge the claim through the dealer who supplied the fire, as soon as you first become aware of the breakdown. The Escea Dealer will then follow Escea's warranty claim process.
  • Provide the Escea product serial number.
  • Provide reasonable proof of purchase for the Escea product.
  • If required, provide access to the premises at which the Escea product is located (so it can be inspected).
Regions Escea Distributors Filing a Claim
Australia Escea AustraliaPTY Ltd.P.O. Box 176Pennant Hills, 1715, Sydney, NSWAU: 1800 460 832 or WA: 1800 730 140www.escea.com.auVisit the distributor website or call distributor directly.
New Zealand Escea Ltd.17 Carnforth StreetDunedin, 9018, New Zealand0800 17 3000www.escea.comContact the dealer you purchased the fire from

Contact the dealer you purchased the fire from to file a claim.

This document contains technical data subject to change without notice.

Table of contents Click a title to access it
Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : Escea

Model : EK1550

Category : Heating