N95 - Respirator mask 3M - Free user manual and instructions
Find the device manual for free N95 3M in PDF.
User questions about N95 3M
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
Download the instructions for your Respirator mask in PDF format for free! Find your manual N95 - 3M and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. N95 by 3M.
USER MANUAL N95 3M
EN Particulate Respirator N95
User Instructions
IMPORTANT: Keep these User Instructions for reference.

This respirator helps protect against certain particles. Misuse may result in sickness or death. For correct use, consult supervisor and these User Instructions, or call 3M in U.S.A., 1-800-247-3941. In Canada, call Technical Service at 1-800-267-4414. In Mexico, call 01-800-712-0646.
IMPORTANT
Before use, wearer must read and understand these User Instructions. Keep these instructions for reference.
Use For
Particles such as those from grinding, sanding, sweeping, sawing, bagging, or processing minerals, coal, iron ore, flour, metal, wood, pollen, and certain other substances. Liquid or non-oil based particles from sprays that do not also emit oil aerosols or vapors. Follow all applicable local regulations. For additional information on 3M use recommendations for this class of respirator please consult the 3M Respirator Selection Guide found on the Personal Safety web site at www.3M.com/respiratorselector or call 1-800-243-4630 in U.S.A. In Canada, call 1-800 267-4414.
Do Not Use For
Do not use for gases and vapors, oil aerosols, asbestos, or sandblasting; particulate concentrations that exceed either 10 times the occupational exposure limit or applicable government regulations, whichever is lower. In the United States, do not use when the U.S. Occupational Safety and Health Administration (OSHA) substance specific standards, such as those for arsenic, cadmium, lead in the construction industry, or 4,4^ -methylene dianiline (MDA), specify other types of respiratory protection. This respirator does not supply oxygen.
Biological Particles
This respirator can help reduce inhalation exposures to certain airborne biological particles (e.g. mold, Bacillus anthracis, Mycobacterium tuberculosis, etc.) but cannot eliminate the risk of contracting infection, illness or disease. OSHA and other government agencies have not established safe exposure limits for these contaminants.
Use Instructions
- Failure to follow all instructions and limitations on the use of this respirator and/or failure to wear this respirator during all times of exposure can reduce respirator effectiveness and may result in sickness or death.
- In the U.S., before occupational use of this respirator, a written respiratory protection program must be implemented meeting all the requirements of OSHA 29 CFR 1910.134, such as training, fit testing, medical evaluation, and applicable OSHA substance specific standards. In Canada, CSA standard Z94.4 requirements must be met and/or requirements of the applicable jurisdiction, as appropriate. Follow all applicable local regulations.
- The particles which can be dangerous to your health include those so small that you cannot see them.
- Leave the contaminated area immediately and contact supervisor if dizziness, irritation, or other distress occurs.
- Store the respirator away from contaminated areas when not in use.
- Inspect respirator before each use to ensure that it is in good operating condition. Examine all the respirator parts for signs of damage including the two headbands, attachment points, nose foam, and noseclip. The respirator should be disposed of immediately upon observation of damaged or missing parts. Filtering facepieces are to be inspected prior to each use to assure there are no holes in the breathing zone other than the punctures around staples and no damage has occurred. Enlarged holes resulting from ripped or torn filter material around staple punctures are considered damage. Immediately replace respirator if damaged. Staple perforations do not affect NIOSH approval (For 8110S only).
- Conduct a user seal check before each use as specified in the Fitting Instructions section. If you cannot achieve a proper seal, do not use the respirator.
- Dispos of used product in accordance with applicable regulations.
Use Limitations
- This respirator does not supply oxygen. Do not use in atmospheres containing less than 19.5% oxygen.
- Do not use when concentrations of contaminants are immediately dangerous to life and health, are unknown or when concentrations exceed 10 times the permissible exposure limit (PEL) or according to specific OSHA standards or applicable government regulations, whichever is lower.
- Do not alter, wash, abuse or misuse this respirator.
- Do not use with beards or other facial hair or other conditions that prevent a good seal between the face and the sealing surface of the respirator.
- Respirators can help protect your lungs against certain airborne contaminants. They will not prevent entry through other routes such as the skin, which would require additional personal protective equipment (PPE).
-
This respirator is designed for occupational/professional use by adults who are properly trained in its use and limitations. This respirator is not designed to be used by children.
-
Individuals with a compromised respiratory system, such as asthma or emphysema, should consult a physician and must complete a medical evaluation prior to use.
- When stored in accordance with temperature and humidity conditions specified below, the product may be used until the "use by" date specified on the packaging.
Storage Conditions and Shelf Life
Before use, store respirators in the original packaging away from contaminated areas, dust, sunlight, extreme temperatures, excessive moisture and damaging chemicals. When stored in accordance with temperature and humidity conditions specified below, the product may be used until the "use by" date specified on packaging. Always inspect product and conduct a user seal check before use as specified in the User Instructions. If you cannot achieve a proper seal, do not use the respirator.

End of Shelf Life
Use respirators before the "use by" date specified on packaging

Storage Temperature Range
-20^(-4^) to +30^(+86^)

Storage Maximum Relative Humidity
<80% RH
Time Use Limitation
If respirator becomes damaged, soiled or breathing becomes difficult, leave the contaminated area immediately and replace the respirator.
Fitting Instructions
Must be followed each time respirator is worn.
- Prestretch top and bottom straps before placing respirator on the face (8210/8210MX only) (Fig. 1).
- Cup the respirator in your hand, with the nosepiece at your fingertips, allowing the headbands to hang freely below your hand (Fig. 2).
- Position the respirator under your chin with the nosepiece up. Pull the top strap over your head resting it high at the top back of your head. Pull the bottom strap over your head and position it around the neck below the ears (Fig. 3).
- Place your fingertips from both hands at the top of the metal nosepiece. Using two hands, mold the nose area to the shape of your nose by pushing inward while moving your fingertips down both sides of the nosepiece (Fig. 4).
Pinching the nosepiece using one hand may result in improper fit and less effective respirator performance. Use two hands.
- Perform a User Seal Check prior to each wearing. To check the respirator-to-face seal, place both hands completely over the respirator and exhale sharply. Be careful not to disturb the position of the respirator. If air leaks around nose, readjust the nosepiece as described in step 4. If air leaks at the respirator edges, work the straps back along the sides of your head (Fig. 5). If you CANNOT achieve a proper seal, DO NOT enter the contaminated area. See your supervisor.





Removal Instructions
See step 3 of Fitting Instructions and cup respirator in hand to maintain position on face. Pull bottom strap over head. Still holding respirator in position, pull top strap over head and remove respirator.
This respirator contains no components made from natural rubber latex.
NIOSH Approved: N95
At least 95% filtration efficiency against solid and liquid aerosols that do not contain oil.



THESE RESPIRATORS ARE APPROVED ONLY IN THE FOLLOWING CONFIGURATIONS:
| RESPIRATOR COMPONENTS | ||||||||
| FILTERING FACEPIECE | ||||||||
| TC-PRO | 1 | 8210 | 8210 PLUS | 8110S | 7048 | 8210MX | 8210 PLUS MX | CAUTIONS AND LIMITATIONS2 |
| 84A-0007 | N95 X X X | X ABCJMNOP | ||||||
| 84A-7762 | N95 X ABCJMNOP | |||||||
| 84A-7835 | N95 X ABCJMNOP | |||||||
1. PROTECTION
N95 - Particulate Filter (95% filter efficiency level) effective against particulate aerosols free of oil; time use restrictions may apply.
2. CAUTIONS AND LIMITATIONS
A - Not for use in atmospheres containing less than 19.5 percent oxygen.
B - Not for use in atmospheres immediately dangerous to life or health.
C - Do not exceed maximum use concentrations established by regulatory standards.
J - Failure to properly use and maintain this product could result in injury or death.
M - All approved respirators shall be selected, fitted, used and maintained in accordance with MSHA, OSHA and other applicable regulations.
N - never substitute, modify, add, or omit parts. Use only exact replacement parts in the configuration as specified by the manufacturer.
O - Refer to User's Instructions, and / or maintenance manuals for information on use and maintenance of these respirators.
P - NIOSH does not evaluate respirators for use as surgical masks.
Rev.F:07-07-17
FOR MORE INFORMATION
In United States, contact:
Website: www.3m.com/workersafety
Technical Assistance: 1-800-243-4630
For other 3M products:
1-800-3M-HELPS or 1-651-737-6501

MISE EN GARDE
Internet: www.3M.ca/Safety
Assistance technique/Technical Assistance: 1800267-4414
Centre communication-client/Customer Care Center : 1 800 364-3577
RENSEIGNEMENTS SUPPLEMENTAIRES
Aux États-Unis :
Internet: www.3m.com/workersafety
Assistance technique: 1800243-4630
THESE RESPIRATORS ARE APPROVED ONLY IN THE FOLLOWING CONFIGURATIONS:
| RESPIRATOR COMPONENTS | ||||||||
| FILTERING FACEPIECE | ||||||||
| TC-PROTECTION | 1 | 8210 | 8210 PLUS | 8110S | 7048 | 8210MX | 8210 PLUS MX | CAUTIONS AND LIMITATIONS2 |
| 84A-0007 | N95 X X X | X ABCJMNOP | ||||||
| 84A-7762 | N95 X ABCCMNOP | |||||||
| 84A-7835 | N95 X ABCCMNOP | |||||||
1. PROTECTION
N95 - Particulate Filter (95% filter efficiency level) effective against particulate aerosols free of oil; time use restrictions may apply.
2. CAUTIONS AND LIMITATIONS
A - Not for use in atmospheres containing less than 19.5 percent oxygen.
B - Not for use in atmospheres immediately dangerous to life or health.
C - Do not exceed maximum use concentrations established by regulatory standards.
J - Failure to properly use and maintain this product could result in injury or death.
M - All approved respirators shall be selected, fitted, used and maintained in accordance with MSHA, OSHA and other applicable regulations.
N - never substitute, modify, add, or omit parts. Use only exact replacement parts in the configuration as specified by the manufacturer.
O - Refer to User's Instructions, and / or maintenance manuals for information on use and maintenance of these respirators.
P - NIOSH does not evaluate respirators for use as surgical masks.
Rev.F:07-07-17
THESE RESPIRATORS ARE APPROVED ONLY IN THE FOLLOWING CONFIGURATIONS:
| RESPIRATOR COMPONENTS | ||||||||
| FILTERING FACEPIECE | ||||||||
| TC-PRO | 1 | 8210 | 8210 PLUS | 8110S | 7048 | 8210MX | 8210 PLUS MX | CAUTIONS AND LIMITATIONS2 |
| 84A-0007 | N95 X X X | X ABCJMNOP | ||||||
| 84A-7762 | N95 X ABCCMNOP | |||||||
| 84A-7835 | N95 X ABCCMNOP | |||||||
1. PROTECTION
N95 - Particulate Filter (95% filter efficiency level) effective against particulate aerosols free of oil; time use restrictions may apply.
2. CAUTIONS AND LIMITATIONS
A - Not for use in atmospheres containing less than 19.5 percent oxygen.
B - Not for use in atmospheres immediately dangerous to life or health.
C - Do not exceed maximum use concentrations established by regulatory standards.
J - Failure to properly use and maintain this product could result in injury or death.
M - All approved respirators shall be selected, fitted, used and maintained in accordance with MSHA, OSHA and other applicable regulations.
N - never substitute, modify, add, or omit parts. Use only exact replacement parts in the configuration as specified by the manufacturer.
O - Refer to User's Instructions, and / or maintenance manuals for information on use and maintenance of these respirators.
P - NIOSH does not evaluate respirators for use as surgical masks.
Rev.F:07-07-17
3M香港有限公司
個人安全產品部
香港屈臣道15號
維多利中心5字樓
(852) 28066111
www.3M.com/hk
PENTING
-20°C (-4°F) to +30°C (+86°F).

Maksimum Kelembapan Relatif Penyimpanan
<80% RH
Had Masa Pengunaan
THESE RESPIRATORS ARE APPROVED ONLY IN THE FOLLOWING CONFIGURATIONS:
| RESPIRATOR COMPONENTS | ||||||||
| FILTERING FACEPIECE | ||||||||
| TC-PROTECTION | 1 | 8210 | 8210 PLUS | 8110S | 7048 | 8210MX | 8210 PLUS MX | CAUTIONS AND LIMITATIONS2 |
| 84A-0007 | N95 X X X | X ABCJMNOP | ||||||
| 84A-7762 | N95 X ABCCMNOP | |||||||
| 84A-7835 | N95 X ABCCMNOP | |||||||
1. PROTECTION
N95 - Particulate Filter (95% filter efficiency level) effective against particulate aerosols free of oil; time use restrictions may apply.
2. CAUTIONS AND LIMITATIONS
A - Not for use in atmospheres containing less than 19.5 percent oxygen.
B - Not for use in atmospheres immediately dangerous to life or health.
C - Do not exceed maximum use concentrations established by regulatory standards.
J - Failure to properly use and maintain this product could result in injury or death.
M - All approved respirators shall be selected, fitted, used and maintained in accordance with MSHA, OSHA and other applicable regulations.
N - never substitute, modify, add, or omit parts. Use only exact replacement parts in the configuration as specified by the manufacturer.
O - Refer to User's Instructions, and / or maintenance manuals for information on use and maintenance of these respirators.
P - NIOSH does not evaluate respirators for use as surgical masks.
Rev.F:07-07-17
UNTUK MAKLUMAT LANJUT
Di Malaysia, sila hubungi
Laman web: www.3M.com.my/safety
Bantuan Teknikal: 603-7884 2888
3M PERSONAL SAFETY DIVISION
3M CENTER, BUILDING 0235-02-W-70
ST.PAUL, MN 55144-1000
3M is a trademark of 3M Company, used under license in Canada.
3M PSD products for occupational use only.
3M PERSONAL SAFETY DIVISION
3M CANADA COMPANY
P.O. BOX 5757 LONDON, ONTARIO N6A 4T1
3M is a trademark of 3M Company, used under license in Canada.
DIVISION DES PRODUITS DE PROTECTION INDIVIDUELLE DE 3M
C.P.5757
LONDON (ONTARIO) N6A 4T1
3M MEXICO S.A. DE C.V.
AV.SANTA FE NO.190
COL. SANTA FE, DEL. ALVARO OBREGON
MEXICO D.F. 01210
NO.2, JALAN PJU 1A/7A,
ARA DAMANSARA,
47301 PETALING JAYA.
SELANGOR, MALAYSIA