Product type Commercial refrigerator
Brand Exquisit
Model ELDC80.3XLB
Climate class 4 (ambient temperature up to 30°C)
Adjustable temperature range 2 to 12 °C
Shelf load capacity 40 kg max per shelf
Interior lighting Replaceable bulb
Refrigerant type Refrigerant gas (CFC-free)
Power supply 230 V, fuse 10 A
Grounding Required: grounded outlet
Extension cord prohibited Do not use extension cord
Delay after power outage Wait 5 minutes before reconnecting
First use Wait 8 hours unplugged after installation
Condenser cleaning Every 3 months with a brush
Interior cleaning Hot water and pH-neutral detergent
Seal maintenance Warm soapy water
Factory-set optimal temperature 0 to 5 °C (depending on model)
Adjustable feet Yes (except with castors option)

Frequently Asked Questions - ELDC80.3XLB Exquisit

How to adjust the refrigerator temperature?
Press the SET button for more than 3 seconds until the display flashes. Then use the UP button to select the desired temperature between 2 and 12 °C.
What to do in case of a power outage?
Wait at least 5 minutes before reconnecting the refrigerator to protect the compressor.
How to clean the inside of the refrigerator?
Unplug the appliance and empty it. Clean with hot water and a pH-neutral detergent. Do not wet the cables or controls. Dry all surfaces thoroughly.
How often to clean the condenser?
The condenser should be cleaned every 3 months with a brush. It is located behind the lower grille. Clean more often if the appliance is in a dusty environment.
Can I use an extension cord?
No, it is forbidden to use an extension cord. If the cable does not reach the outlet, move the appliance or have a new outlet installed by an electrician.
How to replace the interior bulb?
Unscrew the two sides of the lamp cover, then turn the bulb to remove it. Replace it with a bulb of the same wattage.
What to do before first use?
Leave the refrigerator unplugged for 8 hours after installation. Then plug it in and wait 24 hours before adjusting the temperature or placing food inside.
Can I store alcoholic beverages?
Yes, but only in airtight containers or bottles to avoid fermentation risks.
How to maintain the door seals?
Clean the door seals with warm soapy water to maintain their effectiveness.
What to do if the power cord is damaged?
It must be replaced by a qualified technician to avoid any risk of electric shock. Do not attempt to repair it yourself.

User questions about ELDC80.3XLB Exquisit

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Fridge in PDF format for free! Find your manual ELDC80.3XLB - Exquisit and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. ELDC80.3XLB by Exquisit.

USER MANUAL ELDC80.3XLB Exquisit

To ensure safe operation, please read this instruction manual thoroughly before use.

English Page 05

text_image COLDER OFF COLD O I

Reinigung

USERS IN EUROPE This unit must be earthed.

If the power cable is damaged, it must be replaced by a qualified engineer to avoid shock hazard. DO

NOT ATTEMPT TO SERVICE THE ITEM YOURSELF. Ensure that the appliance is properly earthed.

Stop using the appliance immediately if electric shock is felt when touching the chiller.

Thank you for buying this commercial chiller. It has been designed and manufactured for many years of trouble-free service.

Operation is very simple, but please take a few minutes to read this booklet. It contains important safety information, and tips to ensure you receive the best possible service from your chiller.

DISPOSAL OF OLD APPLIANCES

BE SURE TO MAKE ANY LOCKS UNUSABLE. IF POSSIBLE, REMOVE ANY DOOR(S) AND DISCARD SEPARATELY.

WARNING – CHEMICAL HAZARD: DO NOT ALLOW CHILDREN TO PLAY WITH THE OLD APPLIANCE. CONTACT YOUR LOCAL AUTHORITY FOR PROPER DISPOSAL PROCEDURES.

Before disposing of an old appliance, please make sure it is switched off and safe. Unplug the appliance and break any locks in order to avoid children becoming trapped.

Please note: the refrigeration system contains gases and refrigerants which require specialist waste disposal. The valuable materials contained in a refrigerator can be recycled. Contact your local waste disposal depot for proper disposal of an old appliance and contact your local authority or dealer if you have any questions.

Please ensure the pipework of your refrigerator is not damaged prior to disposal. You can contribute to environmental awareness by insisting on an appropriate non-polluting method of disposal.

DISPOSAL OF PACKAGING

Do NOT allow children to play with the packaging, and destroy plastic bags safely.

The cardboard may be broken or cut into smaller pieces and given to a waste paper disposal service. The wrapping foil is made of polyethylene. The polyethylene pads and stuffing contain no fluorochloric hydrocarbons.

All these valuable materials may be taken to a waste collecting depot and used again after adequate recycling. Consult your local authority for the name and address of the waste paper disposal services nearest to you.

IMPORTANT SAFETY INSTRUCTIONS

Before switching on your chiller for the first time, read the information in this user manual carefully. The manual contains important observations relating to the assembly, operation and maintenance of the appliance.

Please keep this booklet in a safe place for future reference. If you ever sell your Gastro-Cool chiller, hand this user manual to the new owner.

The manufacturer does not accept responsibility for any damages that may arise due to non-observation of these instructions. The user is liable for any material damage or bodily injury (product liability) caused by using the refrigerator carelessly or failing to follow instructions.

  • Do not use damaged appliances. If you are in any doubt, consult an engineer.
  • Connection and installation of your Gastro-Cool chiller are to be carried out in strict compliance with the relative instructions in this manual.
  • For safety, the appliance must be properly earthed in accordance with specifications.
  • Do not damage any parts of the appliance which carry refrigerant by piercing, perforating, crushing, twisting or scraping. If the refrigerant comes into contact with the eyes, it may cause serious eye injury.

  • Always remember to unplug the appliance before cleaning. Never unplug your appliance by pulling on the power cable. Always grip plug firmly and pull straight out from the socket. Always check that the plug and cable are undamaged.

  • All repairs must be carried out by qualified engineers. Inadequate repairs may be dangerous. Never try to repair the refrigerator yourself.
  • Should the cover of the interior light or fan fall off or break, switch the refrigerator off immediately and replace cover.
  • Ensure your chosen location has a flat and stable surface. The unit may be levelled by turning either or both of the adjustable feet in the front corners. Check the unit is level using a spirit level.
  • Do not obstruct or cover the ventilation aperture.
  • Do not allow children to play with the appliance, or to sit on it or to hang onto the door(s).

BEFORE USING FOR THE FIRST TIME

Do not position this appliance with its rear panel directly against a wall. For good circulation and operating efficiency, the ventilation grilles must never be blocked.

Remove all packaging (see page 2 for recycling information) and place the chiller on a stable, secure flat surface. Position the chiller away from heat sources, where the unit is well-ventilated and protected from moisture, or extremes of heat or cold. The refrigerator may not function properly if the temperature rises above +30 °C (standard models). The refrigerator meets the operating conditions according to the standard EN 441-4 in climate class 4.

A 10A fuse is fitted. Never replace with a fuse rated higher than this.

NEVER USE AN EXTENSION LEAD. If the mains cable will not reach the nearest socket, either rearrange your store layout or ask a qualified electrician to fit a new socket.

If power is cut off, wait for at least 5 minutes before plugging the unit in again to avoid damaging the compressor.

Do not place combustible, explosive or volatile articles, corrosive acid or alkali, or liquid in glass containers into the chiller. Always exercise caution if adjusting the temperature.

IMPORTANT: allow the refrigerator to stand upright for 8 hours before plugging in.

OPERATION

Place the shelves firmly on their supports. The maximum load for a shelf is 40kg. Check that the refrigerator is functioning properly before installing and filling it. The thermostat or electronic thermocontroller (option) is located inside the unit. An optional light switch is located inside the unit. Never put warm or hot foods directly into the chiller.

ELECTRONIC THERMOCONTROL

The temperature has been pre-set at the factory between 0-10°C, dependent upon model. DO NOT ADJUST THIS WITHIN THE FIRST 24HRS. After 24hrs have lapsed, adjust temperature in gradual stages.

The temperature can be adjusted as follows:

  • Rotate the knob from 1 to cold to make it as colder as you can.
  • Just rotate the knob to the "OFF" when you need to stop the showcase.

Exquisit ELDC80.3XLB - ELECTRONIC THERMOCONTROL - 1

text_image COLDER 3 4 5 6 2 1 DIFF COLD O I

CLEANING

  1. UNPLUG your chiller and remove any stock to a suitable back-up chiller.
  2. Wash the inner compartment with warm water and neutral detergent. DO NOT allow the control panel, cables or plug to get wet.
    NEVER use corrosive detergents, wire brushes, or abrasive scourers to clean your chiller. NEVER use metal or sharp implements to remove debris.

  3. Dry all surfaces thoroughly

  4. To ensure trouble-free operation the condenser should be cleaned every three months where appropriate using a vacuum hose. The condenser is located behind lower grill of the cabinet. In exceptionally dusty locations the condenser should be cleaned more often.

  5. Use mild soapy water to clean the gaskets and seals.

REPLACING LAMPS

Replace interior lights and the illuminated sign with lamps of the same power rating. To remove the lamp cover uncrew both sides and lift out. The fluorescent tube is removed by turning. The fluorescent tube in the illuminated canopy can be changed by simply unfastening the upper canopy and removing the sign.

ATTENTION: RISQUE DE CHOC ELECTRIQUE

THERMOCONTROLE ELECTRONIQUE (OPTION) OU MECHANIQUE

text_image 04 °C SET

NETTOYAGE

REPLACEMENT DE L'AMPOULE

text_image 04 °C SET

ONDERHOUD VAN DE KAST

AFVOER OUDE APPARATEN

Milieu.

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : Exquisit

Model : ELDC80.3XLB

Category : Fridge