MELINERA Z31656A - Lampe funéraire

Z31656A - Lampe funéraire MELINERA - Free user manual and instructions

Find the device manual for free Z31656A MELINERA in PDF.

📄 61 pages English EN 💬 AI Question
Notice MELINERA Z31656A - page 6
View the manual : Français FR Deutsch DE English EN Nederlands NL

Download the instructions for your Lampe funéraire in PDF format for free! Find your manual Z31656A - MELINERA and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. Z31656A by MELINERA.

USER MANUAL Z31656A MELINERA

75 GB/IE/NI Introduction ..................... Page 6 Intended use .......................... Page 6 Parts description .................... Page 7 Technical Data ...................... Page 7 Scope of delivery .................. Page 8 General safety instructions ....................... Page 8 Battery safety information ..... Page 9 Initial use ........................... Page 11 Replacing batteries ... Page 13 Cleaning and Care ..... Page 14 Disposal instructions ....................... Page 14 Warranty ........................... Page 166 GB/IE/NI LED Grave Light Introduction We congratulate you on the purchase of your new product. You have chosen a high quality product. The instructions for use are part of the product. They contain important information concerning safety, use and disposal. Before using the prod- uct, please familiarise yourself with all of the safety information and instructions for use. Only use the unit as described and for the specified applications. If you pass the product on to anyone else, please ensure that you also pass on all the documentation with it. Intended use This product is suitable for grave decora- tion only. The product is not intended for commercial use or in other application.7 GB/IE/NI Not suitable for ordinary lighting in household room illumination. Parts description

Battery compartment Technical Data Operating voltage: 3 V , approx. 0.012 W Lamp: 1 LED (LED not replaceable) Batteries: 2 x 1.5 V

LR14 (Type C) Light on time: approx. 180 days8 GB/IE/NI Chromaticity coordinate: X > 0.530 Scope of delivery 1 Grave light 2 Batteries (preinstalled) 1 Set of operating instructions General safety instructions Please familiarise yourself with all operating and safety instructions be- fore using this product! When pass- ing this product on to others, please also include all the documents! This appliance can be used by chil- dren aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the9 GB/IE/NI appliance in a safe way and under- stand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision. Do not put this device in water or other liquids. Always place the product, that it cannot fall into a tub or sink. Never fill the container with liquid. Do not use the product if you notice any damages. The illuminant is not replaceable. If the illuminant fails at the end of its life, the entire light must be replaced. Battery safety information DANGER TO LIFE! Batteries are not intended for chil- dren. If accidentally swallowed seek immediate medical attention!10 GB/IE/NI CAUTION! EXPLO- SION HAZARD! Never recharge non- rechargeable batteries, shortcircuit and / or open batteries! Never throw batteries into fire or water! Do not exert mechanical loads to batteries! Risk of battery leakage In the event of a battery leak, imme- diately remove it from the device to prevent damage! Avoid contact with the skin, eyes and mucous membranes! In the event of contact with battery acid, thoroughly flush the affected area with plenty of clean water and seek immediate medical attention! Only use the same type of batteries! Do not mix used and new batteries! Avoid extreme conditions and tem- peratures which may impact batter- ies, e.g. radiators!11 GB/IE/NI Remove batteries from the device after extended periods of non-use! Risk of equipment damage Only use the specified battery type! When inserting the battery ensure the correct polarity! This is shown in the battery compartment! If necessary, clean the batteries and device contacts before inserting batteries! Promptly remove drained batteries from the product! Initial use Note: Risk of short circuit! Make sure that the lid is always closed properly and securely, in or- der to prevent rain or moisture get into the container and cause a short circuit. Make sure the lid shows no dam- ages. Do not use the product if the lid is damaged.12 GB/IE/NI Remove the grave light cover

from the grave light housing

. It is clipped on. Remove the small polystyrene block inside. This is only for transport safety. Remove the battery casing

and slide off the battery casing cover

This is clipped on. Carefully remove the battery com- partment

Remove the insulating strip inside. This is only for transport safety. Slide the battery compartment back into the battery casing and replace the battery casing cover. Place the battery casing back inside the grave light housing. Switch on the grave light using the ON/OFF switch

(setting ON) or off (setting OFF). The LED will flicker to simulate can- dlelight. Close the grave light housing with the grave light cover.13 GB/IE/NI Replacing batteries Note: when using alkaline batteries the batteries should be replaced approxi- mately every 180 days. To do so, remove the grave light cover

from the grave light hous- ing

and remove the battery housing

Switch the grave light off with the ON/OFF switch

(setting OFF). Carefully remove the battery casing cover

Remove the battery compartment

Manual assistant
Powered by ChatGPT
Waiting for your message
Product information

Brand : MELINERA

Model : Z31656A

Category : Lampe funéraire