SAMSUNG AR09FSFPDGMX - Air Conditioning

AR09FSFPDGMX - Air Conditioning SAMSUNG - Free user manual and instructions

Find the device manual for free AR09FSFPDGMX SAMSUNG in PDF.

📄 14 pages English EN Download 💬 AI Question
Notice SAMSUNG AR09FSFPDGMX - page 1
View the manual : Français FR English EN
Pick your language and provide your email: we'll send you a specifically translated version.

User questions about AR09FSFPDGMX SAMSUNG

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Air Conditioning in PDF format for free! Find your manual AR09FSFPDGMX - SAMSUNG and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. AR09FSFPDGMX by SAMSUNG.

USER MANUAL AR09FSFPDGMX SAMSUNG

According to Commission Regulation (EU) No 626/2011

A Supplier's name -Samsung Electronics Co., Ltd.Samsung Electronics Co., Ltd.Samsung Electronics Co., Ltd.Samsung Electronics Co., Ltd.
BModel name (Indoor/Outdoor)-AR09FSFPESNN / AR09FSFPESNXAR12FSFPESNN / AR12FSFPESNXAR18FSFPESNN / AR18FSFPESNXAR24FSFPESNN / AR24FSFPESNX
CSound Power Level (Inside/Outside)dBA 56/ 59 57 / 62 57 /65 62 / 67
D Refrigerant name ^1) - R-410A R-410A R-410A R-410A
E GWP - 1975 1975 1975 1975
F SEER 5.6 5.6 6.7 6.1
GEnergy efficiency class (SEER)-A+A+A++A++
HQCE ^2) (cooling season)kWh/a156219261390
IPdesignckW2.53.55.06.8
JSCOP-3.8 3.8 3.83.8
KEnergy efficiency class (SCOP)-AAAA
LQHE ^3) (heating season)kWh/a921110516582063
MOther heating seasons suitable for use-Warmer and Colder SeasonWarmer and Colder SeasonXX
NPdesignh (Average)kW2.53.04.55.6
Oelbu(Tj) (Average)kW0000
PPdesignh (Warmer)kW2.53.0XX
Qelbu(Tj) (Warmer)kW00XX
RPdesignh (Colder)kW2.53.0XX
Selbu(Tj) (Colder)kW1.822.22XX
TDeclared capacity at reference design conditionskW2.5 3.04.5 5.6
UAssumed backup heating capacitykW 0000

1) Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere. This appliance contains a refrigerant fluid with a GWP equal to [xxx].
This means that if 1 kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be [xxx] times higher than 1 kg of CO₂, over a period of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional.
2) Energy consumption "XYZ" kWh per year, based on standard test results. Actual energy consumption will depend on how the appliance is used and where it is located.
3) Energy consumption "XYZ" kWh per year, based on standard test results. Actual energy consumption will depend on how the appliance is used and where it is located.

DB68-03546A(3)

Energy Labeling Information(AC product)

According to Commission Regulation (EU) No 626/2011

A Supplier's name -Samsung Electronics Co., Ltd.Samsung Electronics Co., Ltd.Samsung Electronics Co., Ltd.Samsung Electronics Co., Ltd.
BModel name (Indoor/Outdoor)-AR09FSFPDGMN / AR09FSFPDGMXAR12FSFPDGMN / AR12FSFPDGMXAR18FSFPDGMN / AR18FSFPDGMX
CSound Power Level (Inside/Outside)dBA 54 / 59 56 / 62 57 / 65 62 / 67
D Refrigerant name ^1) - R-410A R-410A R-410A R-410A
E GWP - 1975 1975 1975 1975
F SEER 5.1 5.1 6.7 6.1
GEnergy efficiency class (SEER)- A A A++A++
H Q_cc^2) (cooling season)kWh/a172 240 261390
I Pdesignc kW 2.5 3.5 5.0 6.8
JSCOP-3.4 3.4 3.83.8
KEnergy efficiency class (SCOP)- A A A A
L Q_HE^3) (heating season)kWh/a1029 11531658 2063
MOther heating seasons suitable for use-Warmer SeasonWarmer SeasonX
NPdesignh (Average)kW2.5 2.8 4.55.6
Oelbu(Tj) (Average)kW000
PPdesignh (Warmer)kW2.52.8X
Qelbu(Tj) (Warmer)kW00X
RPdesignh (Colder)kWXXX
Selbu(Tj) (Colder)kWXXX
TDeclared capacity at reference design conditionskW2.5 2.8 4.55.6
UAssumed backup heating capacitykW000

1) Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere. This appliance contains a refrigerant fluid with a GWP equal to [xxx].

This means that if 1 kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be [xxx] times higher than 1 kg of CO₂, over a period of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional.

2) Energy consumption "XYZ" kWh per year, based on standard test results. Actual energy consumption will depend on how the appliance is used and where it is located.

3) Energy consumption "XYZ" kWh per year, based on standard test results. Actual energy consumption will depend on how the appliance is used and where it is located.

Energy Labeling Information(AC product)

According to Commission Regulation (EU) No 626/2011

A Supplier's name - Samsung Electronics Co., Ltd.
BModel name(Indoor/Outdoor)-AR09FSFPKGMN / AR09FSFPKGMXAR12FSFPKGMN / AR12FSFPKGMX
CSound Power Level(Inside/Outside)dBA 54 / 59 56 / 62
D Refrigerant name ^1) -R-410A R-410A
E GWP - 1975 1975
F SEER 5.65.6
GEnergy efficiency class (SEER)-A+A+
H Q_CE^2) (cooling season)kWh/a156219
IPdesignckW2.53.5
JSCOP-3.43.4
KEnergy efficiency class (SCOP)-AA
L Q_HE^3) (heating season)kWh/a1029 1153
MOther heating seasons suitable for use-Warmer SeasonWarmer Season
NPdesignh (Average)kW2.52.8
Oelbu(Tj) (Average)kW00
PPdesignh (Warmer)kW2.52.8
Qelbu(Tj) (Warmer)kW00
RPdesignh (Colder)kWXX
Selbu(Tj) (Colder)kWXX
TDeclared capacity at reference design conditionskW2.52.8
UAssumed backup heating capacitykW00

1) Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere. This appliance contains a refrigerant fluid with a GWP equal to [xxx].

This means that if 1 kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be [xxx] times higher than 1 kg of CO₂, over a period of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional.

2) Energy consumption "XYZ" kWh per year, based on standard test results. Actual energy consumption will depend on how the appliance is used and where it is located.

3) Energy consumption "XYZ" kWh per year, based on standard test results. Actual energy consumption will depend on how the appliance is used and where it is located.

[ESPAÑOL][FRANÇAIS][ITALIANO]

Warmer and Colder Season

Warmer and Colder Season

Warmer and Colder Season

[SRPSKI] [POLSKI] [
MAGYAR

A Naziv proizvođača A Nazwa dostawcy A Szállító neve
BNaziv modela (unutrašnji/ spoljašnji)BNazwa modelu (wewnętrzny/ zewnętrzny)B Típus neve (beltéri/kültéri)
C Nivo snage zvuka (unutra/spolja) CPoziom hałasu (wewnątrz/na zewnątrz)C Hangnyomásszint (beltéri/kültéri)
D Naziv sredstva za hlađenje 1)D Nazwa czynnika chłodzącego 1)D Hútóközeg neve 1)
E GWP E GWP E GWP
F SEER F SEER F SEER
GKlasa energetske efikasnosti (SEER)G Klasa energooszczędności (SEER) GEnergiahatékonysági osztály (SEER)
HQCE2) (sezona hlađenja) H QCE2)(sezon chłodniczy) H QCE2)(hútési idény)
I PDizajncI PdesigncI Pdesignc
JSCOPJSCOPJSCOP
KKlasa energetske efikasnosti (SCOP)K Klasa energooszczędności (SCOP)KEnergiahatékonysági osztály (SCOP)
LQHE3) (sezona grejanja)L QHE3)(sezon grzewczy)L QHE3)(fútési idény)
MDruge sezone grejanja odgovarajuće za korišćenjeMInne sezony grzewcze odpowiednie do użytkowaniaMHasználatra alkalmas más fútési idények
N PDizajnh (prosek)N Pdesignh (średni)N Pdesignh (Átlag)
OElbu (Tj) (prosek)Oelbu(Tj) (średni)Oelbu(Tj) (Átlag)
P PDizajnh (grejač)P Pdesignh (cieplejszy)P Pdesignh (Melegebb)
QElbu (Tj) (grejač)Qelbu(Tj) (cieplejszy)Qelbu(Tj) (Melegebb)
RPDizajnh (hladnjak)RPdesignh (chłodniejszy)RPdesignh (Hidegebb)
SElbu (Tj) (hladnjak)Selbu(Tj) (chłodniejszy)Selbu(Tj) (Hidegebb)
TDeklarisan kapacitet u referentnim dizajn uslovimaTWydajność deklarowana w projektowych warunkach odniesieniaTNévleges teljesítmény tervezési referencia-környezetben
UPretpostavljeni rezervni kapacitet grejanjaUZakładana rezerwowa wydajność grzewczaUBecsült rasegítő fütőteljesítmény

Warmer Season

[SRPSKI]: Sezona grejanja

Warmer and Colder Season

Warmer and Colder Season

natural_image Color palette bar with grayscale shades and a central crosshair symbol (no text or labels)

SAMSUNG AR09FSFPDGMX - Warmer and Colder Season - 1

SAMSUNG AR09FSFPDGMX - Warmer and Colder Season - 2

Table of contents Click a title to access it
Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : SAMSUNG

Model : AR09FSFPDGMX

Category : Air Conditioning