ISG 1200-1 Q - Generator Güde - Free user manual and instructions
Find the device manual for free ISG 1200-1 Q Güde in PDF.
User questions about ISG 1200-1 Q Güde
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
Download the instructions for your Generator in PDF format for free! Find your manual ISG 1200-1 Q - Güde and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. ISG 1200-1 Q by Güde.
USER MANUAL ISG 1200-1 Q Güde
natural_image
Black and blue industrial power station kit labeled ISG 1200-1 Q, showing control panel and buttons (no readable text beyond branding)
ISG 1200-1 Q
40715
GÜDE GmbH & Co. KG
Birkichstrasse 6
74549 Wolpertshausen
Deutschland
CE
Güde
®

ENGLISH Please read the instructions carefully before starting the machine.
text_image
Product packaging and specification sheet for a medical device, featuring a black box with blue casing and certification marks.1

natural_image
Exterior view of a black and blue ISG 1200-1 Q power station device (no visible text or symbols on body)2

natural_image
Product photo of a medical or laboratory apparatus including a funnel, screwdriver, and tool (no visible text or symbols)
text_image
TOOL BAGDeutsch Technische Daten / Gerätebeschreibung / Sicherheitshinweise / Bestimmungs-gemäße Verwendung / Verhalten im Notfall / Symbole / Wartung / Entsorgung / Gewährleistung / Service ____ 18
English Technical Data / Device description / Safety Warnings / Specified Conditions of Use / Emergency procedure / Symbols / Maintenance / Disposal / Guarantee / Service ____ 25
Français Caractéristiques techniques / Description du dispositif / Instructions De Sécurité Particulieres / Utilisation conforme aux prescriptions / Conduite en cas d'urgence / Symboles / Entretien / Elimination / Garantie / Service ____ 31
Italiano Dati tecnici / Descripción del dispositivo / Norme Di Sicurezza / Utilizzo conforme / Comportamento in caso d'emergenza / Simboli / Manutenzione / Smaltimento / Garanzia / Servizio ____ 38
Español Datos técnicos / Descripción del dispositivo / Indicaciones de seguridad / Aplicación de acuerdo a la finalidad / Comportamento in caso d'emergenza / Símbolos / Mantenimiento / Eliminación / Garantía / Servicio ____ 44
Nederlands Technische gegevens / Beschrijving van het apparaat / Veiligheidsadviezen / Voorge-schreven gebruik van het systeem / Handelswijze in noodgeval / Symbolen / Onderhoud / Afvoer / Garantie / Service ____ 51
Čeština Technická data /Popis zařízení / Speciální Bezpečnostní Upozornění / Oblast Využití / Chování v případě nouze / Symboly / Údržba / Likvidace / Záruka / Servis ____57
Slovenský Technické údaje /Opis zariadenia / Špeciálne Bezpečnostné Pokyny / Použitie podľa predpisov / Správanie v prípade núdze / Symboly / Údrzba / Likvidácia / Záruka / Servi ____ 63
Polski Dane techniczne / Opis urządzenia / Instrukcje Dotyczące Bezpieczeństwa / Warunki użytkowania / Postępowanie w nagłym przypadku / Symbole / Utrzymanie I Konserwacja / Utylizacja / Gwarancja / Serwis ____ 69
Magyar Műszaki Adatok / Eszközleírás / Rendeltetés szerinti használat / Biztonsági utasítások / Karbantartás / Jótállás ____ 75
Inbetriebnahme
EN starting-up the device FR Mise en service IT Messa in funzione
ES Puesta en marcha NL Toestel in gebruik nemen cz Uvedení do provozu
natural_image
Black and white photo of a portable electronic device labeled '1200-T' with a red X-shaped crossed-out line (no readable text or symbols)
text_image
3 ISG 1200-1 Q min 1m
text_image
4 AC 230kV OBR LOAD OUT FUT AC RESET EN13.5% AC 230kV EN13.5%
text_image
ISG 1200-1 Q
natural_image
Illustration of a blue and black industrial machine with a checkmark indicating inspection or verification (no text or symbols on the device itself)
text_image
2 ISO 1200-1 Q INSERTER 4x
natural_image
Close-up of a black industrial machine with blue control panel and ventilation slots, showing a rightward arrow indicating direction (no text or symbols visible)
natural_image
Close-up of automotive electrical components including wiring, switches, and a lock mechanism (no text or symbols visible)





natural_image
Close-up of an automotive electrical panel with wiring and a highlighted connector (no text or symbols visible)
natural_image
Illustration of a hand holding a piece of paper with a golden object above it (no text or symbols)
natural_image
Illustration of a golden screw with a zigzag handle and a broken arrow symbol, next to a blue vertical line (no text or labels)
text_image
8 MAX MIN
text_image
9 Oil MAX 0,28l 15W40
natural_image
Illustration of a mechanical component with a yellow tool and zigzag line, no text or symbols present
text_image
11 MAX MIN
natural_image
Exterior view of a black and blue ISG 1200-1 Q power station with control panel and digital display (no visible text or symbols on main body)
text_image
2 AC RESET ON ENG.S OFF 0 I ON GROUND
text_image
3 RUN CLOKE 1 COLD START ON 2 OFF4

text_image
ISG 1200-1 Q 1 2
text_image
5 RUN CHOKE COLD STAR ON OFF
text_image
6 2-3 minSTOP
1

natural_image
Black and blue industrial gas generator unit labeled ISG 1200-1 Q, with no visible text or symbols on the device body.
text_image
2 AC RESET R:G.SW. OFF 0 I ON GROUND
text_image
3 RUN CVOKE COLD START ON OFF4

natural_image
Black and blue industrial power unit labeled ISG 1200-1 Q, no visible text or symbols on body





230 V

text_image
RUN CHOKE COLD START ON OFF AC 230V OVER LOAD OUT PUT AC RESET ENG.SW. OFF ON 5V 1A 5V 2.1A GROUND
text_image
230 VUSB

text_image
RUN CVOKE COLD START ON OFF AC 230V OVER LOAD OUT PUT AC RESET ENG.SW. OFF ON 5V 1A 5V 2.1A GROUND 1 A 2.1 A








text_image
1 °C °C 4x
natural_image
Close-up of a mechanical assembly with a metallic component and wiring (no visible text or symbols)
natural_image
Close-up of a mechanical assembly with metallic components and wiring (no visible text or symbols)
text_image
4 ← ↑







5

natural_image
Illustration of a wooden brush and a spark plug, both shown with no text or symbols.6

text_image
0,6-0,8 mm
natural_image
Close-up of a mechanical assembly with a metallic component and wiring (no visible text or symbols)

natural_image
Mechanical component diagram showing a T-shaped tool and a spark plug with a downward arrow (no text or symbols)
natural_image
Close-up of a mechanical assembly with metallic components and wiring (no visible text or symbols)
natural_image
Close-up of a mechanical assembly with a metallic component and wiring, no visible text or symbols







natural_image
Close-up of automotive electrical components including wiring, connectors, and a yellow plastic plug (no visible text or symbols)
natural_image
Interior view of a vehicle's engine bay with visible wiring and components (no text or symbols)
text_image
5 Oil MAX 0,28l 15W40
natural_image
Illustration of a hand holding a piece of paper with a golden object above it (no text or symbols)
natural_image
Illustration of a yellow mechanical component with a zigzag line and number 7, next to a gray rectangular block (no text or symbols)
text_image
8 MAX MIN





text_image
ISG 1200-1 Q
natural_image
Close-up of a printer's internal structure showing the main body and plastic housing (no text or symbols visible)
natural_image
Close-up of a black plastic component with internal compartments, showing a transformation from open to closed state (no text or symbols visible)
text_image
4 H₂O
natural_image
Illustration showing a hand cleaning a surface with water droplets, sunlight shining on it, and a stone block being held by a tool (no text or symbols)
text_image
6 OFF START OFF






text_image
1 ADDITIV EDU
text_image
2 START + STOP 2-3 x 10 min ISG 1200-1 Q year
text_image
3 ISG 1200-1 Q °C °CTechnische Daten
| Inverter power generator ISG 1200-1 Q | |||
| Art. No 40715 | |||
| Starting system Recoil starter | |||
| Mains frequency 50 Hz | |||
| Maximum power 1,2 kW | |||
| Rated power 1 kW | |||
| Power factor cos Φ | 1,0 | ||
| Rated voltage 230 V | ~ | ||
| Rated current 4,3 A | 2,1 A / 1 A | |||
| Output voltage | 1x 230 V | 2x 5 V | ||
| Motor power 1,3 / 1,76 (kW / PS) | |||
| Engine Type 4-stroke motor | |||
| Contents 56 cm3 | |||
| Running time at 50% / 100% load 6 h / 4 h | |||
| Fuel consumption ≤450g/kWh | |||
| Rated speed | 4800 min-1 | ||
| Tank capacity | Petrol | E10/Super/+ | 3,0 l |
| Engine oil | 15W40 | 0,28 l | |
| Emission class | Euro 5 | ||
| Degree of protection | IP 23 M | ||
| Ambient temperature min./max. | -5 °C / 40 °C | ||
| Location height above sea-level | max. 1000 m | ||
| Power class | G2 | ||
| Quality class | B | ||
| Dimensions L x W x H | 336 x 327 x 306 mm | ||
| Net/gross weight | 12,4 / 14 kg | ||
| Noise details | |||
| Sound pressure level LpA | 79,4 dB(A) | ||
| Measured sound power level LWA | 94,8 dB(A) | ||
| Guaranteed sound power level LWA | 95 dB(A) | ||
| Measured according to 2016/1628/EU; 2018/989/EU; Uncertainty K ≤ 1,5 dB (A) | |||
| Wear ear protectors! | |||


Read and understand the operating instructions before using the appliance. Familiarise with the control elements and
how to use the appliance properly. Abide by all the safety measures stated in the service manual. Act responsibly toward third parties.
The operator is responsible for accidents or risks to third parties.
In case of any doubts about connection and operation refer please to our customer center
Persons over 16 years of age can only work on the appliance. An exception includes youngsters trained in order to reach knowledge under supervision of the trainer during occupational education.
This device generates an electromagnetic field which may interact with medical implants. may interact with medical implants. Therefore, persons with medical implants (active and passive) are advised to check with their doctor or the manufacturer of the manufacturer of the implant whether compatibility is guaranteed.
This appliance has not been designed to be used by persons (including children) with reduced physical, sensory or mental capabilities or with a lack of knowledge or experience.
Children must be supervised in order not to play with the machine.
Specified Conditions of Use
This power unit has solely been designed for the operation of electrical equipment with a maximum power within the power unit performance data. Higher starting current of induction appliances must be considered.
The unit has been designed for operation of common effective and induction appliances such as light chains, electric hand tools (drills, electric chain saws, compressors).
Inverter
The technology of the inverter generates the alternating voltage is generated with a clean sine wave. Therefore, inverter power generators are also suitable for sensitive electronic consumers such as computers computers or smartphones.
When connected to a stationary device such as heating, electrical power, air conditioning equipment or for the supply of mobile homes, it is necessary to contact a professional electrician and heating manufacturer as far as connection and grounding is concerned.
Not observing general regulations in force and instructions from this manual does not make the manufacturer liable for damages.
Protective equipment „Protective separation with potential balancing“ is provided and integrated by the producer.
Ensuring that the housing is earthed is necessary to discharge static charges
Please note that our equipment has not been designed for commercial, craft or industrial use. If the equipment is used in commercial, craft or industrial operation or for similar activities, we cannot assume any liability.
The machine may only be used in a technically perfect condition and taking into account all safety information.
The load must not exceed the power marked on the rating label of the generator. Overloading may result in damage to, or a shorter life of the appliance.
CAUTION: Misuse of this generator can damage it or shorten its life!
Use generator only for its intended purposes.
Operate only on dry, level surfaces; do not operate the generator underground. Do not operate the generator in enclosed spaces.
Residual Risk
Even when the device is used properly and all safety regulations are complied with, there still may be some residual risks.
Risk of fire!
Never operate the unit near highly flammable materials.
Fuel is highly flammable.
Keep the fuel in suitable containers only.
The appliance may only be refuelled outdoors and not near open fire or burning cigarettes.
Emergency procedure
After use, let the unit cool down for at least 10 minutes before refuelling.
Make sure the fuel does not overflow. If the fuel overflows, the engine must not be started. Remove any dirt from the appliance and prevent any attempt at ignition until fuel fumes have evaporated..
Replace all fuel tank and container caps securely.
Fuel tank to be emptied outdoors only.
Risk of poisoning!
Exhaust gases, fuel and lubricants are toxic. Inhaling exhaust gases may be fatal!
Do not operate the unit in closed spaces where dangerous carbon monoxide gases may accumulate.
⚠️ Danger of burns!
Some parts of the appliance get too hot when the appliance is operated. Do not touch any hot parts, e.g. engine and muffler.
Contacting hot parts of the unit may cause burns. Do not touch any hot parts, e.g. engine and muffler. Let the unit cool down after its operation is over.
Risk of electric shock.
Direct electrical contact may cause electric shock.
Never touch the unit with wet hands.
⚠ Hearing damage
A longer stay in the immediate vicinity of the running unit may cause hearing damage. Wear ear protectors!
Emergency procedure
Conduct a first-aid procedure adequate to the injury and summon qualified medical attendance as quickly as possible. Protect the injured person from further harm and calm them down. If you seek help, state the following pieces of information:
- Accident site,
- Accident type,
- Number of injured persons
- Injury type(s)
General Safety Rules

WARNING
Read all safety warnings and all instructions. Failure to follow the warnings and instructions may result in electric shock, fire and/or serious injury. Save all warnings and instructions for future reference.
Keep children and bystanders away while operating a power tool. Minimum safe distance is 5 m.
Never let children work with the appliance. Never let adults work with the appliance unless they have been properly trained.
Wear personal protective equipment.
No change can be made in respect of engine and unit setting.

It is strictly prohibited to disassemble, modify and purposely remove the protective equipment of the unit and fit other protective equipment ahead.

The appliance must not be used if damaged or not yet equipment is defective. Replace any turn-out and damaged parts.
Fuel is highly flammable. Refuel the engine only when switched off. The appliance may only be refuelled outdoors and not near open fire or burning cigarettes. Make sure the fuel does not overflow. If the fuel overflows, the engine must not be started. Remove any dirt from the appliance and prevent any attempt at ignition until fuel fumes have evaporated. Store fuel in containers specifically designed for this purpose;
Oil products must not come into contact with skin, eyes and clothing.
Some parts of the appliance get too hot when the appliance is operated. Do not touch any hot parts, e.g. engine and muffler. Contacting hot parts of the unit may cause burns. Pay attention to the warnings on the advice.
Exhaust gases, fuel and lubricants are toxic. Do not operate the unit in closed spaces where dangers carbon monoxide gases may accumulate.
When operating the generator in rooms with good ventilation, the exhaust gases must be channeled directly outdoors through an exhaust hose.
WARNING! Toxic exhaust gases can escape despite the exhaust hose. Due to the fire hazard, never direct the exhaust hose towards inflammable materials.
The motor must not be operated with excessive rotary speed. The operation of the motor with excessive rotary speed raises the risk of injury. Parts which affect the rotary speed must not be altered or replaced.
Electrical safety
Check the device and its electrical components (including cables and plug connections) before use to make sure that there are no defects present.
The power generator may not be connected to other power sources, such as the power supply of the public grid. In specific cases, where a back-up connection to existing electrical systems is provided for, this may be done only
by a qualified electrician, who takes into account the differences between the equipment operated on the public grid and the operation of the power generator.
Do not connect the unit with other energy sources. Do not connect the unit to home network.
Electric supply cables and connected equipment must be in perfect condition.
Protection against electrical shock depends on circuit breakers specially matched to the generating set. If the circuit breakers require replacement they must be replaced with a circuit breaker having identical ratings and performance characteristics.
Due to the high mechanical loads, use only hard-wearing rubber-cased cables (according to IEC 60245-4) or equivalent. Extension cables (H07RN...) approved to be used outdoors and properly marked to be used outdoors only.
The resistance value of 1.5 may not be exceeded if extension cables or portable distributor systems are used.
When using extension cables, their total length may not exceed 50 m in respect of 1.5 mm2 and 100 m in respect of 2.5 mm2. Protective equipment „Protective separation with potential balancing“ is provided and integrated by the producer. Ensuring that the housing is earthed is necessary to discharge static charges
WARNING! Local regulations for electrical safety must be observed
WARNING! Do not use in rainyor wet conditions.
Do not touch bare wires or receptacles (outlets). Electrical equipment (including lines and plug connections) should not be defective.
Due to high mechanical stresses onlytough rubber-sheathed flexible cable or the equivalent should be used.
The user that he shall conform to regulations of electrical safety applicable to the place where the generating sets are used.
Before using the ground terminal, consult a qualified electrician or electrical inspector for local applicable regulations.
Before start-up
Safe operation requires sufficient operator knowledge of the functions and positions of the controls and indicators or meters. Pay attention to the illustrated pages in the front section of the manual.
The appliance should only be used when in a perfect state. Carry out a visual inspection before switching the appliance on. Check especially the safety equipment, electrical control elements, power lines and screw couplings for any damage and if they are tightened appropriately. Replace any damaged parts before the appliance is put into operation if necessary.
The unit may only be operated in the operating position (flat surface) as fuel or oil may leak or lubrication will no longer be provided.
Check the petrol and oil levels and top up if necessary top up.
CAUTION:
When starting up the generator for the first time petrol and engine oil must be filled. (p. 3-6)
Earth the generator. Before using the earth terminal the earth terminal ⑤ to a qualified electrician, to find out the locally applicable regulations.
Always place the appliance on a firm and level surface! surface! Turning and tilting or changing the location during operation are prohibited.
Starting the engine (p. 9)
The power generator has a low oil fuse. If the oil level is too low, it is not possible to start the unit (when trying to start, the oil indicator light ⑦ lights up).
Warning: When starting with the reserve starter, injuries to the hand can occur due to sudden recoil caused by the starting engine.
Wear protective gloves!
- Switch the engine switch
⑥ to ON
• Pull out the choke start)
① (not necessary with a warm
- Turn the fuel tap knob
② to ON.
- Start the engine with the reversing starter by pulling once with little force and a second time strongly. If the engine does not start, pull again.
- When the engine is running, push the choke back in. (not applicable for warm start)
Operation
Generators may only be operated up to their rated power under the rated ambient conditions. The unit must not be exposed to moisture or dust. Permissible ambient temperature -5^ to +40^ , altitude: 1000 m above sea level, relative humidity: 90% (non-condensing). If these values are not observed, there may be a loss of performance. Do not operate the generator in a potentially explosive environment and never cover it.
Caution: Before use, always check whether the consumer is suitable for operation with a generator. Always coordinate the technical data of the consumer with the data and safety instructions of the generator.
Do not exceed the maximum load of the generator. Both in terms of maximum power and continuous power. Note here the possibly high starting current of the consumers.
When connecting several consumers, the consumer with the highest starting current must be connected and started first. The consumer with the lowest starting current last.
- Let the generator run for a few minutes before connecting electrical devices.
- Do not connect the load until the generator is running at full speed.
- Do not overload the generator by connecting more electrical devices than the unit can handle.
- Do not switch on electrical appliances until they have been connected to the generator.
- Switch off all connected electrical equipment before stopping the generator.
• The indicator light running.
⑨ is on while the generator is

Never connect the generator to the house mains!
Switch off the generator (p. 10)
- Disconnect all connected loads.
- Let the generator run for a while without load to cool down.
- Turn the engine switch ⑥ to OFF.
- Turn the fuel tap knob ② to OFF.
Overload protection ⑧
The power generator is equipped with overload protection. This switches off the respective sockets in the event of an overload.
Attention! Should this occur, switch off the unit and reduce the electrical power that you draw from the power generator or remove defective connected devices.
Check the air filter for impurities and remove them if necessary.
Switch off the unit immediately under the following conditions and contact our service department:
- if the engine runs unevenly or not at all smoothly
- in the event of a decrease in the electrical output power
• overheating of the connected load
• Excessive vibrations of the generator
• in the event of sparking
• in the event of smoke or fire
• in the event of unusual vibrations or noises - if the engine appears to be overloaded or misfires. It is possible that the indicator lamp for the overload protection lights up briefly when you operate a consumer with increased starting current. This is not a malfunction.
Transportation and Storage
Before transport, turn the fuel tap to "Off" and remove the spark plug.
During transport, secure the unit against slipping and tipping.
During transport, make sure that no fuel or oil can leak out.
When transporting the machine, use only the transport devices.
Store the machine in a dry place.
Do not park the machine indoors immediately after switching it off, but allow it to cool down outdoors.
Do not operate or store the machine in wet or dampenvironments or on well-conducting surfaces such as metal coatings or steel structures.
Symbols

Caution!

Warning against hot surfaces!
Danger of burns!

Warning against dangerous voltage

Warning against flammable substances

Make sure that there are no persons in the danger zone.

Read the operating instructions to reduce the risk of injury.

Wear ear protectors.!

Symbol for ground connection

Not with too much force

Apply force

Switch off the engine before carrying out any work on the appliance.

Risk of explosion!

Refuel the engine only when switched off.

Risk of poisoning!
Use the appliance only outside, never use it in confined and bad ventilated areas.


Prohibited smoking and open fire using.

Keep dry at all times. Never expose tool to rain.

Always keep children and unauthorised persons out of reach of the appliance.

Electrical or electronic devices that are damaged and/or need to be disposed of must be handed in at the recycling points provided for this purpose.
Dispose of used oil in an environmentally friendly manner.
Make sure that no mineral oil products get into the soil.

Guaranteed sound power level of the unit

CE marking
Maintenance

Switch the engine off and remove the socket plug before any work on the engine. Wait until the unit has cooled down.
Carry out a visual inspection before switching the appliance on.
Check especially the safety equipment, electrical control elements, power lines and screw couplings for any damage and if they are tightened appropriately.
Keep the device, in particular the air vents, clean at all times. Never spray water on the device body!
Do not clean the plastics with solvents, flammable or toxic fluids. For cleaning, use a damp cloth only.
Repairs and works specified in these Instructions may only be performed by qualified authorised staff.
Use only original accessories and original spare parts.
Only a regularly maintained and treated appliance can serve as a satisfactory aid. Insufficient maintenance and care can lead to unforeseen accidents and injuries.
If necessary, a list of spare parts can be found at www.guede.com.
Disposal

Any damaged or disposed devices must be delivered to appropriate collection centres.
Petrol, oil and similar substances must not be released into the environment.
Make sure the oil products do not enter the soil.
Guarantee
Warranty period of 12 months applies to commercial use and 24 months applies to private use and commences on the day of purchase of the device.
The guarantee solely covers inadequacies caused by material defect or manufacturing defect. Original payment voucher with the sales date needs to be submitted for any claim in the guarantee period.
The guarantee does not cover any unauthorised use such as appliance overloading, use of violence, damage as a result of any unauthorised interference or caused by foreign items. Failing to follow the operating and assembly instructions and common wear are also not included in the guarantee.
Important information for the customer
Please note that returns within or outside the warranty period should always be in the original packaging. This measure effectively avoids unnecessary transport damage and any associated disputed ruling. Your equipment is optimally protected only in the original box, and keeping it in that box will ensure smooth processing.
Service
Do you have any technical questions? Any claim? Do you
need any spare parts or operating instructions? We will quickly help you and without needles bureaucracy at our web pages at www.guede.com in the Servicing part. Please help us be able to help you. In order to identify your device in case of claim we need the serial No., product No. and year of production. All this data can be found on the type label.
Tel.: +49 (0) 79 04 / 700-360
Fax: +49 (0) 79 04 / 700-51999
E-Mail: support@ts.guede.com
Inspection and maintenance plan
Repairs and works specified in these Instructions may only be performed by qualified authorised staff. Use only original accessories and original spare parts.
| Regular servicing period Before any | start-up | After the first 10 operating hours | Every 3 months, or after every 50 operating hours | After 6 months | |
| Engine oil(15W40) | Inspection | √ | |||
| Change | √ | √ | |||
| Petrol hoseExhaust systemChokeCable starter | Inspection | √ | |||
| Air filter | Clean | √ | |||
| Change | √ | ||||
| Spark plug | InspectionClean | √ | |||
Tip: To ensure reliable operation of the electric generator, we strongly recommend using fuel additives and performing 2-3 test operations after a longer time of not using the unit.
Failure removal
| Failures | Causes | Removal |
| The motor does not start | Lack of fuel Add some fuel | |
| Bad fuel,Storage without first emptying the petrol tank | Drain the fuel tank and carburettor. Add fresh petrol. | |
| Little oil in the engine Add oil | ||
| Unit is not in a horizontal position. Lack of oil being signalled | Place the device horizontally. | |
| Engine running irregularly Air in the fuel line Vent generators | ||
| Wrong fuel (propellant) Make sure proper fuel has been used. | ||
| Unit not producing any current. | Short circuit Broken cable Loose cable | An error that you can remove yourself. Contact the GÜDE service centre. |
| Engine stopping. | The Starting current is too big. | Reduce the appliance |
| Too long cable Shorten the cable | ||
Motor starten (p. 9)
Translation of the EC-Declaration of Conformity
We, hereby declare the conception and construction of the below mentioned appliances correspond - at the type of construction being launched - to appropriate basic safety and hygienic requirements of EC Directives.
In case of any change to the appliance not discussed with us the Declaration expires.