9095-1438 - Kitchen scale Fasett - Free user manual and instructions
Find the device manual for free 9095-1438 Fasett in PDF.
| Product Type | Kitchen Scale |
| Brand | Fasett |
| Model | 9095-1438 |
| Power Source | 1x CR2032 battery (included) |
| Capacity | 5 kg / 11 lb |
| Precision | 1 g / 0.1 oz |
| Tare Function | Yes |
| Auto-Off | Yes, after 2 minutes of inactivity |
| Platform Material | Stainless steel |
| Display | LCD, white backlight |
| Units | g, kg, oz, lb |
| Dimensions (L x W x H) | 20 x 15 x 2 cm |
| Weight | 200 g |
| Color | Silver / Black |
| Overload Protection | Yes, displays 'EEEE' |
| Low Battery Indicator | Yes |
| Included Accessories | Scale, battery, user manual |
| Cleaning | Wipe with damp cloth; do not immerse |
| Warranty | 1 year limited |
Frequently Asked Questions - 9095-1438 Fasett
User questions about 9095-1438 Fasett
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
Download the instructions for your Kitchen scale in PDF format for free! Find your manual 9095-1438 - Fasett and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. 9095-1438 by Fasett.
USER MANUAL 9095-1438 Fasett
text_image
fasett Zero Chemistry Weight Milk Water WOODSEENG NO

Thank you for choosing to purchase a product from Rusta!

Read through the entire manual before installation and use!
Kitchen scale
FUNCTIONS
- Specifi es the volume of water and milk.
- Two units of weight can be selected - grams (g) or pounds (lb).
- Two units of volume can be selected - millilitres (ml) or fl uid ounces (fl).
- Long battery life. Indicates overloading.
• Highly precise weight sensor. - Net weight and reset function.
- Turns off automatically.
The kitchen scale is intended for use in households or household-like environments, for example, in kitchenettes in hotel or motel rooms, bed and breakfasts, common areas in campsites or other environments where food preparation occurs.
The scale is sensitive to extremes of temperature. Variations may occur if the scale is cold and therefore it works best at normal room temperature.
BATTERY
• 1 x lithium battery CR2032, 3V
REPLACING THE BATTERY
- Remove the battery cover and open the battery compartment on the underside of the scale.
- Remove the used battery.
- The new battery must be activated before the scale can be used. Carefully remove the black plastic flap. Let the scale adjust to the room temperature before using.
- Insert the new battery so that it is secure - remember to set the battery poles correctly.
- Put the battery cover back on.
- The battery should be replaced when the display shows "Low".

text_image
3V CR2032 +
text_image
Black plastic fl ap ContactENVIRONMENTAL CONSIDERATIONS FOR DISPOSAL OF BATTERIES
- When disposing of batteries, it is necessary to think of the environment. Used batteries should never be disposed of with household waste, but should be submitted to battery collection stations.
- The batteries should always be removed before the device is disposed of.
• Make sure that the batteries are not too old and used, since there is a risk that they will leak. Check the shelf life dates on the batteries and remove the batteries before they get too old.

text_image
LCD DISPLAY Net weight Negative value Weight 0 Weight Milk volume T 18.000 g ml o 18.000 g fl'oz lb:oz Weight Milk Water Weight Milk Water Weight Milk volume Water volume Weight unit (g) Volume unit (ml) Volume unit (fl ) Weight unit (lb) Water volumeBUTTON FOR CHANGING UNITS
- The button to change the unit is on the underside of the scale.

natural_image
Simple line drawing of a two-pin electronic component (no text or symbols)- Press the MODE button and choose the setting: weight, milk volume or water volume.
- Then press the button to change the unit and select the desired weight and volume unit. When grams (g) are selected as the weight unit, the volume will be in millilitres (ml). When pounds (lb) are selected, the volume will be in fluid ounces (fl).

text_image
Cr#OFF ZERO 0 g Weight Milk Water MODR Cr#OFF ZERO 0.00 Weight Milk Water MODRENG
WEIGHING
- Place the scale on a flat, stable surface.
- For exact weight, place the weighing pan or object to be weighed in the middle of the scale.

flowchart
graph TD
A["Device with weights and water"] --> B["Device with 0° milk water"]
B --> C["Device with 11° milk water"]
C --> D["Device with 11 ml water"]
WEIGHT MODE
- Place the weighing pan (if you want to use it) on the scale before you turn on the scale.
- Press the ON/OFF button to go to weight mode.
- Wait until the display shows all the information.
- Put the object to be weighed on the scale. The display shows the weight.
- If you are weighing milk or water, press the MODE button and select volume mode. The display shows the volume of the weighed liquid.
VOLUME MODE
- Press the ON/OFF button to go to turn on the scale.
- Wait until the display shows "0".
- Press the MODE button and select "Water" or "Milk" mode.
- Put an empty container on the scale.
- Press the ZERO button to reset the display to "0".
- Pour the liquid (water or milk) in the container. The display shows the volume of the liquid.
- Press the MODE button and select weight mode to see the liquid's weight.

flowchart
graph TD
A["Weight"] --> B["0 dB"]
B --> C["87 dB"]
C --> D["T - 0 dB"]
D --> E["587 dB"]
E --> F["605°"]
RESET AND NET WEIGHT FUNCTION
- The reset function is used to weigh objects one after another without needing to remove the previous object from the scale.
- Put the object on the scale and read the weight.
- Press the ZERO button to reset the display to "0" before adding the next object to the scale.
- Weighing can be repeated if more objects are added.

text_image
ZERO 9° Weight Milk Water 0° Weight Milk Water- Condition 1, reset function: If the total weight is < 4% of the scale's maximum weight capacity (4% =80g if the capacity is 2000g, and 200g if the capacity is 5000g).
- The display shows"----"or "0g" each time the ZERO button is pressed. ----"means that the scale is not stable. Wait until it stabilises. "0g" (eventually also displays the icon "o" in the lower left corner of the display) means that the reset function is active. The maximum weight capacity is unchanged.
- Condition 2, net weight function: If the total weight is >4% of the scale's maximum weight capacity (4% =80g if the capacity is 2000g, and 200 g if the capacity is 5000g).
- The display shows "----" or "0g" each time the ZERO button is pressed. "" means that the scale is not stable. Wait until it stabilises. "0g" (eventually also displays the icon "o" in the lower left corner of the display) means that the net weight function is active. The maximum weight capacity decreases with the total weight of the weighed objects.
- Under these conditions, press the ZERO button to see all objects' total weight. If you want to weigh more objects, press the ZERO button to reset the display to "0".

text_image
535° Weight Milk Water T 0° Weight Milk Water T 68° Weight Milk Water 603° Weight Milk Water T 0° Weight Milk Water ZEROENG
AUTOMATIC SHUTOFF
- Automatically turns off if the display shows "0" or if the same weight is shown for 2 minutes.

flowchart
graph TD
A["9°"] --> B["2 mins"]
B --> C[" "]
MANUAL SHUTOFF
- Extend the battery's life by turning off the scale (press the ON/OFF button). - Note: When the display shows "0", press the ON/OFF button to turn on the scale. When the display shows the weight, press the ON/OFF button and hold it down for 3 seconds to turn off the scale.

text_image
ON/OFFWARNING SYMBOLS ON THE DISPLAY

text_image
1 lo 2 Err Replace battery The scale is overloaded. Remove some objects from the scale. The scale is then ready for a new weighing.- This scale's weight capacity is 5kg. If overloaded, the display shows "EEEE".?
CLEANING AND MAINTENANCE
- Wipe the scale with a slightly damp cloth. Do not immerse the scale in water or other liquid. Do not use chemicals or abrasive cleaning agents.
- All plastic parts should be cleaned immediately after contact with grease, spices, vinegar or highly spicy or colourful foods. Avoid contact with citric acid.
• Always place the scale on a flat, stable surface. Do not place the scale on a mat.
TECHNICAL DATA
| Slim design 14mm | |
| Tempered glass plate | 3mm thick |
| LCD display | |
| Units g/lb | |
| Capacity Max 5kg with | 1g accuracy |
| Battery 1 x CR-2032, 3V (included) | |
| Reset and net weight function between weighings | |
| Automatically turns off after about 120 seconds. | |

natural_image
Simple line drawing of a U-shaped electronic component (no text or symbols)text_image
Cr-Off ZERO Weight 0 g Milk Water MOR Cr-Off ZERO Weight 0.00 Milk Water MORSE
VÄGNING
flowchart
graph TD
A["Device with weights and water"] --> B["Control panel: 0g weight, milk, water"]
B --> C["Display screen: 77g weight, milk, water"]
C --> D["Display screen: 77ml weight, milk, water"]
VIKTLÄGE
text_image
ZERO - 9° Weight Milk Water 0° - 0° Weight Milk Watertext_image
535° Weight Milk Water T 0° Weight Milk Water T 68° Weight Milk Water 603° Weight Milk Water T 0° Weight Milk WaterSE
AUTOMATISK AVSTÄNGNING
text_image
9° 2 minsMANUELL AVSTÄNGNING
natural_image
Simple line drawing of a two-pin electronic component (no text or symbols)text_image
OFF ZERO Weight Milk Water MODE OFF ZERO 0 9 0 00 Milk Water MODE 0 00 Milk WaterNO
VEIING
flowchart
graph TD
A["Device with weights and water"] --> B["Control panel: 0g weight, milk, water"]
B --> C["Display screen: 77g weight, milk, water"]
C --> D["Display screen: 77ml weight, milk, water"]