USER MANUAL AR12FSFPDGMX SAMSUNG
According to Commission Regulation (EU) No 626/2011
| A Supplier's name - | Samsung Electronics Co., Ltd. | Samsung Electronics Co., Ltd. | Samsung Electronics Co., Ltd. | Samsung Electronics Co., Ltd. | ||
| B | Model name (Indoor/Outdoor) | - | AR09FSFPESNN / AR09FSFPESNX | AR12FSFPESNN / AR12FSFPESNX | AR18FSFPESNN / AR18FSFPESNX | AR24FSFPESNN / AR24FSFPESNX |
| C | Sound Power Level (Inside/Outside) | dBA 56 | / 59 57 / 62 57 / | 65 62 / 67 | ||
| D Refrigerant name ^1) | - R-4 | 10A R-410A R-410 | A R-410A | |||
| E GWP - 1975 1975 1975 1975 | ||||||
| F SEER 5.6 5.6 6.7 6.1 | ||||||
| G | Energy efficiency class (SEER) | - | A+ | A+ | A++ | A++ |
| H | QCE^2) (cooling season) | kWh/a | 156 | 219 | 261 | 390 |
| I | Pdesignc | kW | 2.5 | 3.5 | 5.0 | 6.8 |
| J | SCOP | - | 3.8 3.8 3.8 | 3.8 | ||
| K | Energy efficiency class (SCOP) | - | A | A | A | A |
| L | QHE^3) (heating season) | kWh/a | 921 | 1105 | 1658 | 2063 |
| M | Other heating seasons suitable for use | - | Warmer and Colder Season | Warmer and Colder Season | X | X |
| N | Pdesignh (Average) | kW | 2.5 | 3.0 | 4.5 | 5.6 |
| O | elbu(Tj) (Average) | kW | 0 | 0 | 0 | 0 |
| P | Pdesignh (Warmer) | kW | 2.5 | 3.0 | X | X |
| Q | elbu(Tj) (Warmer) | kW | 0 | 0 | X | X |
| R | Pdesignh (Colder) | kW | 2.5 | 3.0 | X | X |
| S | elbu(Tj) (Colder) | kW | 1.82 | 2.22 | X | X |
| T | Declared capacity at reference design conditions | kW | 2.5 3.0 | 4.5 5.6 | ||
| U | Assumed backup heating capacity | kW 0 | 0 | 0 | 0 | |
1) Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere. This appliance contains a refrigerant fluid with a GWP equal to [xxx].
This means that if 1 kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be [xxx] times higher than 1 kg of CO₂, over a period of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional.
2) Energy consumption "XYZ" kWh per year, based on standard test results. Actual energy consumption will depend on how the appliance is used and where it is located.
3) Energy consumption "XYZ" kWh per year, based on standard test results. Actual energy consumption will depend on how the appliance is used and where it is located.
DB68-03546A(3)
Energy Labeling Information(AC product)
According to Commission Regulation (EU) No 626/2011
| A Supplier's name - | Samsung Electronics Co., Ltd. | Samsung Electronics Co., Ltd. | Samsung Electronics Co., Ltd. | Samsung Electronics Co., Ltd. | |
| B | Model name (Indoor/Outdoor) | - | AR09FSFPDGMN / AR09FSFPDGMX | AR12FSFPDGMN / AR12FSFPDGMX | AR18FSFPDGMN / AR18FSFPDGMX |
| C | Sound Power Level (Inside/Outside) | dBA 54 / 59 56 / 62 57 / 65 62 / 67 | |||
| D Refrigerant name ^1) | - R-410A R-410A R-410A R-410A | ||||
| E GWP - 1975 1975 1975 1975 | |||||
| F SEER 5.1 5.1 6.7 6.1 | |||||
| G | Energy efficiency class (SEER) | - A A A++ | A++ | ||
| H | Q_cc^2) (cooling season) | kWh/a | 172 240 261 | 390 | |
| I Pdesignc kW 2.5 3.5 5.0 6.8 | |||||
| J | SCOP | - | 3.4 3.4 3.8 | 3.8 | |
| K | Energy efficiency class (SCOP) | - A A A A | |||
| L | Q_HE^3) (heating season) | kWh/a | 1029 1153 | 1658 2063 | |
| M | Other heating seasons suitable for use | - | Warmer Season | Warmer Season | X |
| N | Pdesignh (Average) | kW | 2.5 2.8 4.5 | 5.6 | |
| O | elbu(Tj) (Average) | kW | 0 | 0 | 0 |
| P | Pdesignh (Warmer) | kW | 2.5 | 2.8 | X |
| Q | elbu(Tj) (Warmer) | kW | 0 | 0 | X |
| R | Pdesignh (Colder) | kW | X | X | X |
| S | elbu(Tj) (Colder) | kW | X | X | X |
| T | Declared capacity at reference design conditions | kW | 2.5 2.8 4.5 | 5.6 | |
| U | Assumed backup heating capacity | kW | 0 | 0 | 0 |
1) Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere. This appliance contains a refrigerant fluid with a GWP equal to [xxx].
This means that if 1 kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be [xxx] times higher than 1 kg of CO₂, over a period of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional.
2) Energy consumption "XYZ" kWh per year, based on standard test results. Actual energy consumption will depend on how the appliance is used and where it is located.
3) Energy consumption "XYZ" kWh per year, based on standard test results. Actual energy consumption will depend on how the appliance is used and where it is located.
Energy Labeling Information(AC product)
According to Commission Regulation (EU) No 626/2011
| A Supplier's name - Samsung Electronics Co., Ltd. | ||||
| B | Model name(Indoor/Outdoor) | - | AR09FSFPKGMN / AR09FSFPKGMX | AR12FSFPKGMN / AR12FSFPKGMX |
| C | Sound Power Level(Inside/Outside) | dBA 54 / 59 56 / 62 | ||
| D Refrigerant name ^1) | -R-410A R-410A | |||
| E GWP - 1975 1975 | ||||
| F SEER 5.6 | 5.6 | |||
| G | Energy efficiency class (SEER) | - | A+ | A+ |
| H | Q_CE^2) (cooling season) | kWh/a | 156 | 219 |
| I | Pdesignc | kW | 2.5 | 3.5 |
| J | SCOP | - | 3.4 | 3.4 |
| K | Energy efficiency class (SCOP) | - | A | A |
| L | Q_HE^3) (heating season) | kWh/a | 1029 1153 | |
| M | Other heating seasons suitable for use | - | Warmer Season | Warmer Season |
| N | Pdesignh (Average) | kW | 2.5 | 2.8 |
| O | elbu(Tj) (Average) | kW | 0 | 0 |
| P | Pdesignh (Warmer) | kW | 2.5 | 2.8 |
| Q | elbu(Tj) (Warmer) | kW | 0 | 0 |
| R | Pdesignh (Colder) | kW | X | X |
| S | elbu(Tj) (Colder) | kW | X | X |
| T | Declared capacity at reference design conditions | kW | 2.5 | 2.8 |
| U | Assumed backup heating capacity | kW | 0 | 0 |
1) Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere. This appliance contains a refrigerant fluid with a GWP equal to [xxx].
This means that if 1 kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be [xxx] times higher than 1 kg of CO₂, over a period of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional.
2) Energy consumption "XYZ" kWh per year, based on standard test results. Actual energy consumption will depend on how the appliance is used and where it is located.
3) Energy consumption "XYZ" kWh per year, based on standard test results. Actual energy consumption will depend on how the appliance is used and where it is located.
[ESPAÑOL][FRANÇAIS][ITALIANO]
Warmer and Colder Season
Warmer and Colder Season
Warmer and Colder Season
[SRPSKI] [POLSKI] [
MAGYAR
| A Naziv proizvođača A Nazwa dostawcy A Szállító neve | |||||
| B | Naziv modela (unutrašnji/ spoljašnji) | B | Nazwa modelu (wewnętrzny/ zewnętrzny) | B Típus neve (beltéri/kültéri) | |
| C Nivo snage zvuka (unutra/spolja) C | Poziom hałasu (wewnątrz/na zewnątrz) | C Hangnyomásszint (beltéri/kültéri) | |||
| D Naziv sredstva za hlađenje 1) | D Nazwa czynnika chłodzącego 1) | D Hútóközeg neve 1) | |||
| E GWP E GWP E GWP | |||||
| F SEER F SEER F SEER | |||||
| G | Klasa energetske efikasnosti (SEER) | G Klasa energooszczędności (SEER) G | Energiahatékonysági osztály (SEER) | ||
| H | Q_CE^2) (sezona hlađenja) H Q | CE^2) (sezon chłodniczy) H Q | CE^2) (hútési idény) | ||
| I PDizajnc | I Pdesignc | I Pdesignc | |||
| J | SCOP | J | SCOP | J | SCOP |
| K | Klasa energetske efikasnosti (SCOP) | K Klasa energooszczędności (SCOP) | K | Energiahatékonysági osztály (SCOP) | |
| L | Q_HE^3) (sezona grejanja) | L Q | HE^3) (sezon grzewczy) | L Q | HE^3) (fútési idény) |
| M | Druge sezone grejanja odgovarajuće za korišćenje | M | Inne sezony grzewcze odpowiednie do użytkowania | M | Használatra alkalmas más fútési idények |
| N PDizajnh (prosek) | N Pdesignh (średni) | N Pdesignh (Átlag) | |||
| O | Elbu (Tj) (prosek) | O | elbu(Tj) (średni) | O | elbu(Tj) (Átlag) |
| P PDizajnh (grejač) | P Pdesignh (cieplejszy) | P Pdesignh (Melegebb) | |||
| Q | Elbu (Tj) (grejač) | Q | elbu(Tj) (cieplejszy) | Q | elbu(Tj) (Melegebb) |
| R | PDizajnh (hladnjak) | R | Pdesignh (chłodniejszy) | R | Pdesignh (Hidegebb) |
| S | Elbu (Tj) (hladnjak) | S | elbu(Tj) (chłodniejszy) | S | elbu(Tj) (Hidegebb) |
| T | Deklarisan kapacitet u referentnim dizajn uslovima | T | Wydajność deklarowana w projektowych warunkach odniesienia | T | Névleges teljesítmény tervezési referencia-környezetben |
| U | Pretpostavljeni rezervni kapacitet grejanja | U | Zakładana rezerwowa wydajność grzewcza | U | Becsült rasegítő fütőteljesítmény |
Warmer Season
[SRPSKI]: Sezona grejanja
Warmer and Colder Season
Warmer and Colder Season
natural_image