Silence Force Compact RO4441 - Vacuum Cleaner ROWENTA - Free user manual and instructions
Find the device manual for free Silence Force Compact RO4441 ROWENTA in PDF.
User questions about Silence Force Compact RO4441 ROWENTA
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
Download the instructions for your Vacuum Cleaner in PDF format for free! Find your manual Silence Force Compact RO4441 - ROWENTA and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. Silence Force Compact RO4441 by ROWENTA.
USER MANUAL Silence Force Compact RO4441 ROWENTA
text_image
Diagram of a hairdryer with labeled parts and directional arrows indicating process flow
natural_image
Line drawing of a medical or laboratory tool with a handle and connector (no text or symbols)
text_image
CLICK
natural_image
Illustration of hands holding a tool with directional arrows indicating movement (no text or symbols)fig. 1 fig. 2 fig. 3 fig. 4

natural_image
Illustration of hands using a tool to adjust or install a mechanical component (no text or symbols visible)
text_image
Diagram illustrating a medical procedure with labeled arrows and circular indicators, likely related to surgical or diagnostic procedures.
flowchart
graph TD
A["Step 1: Box 1"] --> B["Step 2: Box 2"]
B --> C["Step 3: Box 3"]
C --> D["Step 4: Box 4"]

text_image
Diagram illustrating a medical procedure with labeled arrows and components, likely for surgery or diagnostic steps.fig. 5 fig. 6 fig. 7 fig. 8

natural_image
Diagram of a biological structure with arrows indicating internal components (no text or labels)
natural_image
Line drawing of a hairdryer with a handle and spool, no text or symbols present
text_image
1 PUSH 2
natural_image
Illustration of two mechanical clamping devices with no visible text or symbolsfig. 9 fig. 10 fig. 11

natural_image
Line drawing of a person using a vacuum cleaner on a device (no text or symbols)
natural_image
Line drawing of a person's lower body with a bag and medical device (no text or symbols)
natural_image
Line drawing of a hand holding a device with an arrow indicating rotation (no text or symbols)fig. 12

natural_image
Illustration of a hand holding a device with an upward arrow indicator (no text or symbols present)fig. 13 fig. 14 fig. 15 fig. 16

natural_image
Diagram of a car interior showing hand positioning and directional arrow (no text or symbols)
natural_image
Illustration of a hand placing a textured object into a trash bin with an arrow indicating motion (no text or symbols)
natural_image
Illustration of a hand holding a device with an arrow pointing to it (no text or symbols present)
natural_image
Diagram of a hand holding a mechanical component with an arrow indicating direction (no text or symbols present)fig. 17 fig. 18 fig. 19 fig. 20

natural_image
Line drawing of a car interior with a hand inserting a component into the engine compartment (no text or symbols)
natural_image
Illustration of a hand placing a grid-like object into a trash bin with a checkmark (no text or symbols)
text_image
CLICK 2 1fig. 21 fig. 22 fig. 23
9 Cassette filtre HEPA* Ref. ZR002901
For your safety, this appliance conforms to the applicable standards and regulations (Low Voltage, Electromagnetic Compatibility, Environmental, etc. Directives) in force at the time of manufacture
1 • Conditions of use
Your vacuum cleaner is an electrical appliance: it must only be used under normal operating conditions. The appliance should be used and stored out of the reach of children and certain disabled persons. Never leave the appliance unattended when it is switched on. Always keep nozzles and tube ends well away from eyes and ears. Do not vacuum surfaces dampened with alcohol, lany water or any kind of liquids, hot substances, ultra-fine substances (plaster, cement, ash, etc.) large sharp debris (glass), dangerous products (solvents, stripping compounds, etc.), chemical products (acids, cleaners, etc.), inflammable or explosive products (petrol- or alcoholbased).
Do not immerse the appliance in water, splash water on the appliance or store it outdoors. Do not use the appliance if it has been dropped and shows signs of damage or functions abnormally. In this case, do not
DESCRIPTION
1 Cover
2 Bag full indicator
3 Carrying handle
4 Cover opening
5 Automatic cable rewind pedal
6 Bag compartment
7 Bag holder
8 Suction opening
9 HEPA filter cartridge* ref. ZR 002901
10 On/Off pedal
11 HEPA*filter cassette compartment
12 SILENCE SYSTEM
13 Power control
14 Upright parking
15 Wonderbag*
open the appliance, but rather send it to the nearest Authorised Service Centre or contact Rowenta's Customer Service (see contact details on last page).
2 • Electrical power supply
Make sure that the operating voltage of your vacuum cleaner is the same as your supply voltage - 230-240v alternating current. Unplug the appliance by removing the plug from the power outlet:
- immediately after use,
- before changing accessories,
- before maintenance, cleaning or changing the dustbag.
Do not use the appliance:
- if the supply cord is defective. The rewinder and cord assembly of your vacuum cleaner must be replaced by an Approved Service Centre because special tools are required for carrying out any repair in order to prevent any danger.
3 • Repairs
Repairs should only be carried out by specialists using original replacement parts. It is dangerous to try to repair an appliance yourself.
Accessories
16 Flexible tube with power nozzle and mechanical power control*
17 Flexible tube with High Control power nozzle and 3-position power control slider*
18 Telescopic crevice tool*
19 Furniture brush*
20 Accessory clip*
21 Upholstery nozzle*
22 Crevice tool*
23 Telescopic tube*
24 Folding telescopic tube - Compact System*
25 Delta Silence Force*
26 Floor nozzle*
27 Turbobrush*
28 Mini turbobrush*
29 Floor nozzle*
Thanks to the Silence System (an exclusive Rowenta system) your vacuum cleaner makes much less noise when vacuuming.
1 • Remove packaging
Unpack your appliance and remove any labels. Keep your warranty card and carefully read the operating instructions before using your appliance for the first time.
2 • Hints and precautions
Before each use the supply cord should be completely unwound. Do not allow it to become trapped or be pulled over sharp edges. If you use an extension cord, make sure that it is in perfect condition and appropriate to the power rating of your appliance. Never unplug the appliance by pulling on the cord.
Never operate the vacuum cleaner without a bag and without a filtration system (cassette). Your appliance is equipped to that end with a safety system to ensure the filter cassette is present.
1 • Assembling the elements of the appliance
Push the hose into the vacuum opening (fig.1) and turn to lock. To remove it, turn in the opposite direction and pull. Attach the accessory clip to the tube and place the accessories on it. The accessory support sits on the tube; the accessories can be taken off the support, which remains attached to the tube (fig.2).
Assemble the telescopic tube*. Adjust the desired length on the tube (fig. 4). If your appliance is equipped with the Compact System with folding tubes: (fig. 3).
To use, unfold the 2 tubes until you hear a • «click». Set to the desired length.
Fit the desired accessory onto the end of the tube (fig. 5):
For rugs and wall-to-wall carpeting: use • the nozzle with brushes lifted.
IMPORTANT If the vacuum suction unit is hard to move, reduce the vacuum power on your appliance using the electronic power control on the vacuum cleaner.
For parquets and smooth flooring: use the • nozzle with the brush extended or use the parquet nozzle*.
Do not move the vacuum cleaner by pulling its cord, the appliance must be moved by its carrying handle. Never lift the appliance by its cord use the carrying handle. Stop and unplug the appliance after each use. Always turn off and unplug your appliance before maintenance or cleaning. Only use Rowenta bags and filters. Use only Rowenta or Wonderbag bags and filters.
Check that all the filters are properly in place. In the case of difficulty in obtaining accessories and filters for this vacuum cleaner, contact the Rowenta customer service department (see last page for contact details).
This appliance is not intended for use by people (including children) whose physical, sensory or mental capacities are impaired, or by people with no experience or familiarity with such devices, unless they are supervised by a person who is responsible for their security or have received instructions as to how to use the appliance.
Children must be supervised to ensure that they do not play with the appliance.
For corners and other areas that are difficult to reach: use the crevice tool*.
For furniture: use the brush* or the furniture • crevice tool*.
IMPORTANT Never operate the vacuum cleaner without a bag and without a filtration system (cassette).
IMPORTANT Always stop and unplug your vacuum cleaner before changing accessories.
2 • Plugging in the electrical power cord and using the vacuum cleaner
Fully unroll the cord, plug in your vacuum cleaner and press the On/Off pedal, (fig.6). Set the power using the vacuum cleaner's power control, if your model is equipped with a High Control wand (fig.7) you can also adjust the vacuum power using the 3 position slider*:
- Position

for fabrics
and furniture (fig.7).
- Position

for parquets and smooth (fig.7).
flooring (fig.7).
- Position

for rugs and wall-to-wall g (fig.7).
UTILISATION
3 • Storing and transporting the appliance
After use, stop your appliance by pressing on the on/off pedal and unplug it (fig.8). Stow the cable by pressing the automatic cable rewind pedal (fig.9). In the upright position, place the suction unit in the parking position (fig.10). You can then carry and store your vacuum cleaner in the park position (fig.13). If your appliance is
CARE AND CLEANING
IMPORTANT Always turn off and unplug your appliance before maintenance or cleaning.
1 • Changing the bag
The bag full indicator shows you when the bag is full or saturated. If you notice that your vacuum cleaner is less efficient, select the maximum power and hold the nozzle off the floor. If the indicator remains red, replace the bag. Open the cover on your vacuum cleaner (fig.15). Remove the wonderbag (fig.16-17) and dispose of it in a rubbish bin (fig.18).
IMPORTANT Do not reuse the wonderbag, it is a single use bag
Place a new wonderbag in the bag holder, using the ring (fig.19). Position the bag and open it out inside the compartment (fig.20). Make sure that the bag is in the correct position before closing the cover.
IMPORTANT Never operate the vacuum cleaner without a bag.
GB
equipped with the Compact System with folding tubes:
- Retract the telescopic tubes (fig.11) and press the «Push» button to open the tube and fold it. If your appliance is equipped with • CLIP'N'STORE, attach your hose to the accessory clip for easier storage (fig.12).
2 • Change the HEPA\* filter cassette (ref. ZR 0029 01)
IMPORTANT Replace the filtration system once a year.
The HEPA filter cassette ref. ZR 0029 01 is available from your dealer or Approved Service Centres.
Open the lid of your vacuum cleaner (fig.15). Remove the wonderbag (fig.16) and then remove the HEPA* filter cartridge (fig.21) and dispose of the cartridge in a dustbin (fig.22). Fit the new Hepa* filter cassette (ref. ZR 0029 01) in its compartment (fig.23).
Put the wonderbag back in place. Check that the Hepa* filter cassette is fitted correctly before re-closing the cover.
IMPORTANT Never operate the vacuum cleaner without a Hepa filter cartridge. Your appliance is equipped with a Hepa filter cartridge presence safety system for this (the cover will not close if a Hepa filter cartridge has not been installed).
3 • Cleaning your vacuum
Clean the accessories of your appliance with a soft damp cloth, then dry them. Do not use abrasive or aggressive products.
IMPORTANT As soon as your vacuum cleaner starts to malfunction, and before performing any checks stop the appliance by pressing the Start/Stop switch.
If your vacuum cleaner does not start The appliance is not plugged-in, check • that the appliance is correctly plugged in.
If there is no suction
An accessory or the tube is clogged.
Unclog the accessory tube or flexible hose.
The cover was not closed properly: check • that the bag is properly installed and reclose the cover.
If the suction of your vacuum cleaner has dropped, it makes a noise and whistles
An accessory or the flexible hose is • partially clogged. Unclog the accessory tube or flexible hose.
The bag is full or clogged with fine dust.
Fit a new bag or empty the fabric dust bag.
The filter is full: change the HEPA* filter •
cassette (ref. ZR 0029 01) and fit it back into position (see page 16 paragraph 2).
If the manual suction regulator on the • grip is open, close the manual suction regulator*.
If the bag full indicator remains red The bag is full. Fit a new one.•
If the floor nozzle is hard to move around Set vacuum power with the 3-position • power control*
If the power cable does not rewind completely
The power cord is slow in re-entering its • housing. Pull the cord out to its entire length and press on the automatic cord rewind pedal.
If problems persist, take your vacuum cleaner to the nearest Rowenta approved Service Centre (see list of approved service centres) or contact the Rowenta Customer Service (see contact details on last page).
WARRANTY
This product has been designed for • domestic use only. Any professional use, innappropriate use or failure to comply with the instructions, the manufacturer accepts no responsibility and the guarantee will not apply.
- Read the instructions for use carefully before using your appliance for the first time: any use which does not conform to these instructions will absolve Rowenta from any liability.
| ACCESSORIES* VACUUMING | FITTING AN ACCESSORY | PURCHASE LOCATIONS | |
Wonderbag bag![]() | Universal bag. | Fit the ring onto the Wonderbag then place it inside the compartment. | Rowenta Approved Service Centres (see the attached address list). |
Furniture brush*![]() | To clean furniture. | Fit the furniture brush onto the end of the power nozzle or tube. | |
Upholstery nozzle![]() | To clean furniture. | Fit the furniture crevice tool onto the end of the power nozzle or the tube. | |
Telescopic crevice tool![]() | To get into corners and places that are hard to reach. | Fit the telescopic crevice tool onto the end of the power nozzle or the tube. | |
Floor nozzle![]() | For fragile floors. | Fit the hardfloor tool to the end of the tube. | |
Mini turbobrush![]() | To clean upholstery fabrics in depth. | Fit the mini turbobrush to the end of the tube. | |
Turbobrush![]() | To remove threads and animal hairs ingrained into mats and carpets. | Fit the turbobrush to the end of the tube. | |
ENVIRONMENT
In accordance with current regulations, before disposing of an appliance no longer needed, the appliance must be rendered inoperative (by unplugging it and cutting off the supply cord). Environment: Directive 2002/95/EC.

Environment protection first!
① Your appliance contains valuable materials which can be recovered or recycled.
Leave it at a local civic waste collection point.