Eta

Fenité 8347 90000 - Epilator Eta - Free user manual and instructions

Find the device manual for free Fenité 8347 90000 Eta in PDF.

📄 76 pages English EN Download 💬 AI Question 10 questions ⚙️ Specs
Notice Eta Fenité 8347 90000 - page 31
View the manual : Čeština CS English EN Magyar HU Polski PL Slovenčina SK
Pick your language and provide your email: we'll send you a specifically translated version.
Product Type IPL Epilator with Skin Rejuvenation
Brand Eta
Model Fenité 8347 90000
Dimensions (with attachment) 185 x 155 x 80 mm
Weight 0.2 kg
Power Supply Adapter input: 100-240 V~ 50/60 Hz; Rechargeable Li-ion battery
Light Spectrum 510-1100 nm
Application Area Approx. 4 cm²
Intensity Levels 5 levels
Modes Manual and automatic
Attachments Hair Removal (HR) and Skin Rejuvenation (SR)
Display LCD with attachment indicator, intensity level, and flash count
Safety Features Skin contact sensor, auto shut-off after 8 seconds (manual) or 5 minutes inactivity, safety eyewear included
Treatment Frequency Once a week for first 2 months, then gradually decreasing to once a month, then 1-2 times a year
Cleaning Wipe device with soft damp cloth; clean attachment window with dry soft cloth; do not immerse
Storage In original packaging, dry and dust-free place, out of reach of children
Contraindications Not for use by persons under 18, pregnant/breastfeeding, with certain medical conditions or very dark skin
Noise Level 37 dB(A) re 1pW
Repairability Service only by authorized personnel; replacement attachments available (HR: ETA834700010, SR: ETA834700020, safety eyewear: ETA834700030)
Warranty Manufacturer's warranty subject to proper use and safety instructions

Frequently Asked Questions - Fenité 8347 90000 Eta

How does IPL epilation work?
IPL (Intense Pulsed Light) technology emits light pulses that are absorbed by the dark pigment (melanin) in hair, heating the hair root and destroying its cells. The hair then sheds naturally within 1-2 weeks. It is most effective on light to medium skin with dark hair.
Who should not use this device?
The device must not be used by children, persons under 18, pregnant or breastfeeding women, or individuals with certain medical conditions such as epilepsy, diabetes, lupus, skin cancer, photosensitivity, or implanted medical devices like pacemakers. Also avoid use on very dark skin, tanned skin, or over tattoos, moles, or open wounds.
Can I use the device on my face?
Yes, with the facial attachment (SR), but only for women aged 25 and above. Avoid the upper lip and nostril area. Always use the lowest intensity and close your eyes or look away during flashes.
What is the recommended treatment schedule?
For the first two months, use once a week. In the third month, use twice a month. From the fourth month to one year, use once a month. After one year, use 1-2 times a year as needed. Do not treat the same area more than once a week.
What should I do before using the device?
Shave the area to be treated, clean it thoroughly without any cosmetic products, and perform a skin tolerance test on a small area at least 24 hours before full treatment. Remove all metal objects and avoid alcohol-based products.
How do I clean and maintain the device?
After each use, let the device cool down. Wipe the surface with a soft damp cloth. Clean the attachment window with a dry soft cloth. Never immerse in water. Store in a dry place out of reach of children.
What are possible side effects?
Common side effects include mild pain, slight redness, dryness, and itching, which usually resolve within a few hours to days. Rare side effects may include burns, blisters, discoloration, or inflammation. If severe reactions occur, stop use and consult a doctor.
Can I use the device on tanned skin?
No. Avoid using on recently tanned or artificially tanned skin. After treatment, protect the skin from sunlight for at least 2-3 weeks with SPF 30+ sunscreen.
How long does it take to see results?
Results vary individually. Some may see initial effects after 4 weeks, while others may need up to 12-18 months for full effect. Regular use according to the schedule is essential.
What is the difference between the two attachments?
The yellow attachment (HR) is for hair removal. The red attachment (SR) is for skin rejuvenation, which stimulates collagen production to improve skin texture, reduce wrinkles, and unify skin tone. Do not use the SR attachment on individuals under 25.

User questions about Fenité 8347 90000 Eta

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Epilator in PDF format for free! Find your manual Fenité 8347 90000 - Eta and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. Fenité 8347 90000 by Eta.

USER MANUAL Fenité 8347 90000 Eta

natural_image White hairless spray gun with a digital display and two smaller product containers (no visible text or symbols)

1
B1 HR B2 B3 A1

A3 B A6 A C1 C3 C4 A2 A4 C C2 A5

Eta Fenité 8347 90000 - 3

natural_image Two electronic devices: a white power plug connected to a cable and a black pair of eyeglasses labeled E and D (no text or symbols on the devices themselves)

CLICK

IPL epilátor

eta 8347

Fenité

NÁVOD K OBSLUZE

Before using this device, please read carefully following instructions, including all contraindications, warnings and safety information and keep them for later use.

Due to its specific technology, the device is not suitable for everyone. The most effectively it works on light to medium skin tones and dark hair. Therefore, please get familiarized with following information, including the skin tone and hair colour tables, to make sure that its use is suitable and safe for your skin.

I. SAFETY WARNING

Eta Fenité 8347 90000 - SAFETY WARNING - 1

- Before the first use, read the instructions for use carefully, look at the picture and keep the instructions for use.

- Check whether the data on the type label correspond with the voltage in your socket.

- This appliance must not be used by children. Keep the device and its supply cord out of reach of children. The device may be used by persons with reduced physical or mental abilities or lack of experience and knowledge only if they are under supervision or they have been instructed about using the appliance safely and understand the potential dangers. Children must not play with the appliance.

- Before replacing accessories or accessible parts, before assembly and disassembly, before cleaning or maintenance, turn off the appliance and disconnect it from the mains by pulling the charger from the power socket!

- Do not leave the iron plugged in power supply without supervision!

- If the power cord of the charger is corrupted, it has to be replaced by the manufacturer, its service technician or a similarly qualified person so as to prevent dangerous situations.

- Never operate this device if its adapter, cord, plug, attachments or their glass filters are damaged, if it does not work properly, if it has been dropped and damaged, or dropped into water. In such cases bring the device to an authorized service centre to have its safety and proper operation examined.

- The appliance with the plugged adapter must not be used at places where it could fall into a bath tub, a wash basin or a swimming pool. If the appliance fell to water anyway, do not take it out! First of all, unplug the adapter from the socket and only then remove the appliance. In this case take the appliance to a special service to check its safety and proper function.

- Always unplug the appliance from charger if you leave it unattended.

- For additional protection we recommend installation of current protection (RCD) with the nominal release current not exceeding 30 mA. Ask a control technician or an electrician for advice.

- WARNING – Certain parts of the device (glass filters of the attachments) may become very hot and cause burns. Do not touch them during operation. Special attention should be paid to the presence of children or persons with reduced physical, sensory or mental capabilities.

- Considering hormonal and other changes in puberty, the device is not intended for use by persons under 18 years of age.

- Facial attachment C2 is suitable for persons above 25 years of age. However, younger persons, due to growth dynamics and hormonal changes, are not recommended to use this attachment!

- Never switch on the device without the attachment placed. Do not use the attachment if the glass filter, which forms its integral part, is missing. At the same time, check regularly, if the glass filter is not damaged.

- Do not use the device for any other surface than human skin (excluding forbidden areas). Also do not use it, if the application window is not in contact with your skin.

- Leave the ventilation slots free and in no way block or cover them during the operation. Ensure good circulation of air in the room.

- Use the device only with the intensity setting, which is suitable for your skin tone/type (see below). If a higher intensity than that allowed Is used, the risk of side effects and undesired reactions of the skin may increase.

- To prevent the risk of skin injury, do not treat the same area with flashes (nor if changing the attachments!) more than once a week. Do not treat the same area with more flashes during one session. Repeated treatment due to different hair growth stages does not improve the effectiveness of epilation (as well as the treatment with facial attachment) but occurs the risk of skin damage.

- Never look directly at the flash produced by the device (at the glass filter); nor try to switch on the device when pointing to eyes, even with safety eyewear on.

- Never use the device, if small children or toddlers are present in the room! The light produced may be unpleasant to them.

- Before epilation, it is necessary to remove all metal objects, such as rings, bracelets, necklets, piercings etc. You must not use any cosmetic products or, for example, make-up pencils containing metal to mark the places to be treated! Do not use it, for example, for lips contoured with a permanent or semi-permanent contour pencil.

- Before use, never clean the areas to be treated with agents containing alcohol (alcohol, acetone etc.).

- In any case of activation (flashing) of the device, even if the touch sensor with application window is not in contact with the skin, do not use the device and have it examined by an authorized service centre.

- The device is intended for use at home and for similar purposes! It is not designed for use in cosmetic salons or for any other commercial purposes!

- Do not put or take out the plug to or from a socket with wet hands!

- Never immerse the device, its attachments or adapter in water or other liquids (nor partially), do not expose them to moist and do not wash them under the tap!

- Use only the accessories designed for this type. Do not use damaged adapters.

  • The appliance must not be used in damp or wet environment and in any environment with the danger of fire or explosion (spaces where chemicals, fuels, oils, gases, paints and other flammable or volatile materials are stored).
  • The power cord of the adapter must not be damaged with sharp or hot objects, open fire and it must not be sunk into water.
  • The adaptor supplied with this appliance is intended for this appliance only, do not use it for other purposes. Also, use only the supplied adaptor with this appliance, do not use any other adaptor for charging (e.g. from another appliance).
  • Never use the appliance for any other purpose than for the intended purpose described in these instructions for use!
  • The producer is not responsible for any loss caused by improper handling of the appliance and its accessories (e. g. injury, appliance damage, fire, etc.) and its guarantee for the appliance does not apply in the case of non-compliance with the safety instructions above.

II. CONTRAINDICATIONS AND SPECIFICS OF USE

Contraindications

This type of device is unique with the IPL technology used. It allows to bring the high professional effectiveness to the comfort of your home. However, this technology has some limitations and specifics of use – it is not intended for all groups of persons and it cannot be used under certain circumstances or in case of certain diseases.

VERY IMPORTANT

Any failure to follow the instructions and recommendations given here may result in skin damage, aggravation of possible current problems, or occurring of adverse side effects, such as burns, blisters, discolorations or scarification of the skin.

If you have any doubts concerning the use of the device in your individual case consult your dermatologist or general practitioner first! Further, in case of your long-term (in certain cases also short-term) use of certain medication (or hormonal contraception), ask if they may not influence the sensitivity of your skin to light and heat and thus negatively influence the skin reaction to IPL treatment!

The device must not be used by:

– Children and elder persons;
– Persons with local or systemic inflammatory disease;
- Persons with implanted medical devices and systems (such as pacemaker, skin ports etc.).
- Persons with precancerous lesions or several atypical moles on the area to be treated with the device.
- Persons with skin diseases (e.g. skin cancer, psoriasis, vitiligo), with medical history of skin cancer or any other focal lesions of cancer localised on the areas of intended use of the device or the persons currently being treated with chemotherapy or radiotherapy.
- Persons with photosensitive skin or taking photosensitizing medication;
- Persons with any chronic disease, heart disease, thyroid gland disease, further the persons with the diseases such as lupus erythematosus, diabetes, epilepsy or retina disease or receiving an immunosuppressive therapy.
– Pregnant or breastfeeding women or women attempting to conceive.

The device has not been tested for this group of persons.

Further, do not use the device in following cases:

  • If the skin on the area to be treated has been treated with peeling, sunburned, cut, has open wounds, eczemas, lesions, haematomas, burns, inflammation of hair follicles, abrasions or is currently being treated with injections or if you have had a surgery or facial rejuvenation surgery in given area (such as Botox, facial filler, thread lifts etc.).
  • If you have varicose veins, dilated veins or a history of any other vascular disorder on the area to be treated.
  • If you have a history of collagen disorder, including a history of keloid scar formation or a history of poor wound healing, or you have skin implants.
  • If you have any bleeding disorder; also, if you use anticoagulation medications.
  • Over or near silicone implants or piercings.
  • Immediately after cosmetic treatment (e.g. after AHA, botulotoxin treatment etc.).
    – If you visit tanning centre.
  • In moles (neither near them nor over them!), freckles, darker pigmented areas, scars or other skin irregularities.
  • If you have warts, freckles, tattoos or permanent make-up on the area to be treated
  • If you have used long-lasting deodorant on the area to be epilated.
  • If your skin tone is very dark (see part "Skin type „below"). The dark skin absorbs more light energy, which may result in unpleasant or painful sensation and undesired effects (e.g. burning, blisters formation, discoloration or scarification) and damage to skin.
  • If your skin is very sensitive.
  • If you suffer from solar urticaria (allergy to sun).
  • Before or shortly after IPL application, do not use any cosmetic products (e.g. products with pigments, perfumes, alcohol etc.).
  • In any other case which would be considered by your doctor as risky for the use of this device.

The above-mentioned lists are not complete and do not include all possible cases and complications, that may exclude the use of IPL technology. In case of any doubts you should contact your dermatologist or general practitioner.

Further, special attention should be paid to the issue of tanning. Do not use the device on recently tanned or artificially tanned skin! All types of tanning (natural, as well as artificial one, including the use of self-tanners) may reduce the safety of IPL treatment, as the skin becomes very sensitive. Do not use also if you are planning to travel soon e.g. to the sea and to get exposed to the sunlight. It applies also vice versa - after IPL treatment, do not expose your unprotected skin to any tanning or sunlight for at least 2-3 weeks. Regarding the above-mentioned, it is not recommended to use the device in summer months (or in days with increased sunlight, regardless the season of the year), when people are generally very often exposed to the sunlight.

Skin type

IPL technology has its advantages and limitations. One of the main factors, determining the resulting effect and the safety of use of the IPL device, is the skin tone and the colour of hair. To put it simply, the best results are achieved by the persons with light skin and dark hair. The darker the hair, the more energy from the flashes is absorbed, making the epilation more effective. However, the darker skin tone is less desirable from the point of view of the safety in case of skin discoloration.

Therefore, the device is not intended for use by the persons with very dark skin tone, as there is a risk of skin injury (e.g. burning). If your skin tone is very dark, do not use the device.

If you have a darker skin tone (and before using the device for the first time) always start the epilation at the lowest intensity. Only after you make sure that given setting does not cause any complications, you can increase the light intensity setting, if needed.

Please also note that IPL device is not effective in persons with light blond, white, red or grey hair, since due to the low level of dark pigment in this case, the effectiveness of the epilation may be very low.

Hair colourSkin tone type
1 2 34 5 6
BlackEta Fenité 8347 90000 - Skin type - 1Eta Fenité 8347 90000 - Skin type - 2Eta Fenité 8347 90000 - Skin type - 3Eta Fenité 8347 90000 - Skin type - 4Eta Fenité 8347 90000 - Skin type - 5x
Dark brownEta Fenité 8347 90000 - Skin type - 6Eta Fenité 8347 90000 - Skin type - 7Eta Fenité 8347 90000 - Skin type - 8Eta Fenité 8347 90000 - Skin type - 9Eta Fenité 8347 90000 - Skin type - 10x
BrownEta Fenité 8347 90000 - Skin type - 11Eta Fenité 8347 90000 - Skin type - 12Eta Fenité 8347 90000 - Skin type - 13Eta Fenité 8347 90000 - Skin type - 14Eta Fenité 8347 90000 - Skin type - 15x
Dark blond /light brownEta Fenité 8347 90000 - Skin type - 16Eta Fenité 8347 90000 - Skin type - 17Eta Fenité 8347 90000 - Skin type - 18Eta Fenité 8347 90000 - Skin type - 19Eta Fenité 8347 90000 - Skin type - 20Eta Fenité 8347 90000 - Skin type - 21Eta Fenité 8347 90000 - Skin type - 22Eta Fenité 8347 90000 - Skin type - 23Eta Fenité 8347 90000 - Skin type - 24Eta Fenité 8347 90000 - Skin type - 25x
Light blond x x x x x x
Red x x x x x xEta Fenité 8347 90000 - Skin type - 26Eta Fenité 8347 90000 - Skin type - 27Eta Fenité 8347 90000 - Skin type - 28Eta Fenité 8347 90000 - Skin type - 29
White / grey x x x x x x xEta Fenité 8347 90000 - Skin type - 30Eta Fenité 8347 90000 - Skin type - 31Eta Fenité 8347 90000 - Skin type - 32Eta Fenité 8347 90000 - Skin type - 33

Eta Fenité 8347 90000 - Skin type - 34

Eta Fenité 8347 90000 - Skin type - 35

Eta Fenité 8347 90000 - Skin type - 36

Eta Fenité 8347 90000 - Skin type - 37

Eta Fenité 8347 90000 - Skin type - 38

Eta Fenité 8347 90000 - Skin type - 39

Eta Fenité 8347 90000 - Skin type - 40

Eta Fenité 8347 90000 - Skin type - 41

Eta Fenité 8347 90000 - Skin type - 42

Eta Fenité 8347 90000 - Skin type - 43

Eta Fenité 8347 90000 - Skin type - 44

Eta Fenité 8347 90000 - Skin type - 45

Eta Fenité 8347 90000 - Skin type - 46

Eta Fenité 8347 90000 - Skin type - 47

Eta Fenité 8347 90000 - Skin type - 48

Eta Fenité 8347 90000 - Skin type - 49

Eta Fenité 8347 90000 - Skin type - 50

Eta Fenité 8347 90000 - Skin type - 51

Eta Fenité 8347 90000 - Skin type - 52

Eta Fenité 8347 90000 - Skin type - 53

Eta Fenité 8347 90000 - Skin type - 54

Eta Fenité 8347 90000 - Skin type - 55

Eta Fenité 8347 90000 - Skin type - 56

Eta Fenité 8347 90000 - Skin type - 57

Eta Fenité 8347 90000 - Skin type - 58

Eta Fenité 8347 90000 - Skin type - 59

Eta Fenité 8347 90000 - Skin type - 60

Eta Fenité 8347 90000 - Skin type - 61

Eta Fenité 8347 90000 - Skin type - 62

Eta Fenité 8347 90000 - Skin type - 63

Eta Fenité 8347 90000 - Skin type - 64

Eta Fenité 8347 90000 - Skin type - 65

Eta Fenité 8347 90000 - Skin type - 66

Eta Fenité 8347 90000 - Skin type - 67

Eta Fenité 8347 90000 - Skin type - 68

Eta Fenité 8347 90000 - Skin type - 69

Eta Fenité 8347 90000 - Skin type - 70

Eta Fenité 8347 90000 - Skin type - 71

Eta Fenité 8347 90000 - Skin type - 72

Eta Fenité 8347 90000 - Skin type - 73

Eta Fenité 8347 90000 - Skin type - 74

Eta Fenité 8347 90000 - Skin type - 75

Eta Fenité 8347 90000 - Skin type - 76

Eta Fenité 8347 90000 - Skin type - 77

Eta Fenité 8347 90000 - Skin type - 78

Eta Fenité 8347 90000 - Skin type - 79

Eta Fenité 8347 90000 - Skin type - 80

Eta Fenité 8347 90000 - Skin type - 81

Eta Fenité 8347 90000 - Skin type - 82

Eta Fenité 8347 90000 - Skin type - 83

Eta Fenité 8347 90000 - Skin type - 84

Eta Fenité 8347 90000 - Skin type - 85

Eta Fenité 8347 90000 - Skin type - 86

Eta Fenité 8347 90000 - Skin type - 87

Eta Fenité 8347 90000 - Skin type - 88

Eta Fenité 8347 90000 - Skin type - 89

Eta Fenité 8347 90000 - Skin type - 90

Eta Fenité 8347 90000 - Skin type - 91

Eta Fenité 8347 90000 - Skin type - 92

Eta Fenité 8347 90000 - Skin type - 93

Eta Fenité 8347 90000 - Skin type - 94

Eta Fenité 8347 90000 - Skin type - 95

Eta Fenité 8347 90000 - Skin type - 96

Eta Fenité 8347 90000 - Skin type - 97

Eta Fenité 8347 90000 - Skin type - 98

Eta Fenité 8347 90000 - Skin type - 99

Eta Fenité 8347 90000 - Skin type - 100

Eta Fenité 8347 90000 - Skin type - 101

Eta Fenité 8347 90000 - Skin type - 102

Eta Fenité 8347 90000 - Skin type - 103

Eta Fenité 8347 90000 - Skin type - 104

Eta Fenité 8347 90000 - Skin type - 105

Eta Fenité 8347 90000 - Skin type - 106

Eta Fenité 8347 90000 - Skin type - 107

Eta Fenité 8347 90000 - Skin type - 108

Eta Fenité 8347 90000 - Skin type - 109

Eta Fenité 8347 90000 - Skin type - 110

Eta Fenité 8347 90000 - Skin type - 111

Eta Fenité 8347 90000 - Skin type - 112

Eta Fenité 8347 90000 - Skin type - 113

Eta Fenité 8347 90000 - Skin type - 114

Eta Fenité 8347 90000 - Skin type - 115

Eta Fenité 8347 90000 - Skin type - 116

Eta Fenité 8347 90000 - Skin type - 117

Eta Fenité 8347 90000 - Skin type - 118

Eta Fenité 8347 90000 - Skin type - 119

Eta Fenité 8347 90000 - Skin type - 120

Eta Fenité 8347 90000 - Skin type - 121

Eta Fenité 8347 90000 - Skin type - 122

Eta Fenité 8347 90000 - Skin type - 123

Eta Fenité 8347 90000 - Skin type - 124

Eta Fenité 8347 90000 - Skin type - 125

Eta Fenité 8347 90000 - Skin type - 126

Eta Fenité 8347 90000 - Skin type - 127

Eta Fenité 8347 90000 - Skin type - 128

Eta Fenité 8347 90000 - Skin type - 129

Eta Fenité 8347 90000 - Skin type - 130

Eta Fenité 8347 90000 - Skin type - 131

Eta Fenité 8347 90000 - Skin type - 132

Eta Fenité 8347 90000 - Skin type - 133

Eta Fenité 8347 90000 - Skin type - 134

Eta Fenité 8347 90000 - Skin type - 135

Eta Fenité 8347 90000 - Skin type - 136

Eta Fenité 8347 90000 - Skin type - 137

Eta Fenité 8347 90000 - Skin type - 138

Eta Fenité 8347 90000 - Skin type - 139

Eta Fenité 8347 90000 - Skin type - 140

Eta Fenité 8347 90000 - Skin type - 141

Eta Fenité 8347 90000 - Skin type - 142

Eta Fenité 8347 90000 - Skin type - 143

Eta Fenité 8347 90000 - Skin type - 144

Eta Fenité 8347 90000 - Skin type - 145

Eta Fenité 8347 90000 - Skin type - 146

Eta Fenité 8347 90000 - Skin type - 147

Eta Fenité 8347 90000 - Skin type - 148

Eta Fenité 8347 90000 - Skin type - 149

Eta Fenité 8347 90000 - Skin type - 150

Eta Fenité 8347 90000 - Skin type - 151

Eta Fenité 8347 90000 - Skin type - 152

Eta Fenité 8347 90000 - Skin type - 153

Eta Fenité 8347 90000 - Skin type - 154

Eta Fenité 8347 90000 - Skin type - 155

Eta Fenité 8347 90000 - Skin type - 156

Eta Fenité 8347 90000 - Skin type - 157

Eta Fenité 8347 90000 - Skin type - 158

Eta Fenité 8347 90000 - Skin type - 159

Eta Fenité 8347 90000 - Skin type - 160

Eta Fenité 8347 90000 - Skin type - 161

Eta Fenité 8347 90000 - Skin type - 162

Eta Fenité 8347 90000 - Skin type - 163

Eta Fenité 8347 90000 - Skin type - 164

Eta Fenité 8347 90000 - Skin type - 165

Eta Fenité 8347 90000 - Skin type - 166

Eta Fenité 8347 90000 - Skin type - 167

Eta Fenité 8347 90000 - Skin type - 168

Eta Fenité 8347 90000 - Skin type - 169

Eta Fenité 8347 90000 - Skin type - 170

Eta Fenité 8347 90000 - Skin type - 171

Eta Fenité 8347 90000 - Skin type - 172

Eta Fenité 8347 90000 - Skin type - 173

Eta Fenité 8347 90000 - Skin type - 174

Eta Fenité 8347 90000 - Skin type - 175

Eta Fenité 8347 90000 - Skin type - 176

Eta Fenité 8347 90000 - Skin type - 177

Eta Fenité 8347 90000 - Skin type - 178

Eta Fenité 8347 90000 - Skin type - 179

Eta Fenité 8347 90000 - Skin type - 180

Eta Fenité 8347 90000 - Skin type - 181

Eta Fenité 8347 90000 - Skin type - 182

Eta Fenité 8347 90000 - Skin type - 183

Eta Fenité 8347 90000 - Skin type - 184

Eta Fenité 8347 90000 - Skin type - 185

Eta Fenité 8347 90000 - Skin type - 186

Eta Fenité 8347 90000 - Skin type - 187

Eta Fenité 8347 90000 - Skin type - 188

Eta Fenité 8347 90000 - Skin type - 189

Eta Fenité 8347 90000 - Skin type - 190

Eta Fenité 8347 90000 - Skin type - 191

Eta Fenité 8347 90000 - Skin type - 192

Eta Fenité 8347 90000 - Skin type - 193

Eta Fenité 8347 90000 - Skin type - 194

Eta Fenité 8347 90000 - Skin type - 195

Eta Fenité 8347 90000 - Skin type - 196

Eta Fenité 8347 90000 - Skin type - 197

Eta Fenité 8347 90000 - Skin type - 198

Eta Fenité 8347 90000 - Skin type - 199

Eta Fenité 8347 90000 - Skin type - 200

Eta Fenité 8347 90000 - Skin type - 201

Eta Fenité 8347 90000 - Skin type - 202

Eta Fenité 8347 90000 - Skin type - 203

Eta Fenité 8347 90000 - Skin type - 204

Eta Fenité 8347 90000 - Skin type - 205

Eta Fenité 8347 90000 - Skin type - 206

Eta Fenité 8347 90000 - Skin type - 207

Eta Fenité 8347 90000 - Skin type - 208

Eta Fenité 8347 90000 - Skin type - 209

Eta Fenité 8347 90000 - Skin type - 210

Eta Fenité 8347 90000 - Skin type - 211

Eta Fenité 8347 90000 - Skin type - 212

Eta Fenité 8347 90000 - Skin type - 213

Eta Fenité 8347 90000 - Skin type - 214

Eta Fenité 8347 90000 - Skin type - 215

Eta Fenité 8347 90000 - Skin type - 216

Eta Fenité 8347 90000 - Skin type - 217

Eta Fenité 8347 90000 - Skin type - 218

Eta Fenité 8347 90000 - Skin type - 219

Eta Fenité 8347 90000 - Skin type - 220

Eta Fenité 8347 90000 - Skin type - 221

Eta Fenité 8347 90000 - Skin type - 222

Eta Fenité 8347 90000 - Skin type - 223

Eta Fenité 8347 90000 - Skin type - 224

Eta Fenité 8347 90000 - Skin type - 225

Eta Fenité 8347 90000 - Skin type - 226

Eta Fenité 8347 90000 - Skin type - 227

Eta Fenité 8347 90000 - Skin type - 228

Eta Fenité 8347 90000 - Skin type - 229

Eta Fenité 8347 90000 - Skin type - 230

Eta Fenité 8347 90000 - Skin type - 231

Eta Fenité 8347 90000 - Skin type - 232

Eta Fenité 8347 90000 - Skin type - 233

Eta Fenité 8347 90000 - Skin type - 234

Eta Fenité 8347 90000 - Skin type - 235

Eta Fenité 8347 90000 - Skin type - 236

Eta Fenité 8347 90000 - Skin type - 237

Eta Fenité 8347 90000 - Skin type - 238

Eta Fenité 8347 90000 - Skin type - 239

Eta Fenité 8347 90000 - Skin type - 240

Eta Fenité 8347 90000 - Skin type - 241

Eta Fenité 8347 90000 - Skin type - 242

Eta Fenité 8347 90000 - Skin type - 243

Eta Fenité 8347 90000 - Skin type - 244

Eta Fenité 8347 90000 - Skin type - 245

Eta Fenité 8347 90000 - Skin type - 246

Eta Fenité 8347 90000 - Skin type - 247

Eta Fenité 8347 90000 - Skin type - 248

Eta Fenité 8347 90000 - Skin type - 249

Eta Fenité 8347 90000 - Skin type - 250

Eta Fenité 8347 90000 - Skin type - 251

Eta Fenité 8347 90000 - Skin type - 252

Eta Fenité 8347 90000 - Skin type - 253

Eta Fenité 8347 90000 - Skin type - 254

Eta Fenité 8347 90000 - Skin type - 255

Eta Fenité 8347 90000 - Skin type - 256

Eta Fenité 8347 90000 - Skin type - 257

Eta Fenité 8347 90000 - Skin type - 258

Eta Fenité 8347 90000 - Skin type - 259

Eta Fenité 8347 90000 - Skin type - 260

Eta Fenité 8347 90000 - Skin type - 261

Eta Fenité 8347 90000 - Skin type - 262

Eta Fenité 8347 90000 - Skin type - 263

Eta Fenité 8347 90000 - Skin type - 264

Eta Fenité 8347 90000 - Skin type - 265

Eta Fenité 8347 90000 - Skin type - 266

Eta Fenité 8347 90000 - Skin type - 267

Eta Fenité 8347 90000 - Skin type - 268

Eta Fenité 8347 90000 - Skin type - 269

Eta Fenité 8347 90000 - Skin type - 270

Eta Fenité 8347 90000 - Skin type - 271

Eta Fenité 8347 90000 - Skin type - 272

Eta Fenité 8347 90000 - Skin type - 273

Eta Fenité 8347 90000 - Skin type - 274

Eta Fenité 8347 90000 - Skin type - 275

Eta Fenité 8347 90000 - Skin type - 276

Eta Fenité 8347 90000 - Skin type - 277

Eta Fenité 8347 90000 - Skin type - 278

Eta Fenité 8347 90000 - Skin type - 279

Eta Fenité 8347 90000 - Skin type - 280

Eta Fenité 8347 90000 - Skin type - 281

Eta Fenité 8347 90000 - Skin type - 282

Eta Fenité 8347 90000 - Skin type - 283

Eta Fenité 8347 90000 - Skin type - 284

Eta Fenité 8347 90000 - Skin type - 285

Eta Fenité 8347 90000 - Skin type - 286

Eta Fenité 8347 90000 - Skin type - 287

Eta Fenité 8347 90000 - Skin type - 288

Eta Fenité 8347 90000 - Skin type - 289

Eta Fenité 8347 90000 - Skin type - 290

Eta Fenité 8347 90000 - Skin type - 291

Eta Fenité 8347 90000 - Skin type - 292

Eta Fenité 8347 90000 - Skin type - 293

Eta Fenité 8347 90000 - Skin type - 294

Eta Fenité 8347 90000 - Skin type - 295

Eta Fenité 8347 90000 - Skin type - 296

Eta Fenité 8347 90000 - Skin type - 297

Eta Fenité 8347 90000 - Skin type - 298

Eta Fenité 8347 90000 - Skin type - 299

Eta Fenité 8347 90000 - Skin type - 300

Eta Fenité 8347 90000 - Skin type - 301

Eta Fenité 8347 90000 - Skin type - 302

Eta Fenité 8347 90000 - Skin type - 303

  • On particularly sensitive areas (such as ankles, bony areas etc.)
  • On the areas you wish to have hair on in the future.

Moreover, men must not use the device on the face, neck and on the beard (as a variation of shaving machine or beard trimmer). In such case (the beard or facial hair) the epilation may result in lasting effects - uneven results, which may cause undesirable changes in characteristic facial features.

Hair removal using IPL technology may cause increased hair growth in some individuals. Based on the data available, the highest risk areas are the facial and neck ones, and it concerns rather women of Mediterranean, Middle Eastern and South Asian types.

Dear customers, please also note that regarding the specific principle of IPL technology operation and an individual character of human organism response, the seller cannot guarantee the full extent of the effects of the device (epilation, as well as rejuvenation functions). There may be a group of individuals, in which IPL treatment is less effective than in other. The period, within which the primary effect can be seen, may also be very individual – from approx. 4 weeks up to need to repeat the treatment in approx. 12-18 months.

Areas suitable for treatment
face around lips back underarms chest arms abdomen bikini area thighs legs

III. FUNCTIONS OF DEVICE

The product is delivered with two attachments – yellow epilation attachment for hair removal and red attachment for skin rejuvenation (sometimes also photo-rejuvenation).

EPILATION

How does the IPL epilation work?

If used properly, the IPL technology (intensive pulses of light) epilation allows to achieve long-lasting effect and to prevent the regrowth of the hair. It is achieved by heating the hair and its root under the surface of the skin – the emitted light is absorbed, leading to destruction of their cells without damaging surrounding tissues. Consequently, the hair sheds within 1-2 weeks (Note: there may an impression of hairs continuing to grow, but they are only pushed out and then they fall out naturally) and its further regrowth on given area is prevented. If any new hairs occur (e.g. due to age or hormonal changes), they are fine and soft, and their density is reduced.

The major role plays the dark pigment (melanin), which can absorb the flashes of the light. The darker the hair is, the more amount of light it can absorb. That is why its use is not effective in light hair – as light hair absorbs only a minimum of light; majority of hair remains undamaged.

However, IPL epilation is only effective when the hairs are in their growing phase!

There are approximately 10-30 % of them at the time of the session (this is very variable, and it depends on the individual, as well as the part of the body). Therefore, an effective hair removal requires some patience and repeating the epilation in regular cycles within a prolonged period (see below).

SKIN REJUVENATION

The flashes during the treatment generate heat inside the skin, stimulating the creation of collagen, which improves the elasticity and smoothness of the skin. At the same time, the heat treatment positively influences undesirable hormonal pigmentation (acquired, for example, during pregnancy), small veins, and smoothens various scars. The colour of the skin is unified to certain extent, its texture improved, the wrinkles are partially smoothened and overall freshness and vitality of the skin is improved.

For whom is the photorejuvenation suitable?

Due to hormonal changes, the attachment for rejuvenation is not recommended for use by persons under 25 years of age. However, always consider your overall health condition and respect the warnings given in these instructions. Also, do not use the attachment to unify the areas of pigmentation with other than hormonal cause (e.g. pigmented nevi). If you have any doubts concerning the use on your specific pigmented areas, always consult your physician or dermatologist first.

IV. DEVICE AND ACCESSORIES DESCRIPTION (picture 1)

A – IPL epilator

A1 – ON./OFF button./flash intensity adjustment
A2 – light activation button
A3 – air vent grate
A4 – air intake grate
A5 – device socket
A6 – light-signalling of scanning

B - LCD display

B1 – marking of placed attachment
B2 - set flash intensity
B3 – remaining amount of flashed (longevity) of the attachment

C – IPL attachments

C1 – hair removal attachment (HR); (order code ETA834700010)
C2 – skin rejuvenation attachment (SR); (order code ETA834700020)
C3 – application window with protection filter
C4 – skin sensor

D – Safety eyewear (obj. kód ETA834700030)

E - Adapter

V. INSTRUCTION FOR USE

PREPARING FOR USE

To achieve optimal results, it is advisable to pre-treat the areas you wish to use the device on.

A) Pre-treatment of the skin on the area to be treated

1) Remove hair on the surface of the area in usual way (e.g. by shaving); if you have been recently epilated by a method including root removal, before using IPL, wait until the hair regrows. Using IPL technology on the areas, which are not hair-free, may result in undesired effects. e.g. burning of hair accompanied by smell, or contamination or damage to the application window.
2) Wash the skin, make sure it is free from any cosmetic products, perfumes etc. and let it dry.
3) Check, and, if needed, clean the application window with protection filter C3. It must not be contaminated with caught hairs, dust or any other impurities.

B) Setting the light intensity

The device provides 5 different pulsed light intensities. The IPL method is more effective in higher intensity settings. However, individual specifics of each person need to be considered in accordance with the rules/warnings given in the instructions. If you have darker skin tone, use lower intensity setting (see part “Skin type” above). As well, if you experience any discomfort or pain in any part of your body, reduce the intensity.

After switching on the device, you can change the pulsed light intensity by pressing A1 button. The degree set is displayed by respective number of lines B2 on the display B.

NOTE

Light impulse may cause a sensation of warmth or heat. In some cases, your skin may also slightly tingle. However, it should never be painful.

C) Setting

Based on the warnings in these instructions, evaluate, if your current health and skin condition allow the use of this device.

HOW TO USE

Skin tolerance test

Before using the device for the first time (regardless the intensity degree) it is necessary to perform the tolerance test on a small skin area. It will help you to verify, if this type of technology is well tolerated by you and to discover any possible unwanted reaction of your skin. The test should be performed at least 24 before a complete treatment.

The tested area should be hair-free, clean and free from any cosmetic products.

Then release 2-3 flashes close to each other at a low intensity of 1-2. Wait 24 hours and check your skin for any unwanted reactions (erythema, the skin must not be sensitive or swollen, nor you should experience any discomfort). If any complications occur, do not use the device and for further actions consult your physician/dermatologist.

After having performed the skin test, do not perform any treatment on the tested area for at least one week (by any of the attachments).

Modes of use

2 basic modes of the use of the device are available.

a) manual - it is a default mode, which can be simply described as a mode when each flash of light must be induced by pressing activaton button A2. Use for more precise treatment of your face or other, rather small, parts of your body.

Proper contact with your skin and the possibility to release a flash is signalled by flashing A6 signal lamp and C4 sensor. If the application window is not in proper contact with your skin, the A6 signal lamp and C4 sensor are lit.

b) automatic - in this mode you can just press the application window C3 onto your skin with no need to press the activation A2 button. Then the flash releases in certain intervals will be activated automatically. It is suitable for treatment of larger areas.

Active mode is signalled by continuous flashing of A6 signal lamp and C4 sensor. Once the application window gets close to the skin, the flashes start to be released automatically.

After switching on the device, the automatic mode is activated by pressing and holding the A2 button for 2 seconds. The switch-over is signalled by an acoustic signal. Use the same procedure for switching the device back to the manual mode.

WARNING

  • At lower levels of setting, the intervals between the flashes (or heating the lamp) are very short. If you operate in the automatic mode, you must continuously slide the light exit window, to prevent multiple flashes on the same area.
  • When the device is switched off and then switched on again, it is activated in the mode in which it was switched off. However, if the device has been unplugged, when switched on again, it is activated in the default manual mode.
  • For safety reasons, if the application window does not move, if in manual mode, the release of flashes will be automatically interrupted after 8 seconds.

Using the device

1) Select and by simple snapping place the selected attachment. If the device is switched on without an attachment placed on it, the HR and SR will flash on the display B signalling the missing attachment. To remove the attachment, use the same procedure (see the detail on the picture 1).
2) Put the connector of the adapter to the device socket A5. Then put the adapter in the wall socket. The sign "OFF" will be lit on the display and an audible signal will sound. Now the device is in a standby mode.
3) To switch on the device, press and long hold the button A1. An audible signal will sound, the integrated vent will be activated, and the display will be lit, indicating the marking of the attachment placed (HR or SR), the flash intensity set and numeric indication of the amount of remaining flashes for given attachment
4) If needed, change the flash intensity setting and the mode of use.
5) Put on the safety eyewear D.
6) Press the device onto the skin area to be treated. In automatic mode, the flashes will be released immediately. Thus, it is necessary to continuously slide the application window to the next area, so there is only a partial overlap and always move to the new area of the skin. In manual mode, press and release the application button A2 to release a flash.
7) When you have finished the treatment, press and long hold the button A1 to switch off the device and unplug the adapter from the wall socket. In case of inactivity lasting for more than 5 minutes, the device will be switched off automatically. Then let the device and the attachment cool down. Then perform routine maintenance and store the device in well-ventilated place out of reach of children and persons with reduced mental capabilities.

Skin care after use

Approximately 20 minutes after the treatment, you can apply moisturizers or regenerative lotions to the treated area. If you experience discomfort or skin irritation, you can calm the area by applying a cooling cloth (for 30-60 minutes). Do not use irritating cosmetic products! Do not moist the treated area with water for approximately 2 hours after the treatment.

Tips and advice on use

  • Do not miss a place – release the flashes close to each other.
  • When treating the face (women only!), more attanetion should be paid, as the skin in this area is very sensitive. Before application, close your eyes or look away (even with safety eyewear) and avoid releasing double flash on the same area. When treating the area over the upper lip, avoid the contact with lips and nostrils, which may be particularly sensitive.
  • It is not recommended to use the device in a dark room. At a reduced light levels the flashes are more distinctive and may be exhausting to your eyes.
  • During the treatment (but not during the session!) and for at least two weeks after the last treatment, protect your skin against sunlight using sunblocks SPF 30 and higher.
  • Do not bath in disinfected pools etc. for at least 2 days.
  • If a stronger skin reaction than a slight redness occurs, interrupt the use of the device and read "POSSIBLE SIDE EFFECTS".

TREATMENT SCHEDULE

Since the resulting effectiveness of the IPL epilator may vary between different individuals, please note that the length of successful treatment period may also differ. One will need only few treatments (lasting e.g. for 2 months), another will need a year or more.

During the use, follow the treatment frequency as per following rules:

1st and 2nd month – use once a week.

3rd month – use 2 times a month (approx. after 15 days)

4th month – 1 year – use once a month

After 1 year – 1-2 times a year, if needed

VI. POSSIBLE SIDE EFFECTS

In principle, all methods of epilation and cosmetic interventions to a human body may cause some adverse effects. IPL technology is not an exclusion. These are mostly common reactions, which disappear within few hours/days. In case of more severe reactions (e.g. excessive redness or more intensive pain as a result of not following the rules in these instructions (mainly as a result of setting a high intensity, repeated application on the same area or application on a skin which is not hair-free) it is necessary to interrupt the treatment, evaluate the correctness of the procedure in accordance with the rules in the instructions and in case of any doubts or unusual skin reaction consult the further use of the device with your dermatologist or physician.

Common and harmless side effects:

- Mild pain – pain is perceived differently by different people. Under normal circumstances, the treatment with IPL device should not be painful. However, regarding different pain thresholds, it is possible that some people may experience certain discomfort (e.g. burning, prickle, tingling). But the pain should not be intensive and should disappear quickly. If you experience an excessive discomfort or pain at lower settings, do not use the device and consult your physician/dermatologist.

  • Slight redness – this reaction is relatively common and in most cases it disappears quickly. It may occur immediately or within 24 hours after the treatment. The skin may show similar reaction as after sunburn. It is recommended to perform the treatment before sleep, so the possible redness does not interfere with your daily routine. However, if the problems persist for more than approx. 3 days, consult the further use of the device with your physician/dermatologist.
  • Smell of burnt hairs – it usually occurs if you have not removed your hair before use and the flash burned the upper part of hairs above the skin surface. In such case stop using the device and remove hair from the treated areas.
  • Sensation of dryness and itching – especially in combination with mechanical hair removal. It is common and it will disappear within few days. You can ease the symptom (but not immediately after use!) using a non-scented moisturizer.

Rare side effects:

  • burns, excessive redness or swelling – often as a result of using a light intensity that too high for your skin tone.
  • discoloration - it may manifest itself as either a darker patch or a lighter patch than the surrounding area. This also often occurs as a result of using the intensity that is too high for your skin tone.
  • Skin inflammation – various infections and inflammations, that may occur after using the device on wounded areas (e.g. by shaving) or on ingrown hairs.

If the above-mentioned problems (excessive redness, discoloration, inflammation around hair follicle) do not disappear within 3 days, consult your doctor – some problems may be induced by other causes constituting a separate health problem. Do not use the device until your skin regenerates or restores its original colour.

VII. MAINTENANCE

To ensure an optimal condition of the device, clean it regularly after each session (or during the treatment, if needed). Neglecting the maintenance may lead to reduced effectiveness of the device.

Before performing maintenance, let the device and the attachment used cool down. Do not use abrasive, aggressive or flammable cleaning products! Wipe the surface of the device with a soft moist cloth. Check the vent slots and, if needed, remove e.g. caught hairs or other impurities. After each use, check the used attachment and its application window for any impurities caught on it. To clean the attachment and the application window, use only a dry soft cloth, not shedding fibre. The device itself and its attachments must not be washed or immersed in water or other liquids!

Storage

Put the appliance with the accessories back to the original package at a dry and dust free place, out of reach of children and incapacitated people. Ensure the protection of the application window with glass filter against damage.

VIII. ENVIRONMENTAL PROTECTION

Eta Fenité 8347 90000 - ENVIRONMENTAL PROTECTION - 1

If the dimensions allow, there are marks of materials used for production of packing, components and accessories as well as their recycling on all parts. The symbols specified on the product or in the accompanying documentation mean that the used electrical or electronic products must not be disposed of together with municipal waste. For proper disposal, hand them over at the special collection places where they will be received free of charge. Suitable disposal of the product can help to maintain valuable natural resources and to prevent possible negative impacts on the environment and human health, which could be the possible consequences of improper waste disposal. Ask for more details at the local authorities or at a collection site. Fines can be afflicted for improper disposal of this type of waste in agreement with the national regulations. The appliance is equipped with rechargeable Li-ion batteries with long life. Dispose of the batteries in a suitable and safe way through the special collection networks. Never dispose of the batteries by burning!

More extensive maintenance or maintenance requiring intervention in the inner parts of the appliance must be carried out by professional service! Failure to comply with the instructions of the manufacturer will lead to expiration of the right to guarantee repair!

IX. TECHNICAL DATA

Voltage (V) specified on the type label

Trimmer weight (kg) 0.2

Appliance Protection Class III.

Adapter Protection Class II.

Dimensions (h x l x w) 185 x 155 x 80 mm (with attachment)

Application area approx 4 cm

Light spectrum 510-1100 nm

Noise level: Acoustic noise level of 37 db (A) re 1pW.

The manufacturer reserves the right to change the technical specifications and accessories for the respective models.

HOUSEHOLD USE ONLY. DO NOT IMMERSE IN WATER OR OTHER LIQUIDS.

Eta Fenité 8347 90000 - TECHNICAL DATA - 1

Eta Fenité 8347 90000 - TECHNICAL DATA - 2

TO AVOID DANGER OF SUFFOCATION, KEEP THIS PLASTIC BAG AWAY FROM BABIES AND CHILDREN. DO NOT USE THIS BAG IN CRIBS, BEDS, CARRIAGES OR PLAYPENS. THIS BAG IS NOT A TOY.

Eta Fenité 8347 90000 - TECHNICAL DATA - 3

NOTICE

Eta Fenité 8347 90000 - NOTICE - 1

Do not use the appliance close to bath tubs, showers, bash basins or other water containers.

IPL epilátor

eta 8347

Fenité

KEZELÉSI ÚTMUTATÓ

TO AVOID DANGER OF SUFFOCATION, KEEP THIS PLASTIC BAG

AWAY FROM BABIES AND CHILDREN. DO NOT USE THIS BAG IN

CRIBS, BEDS, CARRIAGES OR PLAYPENS. THIS BAG IS NOT A TOY.

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : Eta

Model : Fenité 8347 90000

Category : Epilator