Download the instructions for your Air Conditioning in PDF format for free! Find your manual LP0825WSB - LG and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. LP0825WSB by LG.
USER MANUAL LP0825WSB LG
Read this owner's manual thoroughly before operating the appliance and keep it handy for reference at all times.
TYPE: PORTABLE AIR CONDITIONER
LP0825WSB
LP1025WSSM
EN ENGLISH
FR FRANÇAIS





A2L
TABLE OF CONTENTS
2 TABLE OF CONTENTS
3 SAFETY INSTRUCTIONS
8 PRODUCT OVERVIEW
8 Key Parts and Components
9 INSTALLATION
9 Electrical Information
10 Before Installing the Air Conditioner
10 Wireless Remote Control
11 Preparing for Installation
12 Selection of Installation Location
12 Attaching the Flexible Vent Hose Set
13 Window Vent Panel and Extensions(LP1025WSSM)
14 Window Vent Panel and Extensions(LP0825WSB)
15 Installing Vent Panels
17 Garden Hose Installation for Dehumidifying (Dry Mode Only)
18 OPERATION
18 Control Panel and Remote Control
21 SMART FUNCTIONS
21 LG ThinQ Application
23 MAINTENANCE
23 Emptying the Water Collection Tank
23 Cleaning the Case
23 Cleaning the Air Filter
24 TROUBLESHOOTING
24 Before Calling for Service
27 WARRANTY
SAFETY INSTRUCTIONS
READ ALL INSTRUCTIONS BEFORE USE
Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and follow all safety messages.

This is the safety alert symbol.
This symbol alerts you to potential hazards that can kill or injure you and others.
All safety messages will follow the safety alert symbol and either the word WARNING or CAUTION.
These words mean:

WARNING
You may be killed or seriously injured if you do not follow instructions.

CAUTION
You may be injured or cause damage to the product if you do not follow instructions.
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what may happen if the instructions are not followed.
The following symbols are displayed on units.

This symbol indicates that this appliance uses a flammable refrigerant.
If the refrigerant is is leaked and exposure to an external ignition source, there is a risk of fire.

This symbol indicates that the Operation Manual should be read carefully.

This symbol indicates that a service personnel should be handling this equipment with reference to the Installation Manual.

This symbol indicates that information is available such as the Operating Manual or Installation Manual.
IMPORTANT SAFETY INSTRUCTIONS

WARNING
To reduce the risk of explosion, fire, death, electric shock, scalding or injury to persons when using this product, follow basic precautions, including the following:
INSTALLATION
- Before use, the appliance must be properly installed as described in this manual.
- Contact the authorized service technician for repair or maintenance of this unit.
-
Contact the installer for installation of this unit.
-
When the power cord is to be replaced, replacement work shall be performed by authorized personnel only using only genuine replacement parts.
- Installation work must be performed in accordance with the National Electric Code by qualified and authorized personnel only.
- Connect to a properly rated, protected, and sized power circuit to avoid electrical overload.
• Always plug into a grounded outlet. - Do not under any circumstances, cut or remove the third (ground) prong from the power cord.
- When installing or moving the appliance, be careful not to pinch, crush, or damage the power cord.
- Plug in the power plug properly.
- Do not modify or extend the power cord.
- Do not start/stop operation by plugging/unplugging the power cord.
- If the cord/plug is damaged, have it replaced by an authorized service person using authorized replacement parts.
- Use a dedicated circuit.
- Do not disassemble or modify the product.
- Adhere to all industry recommended safety procedures including the use of long-sleeved gloves and safety glasses.
- Use care when unpacking and installing. The edges of the product may be sharp.
- Disconnect the power cord or circuit breaker before installing or servicing the appliance.
- Keep packaging materials out of the reach of children. These materials can pose a suffocation risk to children.
- Store and install the product where it will not be exposed to temperatures below freezing or exposed to outdoor weather conditions.
- Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
- Do not install the unit in potentially explosive atmospheres.
OPERATION
- Use this appliance only for its intended purpose.
- Never attempt to operate this appliance if it is damaged, malfunctioning, partially disassembled, or has missing or broken parts, including a damaged cord or plug.
- Repair or immediately replace all power cords that have become frayed or otherwise damaged. Do not use a cord that shows cracks or abrasion damage along its length or at either end.
- Do not run cord under carpets or mats where it could be stepped on and damaged.
- Keep the cord out from under heavy objects like tables or chairs.
- Do not place the power cord near a heat source.
- Do not use an adaptor or plug the product into a shared outlet.
- Do not tamper with controls.
- If you detect a strange sound, a chemical or burning smell, or smoke coming from the appliance, unplug it immediately, and contact an LG Electronics Customer Information Center.
- Never unplug the appliance by pulling on the power cord. Always grip the plug firmly and pull straight out from the outlet.
- Do not grasp the power cord or touch the appliance controls with wet hands.
- The air conditioner is not intended for use by young children or invalids without supervision.
-
Young children should be supervised to ensure that they do not play with the air conditioner.
-
If water enters the product, turn off the power at the main circuit, then unplug the product and call for service.
- If the product has been submerged, contact the LG Electronics Customer Information Center for instructions before resuming use.
- Unplug the product if it will not be used for long periods.
- Unplug the product before cleaning.
- In the event of a gas leak (propane gas, etc.) do not operate this or any other appliance. Open a window or door to ventilate the area immediately.
- This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety.
- To clean the interior, contact the LG Electronics Customer Information Center or dealer. Using harsh detergents may cause corrosion or damage to the unit.
- Do not use solvent-based detergent on the product. Doing so can cause corrosion or damage, product failure, electrical shock, or fire.
- If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
GROUNDING INSTRUCTIONS
- The power cord of this appliance is equipped with a three-prong (grounding) plug. Use this with a standard three-slot (grounding) wall power outlet to minimize the hazard of electric shock. The customer should have the wall receptacle and circuit checked by a qualified electrician to make sure the receptacle is properly grounded. DO NOT CUT OR REMOVE THE THIRD (GROUND) PRONG FROM THE POWER PLUG.
- Situations when the appliance will be disconnected occasionally; Because of potential safety hazards, we strongly discourage the use of an adapter plug. However, if you wish to use an adapter, a TEMPORARY CONNECTION may be made. Use UL-listed adapter, available from most local hardware stores. The large slot in the adapter must be aligned with the large slot in the receptacle to assure a proper polarity connection.
- Attaching the adapter ground terminal to the wall receptacle cover screw does not ground the appliance unless the cover screw is metal, and not insulated, and the wall receptacle is grounded through the house wiring. The customer should have the circuit checked by a qualified electrician to make sure the receptacle is properly grounded.
- Disconnect the power cord from the adapter, using one hand on each. Otherwise, the adapter ground terminal might break. Do not use the appliance with a broken adapter plug.
- Situations when the appliance will be disconnected often; Do not use an adapter plug in these situations. Unplugging the power cord frequently can lead to an eventual breakage of the ground terminal. The wall power outlet should be replaced by a three-slot (grounding) outlet instead.

CAUTION
To reduce the risk of minor or moderate injury to persons, malfunction, or damage to the product or property when using this product, follow basic precautions, including the following:
INSTALLATION
- Take care when installing the product that exhaust or condensation does not damage nearby property.
- Follow installation instructions exactly to avoid excessive vibration or water leakage.
- Do not install the unit in potentially explosive atmospheres.
OPERATION
- This appliance is not intended for use as a precision refrigeration system. Do not use it for special purposes such as maintaining pets, food, precision machinery, or art objects.
- When installing or moving the appliance, be careful not to pinch, crush, or damage the power cord.
- Make sure the air inlet and outlet are free from obstructions.
- Use a soft cloth to clean the appliance. Do not use waxes, thinners, or harsh detergents.
- Do not step on or place heavy objects on top of the appliance.
- Do not operate the appliance without the filter securely installed.
- Do not drink water drained from the appliance.
- Be sure to ventilate sufficiently when the air conditioner and a heating appliance such as a heater are used simultaneously.
- Being exposed to direct airflow for an extended period of time could be hazardous to your health.
- Remove the batteries if the remote control is not to be used for an extended period of time.
- Never mix different types of batteries, or old and new batteries for the remote control.
- Stop using the remote control if there is a fluid leak in the battery. If your clothes or skin are exposed to the leaking battery fluid, wash off with clean water.
- If the leaking battery fluid has been swallowed, rinse the inside of the mouth thoroughly and consult a doctor.
- Do not recharge or disassemble the batteries.
MAINTENANCE
- Clean the filter every two weeks.
- Never touch the metal parts of the air conditioner when removing the air filter.
- Never spray the product with water or use strong cleaning agents or solvents when cleaning the air conditioner. Use a soft cloth to avoid scratching the exterior.
- To clean the interior, contact the LG Electronics Customer Information Center or a dealer. Using harsh detergents may cause corrosion or damage to the unit.
REFRIGERANT (FOR R32 ONLY)

WARNING
- Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacturer.
- The appliance shall be stored in a room without continuously operating ignition sources (for example: open flames, an operating gas appliance or an operating electric heater).
- Do not pierce or burn. Be aware that flammable refrigerants may not contain an odor.
- The appliance shall be stored in a well-ventilated area where the room size corresponds to the room area as specified for operation.
- The appliance shall be stored so as to prevent mechanical damage from occurring.
- Any person who is involved with working on or breaking into a refrigerant circuit should hold a current valid certificate from an industry-accredited assessment authority, which authorises their competence to handle refrigerants safely in accordance with an industry recognised assessment specification.
- Servicing shall only be performed as recommended by the equipment manufacturer.
- Maintenance and repair requiring the assistance of other skilled personnel shall be carried out under the supervision of the person competent in the use of flammable refrigerants.
- Keep any required ventilation openings clear of obstruction.

CAUTION
- This unit contains flammable refrigerant and has special safety precautions not normally associated with older units. Please follow all precautions and advisories.
- Use caution while handling and prevent damage to unit. Do not put any holes into product for any reason. This can cause damage to product and prevent unit from cooling.
- Maintenance and cleaning of unit should be performed by trained personnel. Failure to properly clean unit can result in damage to the refrigeration system and or the electrical system.
- Make certain that all the air circulation/ventilation openings are free from obstruction.
- Service should only be performed by technicians properly trained and certified in the use of flammable refrigerants. Any service performed by unauthorized servicers/individuals will void all warranties.
- When storing the appliance, do not put in a room with any open flame appliances, such as gas water heaters or furnaces. Also keep away from electric heaters. Damaged units should be repaired before Storage.
- The maximum refrigerant charge amount. (Refer to nameplate marking refrigerant amount.)
- The appliance shall be suitable stored to prevent mechanical damage from occurring.
- Information for handling, installation, cleaning, servicing and disposal of refrigerant.
- A notice that servicing shall be performed only as recommended by the manufacturer.
- A warning that the appliance shall be stored in a room without continuously operating open flames (for example an operating gas appliance) and ignition sources (for example an operating electric heater).
- The manufacturer should specify other potential continuously operating sources known to cause ignition of the refrigerant used. The appliance shall be stored so as to prevent mechanical damage from occurring.
- Any person who is involved with working on or breaking into a refrigerant circuit should hold a current valid certificate from an industry-accredited assessment authority, which authorizes their competence to handle refrigerants safely in accordance with an industry recognized assessment specification.
- Servicing shall only be performed as recommended by the equipment manufacturer. Maintenance and repair requiring the assistance of other skilled personnel shall be carried out under the supervision of the person competent in the use of flammable refrigerants.
SAVE THESE INSTRUCTIONS
PRODUCT OVERVIEW
Key Parts and Components
① AIR DISCHARGE
The adjustable louvered air discharge opens automatically when the air conditioner is turned on, and closes when it is turned off. It can also be set to oscillate to distribute air more evenly through the room.
② CONTROL PANEL AND DISPLAY
Easy-to-read digital display shows the set temperature, and indicator lights show the operating mode. Simple push buttonsmake changing settings quick and easy.
③ SWIVELING CASTERS
Swiveling casters allow you to move the air conditioner easily on most floor surfaces.
④ INTEGRATED HANDLES
Integrated handles provide a convenient grip when lifting the air conditioner.
⑤ WIRELESS REMOTE CONTROL
The remote control allows you to adjust the temperature and operate most functions of the air conditioner from across the room.
6 BOTTOM DRAIN PORT
Before moving the air conditioner, drain the internal water in the collection tank completely using the bottom drain port.
⑦ CONTINUOUS DRAIN PORT
Connect a garden hose for continuous drainage when running the air conditioner in Dry mode.
8 HOSE AND DIFFUSER
Use the diffuser and hose to connect the air conditioner to the window installation kit to vent exhaust air outside.
⑨ AIR FILTER

text_image
Diagram of a portable air conditioner unit with numbered parts labeled 1, 2, 3, and 4
text_image
Diagram showing two devices: a remote control with labeled parts and a cylindrical device with labeled parts.
text_image
Diagram of a solar panel installation with labeled components including heater, fan, and batteryINSTALLATION
Electrical Information
Power cord may include a current interrupter device. TEST and RESET buttons are provided on the plug case. The device should be tested on a periodic basis by first pressing the TEST button and then the RESET button. If the TEST button does not trip or if the RESET button will not stay engaged, discontinue use of the air conditioner and contact a qualified service technician.
for 120 V\~

natural_image
Technical line drawing of a two-part electrical device with labeled buttons (RESET and TEST), no text or symbols present.| Use Wall Receptacle Power Supply | |
Standard 120 V~, 3-wire grounding receptacle rated 15A / 120 V~ / 60 Hz | Use 15 A,timedelay fuse or15 A circuit breaker. |

WARNING
- This appliance should be installed in accordance with the National Electrical Code.
- Use of extension cords could cause serious injury or death.
- Do not use an extension cord with this portable air conditioner.
- Do not use surge protectors or multi-outlet adapters with this portable air conditioner.
- Never push the TEST button during operation. Doing so can damage the plug.
- Do not remove, modify, or immerse this plug. If this device trips, the cause should be corrected before further use.

CAUTION
- The conductors inside this cord are surrounded by shields, which monitor leakage current. These shields are not grounded. Periodically examine the cord for any damage. Do not use this product in the event the shields become exposed. Avoid shock hazard. This unit cannot be user-serviced. Do not open the tamperresistant sealed portion. All warranties and performance will be voided. This unit is not intended to be used as an ON/OFF switch.
Before Installing the Air Conditioner
PREPARING FOR OPERATION
Refer to the Installaiton instructions included in this manual before using the air conditioner. Once the air conditioner has been properly assembled and installed
① Plug the power cord into its own dedicated properly grounded outlet. Do not plug other appliances into the same outlet. Doing so could overload the outlet and create a fire hazard.
② Make sure the air conditioner and cord are positioned where they do not create a tripping hazard and will receive adequate Ventilation. Do not place the appliance near furniture or objects that could block the vben openings.
③ Make sure that any items that could be blown over or damaged by the airflow from the fan are out of the airflow path.
IMPORTANT:
- Do not remain in the direct airflow from the air conditioner for extended periods of time.
- When used at the same time as stoves, fireplaces, and other combustion devices, make sure there is a sufficient flow of fresh air into the room. Do not use in tightly enclosed spaces With these types of devices.
- This air conditioner is intended for household use as a consumer comfort appliance. Do not use it as a precision climate control system, or for purposes such as cooling precision equipment, food, pets, plants, artwork, etc. Such items could be damaged.
- Do not bend the hose downward when Window installation kit is not applied. It may cause failure of air conditioner or performance deterioration.
UNPACKING THE AIR CONDITIONER
- Remove and store packing materials for reuse. Remove any shipping tape before using the air conditioner. If the tape leaves behind any adhesive, rub a small amount of liquid dish soap onto it and Wipe With a damp cloth. Do NOT use sharp instruments, alcohol, thinners, or abrasive cleaners to remove adhesive. They could damage the finish.
Wireless Remote Control
Inserting Batteries
If the display screen of the remote control begins to fade, replace the batteries. Insert AAA (1.5 V) batteries before using the remote control.
1 Remove the cover on the back of the remote control.

text_image
Be sure to note proper polarity!2 Insert the new batteries and make sure that the + and - terminals of the batteries are installed correctly.
NOTE
- New batteries are supplied with the air conditioner for use in the remote control.
- Do not use a rechargeable battery. Make sure that the battery is new.
- In order to prevent discharge, remove the battery from the remote control if the air conditioner is not going to be used for an extended period of time.
- Keep the remote control away from extremely hot or humid places.
- To maintain optimal operation of the remote control, the remote sensor should not be exposed to direct sunlight.
- The remote control will not work properly if the unit is exposed to direct light or there is any obstacle between the unit and the remote controller.
Preparing for Installation
Basic Installation Materials Supplied

text_image
Mounting Bracket Flexible Vent Hose DiffuseLP0825WSB

natural_image
Simple line drawing of a rectangular object with a circular cutout on the side (no text or symbols)1 Panel A (25") Window vent panel

2 Long adhesive foam seals

1 Panel B (25") Extension panel

1 Non-adhesive foam seal

4 Screws

2 Short adhesive 4 Rivets foam seals

2 Security bracket

LP1025WSSM

natural_image
Simple line drawing of a rectangular plate with a circular cutout and a curved edge (no text or symbols)1 Panel H (18") Window vent pane

2 Long adhesive foam seals

1 Panel I (9 11/16") Extension panel

1 Non-adhesive foam seal

natural_image
Simple line drawing of a rectangular object with a textured top and base (no text or symbols)1 Panel J (18") Extension panel

2 Short adhesive foam seals

natural_image
Simple line drawing of a rectangular object with a horizontal edge and tick marks (no text or symbols)1 Panel K (18") Extension panel



4 Screws 2 Security bracket 4 Rivets
Installation Tools




Phillips screwdriver Cutting knife Tape measure
"No residue" duct tape
Selection of Installation Location
① Place the unit on a level floor.
② For best performance, allow at least 20" of air Space on all Sides of the unit for good air circulation.
③ Place the unit near a window. The hose and diffuser will be used to connect the air conditioner to the window installation kit to vent exhaust air outside.

text_image
20" 20" SerNOTE
The length of the flexible vent hose is specially designed according to the specification of this product. Do not replace or extend it with a hose that is not specifically designed for use with this product as this could cause malfunction.
Attaching the Flexible Vent Hose Set
- Preparing the exhaust hose assembly:
- Insert the mounting bracket into the slot on the back of the air conditioner.
- Slide down to lock the hose into place.
- Confirm the hose is locked in place before operating.
Press the mounting bracket and the diffuser into the flexible exhaust hose. Both mounting bracket and diffuser have integral clips that snap onto the hose.

text_image
Mounting Bracket Flexible Vent Hose DiffuserExhaust hose assembly

text_image
LOCK UNLOCKWindow Vent Panel and Extensions(LP1025WSSM)
The window installation kit allows you to install the air conditioner in most vertical-sliding windows 18" to 50" wide, or horizontal-sliding windows from 18" to 50" high.
| Window Length\Panel Length | H18" 9 | I ^11/_16 " | J18" 18" | K | Fig. |
| 18" | |||||
| 19" - 26" | |||||
| 27" - 34" | |||||
| 35" - 50" |
- Please check your window size and choose the fit from the above table.
- If your window size requires more than 2 panels, after adjusting the length, please secure the panels with rivets, E.

text_image
Rivet E
text_image
18" Panel H 18" 18" Panel HFor an 18" window opening, use the window vent panel (Panel H) by itself.
Fig. "a"

text_image
Panel J 27" - 34" Panel H 27" - 34" Panel J 0 Panel HFor window openings from 27" to 34", use the window vent panel (Panel H) and extension Panel J.
Fig. "c"

text_image
Panel I (9¹¹/₁₆") Panel H (18") Panel K (18") Panel J (18")
text_image
Panel I 19" - 26" Panel H 19" - 26" Panel I Panel HFor window openings from 19" to 26", use the window vent panel (Panel H) and extension Panel I.
Fig. "b"

text_image
Panel K 35" - 50" Panel J Panel H Panel H 35" - 50" Panel J Panel KFor window openings from 35" to 50", use the window vent panel (Panel H) and extension Panel J and Panel K.
Fig. "d"
Window Vent Panel and Extensions(LP0825WSB)
The window installation kit allows you to install the air conditioner in most vertical-sliding windows 25" to 47" wide, or horizontal-sliding windows from 25" to 47" high.
| Window opening\Panel | A25" | B25" | Fig. |
| 25" | √ | a | |
| 26" - 47" | √ | √ | b |
- Select the panels required based on the window opening, as shown above.
- For longer window openings, assemble and adjust the panels to fit the window opening. Use screws (included) to fix the panels together at the proper length.

text_image
C B A
text_image
Panel A 25" 25" Panel AFor an 25" window opening, use the window vent panel (Panel A) by itself.
Fig. a

natural_image
Simple line drawing of a rectangular object with a curved cutout and a diagonal line, no text or symbols present.Panel A (25")

natural_image
Simple line drawing of a rectangular object with a diagonal line extending from its top (no text or symbols)Panel B (25")
1 Window Vent Panel
1 Extension Panel
Window Installation Kit
(Includes 1 window vent panel and 1 Extension Panel)

text_image
Panel A 26" - 47" Panel B 26" - 47" Panel AFor window openings from 26" to 47", use the window vent panel (Panel A) and extension Panel B.
Fig. b
Installing Vent Panels

text_image
Long adhesive foam seal Short adhesive foam seal Long adhesive foam seal Short adhesive foam seal1 Attach the long adhesive foam weather seals to the top and bottom sides of the window vent panel assembly. Attach the short foam weather seals to the right and left sides of the panel assembly. (Attaching the foam weather seals to the panel assembly rather than the window sash and frame makes for easier cleanup when removing the panel assembly.)

text_image
Extension panel (if required) Vent panel2 Insert the panel assembly in the bottom sash channel. Use care when installing the assembly, which will now fit very tightly in the opening. Close the sash tightly against the top of the panel assembly.

text_image
Security Bracket Screw3 If needed, install the included security bracket with screws.

text_image
Non-adhesive foam seal4 Measure and cut the included non-adhesive foam to fit the window opening. Stuff it between the window sashes to prevent air and insects from getting into the room.

text_image
Slot Insert5 Align the tabs on the diffuser with slots in the outer slide section. Insert the diffuser into the opening in the vent panel.

text_image
Screw6 Insert the screw in the hole in the diffuser to prevent the diffuser from sliding out of the vent opening.
NOTE
- For a tighter seal, use "no residue" duct tape (not provided) to seal any gaps around the installed panel assembly, around the diffuser, and between the sashes.
- For best results, keep the vent hose as short and straight as possible. However, shape the diffuser end of the vent hose into an inverted U shape just inside the window to allow any rain or condensation to drain out the window.

natural_image
Line drawing of a portable air conditioner with a coiled hose (no text or symbols)
natural_image
Line drawing of a portable air conditioner with a coiled hose extending into it (no text or symbols)Best positioning Inverted U shape
Garden Hose Installation for Dehumidifying (Dry Mode Only)
- Remove the drain plug when using the Dry (dehumidifying) mode.
- Install a 5/8" (16 mm) inside diameter garden hose (not provided) into the continuous drain port and place the open end of the hose over a floor drain or bucket.

natural_image
Technical line drawing of a server rack unit with ventilation grilles and cooling fans (no text or symbols)
natural_image
Line drawing of a portable air conditioner unit with cooling fans and a potted cup (no text or symbols)NOTE
• Install the garden hose when you need dehumidification in high humidity.
- This product has a self-evaporative system. The condensing water will be recycled to cool the condenser. This not only improves cooling efficiency, but also saves energy for you.
OPERATION
Control Panel and Remote Contro

flowchart
graph TD
A["8 Clean Filter Net, filter"] --> B["1 2 6 7"]
C["Mode Filter / Next / Next / 12 U"] --> D["1 2 6 7"]
E["345 °F/°C - Hr/h"] --> F["Auto Swing / Incl. auto (3s)"]
G["345 °F/°C - Hr/h"] --> H["High Elevé Low Faible Auto Swing Incl. auto"]
I["345 °F/°C - Hr/h"] --> J["Fan Speed Vit. Vent"]
K["345 °F/°C - Hr/h"] --> L["Timer Minuteur Light / Lumine (3s)"]
M["345 °F/°C - Hr/h"] --> N["ThinQ"]
O["345 °F/°C - Hr/h"] --> P["Fan Speed Vit. Vent Wi-Fi (3s)"]
Q["345 °F/°C - Hr/h"] --> R["Timer Minuteur Light / Lumine (3s)"]

text_image
4 1 2 6 7 LG Mode Fan/Vit.vent. Swing Light Luminare Timer Minutour Ind, auto, 10-713d 3 51 Power (⏻)
Turns the air conditioner on and off.
A chime sounds to confirm you have turned it on or off.
2 Mode
Press this button repeatedly to toggle through and select the operating mode.
Modes include Cool, Dry (dehumidify), Fan.
An LED illuminates to indicate the selected mode. The default mode is Cool.
Cool
Compressor runs and cools the room. Use the ∧/∨ and Fan Speed buttons to set the desired temperature and fan speed.
Dry
Use the Dry mode to remove humidity from the room without additional cooling. The fan speed is preset and cannot be adjusted.
Fan
Fan circulates air but compressor does not run. Use the Fan Speed button to set the desired fan speed to either High, Low.
3 Temperature Control ∧/∨
In Cool, Dry mode, the / buttons adjust the set temperature up to 86 °F (30 °C) or down to 60 °F (16 °C), in one-degree increments.
NOTE
- To switch the temperature units on the display between Fahrenheit (°F) and Celsius (°C), press and hold the ∧ and ∨ buttons on the control panel at the same time for 5 seconds.
4 Fan Speed
Press repeatedly to toggle the fan speed between High and Low settings. An LED illuminates to indicate the selected fan speed. The fan speed can be changed in the Cool, Fan modes. The fan speed is preset in the Dry mode. After pressing the button, there is a brief delay before the fan motor changes speed.
5 Timer
Delay ON - When the air conditioner is off, set it to automatically turn on from 1 to 24 hours later, at its previous mode and fan settings.
Delay OFF - When the air conditioner is on, set it to automatically turn off from 1 to 24 hours later.
NOTE
- When the Timer is selected, use the / buttons to adjust time from 1 to 24 hours, in one-hour increments.
- To cancel the Timer function, press the Timer button on control panel.
6 Auto Swing
This function automatically moves the louvers to adjust the direction of the air flow. Press the Swing button on remote control repeatedly to select the desired direction.
NOTE
- Press and hold the V button on the control panel for 3 seconds to enter the Auto Swing.
7 Light
Sets the display screen brightness:

NOTE
- Press and hold the Timer button on the control panel for 3 seconds to adjust the brightness.
8 Clean Filter
The Clean Filter LED lights up to notify you that the filter needs to be cleaned.
After cleaning the filter, press and hold the Mode button on the control panel for 3 seconds to turn off the Clean Filter light.
NOTE
- The filter reset must be done using the control panel, not the remote control.
- This feature is a reminder to clean the air filter for more efficient operation. The LED light turns on after 250 hours of operation.
9 Wi-Fi
Enables connection of the air conditioner to the home Wi-Fi.
To connect Wi-Fi, press the Fan Speed button on the control panel for 3 seconds.
NOTE
- This functions may not be supported, depending on the model.
10 Removing Condensation Buildup
Condensation can build up inside the unit when the Cool and Dry modes are used.
The fan can be set to run for a short period after the product is turned off to help keep the inside of the appliance dry. This option is off by default.
Turning Condensation Fan On
1 Turn on the product, set it to Cool mode and let it run for at least 10 seconds.
2 Press and hold the Mode and Fan Speed buttons on control panel for 3 seconds until On appears in the display.
3 The condensation fan is now turned on. When the appliance is turned off, Co appears in the display and the fan will continue to run for 10 minutes. The appliance will then shut down as normal.
Turning Condensation Fan Off
1 When the product is powered on, press and hold the Mode and Fan Speed buttons on control panel for 3 seconds until OF appears in the display.
2 The condensation fan is now turned off. The appliance will shut down immediately when it is turned off.
NOTE
- Some functions cannot be used while this option is turned on.
SMART FUNCTIONS
LG ThinQ Application
This feature is only available on models with the ThinQ logo
The LG ThinQ application allows you to communicate with the appliance using a smartphone.
LG ThinQ Application Features
Communicate with the appliance from a smartphone using the convenient smart features.
Settings
Allows you to set various options on the appliance and in the application.
NOTE
- If you change your wireless router, internet service provider, or password, delete the registered appliance from the LG ThinQ application and register it again.
- The application is subject to change for appliance improvement purposes without notice to users.
• Functions may vary by model.
Before Using LG ThinQ Application
1 Check the distance between the appliance and the wireless router (Wi-Fi network).
- If the distance between the appliance and the wireless router is too far, the signal strength becomes weak. It may take a long time to register or installation may fail.
2 Turn off the Mobile data or Cellular Data on your smartphone.

text_image
Diagram showing hand pointing to two circular icons with directional arrows, indicating movement or direction change.3 Connect your smartphone to the wireless router.

text_image
Diagram showing a hand pointing at a Wi-Fi icon to process wireless signal transformationNOTE
- To verify the Wi-Fi connection, check that 📞 icon on the control panel is lit.
- The appliance supports 2.4 GHz Wi-Fi networks only. To check your network frequency, contact your Internet service provider or refer to your wireless router manual.
- LG ThinQ is not responsible for any network connection problems or any faults, malfunctions, or errors caused by network connection.
- If the appliance is having trouble connecting to the Wi-Fi network, it may be too far from the router. Purchase a Wi-Fi repeater (range extender) to improve the Wi-Fi signal strength.
- The Wi-Fi connection may not connect or may be interrupted because of the home network environment.
- The network connection may not work properly depending on the Internet service provider.
- The surrounding wireless environment can make the wireless network service run slowly.
- The appliance cannot be registered due to problems with the wireless signal transmission. Unplug the appliance and wait about a minute before trying again.
- If the firewall on your wireless router is enabled, disable the firewall or add an exception to it.
- The wireless network name (SSID) should be a combination of English letters and numbers. (Do not use special characters.)
- Smartphone user interface (UI) may vary depending on the mobile operating system (OS) and the manufacturer.
- If the security protocol of the router is set to WEP, you may fail to set up the network. Please change it to other security protocols (WPA2 is recommended) and register the product again.
Installing the LG ThinQ Application
Search for the LG ThinQ application from the Google Play Store or Apple App Store on a smartphone. Follow instructions to download and install the application.
Open Source Software Notice Information
To obtain the source code under GPL, LGPL, MPL, and other open source licenses, that is contained in this product, please visit https://opensource.lge.com.
In addition to the source code, all referred license terms, warranty disclaimers and copyright notices are available for download.
LG Electronics will also provide open source code to you on CD-ROM for a charge covering the cost of performing such distribution (such as the cost of media, shipping, and handling) upon email request to opensource@lge.com. This offer is valid for a period of three years after our last shipment of this product. This offer is valid to anyone in receipt of this information.
Industry Canada Statement
This device contains licence-exempt transmitter(s)/ receiver(s) that comply with Innovation, Science and Economic Development Canada's licence-exempt RSS(s). Operation is subject to the following two conditions:
1) This device may not cause interference.
2) This device must accept any interference, including interference that may cause undesired operation of the device.
IC Radiation Exposure Statement
This equipment complies with IC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20 cm (7.8 inches) between the antenna and your body.
NOTE
- THE MANUFACTURER IS NOT RESPONSIBLE FOR ANY RADIO OR TV INTERFERENCE CAUSED BY UNAUTHORIZED MODIFICATIONS TO THIS EQUIPMENT. SUCH MODIFICATIONS COULD VOID THE USER'S AUTHORITY TO OPERATE THE EQUIPMENT.
Wireless LAN Module Specifications
| Frequency Range 2412 | MHz - 2462 MHz |
| Output Power (Max) < 30 dBm | |
Bluetooth module Specifications
| Frequency Range 2402 | MHz - 2480 MHz |
| Output Power (Max) < 30 dBm | |
MAINTENANCE

WARNING
Before cleaning or performing maintenance, unplug the product and wait until the fan stops.
Emptying the Water Collection Tank
When the internal water collection tank is full, the LED display will show FL and the air conditioner will turn off until the tank is emptied.
- Unplug the air conditioner, disconnect the exhaust hose from the back, and move the air conditioner to a suitable drain location or outdoors. You may also place a pan under the drain that will hold up to 2 pints of water.
- Remove the drain cap from the bottom drain outlet.
- Once the water collection tank is drained, reinstall the drain cap, making sure it is on securely.
- Place the air conditioner in the desired location, reconnect the exhaust hose, and plug in the air conditioner.

natural_image
Technical line drawing of a heat exchanger unit with cooling fans and cooling fins (no text or symbols)Cleaning the Case
Wipe the case with a slightly damp cloth, then wipe dry with a dry cloth or towel.
• To prevent damage to the finish, do not use gasoline, benzene, thinners or any abrasive cleansers to clean the air conditioner.
- Never pour water onto or into the air conditioner. It could damage internal components and create a shock and fire hazard.
Cleaning the Air Filter
The air filters should be cleaned every two weeks. Depending on indoor air quality, more frequent cleaning may be needed. A dirty air filter will decrease airflow and reduce efficiency.
- Pull out each air filter by the handle.
-
Use a vacuum cleaner to clean the filters. If the filters are heavily soiled, they can be washed in warm water using a mild detergent.
-
Do not use harsh cleaners or very hot water.
-
Do not wash in a dishwasher.
-
Dry the filters in the shade.
- Reinsert the filters.
NOTE
- Turn off the product and clean the filter after 30 minutes.
- Be careful as hot parts may come into contact with the filter when the filter is removed.

natural_image
Technical line drawing of an air conditioner unit with internal panel structure and external panel views (no text or labels)TROUBLESHOOTING
Before Calling for Service
The appliance is equipped with an automatic error-monitoring system to detect and diagnose problems at an early stage. If the appliance does not function properly or does not function at all, check the following before you call for service.
| Problem Possible Cause Solutions | ||
| Air conditioner does not start. | The air conditioner is unplugged. | Make sure the air conditioner plug is pushed completely into the outlet. |
| The fuse is blown/circuit breaker is tripped. | Check the house fuse/circuit breaker box and replace the fuse or reset the breaker. | |
| Power failure. | If power failure occurs, turn the mode control to off. When power is restored, wait 3 minutes to restart the air conditioner to prevent tripping of the compressor overload. | |
| The current interrupter device is tripped. | Press the RESET button located on the power cord plug. If the RESET button will not stay engaged, discontinue use of the air conditioner and contact a qualified service technician. | |
| FL appears in the display. | The water collection tank is full. Drain the tank and reset your settings. | |
| Air conditioner does not cool as it should. | Airflow is restricted. | Make sure there are no curtains, blinds, or furniture blocking the front of the air conditioner. |
| The temp control may not be set correctly. | Set the desired temperature to a level lower than the current temperature. | |
| The air filter is dirty. | Clean the filter at least every 2 weeks. See the 'MAINTENANCE' section. | |
| The room may have been hot. | When the air conditioner is first turned on, you need to allow time for the room to cool down. | |
| Cold air is escaping. | Check for open furnace floor registers and cold air returns. | |
| Cooling coils have iced up. | See 'Air conditioner freezing up' below. | |
| Air conditioner freezing up. | The cooling coils are iced over. | Ice may block the air flow and obstruct the air conditioner from properly cooling the room. Set the mode control at High Fan or High Cool. |
| Water collects in base pan. | Moisture removed from air and drains into base pan. | This is normal for a short period in areas with little humidity; normal for a longer period in very humid areas. |
| Air conditioner turns on and off rapidly. | Dirty air filter - air restricted. Clean air filter. | |
| Outside temperature extremely hot. | Refer to installation instructions or check with installer. | |
| Noise when unit is cooling. | Air movement sound. | This is normal. If too loud, adjust the fan speed to low. |
| Remote sensing deactivating prematurely. | Remote control not located within range. | Place remote control within 20 feet & 120° radius of the front of the unit. |
| Remote control signal obstructed. | Remove obstruction. | |
| Room too cold. | Set temperature too low. Increase set temperature. | |
NOTE
- If you see "CH" in the display, please call 1 888 542-2623.
Wi-Fi
| Problem Possible Cause Solutions | ||
| Trouble connecting appliance and smartphone to Wi-Fi network. | The password for the Wi-Fi network was entered incorrectly. | Delete your home \Vi-Fi network and begin the registration process again. |
| Mobile data for your smartphone is turned on. | Turn off the Mobile data on your smartphone before registering the appliance. | |
| The wireless network name (SSID) is set incorrectly. | The wireless network name (SSID) should be a combination of English letters and numbers. (Do not use special characters.) | |
| The router frequency is not 2.4 GHz. | Only a 2.4 GHZ router frequency is supported. Set the wireless router to 2.4 GHZ and connect the appliance to the wireless router. To check the router frequency, check with your Internet service provider or the router manufacturer. | |
| The distance between the appliance and the router is too far. | If the appliance is too far from the router, the signal may be weak and the connection may not be configured correctly. Move the router closer to the appliance or purchase and install a Wi-Fi repeater. | |
| Can't connect the LG ThinQ App. to the air conditioner. | Air conditioner is turned off. Turn the wireless router is turned off. Turn the | air conditioner on. |
| router on. | ||
| The air conditioner is not connecting to the Wi-Fi. | The Wi-Fi router is too far from the air conditioner. | Move the router closer to the air conditioner or purchase and install a Wi-Fi repeater (signal booster). |
| You do not have permission to use the router or it is incompatible. | Make sure you are selecting the correct wireless router from the list. The router must be set to 2.4 GHz. | |
WARRANTY
WHAT THIS WARRANTY COVERS:
LG Electronics Canada, Inc. ("LG") warrants your LG Room Air Conditioner ("product") against defect in materials or workmanship under normal household use, during the warranty period set forth below. This limited warranty (except where otherwise prohibited) is valid only to the original retail purchaser of the product, is not assignable or transferrable to any subsequent purchaser or user, and applies only when the product is purchased through an LG authorized dealer or distributor and used within Canada for normal and usual household use.
NOTE
- Replacement products may be new or factory-remanufactured at LG's option and are warranted for the remaining portion of the original unit's warranty period or ninety (90) days, whichever is longer. Please retain dated receipt or delivery ticket as evidence of the date of purchase. If the date of purchase cannot be verified, the warranty period will begin 15 months from the date of manufacture.
Warranty Period:
1 Year from the Date of Purchase.
HOW SERVICE IS HANDLED:
LG will provide a replacement product via an authorized service exchange through the distribution center you originally purchased the product from.
THIS LIMITED WARRANTY DOES NOT COVER:
Service trips to deliver, pick up, or install or set up the Product; Instruction on Product use.
Adjustments of user controls.
Products that have had a serial number or any part thereof altered, defaced or removed.
Property damages, malfunction or failure of the product, or personal injury caused by or resulting from:
(a) accident, abuse, negligence or misuse;
(b) operating the Product in a corrosive or wet environment containing chlorine, fluorine or any other hazardous chemicals;
(c) installation, alteration or service by anyone other than a licensed, authorized LG contractor
(d) improper matching of Product components;
(e) improper sizing or design of the Product;
(f) improper or deferred maintenance contrary to the manufacturer's instructions;
(g) physical abuse to or misuse of the Product (including failure to perform any maintenance as
(h) Product used in other than normal use or in any manner contrary to the Operation Manual;
(i) freight damage or damage caused by force majeure or other factors such as power surge damage or other than pursuant to the manufacturer's instructions, including installation not in accordance described in the Operation Manual such as air filter cleaning, or any Product damaged by caused by lightning and fluctuations in or interruptions of electrical power.
(j) Usage of the product in other than normal and usual household use (including without limitation, commercial use).
THIS LIMITED WARRANTY SHALL NOT BE ENLARGED, EXTENDED OR AFFECTED BY, AND NO OBLIGATION OR LIABILITY SHALL ARISE OR GROW OUT OF, LG PROVIDING, DIRECTLY OR INDIRECTLY, ANY TECHNICAL ADVICE, INFORMATION AND/OR SERVICE TO OWNER IN CONNECTION WITH THE PRODUCT. EXCEPT AS OTHERWISE PROVIDED IN THIS LIMITED WARRANTY, LG MAKES NO OTHER WARRANTIES OR CONDITIONS OF ANY KIND WHATSOEVER REGARDING THE PRODUCT. LG DISCLAIMS AND EXCLUDES ALL WARRANTIES AND CONDITIONS NOT EXPRESSLY PROVIDED HEREIN AND ALL REMEDIES WHICH, BUT FOR THIS PROVISION, MIGHT ARISE BY IMPLICATION OR OPERATION OF LAW, INCLUDING, WITHOUT LIMITATION, THE IMPLIED WARRANTIES AND CONDITIONS OF MERCHANTABILITY AND (EXCEPT IN QUEBEC AND WHERE OTHERWISE PROHIBITED) OF FITNESS FOR ANY PARTICULAR PURPOSE. NO ONE IS AUTHORIZED TO CHANGE THIS LIMITED WARRANTY IN ANY RESPECT OR TO CREATE ANY OTHER OBLIGATION OR LIABILITY FOR LG IN CONNECTION WITH THE PRODUCT. LG DISCLAIMS ALL LIABILITY FOR THE ACTS, OMISSIONS AND CONDUCT OF ALL THIRD PARTIES (INCLUDING, WITHOUT LIMITATION, THE INSTALLING CONTRACTOR) IN CONNECTION WITH OR RELATED TO THE PRODUCT.
UNDER NO CIRCUMSTANCES SHALL LG BE LIABLE FOR ANY INCIDENTAL, SPECIAL, PUNITIVE, EXEMPLARY OR CONSEQUENTIAL DAMAGES INCLUDING, WITHOUT LIMITATION, LOST GOODWILL, LOST REVENUES OR PROFITS, WORK STOPPAGE, PRODUCT FAILURE, IMPAIRMENT OF OTHER GOODS, COSTS OF REMOVAL AND REINSTALLATION OF THE PRODUCT, LOSS OF USE, INJURY TO PERSONS OR PROPERTY ARISING OUT OR RELATED TO THE PRODUCT WHETHER BASED ON BREACH OF WARRANTY, BREACH OF CONTRACT, TORT OR OTHERWISE, EVEN IF LG HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. IN NO EVENT SHALL LG'S LIABILITY EXCEED THE ACTUAL PURCHASE PRICE OF THE PRODUCT WITH RESPECT TO WHICH ANY CLAIM IS MADE.
SOME PROVINCES (INCLUDING QUEBEC) DO NOT ALLOW LIMITATIONS ON WARRANTIES OR EXCLUSIONS OR LIMITATION OF DAMAGES, SO THE ABOVE LIMITATIONS OR EXCLUSIONS MAY NOT APPLY. WHERE ANY TERM OF THIS WARRANTY IS PROHIBITED BY SUCH LAWS, IT SHALL BE NULL AND VOID, BUT THE REMAINDER OF THIS WARRANTY SHALL REMAIN IN EFFECT. THIS LIMITED WARRANTY GIVES THE OWNER SPECIFIC LEGAL RIGHTS AND THE OWNER MAY ALSO HAVE OTHER RIGHTS THAT VARY FROM PROVINCE TO PROVINCE.
HOW TO OBTAIN WARRANTY SERVICE & ADDITIONAL INFORMATION:
Call 1-888-LG-CANADA (542 2623) or visit our website at www.lg.com.
Mail to: LG Electronics Canada Inc.
20 Norelco Drive
North York, ON M9L 2X6
FOR YOUR RECORDS
Write the model and serial numbers here:
Model No.
Serial No.
- You can find them on a label on the side of each unit.
Dealer's Name
Date Purchased
- Staple your receipt to this page in the event you need it to prove date of purchase or for warranty issues.
ARBITRATION NOTICE: THIS LIMITED WARRANTY CONTAINS AN ARBITRATION PROVISION THAT REQUIRES YOU AND LG TO RESOLVE DISPUTES BY BINDING ARBITRATION INSTEAD OF IN COURT, UNLESS THE LAWS OF YOUR PROVINCE OR TERRITORY DO NOT PERMIT THAT, OR, IN OTHER JURISDICTIONS, IF YOU CHOOSE TO OPT OUT. FOR FURTHER CLARITY, THIS ARBITRATION PROVISION IS NOT APPLICABLE TO CUSTOMERS RESIDING IN ONTARIO. IN ARBITRATION, CLASS ACTIONS AND JURY TRIALS ARE NOT PERMITTED. PLEASE SEE THE SECTION TITLED "PROCEDURE FOR RESOLVING DISPUTES" BELOW.
PROCEDURE FOR RESOLVING DISPUTES:
EXCEPT WHERE PROHIBITED AT LAW, ALL DISPUTES BETWEEN YOU AND LG ARISING OUT OF OR RELATING IN ANY WAY TO THIS LIMITED WARRANTY OR THE PRODUCT SHALL BE RESOLVED EXCLUSIVELY THROUGH BINDING ARBITRATION, AND NOT IN A COURT OF GENERAL JURISDICTION. EXCEPT WHERE PROHIBITED AT LAW, YOU AND LG BOTH IRREVOCABLY AGREE TO WAIVE THE RIGHT TO A JURY TRIAL AND TO BRING OR PARTICIPATE IN A CLASS ACTION. FOR CLARITY, THIS PROVISION DOES NOT APPLY TO CONSUMERS RESIDING IN ONTARIO.
Definitions. For the purposes of this section, references to “LG” mean LG Electronics Canada, Inc., its parents, subsidiaries and affiliates, and each of their officers, directors, employees, agents, beneficiaries, predecessors in interest, successors, assigns and suppliers; references to “dispute” or “claim” shall include any dispute, claim or controversy of any kind whatsoever (whether based in contract, tort, statute, regulation, ordinance, fraud, misrepresentation or any other legal or equitable theory) arising out of or relating in any way to the sale, condition or performance of the product or this Limited Warranty.
Notice of Dispute. In the event you intend to commence an arbitration proceeding, you must first notify LG in writing at least 30 days in advance of initiating the arbitration by sending a letter to LGECI Legal Team at 20 Norelco Drive, North York, Ontario, Canada M9L 2X6 (the “Notice of Dispute”). You and LG agree to engage in good faith discussions in an attempt to amicably resolve your claim. The notice must provide your name, address, and telephone number; identify the product that is the subject of the claim; and describe the nature of the claim and the relief being sought. If you are unable to resolve the dispute within 30 days of LG’s receipt of the Notice of Dispute, the dispute shall be resolved by binding arbitration in and LG accordance with the procedure set out herein. You and LG both agree that, during the arbitration proceeding, the terms (including any amount) of any settlement offer made by either you or LG will not be disclosed to the arbitrator until the arbitrator determines the dispute.
Agreement to Binding Arbitration and Class Action Waiver. Upon failure to resolve the dispute during the 30 day period after LG's receipt of the Notice of Dispute, you and LG agree to resolve any claims between you and LG only by binding arbitration on an individual basis, unless you opt out as provided below, or you reside in a jurisdiction that prevents full application of this clause in the circumstances of the claims at issue (in which case if you are a consumer, this clause will only apply if you expressly agree to the arbitration). To the extent permitted by applicable law, any dispute between you and LG shall not be combined or consolidated with a dispute involving any other person's or entity's product or claim. More specifically, without limitation of the foregoing, except to the extent such a prohibition is not permitted at law, any dispute between you and LG shall not under any circumstances proceed as part of a class or representative action. Instead of arbitration, either party may bring an individual action in small claims court, but that small claims court action may not be brought on a class or representative basis except to the extent this prohibition is not permitted at law in your province or territory of jurisdiction as it relates to the claims at issue between you and LG. This does not apply to consumers in Ontario. In accordance with provincial legislation, the consumer and LG may agree to resolve the dispute using any procedure available, including commencing the action in the Superior Court of Justice.
Arbitration Rules and Procedures. To begin arbitration of a claim, either you or LG must make a written demand for arbitration. The arbitration will be private and confidential, and conducted on a simplified and expedited basis before a single arbitrator chosen by the parties under the provincial or territorial commercial arbitration law and rules of the province or territory of your residence. You must also send a copy of your written demand to LG at LG Electronics, Canada, Inc., Attn: Legal Department- Arbitration, 20 Norelco Drive, North York, Ontario M9L 2X6. This arbitration provision is governed by your applicable provincial or territorial commercial arbitration legislation. For consumers in Ontario, the applicable arbitration legislation only applies if consumers agree to submit the dispute to arbitration. Judgment may be entered on the arbitrator's award in any court of competent jurisdiction. All issues are for the arbitrator to decide, except that, issues relating to the scope and enforceability of the arbitration provision and to the arbitrability of the dispute are for the court to decide. The arbitrator is bound by the terms of this provision.
Governing Law. The law of the province or territory of your purchase shall govern this Limited Warranty and any disputes between you and LG except to the extent that such law is preempted by or inconsistent with applicable federal or provincial/territorial law. Should arbitration not be permitted for any claim, action, dispute or controversy between you and LG, you and LG attorn to the exclusive jurisdiction of the courts of the province or territory of your purchase for the resolution of the claim, action, dispute or controversy between you and LG.
Fees/Costs. You do not need to pay any fee to begin an arbitration. Upon receipt of your written demand for arbitration, LG will promptly pay all arbitration filing fees unless you seek more than \$25,000 in damages, in which case the payment of these fees will be governed by the applicable arbitration rules. Except as otherwise provided for herein, LG will pay all filing, administration and arbitrator fees for any arbitration initiated in accordance with the applicable arbitration rules and this arbitration provision. If you prevail in the arbitration, LG will pay your attorneys' fees and expenses as long as they are reasonable, by considering factors including, but not limited to, the purchase amount and claim amount. Notwithstanding the foregoing, if applicable law allows for an award of reasonable attorneys' fees and expenses, an arbitrator can award them to the same extent that a court would. If the arbitrator finds either the substance of your claim or the relief sought in the demand is frivolous or brought for an improper purpose (as measured by the applicable laws), then the payment of all arbitration fees will be governed by the applicable arbitration rules. In such a situation, you agree to reimburse LG for all monies previously disbursed by it that are otherwise your obligation to pay under the applicable arbitration rules. Except as otherwise provided for, LG waives any rights it may have to seek attorneys' fees and expenses from you if LG prevails in the arbitration.
Hearings and Location. If your claim is for \25,000 or less, you may choose to have the arbitration conducted solely (1) on the basis of documents submitted to the arbitrator, (2) through a telephonic hearing, or (3) by an in-person hearing as established by the applicable arbitration rules. If your claim exceeds \25,000, the right to a hearing will be determined by the applicable arbitration rules. Any in-person arbitration hearings will be held at the nearest, most mutually-convenient arbitration location available within the province or territory in which you reside unless you and LG both agree to another location or agree to a telephonic arbitration.
Severability and Waiver. If any portion of this Limited Warranty (including these arbitration procedures) is unenforceable, the remaining provisions will continue in full force and effect to the maximum extent permitted by applicable law. Should LG fail to enforce strict performance of any provision of this Limited Warranty (including these arbitration procedures), it does not mean that LG intends to waive or has waived any provision or part of this Limited Warranty.
Opt Out. The arbitration provision requires you and LG to resolve disputes by binding arbitration instead of court, unless the laws of your province or territory do not permit that, or, in other jurisdictions, if you choose to opt out. The arbitration provision does not apply to consumers in Ontario.
For individuals that fall within the binding arbitration provisions, You may opt out of this dispute resolution procedure. If you opt out, neither you nor LG can require the other to participate in an arbitration proceeding. To opt out, you must send notice to LG no later than 30 calendar days from the date of the first consumer purchaser's purchase of the product by either (i) sending an e-mail to optout@lge.com, with the subject line: "Arbitration Opt Out;" or (ii) calling 1-800-980-2973. You must include in the opt out e-mail or provide by telephone: (a) your name and address; (b) the date on which the product was purchased; (c) the product model name or model number; and (d) the serial number (the serial number can be found (i) on the product; or (ii) online by accessing https://ww-w.lg.com/ca_en/findmodel_serial/). In the event that you "Opt Out", the law of the province or territory of your residence shall govern this Limited Warranty and any disputes between you and LG except to the extent that such law is preempted by or inconsistent with applicable federal or provincial/territorial law. Should arbitration not be permitted for any claim, action, dispute or controversy between you and LG, you and LG agree to attorn to the exclusive jurisdiction of the courts of the province or territory of your residence for the resolution of the claim, action, dispute or controversy between you and LG. You may only opt out of the dispute resolution procedure in the manner described above (that is, by e-mail or telephone); no other form of notice will be effective to opt out of this dispute resolution procedure. Opting out of this dispute resolution procedure will not affect the coverage of the Limited Warranty in any way, and you will continue to enjoy the full benefits of the Limited Warranty. If you keep this product and do not opt out, then you accept all terms and conditions of the arbitration provision described above.
Conflict of Terms. In the event of a conflict or inconsistency between the terms of this Limited Warranty and the End User License Agreement (“EULA”) in regards to dispute resolution, the terms of this Limited Warranty shall control and govern the rights and obligations of the parties and shall take precedence over the EULA.
MANUEL D'UTILISATION
CLIMATISEU

natural_image
Technical line drawing of a two-view electrical component with labeled buttons (RESET and TEST), no text or symbols present.natural_image
Simple line drawing of a rectangular object with a recessed oval cutout (no text or symbols)natural_image
Simple line drawing of a rectangular object with a circular cutout and curved arrows indicating direction (no text or symbols)natural_image
Simple line drawing of a rectangular object with a horizontal grooves (no text or symbols)natural_image
Simple line drawing of a rectangular object with a horizontal edge and rounded top (no text or symbols)natural_image
Simple line drawing of a rectangular object with a circular cutout and a diagonal line, no text or symbols present.Panel A (25")

natural_image
Simple line drawing of a rectangular object with a diagonal line extending from its top edge (no text or symbols)Panel B (25")
natural_image
Line drawing of a portable air conditioner with a coiled hose (no text or symbols)
natural_image
Line drawing of a portable air conditioner with a coiled hose (no text or symbols)natural_image
Technical line drawing of a front-mounted industrial fan or compressor unit with internal ventilation grilles (no text or symbols)
Standard 120 V~, 3-wire grounding receptacle rated 15A / 120 V~ / 60 Hz