TD7310 - Bottle warmer TEFAL - Free user manual and instructions
Find the device manual for free TD7310 TEFAL in PDF.
Download the instructions for your Bottle warmer in PDF format for free! Find your manual TD7310 - TEFAL and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. TD7310 by TEFAL.
USER MANUAL TD7310 TEFAL
Important advice on use SAFETY INSTRUCTIONS Please read the instructions for use carefully before using for the first time. For your safety, this appliance complies with applicable standards and regulations (Low Voltage Directive, Electromagnetic Compatibility, Materials in contact with food, Environment, etc.). Your appliance is designed for domestic use only. It is not designed to be used in the following cases, which are not covered by the guarantee: – In staff kitchenettes in shops, offices and other professional environments, – In farms, – By customers in hotels, motels and other residential environments, – In environments such as bed and breakfast. Do not use your appliance if it is not operating correctly or if it has been damaged. In this case, contact an approved T-FAL service centre.
PREVENTION OF DOMESTIC ACCIDENTS
This appliance is not a toy. Children should not be allowed to play with the appliance. Never use the appliance without adult supervision. This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance. The accessible surfaces may become hot when the appliance is in use. Do not touch the hot parts of the appliance. The appliance should be unplugged when not in use and when you are handling it or the accessories. Never place the appliance directly on a fragile surface (glass table, tablecloth, varnished furniture, etc.).
PLUGGING IN YOUR APPLIANCE
Use only the power cord and plug supplied with the appliance. Unwind the power cord fully and always plug the appliance into a ground outlet. Make sure that the electric power supply is compatible with the power rating and voltage indicated on the bottom of the appliance. If the power cord is damaged, it must be replaced by the manufacturer, its aftersales service or any person with similar qualifications, in order to avoid any danger. This appliance is not intended to be operated by means of an external timer or separate remote-control system.
AFTER USING YOUR APPLIANCE
Never immerse the appliance and the power cord in water or place them in the dishwasher. Do not immerse this appliance in water. T-FAL accepts no responsibility, and the guarantee will not apply, for any inappropriate use. TD7310Q0_2000942955_sterilisvapeur 01/12/11 11:12 Page4EN
1. Height-adjustable removable upper support grid
2. Six removable bottle support rods
5. Removable lower support grid
10. Three height adjustment positions for the upper support grid
Precautions on use The various drawings are intended only to illustrate the features of your appliance, and are not to be taken as strictly true to life. Never plug in the appliance without water. Never open the appliance whilst it is in operation, you run the risk of burning yourself. Wait at least 4 minutes after the end of the sterilization cycle before opening the lid. Feeding bottles, comforters and accessories, as well as any other utensils (dummies, spoons etc.) can be sterilised as long as they can stand a temperature of over 203°F / 95°C for a period of 15 minutes. Important: always make sure you clean them thoroughly before sterilising. Caution: bottles, teats and caps will be hot after sterilisation. Please allow at least 4 minutes after the end of the sterilisation cycle before opening the lid, so as to avoid any risk of burning yourself and to ensure complete sterilisation. – Wait 15 minutes between 2 sterilizations in order for appliance to cool between cycles. Using your appliance Before using for the first time Unpack the appliance and its accessories. Clean them. Place the lower grid A at the bottom of the tank. Put the bottle support rods in place (fig. 1). Place the upper grid B (visible marker upwards) into one of the 3 notches provided for adjusting the height. Using a bottle, pour 6,33 fl.oz / 190 ml of water into the tank’s reservoir (fig. 2). Caution, when the appliance is plugged in for the first time, it automatically starts to run a complete cycle. On first use, a slight amount of smoke may be given off. TD7310Q0_2000942955_sterilisvapeur 01/12/11 11:12 Page56
Environment protection first! Your appliance contains valuable materials which can be recovered or recycled. Leave it at a local civic waste collection point. Operation Using a bottle, pour 6,33fl. oz / 190 ml of water into the tank’s reservoir (fig. 2) Comforters, accessories, feeding bottles must be perfectly clean. Load the bottles and accessories to be sterilised. Place the bottles upside down on each rod attached to the grid A as shown on p3. Adjust the height of the grid B according to the size of the bottles. Place the teats without their ring and baby bottle caps onto the upper grid B (see loading diagram fig. 3). Close the lid. Turn the on/off button into position . The button returns automatically to its initial position and the on/off indicator lights up. The sterilisation cycle starts up for approximately 9 minutes. The appliance stops automatically at the end of the cycle. Clean teats, accessories and bottles perfectly before placing them in the steam steriliser. Other utensils, such as spoons, breast pumps, etc. can be sterilised provided that they can withstand a temperature of 203°F / 95°C for 15 minutes. If the sterilising process is interrupted, you must start the cycle again : remove any remaining water, wait for 15 minutes then follow the instructions in the paragraph on how to use. Servicing and descaling – Unplug the appliance and leave it to cool for 10 minutes. – Clean the tank and the lid with a damp cloth. Do not use abrasive products for cleaning or utensils likely to scratch the tank. Wash the grilles and stems with soapy water. – Using a bottle, pour 4,16 fl.oz / 125 ml of water and 4,16 fl.oz / 125 ml of white vinegar into the tank Do not heat. – Wait for 30 mins max. then rinse. – Wipe with a damp rag. Repeat the operation if necessary De-scale your appliance regular (to avoid any risk of incomplete sterilisation). Caution: Do not immerse the appliance in water. The attachments are not dishwasher friendly. For your safety, this appliance conforms to the applicable standards and regulations (Low Voltage, Electromagnetic Compatibility, Materials in contact with foodstuffs, Environmental, etc,…directives.) TD7310Q0_2000942955_sterilisvapeur 01/12/11 11:12 Page67