HWR18VCJ - Air Conditioning HAIER - Free user manual and instructions
Find the device manual for free HWR18VCJ HAIER in PDF.
Download the instructions for your Air Conditioning in PDF format for free! Find your manual HWR18VCJ - HAIER and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. HWR18VCJ by HAIER.
USER MANUAL HWR18VCJ HAIER
INSTALLATION REQUIREMENTS Tools and Parts You can be killed or seriously injured if you don't immediately You can be killed or seriously injured if you don't follow All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can happen if the instructions are not followed. Your safety and the safety of others is very important. We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages.This is the safety alert symbol.This symbol alerts you to potential hazards that can kill or hurt you and others.All safety messages will follow the safety alert symbol and either the word “DANGER” or “WARNING.”These words mean:follow instructions.instructions. DANGER WARNING
To reduce the risk of fire, electrical shock or injury when using your air conditioner, follow these basic precautions:
SAVE THESE INSTRUCTIONS
Unplug air conditioner before servicing.Use two or more people to move and install air conditioner.Plug into a grounded 3 prong outlet.Do not remove ground prong.Do not use an adapter.Do not use an extension cord.Gather the required tools and parts before starting installation. Read and follow the instructions provided with any tools listed here.Tools neededParts supplied:Check that all parts are included in parts package. ■ Phillips head screwdriver ■ Flat-blade screwdriver ■ Scissors ■ Level ■ Socket wrench and sockets ■ Tape measure ■ Cordless drill and 1/8” bit ■ Pencil ■ Pliers ■ Adjustable wrench
A. Top rail B. Foam seal C. Installation brackets (left and right) D. Window lock bracket E. ⁄” screws (12) F. ⁄” bracket screws (6) G. ⁄” screws (8) H. 1/2” Long flat head bolt and locknut(2)
I. Left and right side curtains
J. Remote control4 Location Requirements IMPORTANT: Observe all governing codes and ordinances. Check the location where the air conditioner will be installed. Make sure you have everything necessary for correct installation. The location should provide: ■ Grounded electrical outlet within 4 ft (122 cm) of where the power cord exits the air conditioner. NOTE: Do not use an extension cord. ■ Free movement of air in room to be cooled.■ A large enough opening for the air conditioner. Installation parts are supplied for double-hung windows. ■ Adequate wall support for weight of air conditioner. Air conditioner weighs 109.4 lbs to 123.7 lbs (49.6 kg to 56.1 kg). NOTE: Cabinet louvers must not be obstructed. Air must be able to pass freely through the cabinet louvers. The electrical ratings for your air conditioner are listed on the model and serial number label. The model and serial number label is located either on the side or back of the air conditioner cabinet or behind the front grille. Specific electrical requirements are listed in the chart below. Follow the requirements for the type of plug on the power supply cord. This air conditioner must be grounded. This air conditioner is equipped with a power supply cord having a 3 prong grounding plug. The cord must be plugged into a mating, grounded 3 prong outlet, grounded in accordance with all local codes and ordinances. If a mating outlet is not available, it is the customer’s responsibility to have a properly grounded 3 prong outlet installed by a qualified electrical installer. It is the customer’s responsibility: ■ To contact a qualified electrical installer. Electrical Requirements A. Cabinet louvers
173⁄8” (44.1 cm) minimum Window Installation Recommended Grounding Method Power Supply Cord Wiring Requirements Window opening measurements: ■ 283⁄8” minimum to 38” (72.1 cm to 96.5 cm) maximum opening width. ■ 173⁄8” (44.1 cm) minimum opening height.
■ 208/230-volt (187 min. to 253 max.)■ 0 to 12 amps■ 15-amp time-delay fuse or circuit breaker ■ Use on single outlet circuit only.5 NOTE: Your air conditioner’s device may differ from the one shown. This room air conditioner is equipped with a power supply cord required by UL. This power supply cord contains state-of-the-art electronics that sense current leakage. If the cord is crushed, the electronics detect current leakage and power will be disconnected in a fraction of a second. Remove Packaging Materials ■ Remove and dispose of/recycle packaging materials. Remove tape and glue residue from surfaces before turning on the air conditioner. Rub a small amount of liquid dish soap over the adhesive with your fingers. Wipe with warm water and dry. ■ Do not use sharp instruments, rubbing alcohol, flammable fluids, or abrasive cleaners to remove tape or glue. These products can damage the surface of your air conditioner. ■ Handle the air conditioner gently. To test your power supply cord:
1. Plug power supply cord into a grounded 3 prong outlet.
2. Press RESET (on some devices, a green light will turn on).
3. Press TEST (listen for click; Reset button will trip, and on
some devices, a green light will turn off).
4. Press and release RESET (listen for click; Reset button will
latch, and on some devices, a green light will turn on). The power supply cord is ready for operation. NOTES: ■ The Reset button must be pushed in for proper operation.■ The power supply cord must be replaced if it fails to trip when the test button is pressed or fails to reset. ■ Do not use the power supply cord as an off/on switch.■ A damaged power supply cord must be replaced with a new power supply cord obtained from the product manufacturer and must not be repaired. ■ The power supply cord contains no user serviceable parts. Opening the tamper-resistant case voids all warranty and performance claims. A. Test buttonB. Reset button Power Supply Cord Prepare unit for installation INSTALLATION INSTRUCTIONS Unpack the Air Conditioner Prepare Air Conditioner for Installation TEST RESET
Unpack unit on the floor next to installationlocation.
1. Remove two front attachment screws.Separate the outer case
from the front with a putty knife at the catch points designated by the arrows.
2. Remove the four screws on both sides of the outer case.
3. Using the basepan handle, slowly and evenly pull chassis out
NOTE: Cover putty knife blade with masking tape to guard against damage of the unit finish. CAUTION:Never expose plastic front or grille to extreme temperatures. NOTE: Attach curtains to the air conditioner before placing the air conditioner in window.
1. Install top rail with four 13/32” screws.
2. Slide left-hand curtain assembly into left end of top and bottom
rails. Repeat for right-hand curtain assembly.
3. Fasten curtain retainer strips to the sides of the outer case with
eight 13/32” screws.. NOTES: Handle the air conditioner gently. Be sure your air conditioner does not fall out of the opening during installation or removal. The place where the power cord exits the air conditioner should be no more than 4 ft (122 cm) from a grounded outlet. Do not block the louvers in the front panel. Do not block the louvers on the outside of the air conditioner. NOTE: Your model may differ from the one shown. A. Side curtain against window channelB. Window sash behind top channelC. Bottom channel in behind windowsill Prepare Window for Installation
1. Measure the width of the window opening.
2. Mark the center line on the inside windowsill.
Position Air Conditioner A. Top channelB. 13/32” screwsC. 13/32” screwsD. Side curtainsA. Width of window openingB. Center line Assemble Curtain/Top rail7 NOTE: To make screws easier to drive, drill a pilot hole into the sash through clearance hole in curtains.
3. Expand both curtains to contact the window frame. Install
four wood screws 31/32”. Two in each upper right and left of the curtains.
4. Use three wood screws 31/32” to fix the case to windows
1. Place outer case in window. Lower sash until it rests behind
front flange of top rail. Bottom rail must rest behind window sill.
4. Install left & right installation bracket and as shown in fig.
Install bolt(2 1/2” long flat head bolt and locknut) to the installation bracket and adjust them to proper length ,then use 6 (13/32”)screws to fix the bracket on the case.
5. Use a wood block between the leveling bolts and the wall if
the wall is weak or if the weight of the air conditioner falls between the studs in the wall. Install outer case in window
1. Insert the foam seal behind the top of the lower window sash
and against the glass of the upper window. A. Top of lower window sash B. Foam seal8
1. Plug into a grounded 3 prong outlet.
2. Press RESET on the power supply cord. See “Electrical
2. Place the window lock bracket as shown. Use a ⁄” drill bit to
drill a starter hole through the hole in the window lock bracket and into the upper window.
3. Attach the window lock bracket to the upper window with one
⁄” screw to secure the window in place. Return chassis to the outer case Find someone to help you replace the chassis in outer case. Replace front panel and grille. CAUTION: For security purposes, reinstall screws at cabinet’s sides, removed in step one. IMPORTANT: Because the window sash helps keep the unit in window, make certain the window sash contacts the outer case before reinstalling the chassis.1. Remove the clear plastic film from the control panel.
2. Press POWER to turn on the air conditioner. The Power
indicator light will turn on. NOTE: When the air conditioner is plugged in, the LED display will show “88” for 3 seconds. After the air conditioner is turned on for the first time, the display will show the current room temperature and the fan is set to Low speed.
3. Select mode. See “Mode.”
4. Select fan speed. See “Fan Speed.”
5. Set temperature. See “Temperature.”
1. Press MODE until you see the indicator light glow for the
2. Choose Fan, Cool, Energy Saver or Dehum.
■ Fan—Only the fan runs. Press SPEED to select High, Med or Low fan speed. The display shows the current room temperature. ■ Cool—Cools the room. Press SPEED to select High, Med or Low fan speed. Press the TEMP/TIME up or down arrow button to adjust the temperature. ■ Energy Saver—Fan runs only when cooling is needed. Press SPEED to select High, Med or Low fan speed. Because the fan does not circulate the room air continuously, less energy is used, but the room air is not circulated as often. ■ Dehum—Dries the room. The air conditioner automatically selects the temperature. NOTE: ■ Dehum mode should not be used to cool the room. ■ In Dehum mode,Please do not operate the speed button.
1. Press FAN SPEED until you see the indicator light glow for
the desired setting.
2. Choose High, Med or Low.
■ High—for maximum cooling ■ Med—for normal cooling ■ Low—for minimum cooling Operating your air conditioner properly helps you to obtain the best possible results. This section explains proper air conditioner operation. IMPORTANT: ■ If you turn off the air conditioner, wait at least 3 minutes before turning it back on. This keeps the air conditioner from blowing a fuse or tripping a circuit breaker. ■ Do not try to operate your air conditioner in the Cool mode when outside temperature is below 61°F (16°C). The inside evaporator coil will freeze up, and the air conditioner will not operate properly.
Starting Your Air Conditioner Mode Fan Speed 9■ Press the TEMP/TIME up arrow button to raise the temperature. Each time you press or hold the TEMP/TIME up arrow button, the temperature will go up 1ºF until it reaches 86°F (30°C). NOTE: After 5 seconds, the display will show the current room temperature. ■ Press the TEMP/TIME down arrow button to lower the temperature. Each time you press or hold the TEMP/TIME down arrow button, the temperature will go down 1ºF until it reaches 61°F (16°C). NOTE: After 5 seconds, the display will show the current room temperature. To set the Timer for a 1-hour to 24-hour delay until the air conditioner turns off (the air conditioner must be On):
1. Press TIMER. Timer OFF indicator light will flash. Display will
show remaining hours before the air conditioner will turn off.
2. Press the TEMP/TIME up or down arrow button to change the
delay time from 1 hour to 24 hours.
3. After 5 seconds, Timer OFF indicator light will remain on.
Display will show the current room temperature. To set the Timer to turn on the air conditioner, keeping previous settings:
1. Turn off the air conditioner.
2. Press TIMER. Timer On indicator light will flash. Display will
show remaining hours before the air conditioner will turn on.
3. Press the TEMP/TIME up or down arrow button to change the
delay time from 1 hour to 24 hours.
4. Timer On indicator light will remain on.
To set the Timer to turn on the air conditioner, changing the previous settings:
1. Turn on the air conditioner.
2. Adjust the mode to Fan, Cool, Energy Saver or Dehum.
4. Adjust the temperature between 61ºF and 86ºF (16ºC and
30ºC). NOTE: In Fan mode, the temperature cannot be set.
5. Press TIMER. Timer On indicator light will flash. Display will
show remaining hours before the air conditioner will turn on.
6. Press the TEMP/TIME up or down arrow button to change the
delay time from 1 hour to 24 hours.
7. Timer On indicator light will remain on.
To clear Timer delay program: NOTE: Air conditioner can be either on or off.
1. Press TEMP/TIME once after it has been programmed.
Display will show remaining time.
2. While the display is showing the remaining time, press TIMER
untill Timer indicator light turns off. To see or change the remaining time (in hours): Timer Off :
1. Press TEMP/TIME once after it has been programmed.
Display on the air conditioner control panel will show remaining time.
2. While the display is showing the remaining time, press
the TEMP/TIME up or down arrow button to increase or decrease the time.
3. After 5 seconds, the display on the air conditioner control
panel will show the current room temperature. Timer On :
1. Display on the air conditioner control panel will show
2. While the display is showing the remaining time, press the
TEMP/TIME up or down arrow button to increase or decrease the time. Temperature Timer Delay
To set the Timer for a 1-hour to 24-hour delay before the air conditioner is turned off (the air conditioner must be On):
1. Press TIMER. Timer OFF indicator light on the air conditioner
control panel will flash.
2. Press the TEMP/TIME up or down arrow button to change the
delay time from 1 hour to 24 hours.
3. After 5 seconds, Timer OFF indicator light on the air
conditioner control panel will remain on. To set Timer to turn on the air conditioner, keeping previous settings:
control panel will flash.
3. Press the TEMP/TIME up or down arrow button to change the
delay time from 1 hour to 24 hours.
4. After 5 seconds, Timer On indicator light on the air
conditioner control panel will remain on. To set Timer to turn on the air conditioner, changing the previous settings:
1. Turn on the air conditioner.
2. Adjust the mode to Fan, Cool, Energy Saver or Dehum.
3. For Fan, Cool or Energy Saver mode, adjust the fan speed to
High, Med or Low. NOTE: Remote control may differ in appearance. NOTE: One CR2025 battery (included) powers the remote control. Replace battery after 6 months of use, or when the remote control starts to lose power. Press ON/OFF to turn on the air conditioner. Press MODE to choose Fan, Cool, Energy Saver or Dehum. Press SPEED to choose High, Med or Low. Power Temperature Timer ■ Press the TEMP/TIME up arrow button to raise the temperature. Each time you press or hold the TEMP/TIME up arrow button, the temperature will go up 1ºF until it reaches 86°F (30°C). ■ Press the TEMP/TIME down arrow button to lower the temperature. Each time you press or hold the TEMP/TIME down arrow button, the temperature will go down 1ºF until it reaches 61°F (16°C). Mode Speed Using the Remote ControlA
Your new air conditioner is designed to give you many years of dependable service. This section tells you how to clean and care for your air conditioner properly. The air filter is removable for easy cleaning. A clean filter helps remove dust, lint, and other particles from the air and is important for best cooling and operating efficiency. Check the filter every 2 weeks to see whether it needs cleaning. NOTE: Do not operate the air conditioner without the filter in place.
1. Turn off the air conditioner.
2. Remove the air filter by opening the front panel and removing
the air filter. When your air conditioner is operating normally, you may hear sounds such as: ■ Droplets of water hitting the condenser, causing a pinging or clicking sound. The water droplets help cool the condenser. ■ Air movement from the fan.■ Clicks from the thermostat cycle.■ Vibrations or noise due to poor wall or window construction. ■ A high-pitched hum or pulsating noise caused by the modern high-efficiency compressor cycling on and off. Normal Sounds Cleaning the Air Filter
AIR CONDITIONER CARE
A. Air filterB. Front panel
Changing Air Direction 4-Way Air Flow:The air directional louvers let you control the direction of the airflow to the desired direction.The airflow can be directed up-down,left-right. Vent:The Fresh air vent allows the air conditioner to recirculat inside air,draw fresh air into the room and exhaust stale air to the outside. A. 4-Way Air Flow B. Vent
4. Adjust the temperature between 61ºF and 86ºF (16ºC and
control panel will flash. Display will show remaining hours before the air conditioner will turn on.
6. Press the TEMP/TIME up or down arrow button to change
the delay time from 1 hour to 24 hours.
7. Timer On indicator light on the air conditioner control panel
will remain on. To clear Timer delay program: NOTE: Air conditioner can be either on or off.
1. Press TIMER once after it has been programmed. Display on
the air conditioner control panel will show remaining time.
2. While the display is showing the remaining time, press
TIMER untill Timer indicator light turns off. To see or change the remaining time (in hours): Timer Off :
1. Press TEMP/TIME once after it has been programmed.
Display on the air conditioner control panel will show remaining time.
2. While the display is showing the remaining time, press
the TEMP/TIME up or down arrow button to increase or decrease the time.
3. After 5 seconds, the display on the air conditioner control
panel will show the current room temperature. Timer On :
1. Display on the air conditioner control panel will show
2. While the display is showing the remaining time, press the
TEMP/TIME up or down arrow button to increase or decrease the time.■ The power supply cord has tripped (Reset button has popped out). Press and release RESET (listen for click; Reset button will latch and on some devices, a green light will turn on) to resume operation. ■ A household fuse has blown, or circuit breaker has tripped. Replace the fuse or reset the circuit breaker. If the problem continues, call an electrician. See “Electrical Requirements.” ■ The Power button has not been pressed or the Mode control knob is turned to Off. Press POWER or turn the Mode control knob to an active setting. ■ The local power has failed. Wait for power to be restored. ■ Too many appliances are being used on the same circuit. Unplug or relocate appliances that share the same circuit. ■ Time-delay fuse or circuit breaker of the wrong capacity is being used. Replace with a time-delay fuse or circuit breaker of the correct capacity. See “Electrical Requirements.” Before calling for service, try the suggestions below to see whether you can solve your problem without outside help. Air Conditioner Will Not Operate Air conditioner blows fuses or trips circuit breakers ■ The power supply cord is unplugged. Plug into a grounded 3 prong outlet. See “Electrical Requirements.”
2. Clean the front panel with a soft, damp cloth.
3. Air dry the front panel completely.
4. Turn on the air conditioner.
Your air conditioner needs annual maintenance to help ensure steady, top performance throughout the year. Call your local authorized dealer to schedule an annual checkup. The expense of an annual inspection is your responsibility.
3. Use a vacuum cleaner to clean air filter. If the air filter is very
dirty, wash it in warm water with a mild detergent. Do not wash the air filter in the dishwasher or use any chemical cleaners. Air dry the air filter completely before replacing to ensure maximum efficiency.
4. Replace the air filter.
5. Close the front panel.
6. Turn on the air conditioner.
Cleaning the Front Panel Annual Maintenance Air Conditioner TROUBLE SHOOTING■ Disturbances in your electrical current can trip (Reset button will pop out) the power supply cord. Press and release RESET (listen for click; Reset button will latch and on some devices, a green light will turn on) to resume operation. ■ Electrical overloading, overheating, cord pinching or aging can trip (Reset button will pop out) the power supply cord. After correcting the problem, press and release RESET (listen for click; Reset button will latch and on some devices, a green light will turn on) to resume operation. NOTE: A damaged power supply cord must be replaced with a new power supply cord obtained from the product manufacturer and must not be repaired. ■ The air conditioner is not properly sized for your room. Check the cooling capabilities of your room air conditioner. Room air conditioners are not designed to cool multiple rooms. ■ The filter is dirty or obstructed by debris. Clean the filter. ■ There is excessive heat or moisture (open container cooking, showers, etc.) in the room. Use a fan to exhaust heat or moisture from the room. Try not to use heatproducing appliances during the hottest part of the day. ■ The louvers are blocked. Install the air conditioner in a location where the louvers are free from curtains, blinds, furniture, etc. ■ The outside temperature is below 61°F (16°C). Do not try to operate your air conditioner in the cooling mode when the outside temperature is below 61°F (16°C). ■ The temperature of the room you are trying to cool is extremely hot. Allow extra time for the air conditioner to cool off a very hot room. ■ Windows or doors to the outside are open. Close all windows and doors. ■ The Temperature control is not at a cool enough setting. Adjust the TEMP/TIME control to a cooler setting by pressing the minus button to reduce the temperature. Set the Fan Speed control to the highest setting. ■ The current air conditioner replaced an older model. The use of more efficient components may cause the air conditioner to run longer than an older model, but the total energy consumption will be less. Newer air conditioners do not emit the “blast” of cold air you may be accustomed to from older air conditioners, but this is not an indication of lesser cooling capacity or efficiency. Refer to the efficiency rating (EER) and capacity rating (in Btu/h) marked on the air conditioner. ■ The air conditioner is in a heavily occupied room, or heatproducing appliances are in use in the room. Use exhaust vent fans while cooking or bathing and try not to use heatproducing appliances during the hottest part of the day. A higher capacity air conditioner may be required, depending on the size of the room being cooled. ■ The air conditioner is not properly leveled. The air conditioner should slope slightly downward toward the outside. Level the air conditioner to provide a downward slope toward the outside to ensure proper drainage. See the Installation Instructions. NOTE: Do not drill a hole into the bottom of the metal base and condensate pan. ■ An extension cord is being used. Do not use an extension cord with this or any other appliance. ■ You are trying to restart the air conditioner too soon after turning off the air conditioner. Wait at least 3 minutes after turning off the air conditioner before trying to restart the air conditioner. Air conditioner power supply cord trips (Reset button pops out) Air conditioner cycles on and off too much or does not cool room in cooling mode Air conditioner seems to run too much Water drips from cabinet into your house
14ASSISTANCE OR SERVICE
Before calling for assistance or service, please check“Troubleshooting.” It may save you the cost of a service call. Ifyou still need help, follow the instructions below.When calling, please know the purchase date and the completemodel and serial number of your appliance. This information willhelp us to better respond to your request. If you need replacement parts If you need to order replacement parts, we recommend that youuse only factory-specified replacement parts. Factory-specifiedreplacement parts will fit right and work right because they aremade with the same precision used to build every new appliance.To locate factory-specified replacement parts in your area, callyour nearest designated service center. Please record your model’s information. Whenever you call to request service on your appliance, youneed to know your complete model number and serial number. Visit www.haieramerica.com or call Haier America toll free: 1-877-337-3639. Our consultants provide assistance with: ■ Features and specifications on our appliances.■ Installation information.■ Use and maintenance procedures.■ Repair parts sales.■ Referrals to repair parts distributors, and service companies. Manufacturer-authorized service technicians are trained to fulfill the product warranty and provide after-warranty service, anywhere in the United States.Call Haier America toll free: 1-877-337-3639. Our consultants provide assistance with: ■ Features and specifications on our appliances.■ Installation information.■ Use and maintenance procedures.■ Repair parts sales.■ Referrals to repair parts distributors, and service companies. Manufacturer-authorized service technicians are trained to fulfill the product warranty and provide after-warranty service, anywhere in the Canada. For Further Assistance If you need further assistance, you can write with any questionsor concerns to: Haier America 1356 Broadway New York, NY 10018Please include a daytime phone number in your correspondence. For Further Assistance If you need further assistance, you can write with any questionsor concerns to: Haier America 1356 Broadway New York, NY 10018Please include a daytime phone number in your correspondence.You can find this information on the model and serial numberlabel. See “Electrical Requirements” for the location of the modeland serial number label.Please record the model and serial number information below.Also, record the purchase date of your appliance and the store’sname, address, and telephone number.Model Number________________________________________Serial Number ________________________________________Purchase Date________________________________________Store Name __________________________________________Store Address ________________________________________Store Phone _________________________________________Keep this book and the sales slip together for future reference. In the U.S.A. In Canada
This warranty covers all defects in workmanship or material for the mechanical and electrical parts (including labor costs) contained in this product for a period of 12 months from the date of purchase. For commercial or rental application, the warranty is 90 days. You must keep and be able to provide your original sales receipt as proof of the date of purchase. FIVE YEAR LIMITED WARRANTY ON THE SEALED SYSTEM The sealed system and compressor (hermetic compressor, condenser and evaporator) contained in this product is for a period of 5 years from the date of purchase (excluding labor costs after the initial 12-month period). In commercial or rental use, the additional limited compressor warranty is for 1 year and 9 months (excluding labor costs after the initial 90-day period). You must keep and be able to provide your original sales receipt as proof of the date of purchase.
The original retail purchaser of this product.
Haier America will repair or replace any mechanical, electrical part or the compressor, which proves defective in normal household use for a period of 12 months. Haier America will repair or replace (excluding labor costs) the sealed system and compressor (parts only) for an additional 4-year period.
HOW CAN YOU GET SERVICE
Contact your nearest manufacturer-authorized Service Depot. For the name of the Service Depot nearest you, contact Haier America at 1-877-337-3639. All service must be performed by a manufacturer-authorized Service Depot.
THIS WARRANTY DOES NOT COVER
1. Damages from improper installation.
2. Damages in shipping.
3. Defects other than manufacturing.
4. Damages from misuse, abuse, accident, alteration, lack of proper care and maintenance or incorrect current or voltage.
5. Damage from other than household use.
6. Damages from service by other than an authorized dealer or service center.
7. Decorative trims or replaceable light bulbs.
8. Labor, service, transportation and shipping charges for the removal of defective parts and installation of replacement parts beyond the initial 12-month period. 9. Credit or refund for products over 30 days past date of purchase, or for any loss or injury caused by the product or defects to the product including but not limited to incidental or consequential damages. 10. Food loss for food spoiled as a direct result of mechanical failure of a product or of any delay in providing service, repair or replacement.
11. Refurbished product purchased as/like new or second-hand.
THIS LIMITED WARRANTY IS GIVEN IN LIEU OF ALL OTHE R WARRANTIES, EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. The remedy provided in this warranty is exclusive and is granted in lieu of all other remedies. This warranty does not cover incidental or consequential damages. Some states do not allow the exclusion of incidental or consequential damages, so this limitation may not apply to you. Some states do not allow limitations on how long an implied warranty lasts, so this limitation may not apply to you. This warranty gives you specific legal rights and you may also have other rights which vary from state to state. This warranty covers units within the continental United States, Canada and Puerto Rico.
ManualGo.com