PKM

BS38-60 ABPH - Range hood PKM - Free user manual and instructions

Find the device manual for free BS38-60 ABPH PKM in PDF.

📄 87 pages English EN Download 💬 AI Question 10 questions ⚙️ Specs
Notice PKM BS38-60 ABPH - page 46
View the manual : Deutsch DE English EN
Pick your language and provide your email: we'll send you a specifically translated version.
Product Type Range Hood (Extractor Hood)
Model BS38-60 ABPH
Brand PKM
Material Glass (black or white)
Installation Width 60 cm
Installation Type Wall-mounted
Control Type Push buttons (5)
Operating Modes Extraction / Recirculation
Energy Efficiency Class A
Annual Energy Consumption 20.6 kWh/year
Air Flow (Low Speed) 152 m³/h
Air Flow (High Speed) 294 m³/h
Noise Level (Low Speed) 53 dB
Noise Level (High Speed) 63 dB
Lighting LED, 2 W (1 x 2.0 W)
Grease Filter 1 aluminium, dishwasher-safe
Carbon Filter (Optional) 2 x CF150
Chimney Height (Telescopic) 40 - 78 cm
Product Dimensions (HxWxD) 29.5 - 107.5 x 60 x 26.3 cm
Net Weight 9.5 kg
Voltage / Frequency 220-240 V / 50 Hz
Connected Load 62 W
Supplied Accessories Exhaust hose, one-way valve, mounting kit, instruction manual

Frequently Asked Questions - BS38-60 ABPH PKM

What are the minimum distances between the hob and the hood?
For ceramic-glass hobs, the minimum distance is 65 cm; for gas cookers, 75 cm; for coal/oil/wood stoves, 85 cm. Always follow the instructions for your specific hob.
How do I install the one-way valve?
If not pre-installed, install the one-way valve by inserting the two flap parts (a and b) into the housing of the exhaust air outlet. Ensure the axle pins point upward and the flaps move freely without jamming.
How do I clean the grease filters?
Remove the grease filters by pressing the locking button on the handle. Clean them manually in warm water (up to 30°C) with a soft brush, or in a dishwasher on a normal programme (up to 30°C). Dry thoroughly before reinstalling. Clean every 2-3 weeks depending on usage.
How do I install and replace the carbon filters?
Carbon filters are optional for recirculation mode. To install, lift the glass cover, remove the grease filter, place the carbon filter on the motor and turn it clockwise until tight. Repeat on the other side. Replace every 3-6 months. Carbon filters are not included; order type CF150.
How do I change the LED light?
The LED light must be replaced by a qualified professional. Disconnect power, remove the grease filter, locate the junction box, disconnect the terminal, press the spring clips inward, and push the LED module downward. Replace with the same type: DBS-2/65-H-120/33, 2.0 W, rectangular 120x33 mm.
What should I do if the hood doesn't work?
Check if the plug is connected, the socket has power, the fuse is on, and the voltage matches. If the motor doesn't run but the light works, the ventilation damper may be blocked or the motor defective. For other issues, refer to the troubleshooting table in the manual.
Can the hood be used in recirculation mode?
Yes, the hood can be used in recirculation mode. In this mode, no exhaust hose is needed; the air is filtered through grease filters and optionally carbon filters to remove odors. Carbon filters must be installed and replaced regularly.
How can I reduce operating noise?
Ensure the exhaust duct is as short and straight as possible, with a diameter of at least 120 mm. Check that filters are clean and not clogged. For extraction mode, avoid obstructions in the air duct. In recirculation mode, replace carbon filters on time.
What is the warranty period?
The appliance has a 24-month guarantee from the date of purchase, covering material and fabrication defects. It does not cover damage from improper use, installation, or normal wear of consumables like bulbs and filters.
Where can I order spare parts or carbon filters?
Spare parts and carbon filters (type CF150) are available at www.pkm-online.de. For other accessories, contact the shop where you purchased the hood.

User questions about BS38-60 ABPH PKM

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Range hood in PDF format for free! Find your manual BS38-60 ABPH - PKM and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. BS38-60 ABPH by PKM.

USER MANUAL BS38-60 ABPH PKM

natural_image Exterior view of a modern kitchen air conditioner unit (no text or symbols visible)

PKM BS38-60 ABPH - 1

natural_image Exterior view of a white stainless steel kitchen range hood (no text or symbols visible)

7 8 6

natural_image Pure geometric diagram of a symmetrical mechanical or architectural component with no text, numbers, or symbols

RICHTIG

PKM BS38-60 ABPH - 3

natural_image Simple line drawing of three overlapping rectangles with a vertical centerline (no text or symbols)

FALSCH

natural_image Diagram of a mechanical or fluid system with directional arrows indicating flow or movement (no text or symbols)
AGLASABDECKUNG DER DUNSTABZUGSHAUBE
BARRETIER-TASTE DES FETTFILTERS
CGRIFF DES FETTFILTERS
DALUMINIUM - FETTFILTER
AGLASABDECKUNG DER DUNSTABZUGSHAUBE
BARRETIER-TASTE DES FETTFILTERS
CGRIFF DES FETTFILTERS
DALUMINIUM - FETTFILTER

Dear customer! We would like to thank you for purchasing a product from our wide range of domestic appliances. Read the complete instruction manual before you operate the appliance for the first time. Retain this instruction manual in a safe place for future reference. If you transfer the appliance to a third party, also hand over this instruction manual.

Index

  1. Safety instructions....47

1.1 Signal words....48
1.2 Safety instructions....48

  1. Installation 52

2.1 Important installation instructions: extraction mode....52
2.2 Minimum distances....53
2.3 View of the appliance ....54
2.4 Installation: one way valve / extractor hood....55

2.4.1 Installation of the one-way valve....56
2.4.2 Installation of the extractor hood .... 58
2.5 Electrical connection....65

  1. Recirculation mode / Extraction mode....65

3.1 Extraction mode 65
3.2 Recirculation mode....66

3.2.1 Carbon filters....66
3.3 Grease filters....70

  1. Control panel and operation....70

4.1 Control panel....70
4.2 Operation....71

  1. Environmental protection 72

5.1 Environmental protection: disposal 72
5.2 Environmental protection: energy saving....72

  1. Cleaning and maintenance....73

6.1 Cleaning of the grease filters....74

6.2 Carbon filters....77
6.3 Replacing of the illuminant....78

  1. Troubleshooting....81
  2. Technical data....83
  3. Waste management....85
  4. Guarantee conditions....86

PKM BS38-60 ABPH - Index - 1

Do not dispose of this appliance together with your domestic waste. The appliance must be disposed of at a collecting centre for recyclable electric and electronic appliances. Do not remove the symbol from the appliance.

The figures in this instruction manual may differ in some details from the current design of your appliance. Nevertheless, follow the instructions in such a case.
i Any modifications, which do not influence the functions of the appliance. shall remain reserved by the manufacturer.
i Please dispose of the packing with respect to your current local and municipal regulations.
The appliance you have purchased may be an enhanced version of the unit this manual was printed for. Nevertheless, the functions and operating conditions are identical. This manual is therefore still valid.
i Technical modifications as well as misprints shall remain reserved.

EU - DECLARATION OF CONFORMITY

★ The products, which are described in this instruction manual, comply with the harmonised regulations.
★ The relevant documents can be requested from the final retailer by the competent authorities.

MAKE SURE THAT THIS MANUAL IS AVAILABLE TO ANYONE USING THE APPLIANCE AND MAKE SURE THAT IT HAS BEEN READ AND UNDERSTOOD PRIOR TO USING THE DEVICE.

The safety instructions/information and contents in this instruction manual apply to all extractor hood models of the BS38 series. Explicit reference is made to possible deviations or differences between the models.

1. Safety instructions

READ THE SAFETY INFORMATION AND THE SAFETY INSTRUCTIONS CAREFULLY BEFORE YOU OPERATE THE APPLIANCE FOR THE FIRST TIME.

All information included in those pages serve for the protection of the operator. If you ignore the safety instructions, you will endanger your health and life.

Store this manual in a safe place so you can use it whenever it is needed. Strictly observe the instructions to avoid damage to persons and property.
Check the technical periphery of the appliance! Do all wires and connections to the appliance work properly? Or are they time-worn and do not match the technical requirements of the appliance? A check-up of existing and new made connections must be done by an authorised professional. All connections and energy-leading components (incl. wires inside a wall) must be checked by a qualified professional. All modifications to the electrical mains to enable the installation of the appliance must be performed by a qualified professional.
i The appliance is intended for private use only.
i The appliance is intended for extracting/recirculating cooking vapours in private household only.
i The appliance is intended for indoor-use only.
The appliance is not intended to be operated for commercial purposes, during camping and in public transport.
i Operate the appliance in accordance with its intended use only.
Do not allow anybody who is not familiar with this instruction manual to operate the appliance.
This appliance may be operated by children aged from 8 years and above as well as by persons with reduced physical, sensory and mental capabilities or lack of experience and knowledge if they are supervised or have been instructed concerning the safe use of the appliance and do comprehend the hazard involved. Children must not play with the appliance. Cleaning and user-maintenance must not be carried out by children unless they are supervised.

1.1 Signal words

⚠️ DANGER! indicates a hazardous situation which, if ignored, will result in death or serious injury.

⚠ WARNING! indicates a hazardous situation which, if ignored, could result in death or serious injury.

CAUTION! indicates a hazardous situation which, if not avoided, may result in minor or moderate injury.

NOTICE! indicates possible damage to the appliance.

1.2 Safety instructions

DANGER!

To reduce the risk of electrocution.

  1. Non-compliance of the orders of this instruction manual will endanger the life and health of the operator and/or can result in damages to the appliance.
  2. Do not operate the appliance when it does not work properly, is visibly damaged, has dropped down or the power cord/plug are damaged.
  3. When the power cord is damaged, it must be replaced by the manufacturer or an authorised aftersales service or a qualified professional (electrical engineer) only.
  4. All electrical work that may be necessary to connect the appliance to the mains must be carried out by a qualified professional (electrical engineer). Do not modify the energy supply. The connection must be carried out in accordance with the current local and legal regulations.
  5. The technical data of your energy supplier must meet the data on the rating plate of the appliance.
  6. Never try to repair the appliance yourself. Repairs carried out by unauthorised persons can cause serious damage. If the appliance does not operate properly, please contact the aftersales service or the shop you purchased the appliance at. ^10 Original spare parts should be used only.

  7. In case of an event caused by a technical malfunction, disconnect the appliance from the mains (fuse box of your household power supply). Contact the aftersales service or the shop you purchased the appliance at. ^11 RISK OF ELECTRIC SHOCK!

  8. Do not operate any room-air dependent fireplaces while operating the appliance; otherwise, harmful gases will get from the fireplace into your home. Whenever the hood is operated together with chimney-vented fireplaces (e.g., coal furnace), ensure there is sufficient air supply in the room where the appliance is installed in. Always consult your local chimney-sweep master. When you operate the appliance in recirculation mode, you can simultaneously run room-air dependent fireplaces.
  9. If gas is set free in your home:

a) open all windows.
b) do not unplug the appliance and do not use the control panel.
c) do not touch the appliance until the gas has gone.
d) otherwise, sparks can be generated which will ignite the gas.

  1. Never pull the power supply cable to unplug the appliance. Always use the power plug itself to unplug the appliance. RISK OF ELECTRIC SHOCK!

  2. Never touch the power plug, the power switch or other electrical components with wet or damp hands. RISK OF ELECTRIC SHOCK!

WARNING!

To reduce the risk of burns, electrocution, fire or injury to persons.

  1. Whenever you use extractor hoods in combination with non-electrically operated appliances (gas and oil-fired appliances), the negative pressure of the corresponding room must not be more than 4 Pa ( 4 × 10^-5 bar).
  2. An electrical supply of 220 \~ 240 V AC / 50 Hz is required. Do not use a socket board or a multi socket or an extension cord when operating the appliance with 220 \~ 240 V / 50 Hz (AC). All electrical connections which may be damaged must be repaired by a qualified professional.
  3. Only connect the appliance to a properly grounded and dedicated socket.
  4. The appliance must be grounded. Only use a proper safety socket to minimise risk of electric shock.

  5. The technical data of your energy supply must meet the data on the rating label.

  6. Your domestic circuit must be equipped with an automatic circuit breaker.

  7. Strictly observe the minimum distance between hood and hob. It is also absolutely necessary to observe the individual minimum distances to extractor hoods which are specified in the instruction manual of your hob / oven / etc.

MINIMUM DISTANCE HOOD TO
ceramic-glass rings / hotplatesmin. 65 cm
gas cookersmin. 75 cm
coal / oil / stove wood firingmin. 85 cm
  1. Never install the appliance below the required minimum distance. If you ignore the required minimum distance, the accumulated fat in the filters can catch fire due to the heat emission of the hob. RISK OF FIRE!

  2. The load-bearing capacity of the wall/ceiling ^12 of the installation room must be checked before you install the appliance. The appliance must be installed at a suitable position only.

  3. Before you install the appliance, check that there are not any electrical or other cables in the installation area; this prevents these cables from being drilled unintentionally. RISK OF ELECTIC SHOCK!

  4. We recommend carrying out the installation of the extractor hood by qualified personnel. Any damage caused by improper installation of the appliance are not subject to the guarantee or warranty!

  5. Do not cook a la flambé dishes below the extractor hood. The flames may damage your appliance and / or cause fire.

  6. Do not operate the gas jets of a gas hob without cookware. The flames may damage your appliance and / or cause fire.

  7. If you fry, permanently keep an eye on the oil as it can catch fire. The risk of auto-ignition rises when using the oil many times.

  8. Do not carry out any procedures on the hob using naked light or fire. The flames may damage your appliance and / or cause fire.

  9. The exhaust hose (depending on model) must not be made of flammable materials or contain any flammable materials.

  10. Operate the appliance with inserted grease filters only. Otherwise, recirculating-transported fat will deposit in the appliance and the exhaust system. RISK OF FIRE! Clean or replace the filters regularly.

  11. Disconnect the appliance from the mains before you clean or maintain it.
  12. Failure to follow the cleaning instructions will increase the RISK OF FIRE due to fat deposits.
  13. While unpacking, the packaging materials (polythene bags, polystyrene pieces, etc.) should be kept away from children. CHOKING HAZARD! RISK OF INJURY!
  14. Always supervise children when they are near the appliance.
  15. Children must not play with the appliance.
  16. Only allow children to use the appliance without supervision when adequate instructions have been given before so that the child is able to use the appliance in a safe way and understands the risks of improper use.

CAUTION!

  1. Accessible parts of the hood may become hot while cooking.
  2. Any potential user must be careful not to hit their head on the corners and edges of the appliance. RISK OF BRUISES! RISK OF INJURIES IN THE OCULAR AREA!
  3. Carry out the installation of the appliance with at least two persons. Risk of damage. RISK OF INJURY!

NOTICE!

  1. The appliance must be transported and installed by at least two persons.
  2. Unpack the parts of the chimney very carefully; otherwise, you will damage the chimney.
  3. Remove the complete packaging materials before initial operation. The appliance may be equipped with a transportation lock. Remove the transportation lock completely. When removing be very careful. Do not use any aggressive detergents to remove residues of the transportation lock.
  4. Take the enclosed parts from the packaging and its polystyrene-components.

  5. Do not use any aggressive, abrasive and acrid detergents or sharpedged items to clean the appliance. Otherwise, you may scratch the surface. RISK OF DAMAGE!

  6. Clean and maintain the appliance regularly to enable its proper operation and optimal performance.
  7. Check that the power cord and the appliance are not damaged before electrical connection.
  8. The rating plate must not be removed or made illegible, otherwise all terms of the warranty become invalid!

SAVE THESE INSTRUCTIONS.

★ The manufacturer and distributor are not responsible for any damage or injury in the event of failure to comply with these instructions.

2. Installation

NOTICE! Any damage caused by an appliance that is improperly installed and improperly connected to the mains is not covered by the warranty or guarantee.

We recommend carrying out the installation of the extractor hood by qualified personnel. Damages caused by improper installation of the appliance are not subject to the guarantee or warranty!

2.1 Important installation instructions: extraction mode

⚠ WARNING! Do not lead the exhaust air into a chimney which is used for extracting exhaust air of appliances operated by gas or other combustibles.

  1. For extracting the exhaust air always observe the current legal regulations.
  2. The diameter of the exhaust hose must meet the diameter of the connecting ring.
  3. If your appliance is equipped with a carbon filter, remove the carbon filter before you operate the appliance in the extraction mode. The carbon filter should be used in the recirculating mode only.

  4. The exhaust duct should be as short and straight as possible. The diameter of the exhaust hose should be at least 120/150 mm (look at chapter TECHNICAL DATA). Otherwise, you have to expect increased noise and decreased performance of your appliance.

  5. The proper maximum bending angle outwards is 120^ .
  6. Use smooth tubes or flexible, non-inflammable exhaust hoses only.
  7. When the exhaust duct is connected horizontally, a minimum falling gradient of 1 cm/m or an inclination of 2^ is required. Otherwise, condensate will get into the motor of the hood.
  8. When an exhaust duct is used, the ending of the exhaust hose must be adjusted into the direction of flow.
  9. If the exhaust duct passes through cool areas (e.g., an attic), a temperature gradient may occur in the different parts of the exhaust duct so condensate will be generated. Proper insulation of the corresponding parts of the exhaust duct will then be needed. Equip such an exhaust duct with a condensate trap if need be.
  10. Depending on the model the hood is equipped with one (top) or two (top, back) outlets. The idle outlet is covered by a plastic cap. You can remove this cap by turning it anticlockwise. Use the cap to cover the idle outlet.

2.2 Minimum distances

i Strictly observe the minimum distance between the extractor hood and the hob.
i It is also absolutely necessary to observe the individual minimum distances between hobs and extractor hoods; these are specified in the instruction manual of your hob / oven / etc.

REQUIRED MINIMUM DISTANCE HOOD TO
ceramic-glass rings / hotplatesmin. 65 cm
gas cookersmin. 75 cm
coal / oil / stove wood firingmin. 85 cm
  1. The minimum distances do not represent the required total height, but a minimum value generated by adding the height of the hob (floor hob) and the required minimum distance of the hob to the extractor hood (hob extractor hood)

$$ (\text { floor } \leftrightarrow \text { hob }) $$

$$ + \quad (\text { h o b } \leftrightarrow \text { e x t r a c t o r h o o d }) $$

$$ = \text { MINIMUM INSTALLATION HEIGHT } $$

  1. Adapt the total installation height to the height of the user. Please note that the extraction capacity of the appliance can decrease if installed at a large distance to the hob.

WARNING! Never install the appliance below the required minimum distance. If you ignore the required minimum distance, the accumulated fat in the filters can catch fire due to the heat emission of the hob. RISK OF FIRE!

CAUTION! Any potential user must be careful not to hit their head on the corners and edges of the extractor hood. RISK OF BRUISES! RISK OF INJURIES IN THE OCULAR AREA!

2.3 View of the appliance

Technical diagram of a mechanical assembly with labeled components 1 through 5

7 8 6

1HOUSING OF THE EXTRACTOR HOOD
2CONTROL PANEL
3ONE-WAY VALVE
4EXHAUST AIR OUTLET
5EXHAUST HOSE (for extraction mode only)
6OUTER CHIMNEY
7INNER CHIMNEY
8FIXING BRACKET

2.4 Installation: one way valve / extractor hood

WARNING! For safety reasons, use only fastening or installation screws of the sizes specified in this instruction manual. Failure to follow the size and installation instructions for screws or mounting devices may result in electrical hazards. RISK OF ELECTRIC SHOCK!

WARNING! Do not damage the wiring in the wall while drilling. RISK OF ELECTRIC SHOCK!

NOTICE! Two assistants are required for installation.

NOTICE! Any damage caused by an appliance that is improperly installed and improperly connected to the mains is not covered by the warranty or guarantee.

We recommend carrying out the installation of the extractor hood by qualified personnel. Damages caused by improper installation of the appliance are not subject to the guarantee or warranty!

YOU CAN LAY THE EXHAUST HOSE AS FOLLOWS(FOR EXTRACTION MODE ONLY)
VERTICALLY: lay the exhaust hose to a roof cap*.PKM BS38-60 ABPH - Installation: one way valve / extractor hood - 1Fig. similar.
HORIZONTALLY: lay the exhaust hose to an exhaust outlet equipped with an air grille*.PKM BS38-60 ABPH - Installation: one way valve / extractor hood - 2Fig. similar.
*Article not included in the scope of delivery.

2.4.1 Installation of the one-way valve

If your appliance does not have the one-way valve installed at the factory, you still need to install it. The following figures only show an example of how to install the one-way valve, as the exhaust air outlet may vary depending on the model and configuration of the appliance.
The one-way valve consists of two flap parts (a / b). You must install both flap parts individually in the housing of the exhaust air outlet (c / s. fig. below).

b a c

aONE-WAY VALVE: flap part « a »
bONE-WAY VALVE: flap part « b »
cHOUSING OF THE EXHAUST AIR OUTLET

INSTALLATION STEPS

  1. Each of the two individual flap parts (a / b) consist of a semicircle including an axle (d). In the centre of the axle (d) of a flap part is an axle pin (e / s. fig. below).

  2. Insert the axle (d) of a flap part carefully into the corresponding openings (f / on both sides) in the housing of the exhaust air outlet (c); the axle pin (e) must point upwards (s. fig. below).

  3. Repeat step 2 for the other flap part.

  4. Ensure that both parts of the one-way valve are installed properly. The flap parts must not jam or get caught.

b f d a e ↓ c b e a d f d

aONE-WAY VALVE: flap part « a »
bONE-WAY VALVE: flap part « b »
cHOUSING OF THE EXHAUST AIR OUTLET
dAXLES
eAXLE PINS
fOPENINGS in the housing of the exhaust air outlet (on both sides)

2.4.2 Installation of the extractor hood

INSTALLATION STEPS

  1. Find a suitable position for the extractor hood.
  2. Measure and mark the positions of the four drill holes required (2 for the inner chimney bracket and two for the housing of the extractor hood). Ensure that the minimum distances are observed.
    Note that the position of the screw holes for the fixing of the inner chimney bracket, also represents the highest point of the entire chimney.
  3. For the fixing of the inner chimney bracket (A) and the housing of the appliance, drill 4 holes (∅ 8 mm) in the wall. Insert the expansion dowels (B) into the four drilled holes (C).
  4. For the fixing of the housing of the appliance, screw two screws (D / 4*30 mm) into the expansion dowels. Do not tighten the screws completely as you have to hang the appliance on the screw heads. The screw heads must have a distance of 3 - 5 mm to the wall.
  5. Fix the inner chimney bracket (A) on the wall using two screws (E / 4*40 mm).

A E C B D

AINNER CHIMNEY BRACKET
BEXPANSION DOWELS (4 pcs. in total)
CSCREW HOLES (4 pcs. in total)
DSCREWS: 4*30 mm (2 pcs. in total)
ESCREWS: 4*40 mm (2 pcs. in total)
  1. If the one-way valve (F) has not yet been installed, install it now (s. chapter 2.4.1 INSTALLATION OF THE ONE-WAY VALVE).

  2. EXTRACTION MODE: connect the exhaust hose (G) to the exhaust air outlet (H) of the extractor hood (J / s. fig. below on the left). Fix the exhaust hose (G) using a cable tie (K / s. fig. below on the right).

RECIRCULATION MODE: please ignore step 7. « EXTRACTION MODE » and step 13.; please observe the instructions given in chapter 3.2 RECIRCULATION MODE.

G F H J

G H K

FONE-WAY VALVE
GEXHAUST HOSE (for extraction mode only)
HEXHAUST AIR OUTLET
JHOUSING OF THE EXTRACTOR HOOD
KCABLE TIE ^13
  1. Hang the extractor hood on the wall by placing the installation openings (L) of the extractor hood on the screws (D). Align the extractor hood properly.
  2. When the extractor hood is aligned properly, tighten the two screws (D / 4*30 mm).
    Two safety vents, each with a diameter of 6 mm, are on the back side of the extractor hood housing.

A D G L J

AINNER CHIMNEY BRACKET
DSCREWS: 4*30 mm (2 pcs. in total)
GEXHAUST HOSE (for extraction mode only)
JHOUSING OF THE EXTRACTOR HOOD
LINSTALLATION OPENINGS (2 / on the back side of the housing)
  1. Insert the inner chimney (O) into the outer chimney (N). Fix the fixing bracket (M) on the outer chimney using the corresponding screws (s. fig. below). Do not tighten the screws too firmly so that the inner chimney remains extendable after installation.

O M P N

MFIXING BRACKET OF THE OUTER CHIMNEY
NOUTER CHIMNEY
OINNER CHIMNEY
PSCREWS
  1. Place the whole chimney (O + N) on the extractor hood and guide the exhaust hose (G / for extraction mode only) to the outside (s. fig. below on the left and s. step 13.).

  2. Fix the outer chimney (N) on the appliance using 2 corresponding screws (4*8 mm): s. fig. below on the right.

A G O N

N Q

AINNER CHIMNEY BRACKET
DEXHAUST HOSE (for extraction mode only)
GINNER CHIMNEY
JOUTER CHIMNEY
LSCREWS (4*8 mm /2 in total) to fix the chimney on the appliance
  1. You can lay the exhaust hose as follows (for EXTRACTION MODE ONLY).
VERTICALLY: lay the exhaust hose to a roof cap*.PKM BS38-60 ABPH - INSTALLATION STEPS - 8Fig. similar.
HORIZONTALLY: lay the exhaust hose to an exhaust outlet equipped with an air grille*.PKM BS38-60 ABPH - INSTALLATION STEPS - 9Fig. similar.

* | Article not included in the scope of delivery.

  1. Pull out the inner chimney (O); up to the installed inner chimney bracket (A). Fix the inner chimney (O) on the inner chimney bracket (A) using the appropriate screws (R / 4*8 mm): s. fig. below.

A R O

AINNER CHIMNEY BRACKET
OINNER CHIMNEY
RSCREWS (4*8 mm / 2 pcs. in total) to fix the inner chimney
  1. Install the grease filters (s. chapter 6.1 CLEANING OF THE GREASE FILTERS) and connect the appliance to the mains ^14 .

Check the correct position of the extractor hood from front and side perspective. Otherwise, the appliance will not work properly.

PKM BS38-60 ABPH - INSTALLATION STEPS - 11

natural_image Pure geometric diagram of a symmetrical mechanical or architectural component with no text, numbers, or symbols

RIGHT

PKM BS38-60 ABPH - INSTALLATION STEPS - 12

natural_image Abstract geometric diagram of three overlapping rectangles with a vertical line crossing through them (no text or symbols)

WRONG

2.5 Electrical connection

Check that the voltage indicated on the rating plate matches the mains voltage of your home before you connect the extractor hood to the mains.
Check that the extractor hood is installed properly before you connect the appliance to the mains.

NOTICE! Any damage caused by an appliance that is improperly connected to the mains is not covered by the warranty or guarantee.

3. Recirculation mode / Extraction mode

3.1 Extraction mode

⚠ WARNING! Do not lead the exhaust air into a chimney which is used for extracting exhaust air of appliances operated by gas or other combustibles.

The extractor hood is usually ready for the use in extraction mode (modifications are possible).
In extraction mode, the intake air is led through an exhaust hose to the outside. For this purpose, an exhaust shaft or an outwardly leading exhaust pipe must be available in your house / flat.
If your appliance is equipped with a carbon filter, you must remove the carbon filter before you operate the appliance in extraction mode!
i If you want to use the extractor hood in extraction mode, please always observe the instructions given in chapter 2. INSTALLATION et seq. and in chapter 2.4.2 INSTALLATION OF THE EXTRACTOR HOOD: step 7. « EXTRACTION MODE » and step 13.

3.2 Recirculation mode

You can also use the appliance in recirculation mode.
If you do not use an exhaust air pipe to the outside for the installation of the extractor hood, the exhaust hose is not required.
In recirculation mode, the exhaust air is led back into the kitchen (s. fig. below).
If you want to use the extractor hood in recirculation mode, you can install carbon filters (s. chapter 3.2.1 CARBON FILTERS).
In addition to the grease filters (must always be installed), carbon filters also neutralise odours and absorb fine dust particles, etc. In this way, carbon filters additionally improve the exhaust air that is returned to the kitchen. We always recommend the use of carbon filters in recirculation mode.

The installation of the extractor hood is the same as described in chapter 2.4.2 INSTALLATION OF THE EXTRACTOR HOOD (please ignore step 7. « EXTRACTION MODE » and step 13.).

Only in recirculation mode you can use CARBON FILTERS to eliminate cooking vapours and odours.

PKM BS38-60 ABPH - Recirculation mode - 1

natural_image Diagram of a mechanical or fluidic component with directional arrows indicating flow or movement (no text or symbols)

Fig. similar: fig. serves as an example only.

3.2.1 Carbon filters

Product code: CF150

⚠ WARNING! Carbon filters must be used in recirculation mode only!

NOTICE! Carbon filters are not included in the scope of delivery ^15 .

i Replace the CARBON FILTERS regularly (see also chapter CLEANING AND MAINTENANCE).
i CARBON FILTERS for your extractor hood are optionally available.

You can order the CARBON FILTERS at

www.pkm-online.de

➢ Type name of the CARBON FILTERS: See chapter TECHNICAL DATA

⚠ WARNING! Switch off the appliance and disconnect it from the mains before you install any carbon filters (use the relevant fuse in your household fuse box).

HOW TO INSTALL THE CARBON FILTERS

  1. Lift the glass cover (A) of the extractor hood to open the appliance (s. fig. below, direction of arrow).
  2. Remove the aluminium grease filter: press the locking button (B) on the handle (C) of the grease filter (D) to release the grease filter from its lock (s. fig. below). Then remove the grease filter (D).
    i Behind the grease filter is the motor of the appliance. The carbon filters are installed on the motor.

Technical diagram of a device with labeled components A, B, C, D and directional arrows indicating movement or flow.

AGLASS COVER OF THE EXTRACTOR HOOD
BLOCKING BUTTON OF THE GREASE FILTER
CHANDLE OF THE GREASE FILTER
DALUMINIUM GREASE FILTER
  1. The CARBON FILTERS are intended to be installed on both sides of the motor.

  2. Place the CARBON FILTER on the motor and turn it clockwise until it is firmly tightened (s. fig. below).

1 2 -3

Fig. similar: modifications are possible.

1MOTOR
2CARBON FILTER
3CLOCKWISE ROTATIONPlace the CARBON FILTER on the motor and turn the filter clockwise until it is installed properly.
  1. Repeat the procedure on the other side of the motor.

  2. If you want to uninstall the CARBON FILTERS, turn the filters anti-clockwise and remove them.

  3. Reinstall the aluminium grease filter: insert the grease filter properly into the corresponding slots on the extractor hood. Press and hold the locking button (B) on the grease filter handle (C) while pushing the grease filter into its proper position. Once the grease filter is properly in position, release the locking button (B) to lock the grease filter in place (s. fig. below).

  4. Lower the glass cover (A) of the extractor hood carefully to close the appliance (s. fig. below).

A D C B 00000

AGLASS COVER OF THE EXTRACTOR HOOD
BLOCKING BUTTON OF THE GREASE FILTER
CHANDLE OF THE GREASE FILTER
DALUMINIUM GREASE FILTER

⚠ WARNING! Install the carbon filters safely and properly; otherwise, the carbon filters can loosen and cause hazardous situations.

⚠ WARNING! Operate the appliance with inserted grease filters only. Otherwise, recirculating-transported fat will deposit in the appliance and the exhaust system. RISK OF FIRE!

NOTICE! The suction capacity is decreased by installed carbon filters.

NOTICE! Depending on frequency of use, replace the carbon filters every three to six months. Clean the grease filter(s) regularly for proper operation of the motor (s. chapter CLEANING AND MAINTENANCE).

3.3 Grease filters

i Always ensure that the grease filters are inserted properly.
i Clean the grease filters regularly (s. chapter CLEANING AND MAINTENANCE).

WARNING! Operate the appliance with inserted grease filters only. Otherwise, recirculating-transported fat will deposit in the appliance and the exhaust system. RISK OF FIRE!

4. Control panel and operation

4.1 Control panel

⚠ WARNING! The illuminant must not be covered by thermal insulation or other materials. RISK OF FIRE!

⚠️ CAUTION! Do not touch the illuminant within 30 minutes after using the appliance. RISK OF BURNS!

NOTICE! Only switch on the illuminant while the appliance is operating. Do not switch on the illuminant to illuminate the room.

NOTICE! Never press two buttons simultaneously.

PKM BS38-60 ABPH - Control panel - 1

PKM BS38-60 ABPH - Control panel - 2BUTTON: « OFF »
PKM BS38-60 ABPH - Control panel - 3LOW POWER LEVEL (motor speed)
PKM BS38-60 ABPH - Control panel - 4MEDIUM POWER LEVEL (motor speed)
PKM BS38-60 ABPH - Control panel - 5HIGH POWER LEVEL (motor speed)
PKM BS38-60 ABPH - Control panel - 6ILLUMINANT ON / OFF

4.2 Operation

0BUTTON: « OFF »

◆ Press this button to switch off the extractor hood.

POWER LEVEL 1 = LOW POWER LEVEL

❖ Press this button to set the lowest power level (motor speed) of the extractor hood.
This power level is suitable for slow cooking / simmering and roasting with the lid of the cookware closed.
Use this power level when low steam generation occurs (low concentration of cooking fumes).

✿ Press this button to set the medium power level (motor speed) of the extractor hood.
❖ This power level is suitable for standard cooking.
Use this power level for an ideal air circulation in the kitchen when medium steam generation occurs (medium concentration of cooking fumes).

PKM BS38-60 ABPH - Operation - 1

❖ Press this button to set the highest / maximum power level (motor speed) of the extractor hood.

Use this power level when lots of steam occurs (strong concentration of cooking fumes).

PKM BS38-60 ABPH - Operation - 2

❖ Press this button to switch on/off the illuminant of the appliance (press button briefly).

i Only switch on the illuminant while the appliance is operating. Do not switch on the illuminant to illuminate the room.

5. Environmental protection

5.1 Environmental protection: disposal

Appliances bearing this symbol « — » must not be disposed of together with household waste throughout the EU. To prevent potential damage to the environment or human health from uncontrolled waste disposal and to promote the sustainable reuse of material resources, responsibly supply the appliance to a recycling centre.

5.2 Environmental protection: energy saving

◆ Cover your cookware (cooking pot / pan) with lids during cooking.
The diameter of the cooking pot / pan should meet the diameter of the cooking zone or the size of the flame of the burner (gas appliances).
❖ Switch off the extractor hood after cooking or use the delayed switch-off function (equipment depends on model).

Only switch on the illuminant while the appliance is in operation. Do not switch on the illuminant to illuminate the room.
❖ Switch off the illuminant(s) of the appliance after cooking.
The power level should always meet the intensity of the generated cooking fumes. Use the highest motor speed of the appliance (highest power level) to extract strong concentration of cooking fumes only. A lower power level always means a lower energy consumption.
Make sure there is sufficient supply air to allow the extractor hood to operate efficiently and with low operating noise.
In the case of a strong concentration of cooking fumes select a higher power level early. Cooking fumes which are already distributed in the kitchen may require a longer operation of the extractor hood.
- Clean the aluminium grease filter(s) regularly as clean filters will increase the efficiency of the appliance.
❖ Replace the carbon filters (for recirculation mode only) regularly. Observe the information given on the packaging of the carbon filters.

6. Cleaning and maintenance

⚠ WARNING! Disconnect the appliance from the mains before you clean or maintain it.

⚠ WARNING! Ignoring the cleaning and maintenance instructions will cause an increased RISK OF FIRE.

NOTICE! Take off all rings and bracelets before cleaning or maintaining the appliance; otherwise, you will damage the surface of the appliance.

  1. Clean the housing of the appliance with a suitable detergent. Use such a product carefully and economically.
  2. Do not clean the control panel with a detergent. Use a damp cloth. Otherwise, you may damage the electronic components of the controls.
  3. Never use any alcohol-containing detergents to clean matt black painted appliances as these detergents cause colour-changes.
  4. Clean the glass panels ^16 with a suitable detergent only.

  5. When you clean or replace the grease filters or the carbon filters, also clean all visible components on the bottom of the appliance with a mild, non-acrid and fat-dissolving detergent.

  6. Do not damage the grid of metal-made grease filters. The colour of the metal surface may change due to frequent cleaning as well as the use of aggressive detergents. Such changes do not influence the capacity of the appliance and are no reason for complaint.
  7. Do not use any abrasive detergents or vinegar cleaners.
  8. Do not use a steam cleaner. RISK OF ELECTRIC SHOCK!

SPECIAL INSTRUCTIONS FOR APPLIANCES WITH A STAINLESS-STEEL CASING ^17

To clean stainless-steel surfaces, use a non-abrasive stainless-steel cleaning agent only.

NOTICE! Never use stainless steel cleaner for the direct environment of the control panel or the control panel itself.

NOTICE! Aggressive detergents such as abrasive detergents, vinegar cleaners, etc. damage the surface of the extractor hood.

6.1 Cleaning of the grease filters

⚠ WARNING! Failure to follow the cleaning instructions will increase the RISK OF FIRE due to fat deposits.

NOTICE! The colour of the metal surface may change due to frequent cleaning as well as the use of aggressive detergents. Such changes do not influence the capacity of the appliance and are no reason for complaint.

NOTICE! Do not damage the grid of metal-made (aluminium) grease filters.

i You do not need to replace grease / aluminium filters ^18 .

  • Clean the filters by hand or in a dishwasher regularly (up to 30 °C).
    Do not use any acrid or corrosive detergents.

Do not use any abrasive detergents!
Do not use any alkaline dishwasher-detergents! (pH more than 7).

CLEANING INTERVAL FOR ALUMINIUM GREASE FILTERS

➢ Every 2 - 3 weeks according to the frequency of use of the extractor hood.

HOW TO DEINSTALL / INSTALL THE ALUMINIUM GREASE FILTERS

  1. Lift the glass cover (A) of the extractor hood to open the appliance (s. fig. below, direction of arrow). Behind the glass cover is the aluminium grease filter.
  2. Press the locking button (B) on the handle (C) of the grease filter (D) to release the grease filter from its lock (s. fig. below). Then remove the grease filter (D) and clean it as described in this chapter.

Technical diagram of a device with labeled components A, B, C, D and directional arrows indicating movement or flow.

AGLASS COVER OF THE EXTRACTOR HOOD
BLOCKING BUTTON OF THE GREASE FILTER
CHANDLE OF THE GREASE FILTER
DALUMINIUM GREASE FILTER
  1. To reinstall the cleaned aluminium grease filter, insert the grease filter properly into the corresponding slots on the extractor hood. Press and hold the locking button (B) on the grease filter handle (C) while pushing the grease filter into its proper position. Once the grease filter is properly in position, release the locking button (B) to lock the grease filter in place (s. fig. below).

  2. Lower the glass cover (A) of the extractor hood carefully to close the appliance (s. fig. below).

A D C B

AGLASS COVER OF THE EXTRACTOR HOOD
BLOCKING BUTTON OF THE GREASE FILTER
CHANDLE OF THE GREASE FILTER
DALUMINIUM GREASE FILTER

⚠ WARNING! Operate the appliance with inserted grease filters only. Otherwise, recirculating-transported fat will deposit in the appliance and the exhaust system. RISK OF FIRE!

HOW TO CLEAN THE ALUMINIUM GREASE FILTERS MANUALLY

  1. Soak the aluminium grease filters in warm rinse water (up to 30 °C)
  2. Then clean the grease filters with a soft brush. Be careful not to damage the grid of the grease filters.
  3. After cleaning: Rinse the grease filters thoroughly using hot water.
  4. Repeat this process in case of stubborn soilings or deposits.
  5. Dry the filters properly before you reinstall them.

HOW TO CLEAN THE ALUMINIUM GREASE FILTERS IN THE DISHWASHER

The grease filters can also be cleaned in the dishwasher: Normal programme (up to 30 °C).

Do not put the filters in the dishwasher together with tableware. Dry the filters properly before you reinstall them.

NOTICE! Filters which are blocked with food leftovers are not covered by the guarantee.

6.2 Carbon filters

⚠ WARNING! Switch off the appliance and disconnect it from the mains before you install any carbon filters (use the relevant fuse in your household fuse box).

i CARBON FILTERS for your extractor hood are optional available.

◆ Conventional carbon filters cannot be cleaned.
The capacity of these filters is limited. You can use such filters for about 3 - 6 months approx.
❖ Replace used filters immediately. Find further information on the filter packaging.

REPLACEMENT INTERVAL FOR CARBON FILTERS

At least every 3 - 6 months according to the frequency of use of the extractor hood.

You can order the CARBON FILTERS at

www.pkm-online.de

➢ Type name of the CARBON FILTERS: See chapter TECHNICAL DATA

6.3 Replacing of the illuminant

⚠ WARNING! The LED illuminant must be replaced by a competent person only. Do not carry out the replacement of the illuminant yourself. If the LED illuminant is damaged, please contact a qualified professional (electrical engineer): not covered by the guarantee.

WARNING! Switch off the appliance and disconnect it from the mains before you replace the illuminant (use the relevant fuse in your household fuse box).

NOTICE! Do not touch the illuminant with your hands. The sweat on your fingers will reduce the operating time of your new illuminant. Use a thin cloth or a thin glove.

INSTRUCTIONS FOR THE QUALIFIED PROFESSIONAL (ELECTRICAL ENGINEER)

  1. The LED illuminant should have cooled down before you remove it.
  2. Open the extractor hood and remove the aluminium grease filter (s. chapter 6.1 CLEANING OF THE GREASE FILTERS).
  3. Locate the junction box (A). Unscrew and remove the cover (B) of the junction box (s. figure below).

If the junction box has a securing plate (C) that presses down the illuminant connection cable to hold it in position, the securing plate must also be uninstalled (s. fig. below).

B C A

AJUNCTION BOX
BCOVER OF THE JUNCTION BOX
CSECURING PLATE
  1. Locate the terminal (D) of the illuminant connection cable (E) in the junction box and disconnect it (s. fig. below).

E D

DTERMINAL OF THE ILLUMINANT CONNECTION CABLE
EILLUMINANT CONNECTION CABLE
  1. Carefully press the spring clips (F) on both sides of the LED illuminant (G) inwards using your hand (s. fig below on the left). Simultaneously push the LED illuminant (G) downwards out of its holder (H / s. fig. below on the right). You can also use a flathead screwdriver for this purpose (s. fig. below on the left). Be very careful when doing this.

  2. Then carefully pull out the illuminant connection cable (E) slightly (s. fig. below on the right).

F G F

H E G

G

EILLUMINANT CONNECTION CABLE
FSPRING CLIPS (4 pcs. in total)
GSECURING PLATE
HILLUMINANT HOLDER
  1. Replace the used LED illuminant by a new one of the same type and power.

a. ILCOS D-Code for this illuminant: DBS-2/65-H-120/33.
b. LED module - rectangular lamp.
c. Max. Wattage: 1*2.0 W.
d. Rectangular lamp: dimensions W*D in mm = 120.00 ± 1.00*33.00 ± 0.50.

120±1 33±0.5

  1. To reinstall the LED illuminant, please proceed in reverse order.
Required minimum distance to surfaces such as pot lids, oven cloths etc. to avoid any hot parts and risk of fire.
--- m = 0.45 m
PKM BS38-60 ABPH - INSTRUCTIONS FOR THE QUALIFIED PROFESSIONAL (ELECTRICAL ENGINEER) - 7Only use self-shielded illuminants to avoid hot parts, risk of fire and exposure to UV-radiation.

NOTICE! Any damage caused by improper and incorrect replacement of the LED illuminant is not subject to the guarantee!

7. Troubleshooting

MALFUNCTION
POSSIBLE CAUSEMEASURE
THE APPLIANCE DOES NOT WORK AT ALL.
1. The plug of the appliance is not connected to the socket.2. The plug has become loose.3. The socket is not supplied with energy.4. The fuse is switched off.5. The voltage is too low.1. Connect the appliance to the mains properly.2. Check the plug.3. Check the corresponding socket by connecting it with another appliance.4. Check the fuse box.5. Compare the data on the model plate with the data of your energy supplier.
THE ILLUMINANT IS ON BUT THE MOTOR DOES NOT WORK.
1. Ventilation damper blocked.2. Motor mounting defective.1. Remove blockage.2. Replace motor.
ABNORMAL MOTOR-SMELLS.
1. Motor defective.1. Replace motor.
SMEAR OF OIL.
1. One-way valve is leaky.1. Seal the valve.
THE APPLIANCE VIBRATES.
1. Motor not properly fixed.2. Hood not properly fixed.1. Fix motor properly.2. Fix hood properly.
INSUFFICIENT EXTRACTING CAPACITY.
1. Too much distance hood-hob.2. Too much draught because of open doors and/or windows.1. Lower position of hood.2. Close the doors/windows.
THE APPLIANCE IS UNSTABLE.
1. Screws are not firmly tightened.2. The mounting bracket / mounting plate is not fixed firmly.1. Tighten the screws.2. Fix the mounting bracket / mounting plate properly.

i If the appliance has a malfunction not noted on the schedule or if you have checked all items on the schedule but the problem still exists, please contact the shop you purchased the appliance at.

IF THE HOOD DOES NOT WORK PROPERLY AND / OR YOU CAN HEAR INCREASED OPERATING NOISE, CHECK THE SCHEDULE BELOW.

IN EXTRACTION MODE

▶ Incorrect dimension of the air duct.
Obstruction in the air duct.
The diameter of the air duct from hood to wall-box inclusive should be 120 mm; otherwise, the capacity of the motor may be decreased.

If you have installed a fly screen on the wall-box, the air vent may be obstructed. Check by removing the fly screen.
If the cover panel of the wall box is equipped with firm and slanted slats, the air vent may be obstructed. Check by removing the cover panel.
➢ Install a cover panel with moveable slats, which do not obstruct the air vent.
▶ Check condition and cleanliness of the filters.
➢ Check if the air which is extracted by the hood is replaced to avoid negative pressure.

IN RECIRCULATION MODE

▶ Check condition and cleanliness of the filters.
When you run your appliance in recirculation mode, check if the carbon filter has been replaced on time (min. every 3-6 months).

If the appliance has a malfunction not noted on the schedule or if you have checked all items on the schedule but the problem still exists, please contact the shop you purchased the appliance at.

8. Technical data\*

TypeExtractor hood
MaterialGlass (black or white)
Installation-width in cm60.00
Wall installationyes
Push buttonsyes / 5 pcs.
Recirculation / extraction mode**yesyes
Annual energy consumption (AEC _hood )20.6 kWh/year
Energy efficiency category***A
Fluid dynamical efficiency (FDE _hood )21.10
Fluid dynamical efficiency categoryC
Lighting efficiency (LE _hood )68.5 lux/W
Lighting efficiency categoryA
Grease separation74.9 %
Grease separation categoryD
Air flow ****152 m ^3 /h294 m ^3 /h
Air flow during operation at intensive-
A-rated noise emission ****53 dB63 dB
A-rated noise emission during operation at intensive or rapid operation setting-
Connected load62.00 W
Lighting systemLED
Power consumption lighting system (Wi)2.00 W
Power consumption per illuminant1*2.00 W
Voltage / frequencyAC 220 – 240 V / 50 Hz
Grease filter / material / dishwasher-proof1 aluminium yes
Carbon filter ****2*CF150 / optionally available
Supplied accessories: exhaust hoseyes
Supplied accessories: one-way valveyes
Supplied accessories: installation materialyes
Supplied accessories: instruction manualyes
Recirculation kit (recirculating air turnout)optionally available
Telescopic chimney extractable from-to40.00 - 78.00 cm
Total height incl. telescopic chimney107.50 cm
Dimensions: appliance H*W*D in cm29.50 - 107.50*60.00*26.30
Weight net / gross in kg9.50 / 10.00

◆ Technical modifications reserved.

*According to Regulation (EU) No. 65/2014
**Extraction mode: installation with ventilation stack or air duct outwards only, wall penetration = ∅ 150 mm, drilling approx. 153 mm ∅.
***On a scale from A+++ (highest) to D (lowest).
****Measured values at minimum / maximum motor speed.
*****Optional equipment.

9. Waste management

  1. While unpacking, the packaging materials (polythene bags, polystyrene pieces, etc.) should be kept away from children and pets. CHOKING HAZARD!
  2. Old and unused appliances must be sent for disposal to the responsible recycling centre. Never expose to open flames.
  3. Before you dispose of an old appliance, render it inoperative. Unplug the appliance and cut off the entire power cord. Dispose of the power cord and the plug immediately.
  4. Dispose of any paper and cardboard into the corresponding containers.
  5. Dispose of any plastics into the corresponding containers.
  6. If suitable containers are not available at your residential area, dispose of these materials at a suitable municipal collection point for waste-recycling.
  7. Receive more detailed information from your retailer or your municipal facilities.

PKM BS38-60 ABPH - Waste management - 1

Materials marked with this symbol are recyclable.

PKM BS38-60 ABPH - Waste management - 2

Please contact your local authorities to receive further information.

10. Guarantee conditions

This appliance includes a 24-month guarantee for the consumer given by the manufacturer, dated from the day of purchase, referring to its flawless material-components and its faultless fabrication. The consumer is accredited with both the dues of the guarantee given by the manufacturer and the vendor's guarantees. These are not restricted to the manufacturer's guarantee.

Any guarantee claim has to be made immediately after the detection and within 24 months after the delivery to the first ultimate vendee. The guarantee claim has to be verified by the vendee by submitting a proof of purchase including the date of purchase and/or the date of delivery.

The guarantee does not establish any entitlement to withdraw from the purchase contract or for a price reduction. Replaced components or exchanged appliances demise to us as our property.

The guarantee claim does not cover:

  1. fragile components as plastic, glass or bulbs;
  2. minor modifications of the PKM-products concerning their authorised condition if they do not influence the utility value of the product;
  3. damage caused by handling errors or false operation;
  4. damage caused by aggressive environmental conditions, chemicals, detergents;
  5. damage caused by non-professional installation and haulage;
  6. damage caused by non common household use;
  7. damages which have been caused outside the appliance by a PKM-product unless a liability is forced by legal regulations.

The validity of the guarantee will be terminated if:

  1. the prescriptions of the installation and operation of the appliance are not observed.
  2. the appliance is repaired by a non-professional.
  3. the appliance is damaged by the vendor, the installer or a third party.
  4. the installation or the start-up is performed inappropriately.
  5. the maintenance is inadequately or incorrectly performed.
  6. the appliance is not used for its intended purpose.
  7. the appliance is damaged by force majeure or natural disasters, including, but with not being limited to fires or explosions.

The guarantee claims neither extend the guarantee period nor initiate a new guarantee period. The geographical scope of the guarantee is limited with respect to appliances, which are purchased and used in Germany, Austria, Belgium, Luxembourg and the Netherlands.

Please contact the shop you purchased the appliance at.

Table of contents Click a title to access it
Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : PKM

Model : BS38-60 ABPH

Category : Range hood