Product Type Rack-mountable Uninterruptible Power Supply (UPS)
Brand APC
Model Smart-UPS SMTL1500RM3UC
Apparent Power 1500 VA
Active Power 1350 W
Input Voltage 120 V
Output Voltage 120 V
Waveform Pure Sine Wave
Battery Technology Lithium-ion
Number of Batteries 4
Dimensions (H x W x D) 132 x 432 x 470 mm
Weight 22 kg
Rack Mounting Yes, 3U
Connectivity SmartConnect (Ethernet) for remote monitoring
Key Features Surge protection, automatic voltage regulation (AVR), intelligent battery management
Maintenance and Cleaning Minimal maintenance, sealed battery; clean with a dry cloth
Safety Compliant with UN38.3, short-circuit, overload, and deep discharge protection
Spare Parts and Repairability Replacement battery cartridge (ref. 914-0001)
General Information Designed for servers, networks, and critical equipment; 3-year warranty

Frequently Asked Questions - SmartUPS SMTL1500RM3UC APC

How to install the APC Smart-UPS SMTL1500RM3UC in a rack?
Attach the provided mounting brackets to the sides of the UPS, then slide it into the rack ensuring it is well supported. Use the screws to secure it. Then plug in the power cord and equipment.
What is the battery runtime on this UPS?
The runtime depends on the connected load. For a 500 W load, expect about 10 to 15 minutes. At full load (1350 W), it is approximately 3 to 5 minutes. Consult the PowerChute software for accurate estimates.
How to replace the battery of the APC SMTL1500RM3UC?
The UPS uses a lithium-ion battery cartridge referenced 914-0001. To replace it, disconnect the UPS, remove the front panel, disconnect the cables, remove the old battery and insert the new one respecting polarities. Reconnect and power on.
What does the SmartConnect LED on the UPS mean?
The SmartConnect LED indicates the connection status to the APC cloud service. Solid green means the connection is active. Flashing or orange indicates a network or configuration issue.
Can I connect this UPS to my computer via USB?
No, this model does not have a USB port. It uses SmartConnect via Ethernet for communication. You can install PowerChute software on a server for advanced management.
What is the warranty of the APC Smart-UPS SMTL1500RM3UC?
APC offers a standard 3-year warranty for the UPS and 2 years for the lithium-ion battery. The warranty covers manufacturing defects and failures, but not damage from misuse.
How to test the proper operation of the UPS?
Press the 'Test' button on the front panel. The UPS will switch to battery mode and the test LED will illuminate. If the test fails, check the battery or contact technical support.
What to do in case of a prolonged power outage?
The UPS will provide limited runtime. If the battery discharges, the UPS will shut down automatically. To protect your equipment, configure an automatic shutdown via PowerChute. After power returns, the UPS will recharge.
How to clean the UPS and how often?
Disconnect the UPS before cleaning. Use a soft, dry cloth to remove dust from the casing and ventilation grilles. Avoid liquids. Cleaning every 6 months is recommended.
Where can I buy spare parts for this UPS?
Spare parts, including the battery (ref. 914-0001), are available from authorized APC resellers or on the official website. You can also contact customer service for references.

User questions about SmartUPS SMTL1500RM3UC APC

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Uninterruptible power supply in PDF format for free! Find your manual SmartUPS SMTL1500RM3UC - APC and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. SmartUPS SMTL1500RM3UC by APC.

USER MANUAL SmartUPS SMTL1500RM3UC APC

1.0 Products covered by this Test Summary

Model NumberDescriptionNotes
SMTL1000RM2UCAPC Smart-UPS Lithium Ion, Short Depth 1000VA, 120V with SmartConnect3 x 914-0001
SMTL1000RMI2UAPC Smart-UPS Lithium Ion, Short Depth 1000VA, 230V3 x 914-0001
SMTL1000RMI2UCAPC Smart-UPS Lithium Ion, Short Depth 1000VA, 230V with SmartConnect3 x 914-0001
SMTL1000RMI2UNCAPC Smart-UPS Lithium Ion, Short Depth 1000VA, 230V with Network Card3 x 914-0001
SMTL1500RM3UCAPC Smart-UPS Lithium Ion, Short Depth 1500VA, 120V with SmartConnect4 x 914-0001
SMTL1500RMI3UAPC Smart-UPS Lithium Ion, Short Depth 1500VA, 230V4 x 914-0001
SMTL1500RMI3UCAPC Smart-UPS Lithium Ion, Short Depth 1500VA, 230V with SmartConnect4 x 914-0001
SMTL1500RMI3UNCAPC Smart-UPS Lithium Ion, Short Depth 1500VA, 230V with Network Card4 x 914-0001
SMTL1K5R3CX180APC SMART-UPS Li-ion Short Depth 1500VA 120V With SmartConnect and NMC4 x 914-0001
SMTL750RM2UCAPC Smart-UPS Lithium Ion, Short Depth 750VA, 120V with SmartConnect2 x 914-0001
SMTL750RMI2UAPC Smart-UPS Lithium Ion, Short Depth 750VA, 230V2 x 914-0001
SMTL750RMI2UCAPC Smart-UPS Lithium Ion, Short Depth 750VA, 230V with SmartConnect2 x 914-0001
SMTL750RMI2UNCAPC Smart-UPS Lithium Ion, Short Depth 750VA, 230V with Network Card2 x 914-0001

Physical Description of Products

Each product consists of an Uninterruptible Power Supply (UPS) that contains two or more lithium ion batteries (914-0001). Each lithium ion battery is less than 100 WH and contains individual cells that are each less than 10 WH.

1.1 Batteries in Products

#Model NumberDescriptionNotes
1ALM000008-01,PSL000005,914-000112V, 5 AH LI-ION EMULATOR
2ZE18017,914-000112V, 5 AH LI-ION EMULATOR

1.2 Cells in Batteries

#Model NumberDescriptionNotes
3ANR26650M1-B3.3 Volts, 2.5 Ah Cylindrical Battery,LithiumWerks NanophosphateIn 2018 LithiumWerks assumed the right to make A123 Batteries
426650 P FSLithium ion Rechargeable cell, 3000 mAH,LiFePO4 series cathode

2.0 Manufacturers of Cells/Batteries

2.1 Battery Maker #1

NameAddressPhoneWebsite
NEC Energy Solutions (AsteelFlash Suzhou Ltd)No.8 Gutang Road, Wetdz, Wujiang District, Suzhou, JIANGSU 215200+86 512 6340 8000https://www.asteelflash.com/facility/asteelflash-suzhou/
NOTES:

2.1 Battery Maker #2

NameAddressPhoneWebsite
Shenzhen Ace Battery Co. Ltd. 5^th Floor, No. 2 Lanjing Middle Road, Oongtian Street, Pingshan District, Shenzhen, Guandong, China+86 755 8328 3710Email:info@cbakbattery.comNo Website
NOTES:

2.1 Cell Maker #3

NameAddressPhoneWebsite
LithiumWerks18#, BeiHai Road, CZEPE Changzhou New District Jiangzu, PRC, 213031+1 512 527-2900 (U.S. Office)https://lithiumwerks.com/
NOTES:

2.1 Cell Maker #4

NameAddressPhoneWebsite
DALIAN CBAKPOWERBATTERY COMPANYLIMITED11 Meigui Street (East),Huayuankou Economic Zone,Dalian, China, 1164500411-39185999http://www.cbak.com.cn/
NOTES:

3.0 Test Laboratories of Cells / Batteries

3.1 Test for Battery #1

NameAddressPhoneWebsite
Shanghai Research Institute of Chemical Industry Testing Co. Ltd.East Yunling Road No. 345Building A Room 717,SHANGHAI, CHINA+021 5281 53770102http://www.sricims.com/
Test ID No:1115120 333
Date:December 29, 2015
NOTES:
Lithium Ion Cell
XXXLithium Ion Battery
Lithium Metal Cell
Lithium Metal Battery

3.1 Test for Battery #2

NameAddressPhoneWebsite
GUANGDONG UTL CO., LTD.Lianding Testing Building, No.18 Center Road of Yayuan Industrial Zone, Nancheng District, Dongguan, Guangdong, China+86-769-3893 3228E-mail: sales@gdutl.com Website: http://www.gdutl.com
Test ID No:19PNS050009 03001
Date:July 22, 2019
NOTES:
Lithium Ion Cell
XXXLithium Ion Battery
Lithium Metal Cell
Lithium Metal Battery

3.1 Test for Battery #3

NameAddressPhoneWebsite
Shanghai Research Institute of Chemical Industry Testing Co. Ltd.East Yunling Road No. 345Building A Room 717,SHANGHAI, CHINA+021 5281 53770102http://www.sricims.com/
Test ID No:1118070067

Date: August 8, 2018

NOTES: Retest of battery cell after change of ownership of battery maker.

XXXLithium Ion Cell
Lithium Ion Battery
Lithium Metal Cell
Lithium Metal Battery

4.0 Parameters of Cells/Batteries

4.1 Test for Battery #1

ParametersCellBattery
Mass in gram (g)76932
Lithium ion Indicate watt-hour rating (Wh)0.7366
Lithium metal Indicate lithium metal content in gram (g)N/AN/A

Physical Description of Cells / Batteries

914-0001 and Cell:

NEC NEC DENTY SOLUTIONS ALM 12V7

4.1 Test for Battery #2

ParametersCellBattery
Mass in gram (g)99.1949
Lithium ion Indicate watt-hour rating (Wh)3.076.8
Lithium metal Indicate lithium metal content in gram (g)N/AN/A

Physical Description of Cells / Batteries

914-0001 and Cell:

APC SmartUPS SMTL1500RM3UC - Physical Description of Cells / Batteries - 1

natural_image Two battery components: a black battery with red label and a blue cylindrical battery on a ruler for scale (no visible text or symbols)

5.0 List of tests conducted and results

TestPassFailN/A
T1 – Altitude simulationX
T2 – Thermal TestsX
T3 – VibrationX
T4 – ShockX
T5 – External Short CircuitX
T6 – Impact - for cylindrical cells having a diameter of at least 18mm. See Section 6.0X
T6 – Crush - for prismatic cells, pouch cells, button cells and cylindrical cells having a diameter of less than 18mm. See Section 6.0X
T7 – OverchargeX
T8 – Forced DischargeX

6.0 UN38.3 Test Conformation for the Cells inside the battery:

Cell UN 38.3 Test Confirmed (Yes or No)
When no separate document for the cells is provided, this confirms that the cells inside the battery have successfully passed the UN 38.3 test. In this case under section 5.0 the T6 and T8 must be marked as “passed” and here under section 6.0 “Cell UN 38.3 Test confirmed” needs to be Yes.YES

7.0 Reference to assembled battery testing requirements

Not Applicable
XXX

8.0 Reference to the edition on the Manual of Tests and Criteria applied

ST/SG/AC.10/11/Rev.5/Amend.1

Recommendations on the Transport of Dangerous Goods:

Manual of Tests and Criteria, Part III, Sub-Section 38.3

Lithium metal and lithium ion batteries

United Nations

9.0 Manufacture of the cell / battery is in accordance with quality management system as required by the regulations:

Schneider Electric certifies that all articles described in this Test Survey are in compliance with all applicable Schneider Electric Product Specifications, Manufacturing Processes, Quality Control Testing, Quality Plan per ISO9001: 2008, and Environmental guidelines.

10.0 Certification

Company: Schneider Electric – Secure Power Division Signature:

APC SmartUPS SMTL1500RM3UC - Certification - 1

Authorized representative:

Schneider Electric • SPBusiness Schneider Electric OFFICIAL DOCUMENT APC APC by Schneider Electric Seal

Raymond P. Lizotte, Jr.

Director, Sustainability Office

EMAIL: raymond.lizotte@SE.com

Date of compilation: February 20, 2020

Place of expertise: Schneider Electric Andover R&D Center

Andover, MA 01810

United States

11.0 Attachments

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : APC

Model : SmartUPS SMTL1500RM3UC

Category : Uninterruptible power supply