| A Supplier's name - | Samsung Electronics Co., Ltd. | Samsung Electronics Co., Ltd. | Samsung Electronics Co., Ltd. | Samsung Electronics Co., Ltd. | ||
| B | Model name (Indoor/Outdoor) | - | AR09FSFPESNN / AR09FSFPESNX | AR12FSFPESNN / AR12FSFPESNX | AR18FSFPESNN / AR18FSFPESNX | AR24FSFPESNN / AR24FSFPESNX |
| C | Sound Power Level (Inside/Outside) | dBA 56 / 59 57 / 62 57 / | 65 62 / 67 | |||
| D Refrigerant name 1) | -R-410A R-410A R-410A R-410A | |||||
| EWP - 1975 1975 1975 1975 | ||||||
| F SEER 5.6 5.6 6.7 6.1 | ||||||
| G | Energy efficiency class (SEER) | - | A+ | A+ | A++ | A++ |
| H | QCE21(cooling season) | kWh/a | 156 | 219 | 261 | 390 |
| I | Pdesignc | kW | 2.5 | 3.5 | 5.0 | 6.8 |
| J | SCOP | - | 3.8 3.8 3.8 | 3.8 | ||
| K | Energy efficiency class (SCOP) | - | A | A | A | A |
| L | QHE31(heating season) | kWh/a | 921 | 1105 | 1658 | 2063 |
| M | Other heating seasons suitable for use | - | Warmer and Colder Season | Warmer and Colder Season | X | X |
| N | Pdesignh (Average) | kW | 2.5 | 3.0 | 4.5 | 5.6 |
| O | elbu(Tj) (Average) | kW | 0 | 0 | 0 | 0 |
| P | Pdesignh (Warner) | kW | 2.5 | 3.0 | X | X |
| Q | elbu(Tj) (Warner) | kW | 0 | 0 | X | X |
| R | Pdesignh (Colder) | kW | 2.5 | 3.0 | X | X |
| S | elbu(Tj) (Colder) | kW | 1.82 | 2.22 | X | X |
| T | Declared capacity at reference design conditions | kW | 2.5 3.0 | 4.5 5.6 | ||
| U | Assumed backup heating capacity | kW 0 | 0 | 0 | 0 | |
1) Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere. This appliance contains a refrigerant fluid with a GWP equal to [xxx].
This means that if 1 kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be [xxx] times higher than 1 kg of CO_2 , over a period of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional.
2) Energy consumption "XYZ" kWh per year, based on standard test results. Actual energy consumption will depend on how the appliance is used and where it is located.
3) Energy consumption "XYZ" kWh per year, based on standard test results. Actual energy consumption will depend on how the appliance is used and where it is located.
DB68-03546A(3)
Energy Labeling Information(AC product)
According to Commission Regulation (EU) No 626/2011
| A Supplier's name - | Samsung Electronics Co., Ltd. | Samsung Electronics Co., Ltd. | Samsung Electronics Co., Ltd. | Samsung Electronics Co., Ltd. | |
| B | Model name (Indoor/Outdoor) | - | AR09FSFPDGMN / AR09FSFPDGMX | AR12FSFPDGMN / AR12FSFPDGMX | AR18FSFPDGMN / AR18FSFPDGMX |
| C | Sound Power Level (Inside/Outside) | dBA 54 / 59 56 / 62 57 / 65 62 / 67 | |||
| D Refrigerant name 1) | -R-410A R-410A R-410A R-410A | ||||
| E GWP - 1975 1975 1975 1975 | |||||
| F SEER 5.1 5.1 6.7 6.1 | |||||
| G | Energy efficiency class (SEER) | -A A A++ | A++ | ||
| H | Qcc2)(cooling season) | kWh/a | 172 240 261 | 390 | |
| I Pdesignc kW 2.5 3.5 | 5.0 6.8 | ||||
| J | SCOP | - | 3.4 3.4 3.8 | 3.8 | |
| K | Energy efficiency class (SCOP) | -A A A A | |||
| L | Q HE3)(heating season) | kWh/a | 1029 1153 | 1658 2063 | |
| M | Other heating seasons suitable for use | - | Warmer Season | Warmer Season | X |
| N | Pdesignh (Average) | kW | 2.5 2.8 4.5 | 5.6 | |
| O | elbu(Tj) (Average) | kW | 0 | 0 | 0 |
| P | Pdesignh (Warmer) | kW | 2.5 | 2.8 | X |
| Q | elbu(Tj) (Warmer) | kW | 0 | 0 | X |
| R | Pdesignh (Colder) | kW | X | X | X |
| S | elbu(Tj) (Colder) | kW | X | X | X |
| T | Declared capacity at reference design conditions | kW | 2.5 2.8 4.5 | 5.6 | |
| U | Assumed backup heating capacity | kW | 0 | 0 | 0 |
1) Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere. This appliance contains a refrigerant fluid with a GWP equal to [xxx].
This means that if 1 kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be [xxx] times higher than 1 kg of CO₂, over a period of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional.
2) Energy consumption "XYZ" kWh per year, based on standard test results. Actual energy consumption will depend on how the appliance is used and where it is located.
3) Energy consumption "XYZ" kWh per year, based on standard test results. Actual energy consumption will depend on how the appliance is used and where it is located.
Energy Labeling Information(AC product)
According to Commission Regulation (EU) No 626/2011
| A Supplier's name - Samsung Electronics Co., Ltd. | ||||
| B | Model name (Indoor/Outdoor) | - | AR09FSFPKGMN / AR09FSFPKGMX | AR12FSFPKGMN / AR12FSFPKGMX |
| C | Sound Power Level (Inside/Outside) | dBA 54 / 59 56 / 62 | ||
| D Refrigerant name 1) | -R-4 | 10A R-410A | ||
| E GWP - 1975 1975 | ||||
| F SEER 5.6 | 5.6 | |||
| G | Energy efficiency class (SEER) | - | A+ | A+ |
| H | Qcc2)(cooling season) | kWh/a | 156 | 219 |
| I | Pdesignc | kW | 2.5 | 3.5 |
| J | SCOP | - | 3.4 | 3.4 |
| K | Energy efficiency class (SCOP) | - | A | A |
| L | QHE3)(heating season) | kWh/a | 1029 1153 | |
| M | Other heating seasons suitable for use | - | Warmer Season | Warmer Season |
| N | Pdesignh (Average) | kW | 2.5 | 2.8 |
| O | elbu(Tj) (Average) | kW | 0 | 0 |
| P | Pdesignh (Warmer) | kW | 2.5 | 2.8 |
| Q | elbu(Tj) (Warmer) | kW | 0 | 0 |
| R | Pdesignh (Colder) | kW | X | X |
| S | elbu(Tj) (Colder) | kW | X | X |
| T | Declared capacity at reference design conditions | kW | 2.5 | 2.8 |
| U | Assumed backup heating capacity | kW | 0 | 0 |
1) Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere. This appliance contains a refrigerant fluid with a GWP equal to [xxx].
This means that if 1 kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be [xxx] times higher than 1 kg of CO₂, over a period of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional.
2) Energy consumption "XYZ" kWh per year, based on standard test results. Actual energy consumption will depend on how the appliance is used and where it is located.
3) Energy consumption "XYZ" kWh per year, based on standard test results. Actual energy consumption will depend on how the appliance is used and where it is located.
[ESPANOL][FRANÇAIS][ITALIANO]
Warmer and Colder Season
[ESPANOL]: Temporada mas calida
Warmer and Colder Season
Warmer and Colder Season
[ROMÁNÀ]: Sezon mai cald Şi mai rece
[BbIAPCKN]:No-toTbnI nO-xlaJeH ce3OH
HRVATSKI: Toplija i hladnijasezona
[SRPSKI] [POLSKI] [
MAGYAR
| A Naziv proizvodača A Nazwa dostawcy A Szállító neve | ||||
| B | Naziv modela (unutrašnji/ spojašnji) | B | Nazwa modelu (wewnétrzny/ zewnétrzny) | B Típus neve (beltéri/kultéri) |
| C Nivo snage zvuka (unutra/spolja) C | Poziom hałasu (wewnétrz/na zewnétrz) | C Hangnyomásszint (beltéri/kultéri) | ||
| D Naziv sredstva za hladenje 1) | D Nazwa czynnika chlodźęcego 1) | D Hútǒközeg neve 1) | ||
| E GWP E GWP E GWP | ||||
| F SEER F SEER F SEER | ||||
| G | Klasa energetske efikasnosti (SEER) | G Klasa energooszcżednosci (SEER) G | Energiahatékonysús angi osztátly (SEER) | |
| H | Qe2(sezona hladenja) HQ | CE2(sezon chlodniczy) HQ | CE2(hútési idény) | |
| I PDizajnc | I Pdesignc | I Pdesignc | ||
| J | SCOP | J SCOP | J | SCOP |
| K | Klasa energetske efikasnosti (SCOP) | K Klasa energooszcżednosci (SCOP) | K | Energiahatékonysús angi osztátly (SCOP) |
| L | Qe3(sezona grejanja) | L Q HE3(sezon grzewczy) | L Q | HE3(fútési idény) |
| M | Drugesezone grejanja odgovarajuće za koriśćne | M Innesezony grzewcie oppowiednie do uzytkowania | M | Használatra alkalmas más fútési idények |
| N PDizajnh (prosek) | N Pdesignh (sredni) | N Pdesignh (Átlag) | ||
| O | Elbu (Tj) (prosek) | O elbu(Tj) (sredni) | O | elbu(Tj) (Átlag) |
| P PDizajnh (grejač) | P Pdesignh (cieplejszy) | P Pdesignh (Melegebb) | ||
| Q | Elbu (Tj) (grejač) | Q elbu(Tj) (cieplejszy) | Q | elbu(Tj) (Melegebb) |
| R | PDizajnh (hladnjak) | R Pdesignh (chlodniejszy) | R | Pdesignh (Hidegebb) |
| S | Elbu (Tj) (hladnjak) | S elbu(Tj) (chlodniejszy) | S | elbu(Tj) (Hidegebb) |
| T | Deklarisan kapacitet u referentnim dizajn uslovima | T Wydajnosć deklarowana w projektówych warunkach odniaśienia | T | Névleges teljesitmény tervezési referencia-környezetben |
| U | Prepostavljeni rezervni kapacitet grejanja | U Zakladana rezerwowa wydajnosć grzewca | U | Becsült rasegítő fútoteljesitmény |
Warmer Season
[SRPSKI]: Sezona greanja
Warmer and Colder Season
[SRPSKI]: Sezona greanja i hladenja