UXT5236ADQ - Basket MAYTAG - Free user manual and instructions

Find the device manual for free UXT5236ADQ MAYTAG in PDF.

📄 30 pages English EN 💬 AI Question
Notice MAYTAG UXT5236ADQ - page 2
View the manual : Français FR English EN Español ES

Download the instructions for your Basket in PDF format for free! Find your manual UXT5236ADQ - MAYTAG and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. UXT5236ADQ by MAYTAG.

USER MANUAL UXT5236ADQ MAYTAG

  • Safety Instructions p. 1
  • Mounting Heights p. 2
  • Ducting p. 3
  • -7-9 Specifications p. 4
  • Installation -6 Form No. A/04/03 Part No. IMK5558-0303A ©2003 Maytag Appliances Sales Co. Litho U.S.A.Model Number: UXT5230AD* UXT5430AD*UXT5236AD* UXT5436AD*Manufacturer Number: MK5500 MK5800Size: 30” & 36” 30” & 36”INSTALLATION GUIDE Read all Instructions before Installing and operating this appliance MODELS: UXT5230AD* UXT5236AD* UXT5430AD* UXT5436AD* Installation The installation in this manual is intended for qualified installers, service technicians or persons with similar qualified background. DO NOT attempt to install this appliance yourself. Injury could result from installing the unit due to lack of appropriate electrical and technical background. All electrical wiring must be properly installed, insulated and grounded. Overly accumulated grease in old duct work should be cleaned out or duct work should be replaced if necessary to avoid the possibility of a grease fire. Check all joints on duct work to insure proper connection and all joints should be properly taped. p. 5
  • Please check for latest specification revisions before any custom work or cutouts.

MOUNTING HEIGHTS DUCTING 6"36"96"Min 24"-Max 32" Minimum mounting height between range top to hood bottom should be no less than 24". Maximum mounting height should be no high- er than 32". It is important to install the hood at the proper mounting height. Hoods mounted too low could result in heat damage and fire hazard; while hoods mounted too high will be hard to reach and will lose performance and efficiency. If available, also refer to range manufacturer's height clearance requirements and recom- mended hood mounting height above range. A minimum of 6” round or 3-1/4”x10” rectangular duct must be used to maintain maximum air flow efficiency. Always use rigid-type metal ducts only. Flexible ducts could restrict air flow by up to 50%. Also use calculation (on right) to compute total available duct run when using elbows, transitions and caps. ALWAYS, when possible, reduce the number of transitions and turns. If long duct run is required, increase duct size from 6” to 7 or 8”. If a reducer is used, install a long reducer instead of a pancake reducer. Reduce duct size as far away from open- ing as possible. If turns or transitions are required: Install as far away from opening and as far apart, between 2, as possible. *Minimum clearance of 24” hood above range height. ** Maximum clearance 32" hood above range height. Minimum Duct Size:Round:6” minimum Rectangular:3-1/4”x10”Duct Run Calculation:Maximum run6” or 3-1/4” x 10” duct Deduct:each 90 Elbow used each 45 elbow used each 6” to 3/14 x 10”transition used each 3/14 x 10” to 6”each 3/14 x 10” to 6”transition used Side Wall Cap w/ damper Roof Cap 100 FT15 FT 9 FT 1 FT 5 FT 30 FT30 FTe.g.- 1 roof cap, 2x90 elbows, 1 45 elbow used:=30' + 30' + 9' =69' used, 31' available for straight duct runs.INSTALLATION

DUCTING NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or garages. All exhaust must be ducted to the outside. Use Metal ductwork only. Fasten all connections with sheet metal screws and tape all joints w/ certified Silver Tape or DuctTape. Some Ducting Options: side wall capw/ gravity damperside wall capw/ gravity damperSoffit or crawl spaceRoof Pitch w/ Flashing & Cap

7 3/4" 30" or 36" 15 5/8" 10 1/4" 1 3/4"

MOUNTING THE RANGEHOOD

ELECTRICAL All Electrical work must by performed by qualified electrician or person with similar technicalknow how and background.For personal safety, remove house fuse or open circuit breaker before beginning installation.Do not use extension cord or adapter plug with this appliance.Follow National electrical codes or prevailing local codes and ordinances.Electrical Supply:This appliance requires a 120V 60Hz electrical supply, connected to an individual, properly groundedbranch circuit, protected by a 15 or 20 ampere circuit breaker or time delay fuse. Wiring must be 2wire w/ ground. Please also refer Electrical Diagram labeled on product.Cable Lock:A cable locking connector (not supplied) might also required by local codes. Check with localrequirements and codes, purchase and install appropriate connector if necessary. Cable Lock WARNINGINSTALLATION

MOUNTING THE RANGEHOOD

1. This range hood is mounted under a

kitchen cabinet unit.

2. Select preferred duct location on rear or

top of unit. For ductless conversion, no ducting is required.

3. Begin installation by temporarily removing

the diffuser and filter panels.

4. Temporarily position the range hood in

the desired mounting location. Measure and mark the mounting holes, duct and electrical access locations with a pencil.

5. Drill/cut out the required openings for

duct and electrical access; make sure the duct opening is large enough to apply duct tape.

6. Fasten mounting screws onto

cabinet as marked, do not tighten, leaving half length of screws exposed.

7. Install electrical.

8. Hang hood onto screws through key

9. Install duct work and duct-tape.

10. Reinstall the difuser panels.

11. Power up hood and check for leaks

around duct-tape. duct/silver tapeINSTALLATION

CONVERTIBLE OPTIONS This range hood is equipped with the option of a 6” vertical discharge, 3 1/4”x10” vertical discharge, or 3 1/4”x10” rear discharge. Additional accessories are provided to convert to either of the above discharge methods. Convertible Options Vertical discharge 6” round Vertical discharge 3 1/4”x10” Horizontal rear discharge 3 1/4”x10” Convertible Accesories Round to rectangular transition adaptor Rectangular to round transition adaptor Gasket (pre-mounted) Rectangular rear cap (pre-mounted) 3 1/4”x10” starting collar 3 1/4”x10” Vertical Discharge 1. Remove pre-mounted 6” transition adaptor or ductopening. Leave attached gasket in its original place.3. Mount the 3-1/4”x10” starting collar on top of transition piece with remaining screws.2. Place rectangular transition adaptor as shown overgasket and by first installing 4 screws on half roundsection. (pre-mounted)INSTALLATION

1. At rear of range hood, remove all screws on pre-

mounted rear rectangular cap and remove cap.

5. Mount starting collar (provided) at rear discharge

opening with gasket.

4. Mount rectangular cap (previously removed) on top

of transition adaptor.

3. Mount rectangular transition piece at opening with

2. Remove top pre-mounted transition piece. Leave

attached gasket in its original place.INSTALLATION

DUCTLESS CONVERSION Ductless conversion is intended for applications where an exhaust duct work is not possible to be installed. When converted, the hood functions as a "purifying" hood rather than an exhaust hood. Fumes and exhaust from cooking are drawn and filtered by a set of optional Carbon Filters. The air is then purified and re-circulated back within the home. We recommend to ALWAYS exhaust air outside of the home by employing existing or installing new duct work, if possible. The hood is most effective and efficient as an Exhaust unit. Only when the exhaust option is not possible should you recourse to converting the hood into a "purifying"unit. When converted to be a "purifying" unit, a Carbon Filters Kit is required. Order according to its Part number below. The standard Metal Filters are intended to capture residue from cooking and the optional Carbon Filters help to purify fumes exhausted from cooking for re-circulation. Carbon Filters (Required)

1. Purchase ductless Carbon Filters Kit as follow:

2. The ductless conversion housing must be

installed prior to installation of the range hood.

3. Remove the diffuser panels on the hood.

4. Clip carbon filter onto bracket of

5. Re-install diffuser panels.

6. Carbon Filters must be replaced after

every 120 hours of use (or approximately every 2 to 3 months based on the average of 1-2hrs. of daily cooking time).

7. Refer installation manual provided with

7 3/4" 30" or 36" 15 5/8" 10 1/4" 1 3/4"

7 3/4" 30" or 36" 15 5/8" 10 1/4" 1 3/4"

Manual assistant
Powered by ChatGPT
Waiting for your message
Product information

Brand : MAYTAG

Model : UXT5236ADQ

Category : Basket