ME03CE1 - Server GIGABYTE - Free user manual and instructions
Find the device manual for free ME03CE1 GIGABYTE in PDF.
User questions about ME03CE1 GIGABYTE
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
Download the instructions for your Server in PDF format for free! Find your manual ME03CE1 - GIGABYTE and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. ME03CE1 by GIGABYTE.
USER MANUAL ME03CE1 GIGABYTE
© 2023 Giga Computing Technology CO., LTD. All rights reserved.
The trademarks mentioned in this manual are legally registered to their respective owners.
Disclaimer
Information in this manual is protected by copyright laws and is the property of Giga Computing. Changes to the specifications and features in this manual may be made by Giga Computing without prior notice. No part of this manual may be reproduced, copied, translated, transmitted, or published in any form or by any means without Giga Computing's prior written permission.
Documentation Classifications
In order to assist in the use of this product, Giga Computing provides the following types of documentation:
■ User Manual: detailed information & steps about the installation, configuration and use of this product (e.g. motherboard, server barebones), covering hardware and BIOS.
■ User Guide: detailed information about the installation & use of an add-on hardware or software component (e.g. BMC firmware, rail-kit) compatible with this product.
■ Quick Installation Guide: a short guide with visual diagrams that you can reference easily for installation purposes of this product (e.g. motherboard, server barebones).
Please see the support section of the online product page to check the current availability of these documents.
For More Information
For related product specifications, the latest firmware and software, and other information please visit our website at http://www.gigabyte.com/Enterprise
For GIGABYTE distributors and resellers, additional sales & marketing materials are available from our reseller portal: http://reseller.b2b.gigabyte.com
For further technical assistance, please contact your GIGABYTE representative or visit https://esupport.gigabyte.com/ to create a new support ticket
For any general sales or marketing enquiries, you may also message GIGABYTE server directly by email: server.grp@gigabyte.com
Table of Contents
ME03-CE0/ME03-CE1 Motherboard Layout 5
Block Diagram 7
Chapter 1 Hardware Installation .8
1-1 Installation Precautions 8
1-2 Product Specifications 9
1-3 Installing and Removing the CPU 12
1-4 Installing and Removing Memory 13
1-4-1 Six-Channel Memory Configuration 13
1-4-2 Installing and Removing a Memory Module 14
1-4-3 DIMM Population Table 15
1-4-4 Processor and Memory Module Matrix Table 15
1-5 Installing the M.2 SSD Module 16
1-6 Back Panel Connectors 17
1-7 Internal Connectors 19
1-8 Jumper Settings 27
Chapter 2 BIOS Setup 28
2-1 The Main Menu 30
2-2 Advanced Menu 33
2-2-1 Trusted Computing 36
2-2-2 PSP Firmware Versions. 37
2-2-3 Legacy Video Select 38
2-2-4 AST2600 Super IO Configuration 39
2-2-5 S5 RTC Wake Settings. 41
2-2-6 UEFI Variables Protection 42
2-2-7 Serial Port Console Redirect 43
2-2-8 CPU Configuration 47
2-2-9 SIO Common Setting. 48
2-2-10 PCI Subsystem Settings. 49
2-2-11 USB Configuration 51
2-2-12 Network Stack Configuration 53
2-2-13 NVMe Configuration 54
2-2-14 SATA Configuration 55
2-2-15 Graphic Output Configuration. 56
2-2-16 AMD Mem Configuration Status 57
2-2-17 TIs Auth Configuration 58
2-2-18 RAM Disk Configuration 59
2-2-19 iSCSI Configuration 60
2-2-20 Broadcom BCM57416 NetXtreme-E 10GBASE-T RDMA Ethernet. 61
2-2-21 Broadcom NetXtreme BCM5720 Gigabit Ethernet 64
2-2-22 VLAN Configuration 69
2-2-23 MAC IPv4 Network Configuration 70
2-2-24 MAC IPv6 Network Configuration 71
2-3 AMD CBS Menu 72
2-3-1 CPU Common Options 73
2-3-2 DF Common Options. 79
2-3-3 UMC Common Options 87
2-3-4 NBIO Common Options 108
2-3-5 FCH Common Options 119
2-3-6 SOC Miscellaneous Control 128
2-3-7 Workload Tuning. 130
2-3-8 CXL Common Options. 131
2-4 AMD PBS Menu 132
2-4-1 RAS 133
2-5 Chipset Setup Menu. 135
2-5-1 North Bridge 136
2-5-2 Fabric Resource 137
2-6 Server Management Menu. 139
2-6-1 System Event Log 141
2-6-2 View FRU Information 142
2-6-3 BMC Network Configuration 143
2-6-4 IPv6 BMC Network Configuration 144
2-7 Security Menu 145
2-7-1 Secure Boot 146
2-8 Boot Menu. 148
2-9 Save & Exit Menu 150
2-10BIOSRecovery 151
2-11 BIOS POST Beep code (AMI standard) 152
2-11-1 PEI Beep Codes 152
2-11-2 DXE Beep Codes 152

ME03-CE0/ME03-CE1 Motherboard Layout
Item Code Description
1 LED_BMC BMC Firmware Readiness LED
2 SPI_TPM1 TPM Connector
3 CN_NCSI1 NCSI Connector
4 P12V_CPU2 2x4 Pin 12V Power Connector
5 USB3_MLAN Sever Management LAN Port (Top)/USB 3.2 Gen1 Ports (Bottom)
6 LAN1 10GbE LAN Port #1 (ME03-CE0)/1GbE LAN Port #1 (ME03-CE1)
7 LAN2 10GbE LAN Port #2 (ME03-CE0)/1GbE LAN Port #2 (ME03-CE1)
8 COM1_VGA Serial Port (Top)/VGA Port (Bottom)
9 SW_ID2 ID Button with LED
10 CPU0_FAN CPU Fan Connector
11ATX 2x12Pin Main Power Connector
12 PMBUS1 PMBus Connector
13 U2_P0_G3A0 MCIO Connector
14 U2_P0_G3A1 MCIO Connector
15 P12V_CPU1 2x4 Pin 12V Power Connector
16 U2_P0_G3B0 MCIO Connector
17 FP_1 Front Panel Header
18 M2_0 M.2 Slot (PCIe Gen3 x4, Support NGFF-2280/22110)
19 BAT Battery Socket
20 SYS_FAN4 System Fan Connector #4
21 SYS_FAN5 System Fan Connector #5
22 SYS_FAN2 System Fan Connector #2
23 F_USB3_1 Front Panel USB 3.2 Gen1 Connector
24BP_1 HDDBackplaneBoardConnector
25 SYS_FAN3 System Fan Connector #3
26 SYS_FAN1 System Fan Connector #1
27 IPMB1 IPMB Connector
28 CASE_OPEN Case Open Intrusion Alert Header
29 PCIE_1 PCIe x16 Slot #1 (Gen4 x16)
30 PCIE_2 PCIe x16 Slot #2 (Gen4 x8)
31 PCIE_3 PCIe x16 Slot #3 (Gen4 x16)
32PCIE_4 PCIex16Slot#4(Gen5x16)
33 PCIE_5 PCIe x16 Slot #5 (Gen5 x16)
34PCIE_6 PCIex16Slot#6(Gen5x16)
Block Diagram

ME03-CEO Block Diagram
ME03-CE1 Block Diagram

Chapter 1 Hardware Installation
1-1 Installation Precautions
The motherboard contains numerous delicate electronic circuits and components which can become damaged as a result of electrostatic discharge (ESD). Prior to installation, carefully read the user's manual and follow these procedures:
- Prior to installation, do not remove or break motherboard S/N (Serial Number) sticker or warranty sticker provided by your dealer. These stickers are required for warranty validation.
- Always remove the AC power by unplugging the power cord from the power outlet before installing or removing the motherboard or other hardware components.
- When connecting hardware components to the internal connectors on the motherboard, make sure they are connected tightly and securely.
- When handling the motherboard, avoid touching any metal leads or connectors.
- It is best to wear an electrostatic discharge (ESD) wrist strap when handling electronic components such as a motherboard, CPU or memory. If you do not have an ESD wrist strap, keep your hands dry and first touch a metal object to eliminate static electricity.
- Prior to installing the motherboard, please have it on top of an antistatic pad or within an electrostatic shielding container.
- Before unplugging the power supply cable from the motherboard, make sure the power supply has been turned off.
- Before turning on the power, make sure the power supply voltage has been set according to the local voltage standard.
- Before using the product, please verify that all cables and power connectors of your hardware components are connected.
- To prevent damage to the motherboard, do not allow screws to come in contact with the motherboard circuit or its components.
- Make sure there are no leftover screws or metal components placed on the motherboard or within the computer casing.
- Do not place the computer system on an uneven surface.
- Do not place the computer system in a high-temperature environment.
- Turning on the computer power during the installation process can lead to damage to system components as well as physical harm to the user.
- If you are uncertain about any installation steps or have a problem related to the use of the product, please consult a certified computer technician.
- To avoid any potential short circuit of the DIMM slots, please remove any stand-offs from the chassis that will be located underneath the DIMM slots, before installing the motherboard into the chassis.
1-2 Product Specifications

NOTE:
We reserve the right to make any changes to the product specifications and product-related information without prior notice.
| Form Factor | ATX 304.8W x 254D (mm) |
| CPU | AMD EPYCTM 8004 series processors Single processor, 5nm technology Up to 64-core, 128 threads per processor cTDP up to 225W |
| Socket | 1 x LGA 4844 Socket SP6 |
| Chipset | System on Chip |
| Memory | 12 x DIMM slots DDR5 memory supported only 6-Channel memory architecture RDIMM modules up to 96GB supported Memory speed: Up to 4800 MHz (1DPC), 3600 MHz (2DPC) |
| LAN ME03-CE0: | 2 x 10Gb/s BASE-T LAN ports (1 x Broadcom® BCM57416) NCSI function supported ME03-CE1: 2 x 1Gb/s BASE-T LAN ports (1 x Broadcom® BCM5720) NCSI function supported 1 x 10/100/1000 management LAN |
| Onboard Graphics | Integrated in Aspeed® AST2600 2D Video Graphic Adapter with PCIe bus interface 1920x1200@60Hz 32bpp, DDR4 SDRAM |
| Storage Interface | 3 x MCIO 4i for 12 x SATA |
| RAID | N/A |
| Expansion Slots | Slot_6: 1 x PCIe x16 (Gen5 x16 bus) slot Slot_5: 1 x PCIe x16 (Gen5 x16 bus) slot Slot_4: 1 x PCIe x16 (Gen5 x16 bus) slot Slot_3: 1 x PCIe x16 (Gen4 x16 bus) slot Slot_2: 1 x PCIe x16 (Gen4 x8 bus) slot Slot_1: 1 x PCIe x16 (Gen4 x16 or x8 bus) slot, shared with Slot_2 1 x M.2 slot: - M-key - PCIe Gen3 x4 - Supports 2280/22110 cards 3 x MCIO 4i connectors for 3 x Gen5 NVMe or 12 x SATA |
| Internal I/O Connectors | 1 x 24-pin ATX main power connector 2 x 8-pin ATX 12V power connectors 3 x MCIO 4i connectors 1 x M.2 slot 1 x CPU fan header 5 x System fan headers 2 x USB 3.2 Gen1 headers 1 x TPM header 1 x Front panel header 1 x Backplane board header 1 x PMBus connector 1 x IPMB connector 1 x Clear CMOS jumper 1 x BIOS recovery jumper |
| Rear I/O Connectors | 2 x USB 3.2 Gen1 1 x VGA 1 x COM 2 x RJ45 1 x VLAN 1 x ID button with LED |
| TPM | 1 x TPM Header with SPI Interface Optional TPM2.0 kit: CTM010 |
| Board Management | ◆Aspeed® AST2600 Management Controller ◆GIGABYTE Management Console (AMI MegaRAC SP-X) Web Interface ◆ Dashboard ◆ HTML5 KVM ◆ Sensor Monitor (Voltage, RPM, Temperature, CPU Status ...etc.) ◆ Sensor Reading History Data ◆ FRU Information ◆ SEL Log in Linear Storage / Circular Storage Policy ◆ Hardware Inventory ◆ Fan Profile ◆ System Firewall ◆ Power Consumption ◆ Power Control ◆ LDAP / AD / RADIUS Support ◆ Backup & Restore Configuration ◆ Remote BIOS/BMC/CPLD Update ◆ Event Log Filter ◆ User Management ◆ Media Redirection Settings ◆ PAM Order Settings ◆ SSL Settings ◆ SMTP Settings |
| Operating Properties | ◆ Operating temperature: 10°C to 40°C ◆ Operating humidity: 8-80% (non-condensing) ◆ Non-operating temperature: -40°C to 60°C ◆ Non-operating humidity: 20%-95% (non-condensing) |
1-3 Installing and Removing the CPU

Read the following guidelines before you begin to install the CPU:
- Make sure that the motherboard supports the CPU.
- Always turn off the computer and unplug the power cord from the power outlet before installing the CPU to prevent hardware damage.
- Unplug all cables from the power outlets.
- Disconnect all telecommunication cables from their ports.
- Place the system unit on a flat and stable surface.
- Open the system according to the instructions.

WARNING!
Failure to properly turn off the server before you start installing components may cause serious damage. Do not attempt the procedures described in the following sections unless you are a qualified service technician.
Follow these instructions to install the CPU:
- Loosen the three captive screws securing the CPU cover in sequential order (1 2 3
- Flip open the CPU cover.
- Remove the CPU carrier from the CPU frame using the handle on the CPU carrier.
- Using the handle on the CPU carrier insert the new CPU carrier with CPU installed into the CPU frame.
NOTE: Ensure the CPU is installed in the CPU carrier in the correct orientation, with the triangle on the CPU aligned to the top left corner of the CPU carrier.
- Flip the CPU frame with CPU installed into place in the CPU socket.
- Flip the CPU cover into place over the CPU socket.
- Tighten the CPU cover screws in sequential order (1 2 3 ) to secure the CPU cover in place.







- Tighten the CPU cover screws, use T-20 6-Lobe driver to tighten 3 captive nuts in sequence as 1-3. The screw tightening torque: 13.8 ± 1.3 kgf-cm.
- The illustrations of the heat-sink installation shown are for reference only.
1-4 Installing and Removing Memory

Read the following guidelines before you begin to install the memory:
- Make sure that the motherboard supports the memory. It is recommended to use memory of the same capacity, brand, speed, and chips.
- Always turn off the computer and unplug the power cord from the power outlet before installing the memory to prevent hardware damage.
- Memory modules have a foolproof design. A memory module can be installed in only one direction. If you are unable to insert the memory, switch the direction.
1-4-1 Six-Channel Memory Configuration
This motherboard provides 12 DDR5 memory slots and supports Six-Channel Technology. After the memory is installed, the BIOS will automatically detect the specifications and capacity of the memory.

1-4-2 Installing and Removing a Memory Module

Before installing a memory module, make sure to turn off the computer and unplug the power cord from the power outlet to prevent damage to the memory module.
Be sure to install DDR5 DIMMs on this motherboard.
Make sure your DIMM slots have a single latch or a double latch.
Follow these instructions to install a DIMM module with Single Latch :
- Open the plastic latch of the memory slot, then place the memory module as pre-inserted vertically position.

- Hold it with both hands, insert the memory module into the movable end first, and then insert the memory module into the fixed end.

- Then use both hands to insert the memory module vertically into the DIMM slot and push it down. Close the plastic latch at the edge of the DIMM slots to lock the memory module.

- Reverse the installation steps when you want to remove the memory module.
Follow these instructions to install a DIMM module with Double Latch:
- Insert the DIMM memory module vertically into the DIMM slot and push it down.
- Close the plastic clip at both edges of the DIMM slots to lock the DIMM module.
- Reverse the installation steps when you want to remove the DIMM module.

1-4-3 DIMM Population Table
| DIMM Type | DIMM Population DDR5 Frequency (MT/s) | ||
| DIMM 0 DIMM | 1 | 14-layer 77mil PCB stackup | |
| RDIMM | -- 1R 4800 | ||
| 1R 1R 4000 | |||
| -- 2R 4800 | |||
| 2R 2R 3600 | |||
1-4-4 Processor and Memory Module Matrix Table
| Memory Q'ty | CPU0 | |||||||||||
| D1 | D0 | B1 | B0 | A1 | A0 | E0 | E1 | F0 | F1 | H0 | H1 | |
| 1 DIMM | V | |||||||||||
| 2 DIMM | V | V | ||||||||||
| 4 DIMM | V | V | V | V | ||||||||
| 6 DIMM | V | V | V | V | V | V | ||||||
| 8 DIMM | V | V | V | V | V | V | V | V | ||||
| 12 DIMM | V | V | V | V | V | V | V | V | V | V | V | V |
1-5 Installing the M.2 SSD Module

WARNING:
Installation of the thermal pad over the M.2 device is required when installing an M.2 device. Lack of the thermal pad may result in the system overheating and throttle the system performance.

CAUTION
The position of the stand-off screw will depend on the size of the M.2 device. The stand-off screw is pre-installed for 22110 cards as standard. Refer to the size of the M.2 device and change the position of the stand-off screw accordingly.
Follow these instructions to install the M.2 device and heat sink:
- Insert the M.2 device into the M.2 connector.
- Press down on the M.2 device.
- Install the thermal pad of the M.2 device to the M.2 device.
- Press down on the thermal pad.
- Secure the M.2 device and its thermal pad to the motherboard with a single screw.
- Reverse steps 1-5 to remove the M.2 device.

1-6 Back Panel Connectors

ID button with LED
When the system identification is active, the ID LED on the front/ back panel glows blue.
Serial Port
Connect to serial-based mouse or data processing devices.
VGA Port
Connect to a monitor device.
10GbE LAN Port #2 (ME03-CE0)
The Gigabit Ethernet LAN port provides Internet connection at up to 10 Gbps data rate. See the section below for a description of the states of the LAN port LEDs.
1GbELANPort#2(ME03-CE1)
The Gigabit Ethernet LAN port provides Internet connection at up to 1 Gbps data rate. See the section below for a description of the states of the LAN port LEDs.
10GbE LAN Port #1 (ME03-CE0)
The Gigabit Ethernet LAN port provides Internet connection at up to 10 Gbps data rate. See the section below for a description of the states of the LAN port LEDs.
1GbELANPort#1(ME03-CE1)
The Gigabit Ethernet LAN port provides Internet connection at up to 1 Gbps data rate. See the section below for a description of the states of the LAN port LEDs.
Server Management LAN Port
The LAN port provides Internet connection with data transfer speeds of 10/100/1000Mbps. This port is the dedicated LAN port for Server Management.
USB 3.2 Gen1 Ports
The USB port supports the USB 3.2 specification. Use this port for USB devices such as a USB keyboard/mouse, USB printer, USB flash drive etc.
LAN and ID Button LEDs
Speed LED Link/Activity LED

LAN Port
10Gb LAN LED:
| State Description |
| Yellow On 5Gbps, 2.5Gbps, 1Gps data rate |
| Green On 10Gbps data rate |
| Off 100Mbps data rate |
10/100/1000 LAN LED:
| State Description |
| Yellow On 1Gbps data rate |
| Green On 100Mbps data rate |
| Off 10Mbps data rate |
ID button/LED:
| State Description |
| Blue On System identification is active |
| Off System identification is disabled |

- When removing the cable connected to a back panel connector, first remove the cable from your device and then remove it from the motherboard.
- When removing the cable, pull it straight out from the connector. Do not rock it side to side to prevent an electrical short inside the cable connector.
1-7 Internal Connectors

Read the following guidelines before connecting external devices:
- First make sure your devices are compliant with the connectors you wish to connect.
- Before installing the devices, be sure to turn off the devices and your computer. Unplug the power cord from the power outlet to prevent damage to the devices.
- After installing the device and before turning on the computer, make sure the device cable has been securely attached to the connector on the motherboard.
1/2/3)ATX1/P12V_CPU1/P12V_CPU2
(2x12 Main Power Connector and 2x4 12V Power Connector)
With the use of the power connector, the power supply can supply enough stable power to all the components on the motherboard. Before connecting the power connector, first make sure the power supply is turned off and all devices are properly installed. The power connector possesses a foolproof design. Connect the power supply cable to the power connector in the correct orientation. The 12V power connector mainly supplies power to the CPU. If the 12V power connector is not connected, the computer will not start.

To meet expansion requirements, it is recommended that a power supply that can withstand high power consumption be used (500W or greater). If a power supply is used that does not provide the required power, the result can lead to an unstable or unbootable system.

ATX

P12V_CPU1/P12V_CPU2
| Pin No. Definition Pin | No. Definition |
| 1 3.3V 13 3.3V | |
| 2 3.3V 14 -12V | |
| 3 GND 15 GND | |
| 4 +5V 16 PS_ON | |
| 5 GND 17 GND | |
| 6 +5V 18 GND | |
| 7 GND 19 GND | |
| 8 Power Good 20 NA | |
| 9 5V\$B 21 +5V | |
| 10 +12V | 22 +5V |
| 11 +12V | 23 +5V |
| 12 3.3V 24 GND |


| Pin No. | Definition |
| 1 | GND |
| 2 | GND |
| 3 | GND |
| 4 | GND |
| 5 | +12V |
| 6 | +12V |
| 7 | +12V |
| 8 | +12V |
4/5/6) CPU0_FAN/SYS_FAN1/SYS_FAN2/SYS_FAN3/SYS_FAN4/SYS_FAN5 (Fan Headers)
The motherboard has one 4-pin CPU fan header (CPU_FAN), and five 4-pin (SYS_FAN) system fan headers. Most fan headers possess a foolproof insertion design. When connecting a fan cable, be sure to connect it in the correct orientation (the black connector wire is the ground wire). The motherboard supports CPU fan speed control, which requires the use of a CPU fan with fan speed control design. For optimum heat dissipation, it is recommended that a system fan be installed inside the chassis.


| Pin No. | Definition |
| 1 | GND |
| 2 | +12V |
| 3 | Sense |
| 4 Speed Control | |

- Be sure to connect fan cables to the fan headers to prevent your CPU and system from overheating. Overheating may result in damage to the CPU or the system may hang.
These fan headers are not configuration jumper blocks. Do not place a jumper cap on the headers.
7) PMBUS1 (PMBus Connector)
The Power Management Bus (PMBus) is a variant of the System Management Bus (SMBus) which is targeted at digital management of power supplies.


| Pin No. | Definition |
| 1 PMBus Clock | |
| 2 PMBus Data | |
| 3 PMBus Alert | |
| 4 | GND |
| 5 3.3V | Sense |
8) F_USB3_1 (Front Panel USB 3.2 Gen1 Connector)
The connector/ header conform to USB 3.2 specification. Each USB connector/ header can provide two USB ports via an optional USB bracket. For purchasing the optional USB bracket, please contact the local dealer.


| Pin No. | Definition | Pin No | Definition |
| 1 | Power 11 IntA_P2_D+ | ||
| 2 | IntA_P1_SSRX- 12 IntA_P2_D- | ||
| 3 | IntA_P1_SSRX+ 13 GND | ||
| 4 | GND 14 IntA_P2_SSTX+ | ||
| 5 | IntA_P1_SSTX- 15 IntA_P2_SSTX- | ||
| 6 | IntA_P1_SSTX+ 16 GND | ||
| 7 | GND 17 IntA_P2_SSRX+ | ||
| 8 | IntA_P1_D- 18 IntA_P2_SSRX- | ||
| 9 | IntA_P1_D+ 19 Power | ||
| 10 | NC | 20 | No Pin |
9) FP_1 (Front Panel Header)
Connect the power switch, reset switch, speaker, chassis intrusion switch/sensor and system status indicator on the chassis to this header according to the pin assignments below. Note the positive and negative pins before connecting the cables.


| Pin No. | Definition | Pin No. | Definition |
| 1 | Power LED+ | 2 | 5V Standby |
| 3 | No Pin | 4 | ID LED+ |
| 5 | Power LED- | 6 | ID LED- |
| 7 | HDD LED+ | 8 | System Status LED+ |
| 9 | HDD LED- | 10 | System Status LED - |
| 11 | Power Button | 12 | LAN1 Active LED+ |
| 13 | GND | 14 | LAN1 Link LED- |
| 15 | Reset Button | 16 | SMBus Data |
| 17 | GND | 18 | SMBus Clock |
| 19 | ID Button | 20 | Case Open |
| 21 | GND | 22 | LAN2 Active LED+ |
| 23 | NMI Switch | 24 LAN2 Link LED- | |

The front panel design may differ by chassis. A front panel module mainly consists of power switch, reset switch, power LED, hard drive activity LED, speaker etc. When connecting your chassis front panel module to this header, make sure the wire assignments and the pin assignments are matched correctly.
10) BP_1 (HDD Backplane Board Connector)


| Pin No. | Definition | Pin No. | Definition |
| 1 | Reserved 2 | BPMI DIN/OUT | |
| 3 | GND 4 | BPMI DOUT/IN | |
| 5 | BPMI_LOAD 6 | GND | |
| 7 | BPMI_CLK 8 | PLD_Program_EN | |
| 9 | GLED_AMB_N | 10 GLED_SRN_N | |
| 11 | FAN_IRQ_N | 12 Reserved | |
| 13 | BP_SCL | 14 GND | |
| 15 | BP_SDA | 16 BP_RST_N | |
| 17 | SMB_U2_TEMP_SCL | 18 GND | |
| 19 | SMB_U2_TEMP_SDA | 20 I2C_DEV_RST | |
| 21 | PH_HP_SCL0 | 22 GND | |
| 23 | PH_HP_SDA0 | 24 GND | |
| 25 | Reserved | 26 GND | |
| 27 | Reserved | 28 GND | |
| 29 | P3/V3 AUX | 30 P3V3 AUX |
11) SPI_TPM1 (Trusted Platform Module Connector)
Trusted Platform Module (TPM) is an international standard for a secure cryptoprocessor, a dedicated microcontroller designed to secure hardware through integrated cryptographic keys.



| Pin No. | Definition | Pin No. | Definition |
| 1 | Clock | 8 | NC |
| 2 | P_3V3_AUX | 9 | NC |
| 3 | LPC_RST 10 No Pin | ||
| 4 | NC | 11 | NC |
| 5 | SPI_MISO 12 GND | ||
| 6 | IRQ_SPI | 13 | SPI_C$_N |
| 7 | SPI_MOSI 14 GND |
12) IPMB1 (Intelligent Platform Management Bus) Connector
The Intelligent Platform Management Bus Communications Protocol defines a byte-level transport for transferring Intelligent Platform Management Interface Specification (IPMI) messages between intelligent I2C devices.


| Pin No. | Definition |
| 1 | Clock |
| 2 | GND |
| 3 | Data |
| 4 | VCC |
13) CN_NCSI1 (NCSI Connector)


| Pin No. | Definition | Pin No. | Definition |
| 1 | NCSI_CLK 2 GND | ||
| 3 | NCSI_RX_D0 4 GND | ||
| 5 | NCSI_RX_D1 6 GND | ||
| 7 | NCSI_CRS_DV 8 GND | ||
| 9 | NCSI_RX_ER 10 GND | ||
| 11 | P3V3_AUX 12 GND | ||
| 13 | NCSI_TX_D1 14 GND | ||
| 15 | NCSI_TX_D0 16 GND | ||
| 17 | NCSI_TX_EN | 18 GND | |
| 19 | NCSI_PRESENT 20 | P3V3_AUX |
14) LED_BMC (BMC Firmware Readiness LED)

| State Description | |
| On BMC firmware is initial | |
| Blink BMC firmware is ready | |
| Off AC loss | |
15) BAT (Battery Socket)
The battery provides power to keep the values (such as BIOS configurations, date, and time information) in the CMOS when the computer is turned off. Replace the battery when the battery voltage drops to a low level, or the CMOS values may not be accurate or may be lost.



- Always turn off your computer and unplug the power cord before replacing the battery.
- Replace the battery with an equivalent one. Danger of explosion if the battery is replaced with an incorrect model.
- Contact the place of purchase or local dealer if you are not able to replace the battery by yourself or uncertain about the battery model.
- Used batteries must be handled in accordance with local environmental regulations.
16) CASE_OPEN (Case Open Intrusion Alert Header)
This motherboard provides a chassis detection feature that detects if the chassis cover has been removed. This function requires a chassis with chassis intrusion detection design.

Open: Normal Operation (Default)
Closed: Active Chassis Intrusion Alert
1-8 Jumper Settings

Chapter 2 BIOS Setup
BIOS (Basic Input and Output System) records hardware parameters of the system in the EFI on the motherboard. Its major functions include conducting the Power-On Self-Test (POST) during system startup, saving system parameters, loading the operating system etc. The BIOS includes a BIOS Setup program that allows the user to modify basic system configuration settings or to activate certain system features. When the power is turned off, the battery on the motherboard supplies the necessary power to the CMOS to keep the configuration values in the CMOS.
To access the BIOS Setup program, press the key during the POST when the power is turned on.

BIOS flashing is potentially risky, if you do not encounter any problems when using the current BIOS version, it is recommended that you don't flash the BIOS. To flash the BIOS, do it with caution. Inadequate BIOS flashing may result in system malfunction.
- It is recommended that you not alter the default settings (unless you need to) to prevent system instability or other unexpected results. Inadequately altering the settings may result in system's failure to boot. If this occurs, try to clear the CMOS values and reset the board to default values. (Refer to the Exit section in this chapter or introductions of the battery/clearing CMOS jumper in Chapter 1 for how to clear the CMOS values.)
BIOS Setup Program Function Keys
| <←><→> Move the selection bar to select the screen | |
| <↑><↓> Move the selection bar to select an item | |
| <++> Increase the numeric value or make changes | |
| <-> Decrease the numeric value or make changes | |
| <Enter> Execute command or enter the submenu | |
| <Esc> Main Menu: Exit the BIOS Setup program | |
| Submenus: Exit current submenu | |
| <F1> Show descriptions of general help | |
| <F3> Restore the previous BIOS settings for the current submenus | |
| <F9> Load the Optimized BIOS default settings for the current submenus | |
| <F10> Save all the changes and exit the BIOS Setup program | |
Main
This setup page includes all the items of the standard compatible BIOS.
Advanced
This setup page includes all the items of AMI BIOS special enhanced features.
(ex: Auto detect fan and temperature status, automatically configure hard disk parameters.)
■ AMD CBS
This setup page includes the common items for configuration of AMD motherboard-related information.
AMD PBS Option
This setup page includes the common items for configuration of AMD CPM RAS related settings.
Chipset
This setup page includes all the submenu options for configuring the functions of the North Bridge.
Server Management
Server additional features enabled/disabled setup menus.
Security
Change, set, or disable supervisor and user password. Configuration supervisor password allows you to restrict access to the system and BIOS Setup.
A supervisor password allows you to make changes in BIOS Setup.
A user password only allows you to view the BIOS settings but not to make changes.
Boot
This setup page provides items for configuration of the boot sequence.
Save & Exit
Save all the changes made in the BIOS Setup program to the CMOS and exit BIOS Setup. (Pressing <F10> can also carry out this task.)
Abandon all changes and the previous settings remain in effect. Pressing Y to the confirmation message will exit BIOS Setup. (Pressing Esc can also carry out this task.)
2-1 The Main Menu
Once you enter the BIOS Setup program, the Main Menu (as shown below) appears on the screen. Use arrow keys to move among the items and press
Main Menu Help
The on-screen description of a highlighted setup option is displayed on the bottom line of the Main Menu.
Submenu Help
While in a submenu, press

- When the system is not stable as usual, select the Restore Defaults item to set your system to its defaults.
- The BIOS Setup menus described in this chapter are for reference only and may differ by BIOS version.


| Parameter | Description |
| BIOS Information | |
| Project Name | Displays the project name information. |
| Project Version | Displays version number of the BIOS setup utility. |
| Build Date and Time | Displays the date and time when the BIOS setup utility was created. |
| BMC Information(Note1) | |
| BMC Firmware Version(Note1) | Displays BMC firmware version information. |
| Processor Information | |
| CPU Brand String/ CPU Speed / Processor Core / Microcode Patch | Displays the technical specifications for the installed processor(s). |
| Total Memory(Note2) | Displays the total memory size of the installed memory. |
| Memory Speed(Note2) | Displays the frequency information of the installed memory. |
| VR Information Version Displays VR version information. | |
| AGESA PI Version | |
| PI Version Displays AGESA PI version information. | |
(Note1) Functions available on selected models.
(Note2) This section will display capacity and frequency information of the memory that the customer has installed.
| Parameter | Description |
| Onboard LAN Information | |
| LAN1 MAC Address (Note) | Displays LAN MAC address information. |
| LAN2 MAC Address (Note) | Displays LAN MAC address information. |
| System Date | Sets the date following the weekday-month-day-year format. |
| System Time | Sets the system time following the hour-minute-second format. |
2-2 Advanced Menu
The Advanced Menu displays submenu options for configuring the function of various hardware components. Select a submenu item, then press
When Boot Mode Select is set to UEFI (Default)
ME03-CEO




When "Boot Mode Select" is set to Legacy in the Boot > Boot Mode Select section

2-2-1 Trusted Computing

| Parameter | Description |
| Configuration | |
| Security Device Support | Enable/Disable BIOS support for security device. OS will not show security device. TCG EFI protocol and INT1A interface will not be available. Options available: Disable, Enable. Default setting is Enable. |
2-2-2 PSP Firmware Versions
The PSP Firmware Versions page displays the basic PSP firmware version information. Items on this window are non-configurable.

2-2-3 Legacy Video Select

| Parameter | Description |
| OnBrd/Ext VGA Select | Selects between onboard or external VGA support. Options available: Auto, Onboard, External. Default setting is Auto. |
(Note) This configurable option will be displayed when "Boot Mode Select" is set to Legacy in the Boot > Boot Mode Select section.
2-2-4 AST2600 Super IO Configuration

| Parameter | Description |
| AST2600 Super IO Configuration | |
| Super IO Chip Displays the super IO chip information | |
| Serial Port 1Configuration | Press [Enter] for configuration of advanced items. |
2-2-4-1 Serial Port 1 Configuration

| Parameter | Description |
| Serial Port 1 Configuration | |
| Serial Port (Note) | Enable/Disable the Serial Port (COM). When set to Enabled allows you to configure the Serial port 1 settings. When set to Disabled, displays no configuration for the serial port. Options available: Disabled, Enabled. Default setting is Enabled. |
| Devices Settings Displays the Serial Port 1 device settings. | |
| Change Settings | Select an optimal settings for Super IO Device. Options available for Serial Port 1: Auto IO=3F8h; IRQ=4; IO=3F8h; IRQ=3, 4, 5, 6, 7, 9, 10, 11, 12; IO=2F8h; IRQ=3, 4, 5, 6, 7, 9, 10, 11, 12; IO=3E8h; IRQ=3, 4, 5, 6, 7, 9, 10, 11, 12; IO=2E8h; IRQ=3, 4, 5, 6, 7, 9, 10, 11, 12; Default setting is Auto. |
(Note) Advanced items prompt when this item is defined.
2-2-5 S5 RTC Wake Settings

| Parameter | Description |
| Wake System from S5 | Enable/Disable system wake on alarm event. Options available: Disabled, Fixed Time, Dynamic Time. When Fixed Time is selected, system will wake on the hr:min:sec specified. Default setting is Disabled. |
2-2-6 UEFI Variables Protection

| Parameter | Description |
| Password protection of Runtime Variables | Control the NVRAM Runtime Variable protection through System Admin Password. Options available: Enable, Disable. Default setting is Enable. |
2-2-7 Serial Port Console Redirection

| Parameter | Description |
| COM0 Console Redirection(Note) | Select whether to enable console redirection for specified device. Console redirection enables the users to manage the system from a remote location. Options available: Enabled, Disabled. Default setting is Disabled. |
| COM0 Console Redirection Settings | Press [Enter] to configure advanced items. Please note that this item is configurable when COM0 Console Redirection is set to Enabled. • Terminal Type - Selects a terminal type to be used for console redirection. - Options available: VT100, VT100Plus, ANSI, VT-UTF8. Default setting is ANSI. • Bits per second - Selects the transfer rate for console redirection. - Options available: 9600, 19200, 38400, 57600, 115200. Default setting is 115200. • Data Bits - Selects the number of data bits used for console redirection. - Options available: 7, 8. Default setting is 8. |
(Note) Advanced items prompt when this item is defined.
| Parameter | Description |
| COM0 Console Redirection Settings (continued) | • Parity - A parity bit can be sent with the data bits to detect some transmission errors. - Even: parity bit is 0 if the num of 1's in the data bits is even. - Odd: parity bit is 0 if num of 1's in the data bits is odd. - Mark: parity bit is always 1. Space: Parity bit is always 0. - Mark and Space Parity do not allow for error detection. - Options available: None, Even, Odd, Mark, Space. Default setting is None. • Stop Bits - Stop bits indicate the end of a serial data packet. (A start bit indicates the beginning). The standard setting is 1 stop bit. Communication with slow devices may require more than 1 stop bit. - Options available: 1, 2. Default setting is 1. • Flow Control - Flow control can prevent data loss from buffer overflow. When sending data, if the receiving buffers are full, a 'stop' signal can be sent to stop the data flow. Once the buffers are empty, a 'start' signal can be sent to re-start the flow. Hardware flow control uses two wires to send start/stop signals. - Options available: None, Hardware RTS/CTS. Default setting is None. • VT-UTF8 Combo Key Support - Enable/Disable the VT-UTF8 Combo Key Support. - Options available: Enabled, Disabled. Default setting is Enabled. • Recorder Mode - When this mode enabled, only texts will be send. This is to capture Terminal data. - Options available: Enabled, Disabled. Default setting is Disabled. • Resolution 100x31 - Enable/Disable extended terminal resolution. - Options available: Enabled, Disabled. Default setting is Enabled. • Putty KeyPad - Selects Function Key and KeyPad on Putty. - Options available: VT100, LINUX, XTERM6, SC0, ESCN, VT400. Default setting is VT100. |
| Legacy Console Redirector | |
| Legacy Console Redirector Settings | Press [Enter] to configure advanced items. • Redirection COM Port - Selects a COM port for Legacy serial redirection. - Default setting is COM0. • Resolution - Selects the number of rows and columns used in Console Redirector for legacy OS support. - Options available: 80x24, 80x25. Default setting is 80x24. • Redirect After POST - When Bootloader is selected, then Legacy Console Redirector is disabled before booting to legacy OS. When Always Enable is selected, then Legacy Console Redirector is enabled for legacy OS. - Options available: Always Enable, BootLoader. Default setting is Always Enable. |
| Serial Port for Out-of-Band Management / Windows Emergency Management Services (EMS) Console Redirector (Note) | EMS console redirection allows the user to configure Console Redirector Settings to support Out-of-Band Serial Port management. Options available: Disabled, Enabled. Default setting is Disabled. |
| Serial Port for Out-of-Band EMS Console Redirector Settings | Press [Enter] to configure advanced items. Please note that this item is configurable when Serial Port for Out-of- Band Management EMS Console Redirector is set to Enabled. • Out-of-Band Mgmt Port - Microsoft Windows Emergency Management Service (EMS) allows for remote management of a Windows Server OS through a serial port. - Default setting is COM0. • Terminal Type - Selects a terminal type to be used for console redirection. - Options available: VT100, VT100Plus, ANSI, VT-UTF8. Default setting is ANSI. • Bits per second - Selects the transfer rate for console redirection. - Options available: 9600, 19200, 57600, 115200. Default setting is 115200. |
(Note) Advanced items prompt when this item is defined.
| Parameter | Description |
| Serial Port for Out-of-Band EMS Console Redirection Settings(continued) | • Flow Control - Flow control can prevent data loss from buffer overflow. When sending data, if the receiving buffers are full, a 'stop' signal can be sent to stop the data flow. Once the buffers are empty, a 'start' signal can be sent to re-start the flow. Hardware flow control uses two wires to send start/stop signals. - Options available: None, Hardware RTS/CTS, Software Xon/Xoff. Default setting is None. |
2-2-8 CPU Configuration

| Parameter | Description |
| SVM Mode | Enable/Disable the CPU Virtualization. Options available: Disabled, Enabled. Default setting is Enabled. |
| CPU 0 Information | Press [Enter] to view the memory information related to CPU 0. |
2-2-9 SIO Common Setting

| Parameter | Description |
| Lock Legacy Resources | Options available: Disabled, Enabled. Default setting is Disabled. |
2-2-10 PCI Subsystem Settings


| Parameter | Description |
| PCI Bus Driver Version | Displays the PCI Bus Driver version information. |
| PCIE #(Note1) | Change the PCIe lanes. |
| SLOT #(Note1) | Options available: Disabled, Auto, x16, x8x8, x8x4x4, x4x4x8, x4x4x4x4. Default setting is Auto. |
| PCIE #(I/O ROM)(Note1) | When enabled, this setting will initialize the device expansion ROM for the related PCI-E slot. |
| SLOT #(I/O ROM)(Note1) | Options available: Disabled, Enabled. Default setting is Enabled. |
| PCIE #(Link Speed)(Note1) | Configure PCIe max link speed. |
| SLOT #(Link Speed)(Note1) | Options available: Auto, Gen4, Gen3, Gen2, Gen1. Default setting is Auto. |
| MCIO P0_G3 (Note2) | Change MCIO P0_G3 PCIe lanes. |
| Options available: Disabled, Auto, SATA, x4x4x4. Default setting is Auto. | |
| MCIO P0_G3 I/O ROM (Note2) | When enabled, this setting will initialize the device expansion ROM for the related devices. |
| Options available: Disabled, Enabled. Default setting is Enabled. | |
| MCIO P0_G3 Link Speed (Note2) | Configure MCIO PCIe max link speed. |
| Options available: Auto, Gen4, Gen3, Gen2, Gen1. Default setting is Auto. | |
| Onboard LAN Controller (Note3) | Enable/Disable the onboard LAN devices. |
| Options available: Disabled, Enabled. Default setting is Enabled. | |
| Onboard LAN# I/O ROM (Note3) | Enable/Disable the onboard LAN devices, and initializes device expansion ROM. |
| Options available: Disabled, Enabled. Default setting is Enabled. | |
| PCI Devices Common Settings | |
| Above 4G Decoding | Enable/Disable memory mapped I/O to 4GB or greater address space (Above 4G Decoding). |
| Options available: Disabled, Enabled. Default setting is Enabled. | |
| SR-IOV Support | If the system has SR-IOV capable PCIe devices, this item Enable/ Disable Single Root IO Virtualization Support. |
| Options available: Disabled, Enabled. Default setting is Enabled. | |
| Relaxed Ordering | Enable/Disable PCI express device relaxed ordering. |
| Options available: Disabled, Enabled. Default setting is Enabled. |
(Note1) This section is dependent on the available PCIe Slot.
(Note2) This section is dependent on the available MCIO connector.
(Note3) This section is dependent on the available LAN controller.
2-2-11 USB Configuration

| Parameter | Description |
| USB Configuration | |
| USB Module Version | Displays the USB module version information. |
| USB Controllers | Displays the supported USB controllers. |
| USB Devices: | Displays the USB devices connected to the system. |
| Legacy USB Support | Enable/Disable the Legacy USB support function. AUTO option disables legacy support if no USB devices are connected. DISABLE option will keep USB devices available only for EFI applications. Options available: Enabled, Disabled, Auto. Default setting is Enabled. |
| XHCI Hand-off | Enable/Disable the XHCI Hand-off support. Options available: Enabled, Disabled. Default setting is Enabled. |
| USB Mass Storage Driver Support (Note) | Enable/Disable the USB Mass Storage Driver Support. Options available: Disabled, Enabled. Default setting is Enabled. |
| Port 60/64 Emulation | Enable I/O port 60h/64h emulation support. This should be enabled for the complete USB Keyboard Legacy support for non-USB aware OS. Options available: Enabled/Disabled. Default setting is Enabled. |
| USB hardware delays and time-outs |
(Note) This item is present only if you attach USB devices.
| Parameter | Description |
| USB transfer time-out | Selects the time-out value for USB Control/Bulk/Interrupt transfers. Options available: 1 sec, 5 sec, 10 sec, 20 sec. Default setting is 20 sec. |
| Device reset time-out | Selects the time-out value during a USB mass storage device reset. Options available: 10 sec, 20 sec, 30 sec, 40 sec. Default setting is 20 sec. |
| Device power-up delay | Maximum time the device will take before it properly reports itself to the Host Controller. "Auto" uses default value: for a Root port it is 100 ms, for a Hub port the delay is taken from Hub descriptor. Options available: Auto, Manual. Default setting is Auto. |
2-2-12 Network Stack Configuration

| Parameter | Description |
| Network Stack | Enable/Disable the UEFI network stack. Options available: Enabled, Disabled. Default setting is Enabled. |
| Ipv4 PXE Support (Note) | Enable/Disable the Ipv4 PXE feature. Options available: Enabled, Disabled. Default setting is Enabled. |
| Ipv4 HTTP Support (Note) | Enable/Disable the Ipv4 HTTP feature. Options available: Enabled, Disabled. Default setting is Disabled. |
| Ipv6 PXE Support (Note) | Enable/Disable the Ipv6 PXE feature. Options available: Enabled, Disabled. Default setting is Enabled. |
| Ipv6 HTTP Support (Note) | Enable/Disable the Ipv6 HTTP feature. Options available: Enabled, Disabled. Default setting is Disabled. |
| PXE boot wait time (Note) | Wait time in seconds to press ESC key to abort the PXE boot. Press the <+> / <-> keys to increase or decrease the desired values. |
| Media detect count (Note) | Number of times the presence of media will be checked. Press the <+> / <-> keys to increase or decrease the desired values. |
(Note) This item appears when Network Stack is set to Enabled.
2-2-13 NVMe Configuration

| Parameter | Description |
| NVMe Configuration | Displays the NVMe devices connected to the system. |
2-2-14 SATA Configuration

| Parameter | Description |
| SATA Configuration | Displays the installed HDD devices information. System will automatically detect HDD type. |
2-2-15 Graphic Output Configuration

| Parameter | Description |
| Output Device Type | Selects output device type. Options available: First loaded Device, Onboard Device, External Device, Specific Device. Default setting is Onboard Device. |
2-2-16 AMD Mem Configuration Status

| Parameter | Description |
| CPU 0 | Press [Enter] to view the memory configuration status related to CPU 0. |
2-2-17 TIs Auth Configuration

| Parameter Description | |
| Server CA Configuration | Press [Enter] for configuration of advanced items. Enroll Cert - Press [Enter] to enroll a certificate Enroll Cert Using File Cert GUID Input digit character in 1111111-2222-3333-4444-1234567890ab format. - Commit Changes and Exit - Discard Changes and Exit Delete Cert |
| Client Cert Configuration | Press [Enter] for configuration of advanced items. |
2-2-18 RAM Disk Configuration

| Parameter | Description |
| Disk Memory Type | Specifies the type of memory to use from available memory pool in system to create a disk. Options available: Boot Service Data, Reserved. Default setting is Boot Service Data. |
| Create Raw | Creates a raw RAM disk. • Size (Hex) - Input a valid RAM disk size that should be multiple of the RAM disk block size. • Create & Exit • Discard & Exit |
| Create from file | Creates a RAM disk from a given file. |
| Created RAM disk list | |
| Remove selected RAM disk(s) | Selects the RAM disk(s) to remove. |
2-2-19 iSCSI Configuration

| Parameter | Description |
| iSCSI Initiator Name | Press [Enter] and name iSCSI Initiator. Only IQN format is accepted. Range: from 4 to 223 |
| Add an Attempt | Press [Enter] to configure advanced items. |
| Delete Attempts | Press [Enter] to configure advanced items. |
| Change Attempt Order | Press [Enter] to configure advanced items. |
2-2-20 Broadcom BCM57416 NetXtreme-E 10GBASE-T RDMA Ethernet

| Parameter Description | |
| Firmware Image Menu | Press [Enter] to view firmware image information. |
| Press [Enter] to configure advanced items. • Multi-Function Mode - Configures the NIC Hardware Mode. - Options available: SF, NPAR 1.0. Default setting is SF. • SR-IOV - Enable/Disable Single Root I/O Virtualization. - Options available: Disabled, Enabled. Default setting is Disabled. • Number of MSI-X Vectors per VF - Configures the number of MSI-X Vectors per VF (0-128). - Default setting is 16. | |
| Device Configuration Menu | • Maximum Number of PF MSI-X Vectors - Configures the maximum number of PF MSI-X Vectors (0-512 per controller). - Default setting is 74. • Energy Efficient Ethernet - Enable/Disable Energy Efficient Ethernet operation. - Options available: Disabled, Enabled. Default setting is Disabled. • Operational Link Speed - Configures the link speed setting to be used as the default link speed for the selected port. - Options available: AutoNeg. Default setting is AutoNeg. |
| Parameter | Description |
| Device Configuration Menu(continued) | Support RDMA- Enable/Disable RDMA support for this port.- Options available: Disabled, Enabled. Default setting is Disabled.DCB Protocol- Enable/Disable DCB protocol.- Options available: Disabled, Enabled (IEEE only), CEE (only), Both (IEEE preferred with fallback to CEE). Default setting is Disabled.LLDP nearest bridge- Enable/Disable LLDP nearest bridge state.- Options available: Disabled, Enabled. Default setting is Enabled. Default EVB Mode- Configures the default Edge Virtual Bridging mode.- Options available: VEB, VEPA, None. Default setting is VEB.Enable PME Capability- Enable/Disable PME Capability support.- Options available: Disabled, Enabled. Default setting is Enabled-flow Offload- Options available: Enabled, Disabled. Default setting is Disabled.Live Firmware Upgrade- Options available: Enabled, Disabled. Default setting is Disabled.Adapter Error Recovery- Options available: Enabled, Disabled. Default setting is Disabled. |
| MBA Configuration Menu | Press [Enter] to configure advanced items.Option ROM- Enable/Disable Boot Option ROM.- Options available: Disabled, Enabled. Default setting is Enabled.Legacy Boot Protocol- Selects non-UEFI Boot Protocol: Preboot Execution Environment (PXE)/iSCSI.- Options available: PXE, iSCSI, NONE. Default setting is PXEBOOT Strap Type- Selects the boot strap type. Options available: Auto Detect, BBS, Int 18h, Int 19h. Default setting is Auto Detect.Hide Setup Prompt- Configures whether the Setup Prompt is displayed during ROM initialization.- Options available: Disabled, Enabled. Default setting is Disabled.Setup Key Stroke- Configures key strokes to invoke the configuration menu.- Options available: Ctrl-S, Ctrl-B. Default setting is Ctrl-S.Banner Message Timeout- Selects the timeout value. (0 defaults to 4 seconds, 15 is no delay, 1-14 is timeout value in seconds)- Default setting is 5. |
| Parameter Description | |
| MBA Configuration Menu (continued) | Pre-boot Wake On LAN - Configures Pre-boot Wake on LAN (WOL). - Options available: Disabled, Enabled. Default setting is Enabled. VLAN Mode - Configures the virtual LAN (VLAN) mode. - Options available: Disabled, Enabled. Default setting is Disabled. VLAN ID - Configures the VLAN ID (1...4094). - This item is available only when VLAN Mode is Enabled. Boot Retry Count - Selects the number of boot retries. - Options available: No Retry, 1 Retry, 2 Retries, 3 Retries, 4 Retries, 5 Retries, 6 Retries, Indefinite Retries. Default setting is No Retry. |
| Blink LEDs | Identifies the physical network port by blinking the associated LED. Press the numeric keys to adjust desired values. |
| Link Status | Specifies the link status of the port. |
| Physical Link Speed | Displays the technical specifications for the Network Interface Controller. |
| Chip Type | Displays the technical specifications for the Network Interface Controller. |
| PCI Device ID | Displays the technical specifications for the Network Interface Controller. |
| Bus:Device:Function | Displays the technical specifications for the Network Interface Controller. |
| Permanent MAC Address | Displays the MAC address of the Ethernet controller. |
| Virtual MAC Address | Displays the virtual MAC address of the Ethernet controller. |
| Restore Defaults | Reset the adapter to factory defaults. |
2-2-21 Broadcom NetXtreme BCM5720 Gigabit Ethernet

| Parameter Description | |
| Firmware Image Menu | Press [Enter] to view firmware image information. |
| Press [Enter] to configure advanced items. • Legacy Boot Protocol - Selects non-UEFI Boot Protocol: Preboot Execution Environment (PXE)/iSCSI. - Options available: PXE, iSCSI, NONE. Default setting is PXE. • Boot Strap Type - Selects the boot strap type. Options available: Auto Detect, BBS, Int 18h, Int 19h. Default setting is Auto Detect. | |
| MBA Configuration Menu | Hide Setup Prompt - Configures whether the Setup Prompt is displayed during ROM initialization. - Options available: Disabled, Enabled. Default setting is Disabled. • Setup Key Stroke - Configures key strokes to invoke the configuration menu. - Options available: Ctrl-S, Ctrl-B. Default setting is Ctrl-S. • Banner Message Timeout - Selects the timeout value. (0 defaults to 4 seconds, 15 is no delay, 1-14 is timeout value in seconds) - Default setting is 5. |
Parameter Description
| MBA Configuration Menu (continued) | • Link Speed - Configures link speed. - Options available: AutoNeg, 10Mbps Half, 10Mbps Full, 100Mbps Half, 100Mbps Full. Default setting is AutoNeg. • Pre-boot Wake On LAN - Configures Pre-boot Wake on LAN (WOL). - Options available: Disabled, Enabled. Default setting is Enabled. • VLAN Mode - Configures the virtual LAN (VLAN) mode. - Options available: Disabled, Enabled. Default setting is Disabled. • VLAN ID - Configures the VLAN ID (1...4094). - This item is available only when VLAN Mode is Enabled. |
| iSCSI Boot Configuration Menu | Press [Enter] to configure advanced items. |
| Blink LEDs | Identifies the physical network port by blinking the associated LED. Press the numeric keys to adjust desired values. |
| Chip Type | Displays the technical specifications for the Network Interface Controller. |
| PCI Device ID | Displays the technical specifications for the Network Interface Controller. |
| Bus:Device:Function | Displays the technical specifications for the Network Interface Controller. |
| Link Status | Specifies the link status of the port. |
| Permanent MAC Address | Displays the MAC address of the Ethernet controller. |
| Virtual MAC Address | Displays the virtual MAC address of the Ethernet controller. |
2-2-21-1 iSCSI Boot Configuration Menu

Parameter Description
| iSCSI General Parameters | Press [Enter] to configure advanced items. |
| • TCP/IP Parameters via DHCP | |
| - Acquires TCP/IP Parameters via DHCP. | |
| - Options available: Disabled, Enabled. Default setting is Enabled. | |
| • IP Autoconfiguration | |
| - Auto-configures the IP configuration. | |
| • iSCSI Parameters via DHCP | |
| - Acquires iSCSI Parameters via DHCP. | |
| - Options available: Disabled, Enabled. Default setting is Disabled. | |
| • CHAP Authentication | |
| - Enable/Disable the CHAP authentication. | |
| - Options available: Disabled, Enabled. Default setting is Disabled. | |
| • Boot to iSCSI Target | |
| - Enable/Disable booting to iSCSI target after log-on. | |
| - Options available:Disabled, Enabled, One Time Disabled. Default setting is Enabled. | |
| • DHCP Vendor ID | |
| - Configures the DHCP vendor ID (up to 32 characters long). | |
| • Link Up Delay Time | |
| - Configures the link up delay time in seconds (0-225). | |
| Parameter | Description |
| iSCSI General Parameters(continued) | Use TCP Timestamp- Enable/Disable the TCP timestamp.- Options available: Disabled, Enabled. Default setting is Disabled.Target as First HDD- Enable/Disable target appears as first hard disk drive (HDD) in the system.- Options available: Disabled, Enabled. Default setting is Disabled.LUN Busy Retry Count- Configures the number of retries in 2 second intervals when LUN is busy (0-60).- Default setting is 0.IP Version- Displays the IP version supported. Modifying this parameter will reset all IP-related fields.- Options available: IPv4, IPv6. Disabled. Default setting is IPv4. |
| iSCSI Initiator Parameters | Press [Enter] to configure advanced items.IP Address- Configures the initiator IP address.Subnet Mask- Configures the IP subnet mask.Default Gateway- Configures the default gateway IP address.Primary DNS- Configures the primary DNS IP address.Secondary DNS- Configures the secondary DNS IP address.iSCSI Name- Configures the iSCSI name.CHAP ID- Configures the Challenge-Handshake Authentication Protocol(CHAP) ID (up to 128 characters in length).CHAP Secret- Configure the Challenge-Handshake Authentication Protocol(CHAP) Secret (12 to 16 characters in length). |
| iSCSI First/Second Target Parameters | Press [Enter] to configure advanced items Connect- Enable/Disable the target establishment.- Options available: Disabled, Enabled. Default setting is Disabled.IP Address- Configures the Target IP address.TCP Port- Configures the Target TCP port number (1-65535). |
| iSCSI First/Second Target Parameters (continued) | • Boot LUN - Configures the Target boot LUN number (0-255). • iSCSI Name - Configures the iSCSI name. |
| • CHAP ID - Configures the Challenge-Handshake Authentication Protocol (CHAP) ID (up to 128 characters in length). | |
| • CHAP Secret - Configure the Challenge-Handshake Authentication Protocol (CHAP) Secret (12 to 16 characters in length). | |
| Secondary Device | Press [Enter] to configure advanced items. |
| • Secondary Device - Inputs the secondary device MAC address. | |
| • Use Independent Target Portal - Use Independent target portal when multipath I/O is enabled. - Options available: Disabled, Enabled. Default setting is Disabled. | |
| • Use Independent Target Name - Use Independent target name when multipath I/O is enabled. - Options available: Disabled, Enabled. Default setting is Disabled. |
2-2-22 VLAN Configuration

| Parameter | Description |
| Enter Configuration Menu | Press [Enter] to configure advanced items.Create new VLANVLAN ID- Sets VLAN ID for a new VLAN or an existing VLAN.- Press the <+> / <-> keys to increase or decrease the desired values.- The valid range is from 0 to 4094.Priority- Sets 802.1Q Priority for a new VLAN or an existing VLAN.- Press the <+> / <-> keys to increase or decrease the desired values.- The valid range is from 0 to 7.Add VLAN- Press [Enter] to create a new VLAN or update an existing VLAN.Configured VLAN ListRemove VLAN- Press [Enter] to remove an existing VLAN. |
2-2-23 MAC IPv4 Network Configuration

| Parameter Description | |
| Configured | Indicates whether network address is configured successfully or not. Options available: Enabled, Disabled. Default setting is Disabled. |
| Enable DHCP(Note) | Options available: Enabled, Disabled. Default setting is Disabled. |
| Local IP Address(Note) | Press [Enter] to configure local IP address. |
| Local NetMask(Note) | Press [Enter] to configure local NetMask. |
| Local Gateway(Note) | Press [Enter] to configure local Gateway |
| Local DNS Servers(Note) | Press [Enter] to configure local DNS servers |
| Save Changes and Exit Press [Enter] to save all configurations. | |
(Note) This item appears when Configured is set to Enabled.
2-2-24 MAC IPv6 Network Configuration

| Parameter | Description |
| Enter Configuration Menu | Press [Enter] to configure advanced items. |
| • Displays the MAC Address information. | |
| • Interface ID | |
| - The 64 bit alternative interface ID for the device. The string is colon separated. e.g. ff:dd:88:66:cc:1:2:3. | |
| • DAD Transmit Count | |
| - The number of consecutive Neighbor solicitation messages sent while performing Duplicate Address Detection on a tentative address. A value of zero indicates that Duplicate Address Detection is not performed. | |
| • Policy | |
| - Options available: automatic, manual. Default setting is automatic. | |
| • Save Changes and Exit | |
| - Press [Enter] to save all configurations. |
2-3 AMD CBS Menu
AMD CBS menu displays submenu options for configuring the CPU-related information that the BIOS automatically sets. Select asubmenu item, then press [Enter] to access the relatedsubmenu screen.

2-3-1 CPU Common Options


| Parameter Description | |
| CPU Common Options | |
| Performance Press [Enter] for configuration of advanced items. | |
| REP-MOV/STOS Streaming | Allow REP-MOV/STOS to use non-caching streaming stores for large sizes. Options available: Disabled, Enabled. Default setting is Enabled. |
| Prefetcher settings Press [Enter] for configuration of advanced items. | |
| Core Watchdog Press [Enter] for configuration of advanced items. | |
| RedirectForReturnDis | From a workaround for GCC/C000005 issue for XV Core on CZ A0, setting MSRC001_1029 Decode Configuration (DE_CFG) bit 14 [DecfgNoRrectForReturns] to 1. Options available: Auto, 1, 0. Default setting is Auto. |
| Platform First Error Handling | Enable/Disable PFEH, cloak individual banks, and mask deferred error interrupts from each bank. Options available: Enabled, Disabled, Auto. Default setting is Auto. |
| Core Performance Boost | Enable/Disable the Core Performance Boost function. Options available: Disabled, Auto. Default setting is Auto. |
| Global C-state Control | Controls the IO based C-state generation and DF C-states. Options available: Disabled, Enabled, Auto. Default setting is Auto. |
| Power Supply Idle Control | Configs the Power Supply Idle Control. Options available: Low Current Idle, Typical Current Idle, Auto. Default setting is Auto. |
| SEV-ES ASID Space Limit | Configs the Space limit for SEV-ES ASIDs. Default setting is 1. |
| SEV Control | Enable/Disable SEV control. Options available: Enabled, Disable. Default setting is Enable. |
| Streaming Stores Control | Enable/Disable the Streaming Stores functionality. Options available: Disabled, Enabled, Auto. Default setting is Auto. |
| Local APIC Mode | Sets the Local APIC Mode. Options available: Compatibility, xAPIC, x2APIC, Auto. Default setting is Auto. |
| ACPI_CST C1 Declaration | Determines whether or not to declare the C1 state to the OS.. Options available: Disabled, Enabled, Auto. Default setting is Auto. |
| ACPI CST C2 Latency Enter in microseconds (decimal value). | |
| MCA error thresh enable | Enable MCA error thresholding. Options available: False, True, Auto. Default setting is True. |
| MCA FruText | Enable MCA FruText. Options available: False, True. Default setting is True. |
| SMU and PSP Debug Mode | When this option is enabled, specific uncorrected errors detected by the PSP FW or SMU FW will hand and not reset the system. Options available: Disabled, Enabled, Auto. Default setting is Auto. |
| PPIN Opt-in | Enable/Disable the PPIN feature. Options available: Disabled, Enabled, Auto. Default setting is Auto. |
| SNP Memory (RMP Table) Coverage | Enabled: Enter system memory is covered. Options available: Disabled, Enabled, Custom, Auto. Default setting is Auto. |
| SMEE | Controls the Secure Memory Encryption Enable (SMEE) function. Options available: Disable, Enable, Auto. Default setting is Auto. |
| Action on BIST Failure | Action to take when a CCD BIST failure is detected. Options available: Do nothing, Down-CCD, Auto. Default setting is Auto. |
| Fast Short REP MOVSB (FSRM) | Options available: Disabled, Enabled, Auto. Default setting is Auto. |
| Enhanced REP MOVSB/ STOSB (ERMSB) | Options available: Disabled, Enabled, Auto. Default setting is Auto. |
| Log Transparent Errors | Enable/Disable the log Transparent errors function. Options available: Auto, Disabled, Enabled. Default setting is Auto. |
| AVX512 | Enable/Disable AVX512. Options available: Disabled, Enabled, Auto. Default setting is Auto. |
| MONITOR and MWAIT disable | The MONITOR, MWAIT, MONITORX and MWAITX opcodes become invalid when enabled. Options available: Enabled, Disabled, Auto. Default setting is Auto |
| Small Hammer Configuration | Options available: Disabled, Enabled, Auto. Default setting is Auto. |
| Corrector Branch Predictor Options available: Disable, Enable. Default setting is Disable. | |
| PAUSE Delay | Number a cycles thread will be idle after a PAUSE instruction. Options available: Auto, Disable, 16 cycles, 32 cycles, 64 cycles, 128 cycles. Default setting is Auto. |
| CPU Speculative Store Modes | Select the CPU speculative store modes. Options available: Balanced, More Speculative, Less Speculative, Auto. Default setting is Auto. |
| Prefetch/Request Throttle | Enables XI logic which calculates average latency, updates throttle level, and sends throttle level messages to L2. Options available: Disable, Enable, Auto. Default setting is Auto. |
2-3-1-1 Performance

| Parameter Description | |
| Performance | |
| OC Mode(Note) | Options available: Normal Operation, Customized. Default setting is Normal Operation. |
| Custom Core Pstates | Allows you to accept or decline enabling Custom Core Pstates. When accepted, you can disable or customize core pstates. |
| CCD/Core/Thread Enablement | Allows you to accept or decline enabling CCDs, processor cores and threads. When accepted, you can control the number of CCDs to be used, and the number of cores to be used. • CCD Control - Options available: Auto, 2 CCDs. Default setting is Auto. • Core Control - Options available: Auto, TWO(1+1), FOUR(2+2), SIX(3+3), EIGHT(4+4), TEN(5+5), TWELVE(6+6), FOURTEEN(7+7). - Default setting is Auto. |
| SMT Control | Can be used to disable symmetric multithreading. To re-enable SMT, a POWER CYCLE is needed after select the 'Enable' option. Select 'Auto' base on BIOS PCD. (PcdAmdSmtMode) default setting. Options available: Disable, Enable, Auto. Default setting is Enable. |
(Note) Advanced items are configurable when this item is defined.
2-3-1-2 Prefetcher Settings

| Parameter Description | |
| Prefetcher settings | |
| L1 Stream HW Prefetcher | Enable/Disable L1 Stream HW Prefetcher. Options available: Disable, Enable, Auto. Default setting is Auto. |
| L1 Stride Prefetcher | Use memory access history of individual instructions to fetch additional lines when each access is a constant distance from the previous. Enable/Disable L1 Stride Prefetcher. Options available: Disable, Enable, Auto. Default setting is Auto. |
| L1 Region Prefetcher | Use memory access history to fetch additional lines when the data access for a given instruction tends to be followed by other data accesses. Enable/Disable L1 Region Prefetcher. Options available: Disable, Enable, Auto. Default setting is Auto. |
| L2 Stream HW Prefetcher | Enable/Disable L2 Stream HW Prefetcher. Options available: Disable, Enable, Auto. Default setting is Auto. |
| L2 Up/Down Prefetcher | Use memory access history to determine whether to fetch the next or previous line for all memory accesses. Enable/Disable L2 Up/Down Prefetcher. Options available: Disable, Enable, Auto. Default setting is Auto. |
| L1 Burst Prefetch Mode | Enable/Disable L1 Burst Prefetch Mode. Options available: Disable, Enable, Auto. Default setting is Auto. |
2-3-1-3 Core Watchdog

Parameter Description
Core Watchdog
| Core Watchdog Timer Enable(Note) | Enable/Disable CPU Watchdog Timer. Options available: Disabled, Enabled, Auto. Default setting is Auto. |
| Core Watchdog Timer Interval | Select the CPU Watchdog Timer interval. Options available: 2.681s, 1.340s, 669.41ms, 334.05ms, 166.37ms, 82.53ms, 40.61ms, 20.970ms, 10.484ms,5.241ms, 2.620ms, 1.309ms, 654.08us, 326.4us, 162.56us, 80.64us, 39.68us, Auto. Default setting is Auto. |
2-3-2 DF Common Options

| Parameter Description | |
| DF Common Options | |
| Memory Addressing Press [Enter] for configuration of advanced items. | |
| ACPI Press [Enter] for configuration of advanced items. | |
| Link Press [Enter] for configuration of advanced items. | |
| SDCI Press [Enter] for configuration of advanced items. | |
| Probe Filter Press [Enter] for configuration of advanced items. | |
| DF Watchdog Timer Interval | Configs the Data Fabric watchdog timer interval. Options available: Auto, 41ms, 166ms, 334ms, 669ms, 1.34 seconds, 2.68 seconds, 5.36 seconds. Default setting is Auto. |
| Disable DF to external IP sync flood propagation | Enable/Disable SyncFlood to UMC & downstream slaves. Options available: Sync flood disabled, Sync flood enabled, Auto. Default setting is Auto. |
| Sync flood propagation to DF Components | Enable/Disable DF Sync Flood propagation. Options available: Sync flood disabled, Sync flood enabled, Auto. Default setting is Auto. |
| Freeze DF module queues on error | Options available: Disabled, Enabled, Auto. Default setting is Auto. |
| CC6 memory region encryption | Controls whether or not the CC6 save/restor memory is encrypted. Options available: Disabled, Enabled, Auto. Default setting is Auto. |
| CCD B/W Balance Throttle Level | Options available: Auto, Level 0, Level 1, Level 2, Level 3, Level 4. Default setting is Auto. |
| Number of PCI Segments | Options available: 1 Segment, 2 Segments, 4 Segments, Auto. Default setting is Auto. |
2-3-2-1 Memory Addressing

| Parameter Description | |
| Memory Addressing | |
| NUMA nodes per socket | Specifies the number of desired NUMA nodes per socket. Options available: NPS0, NPS1, NPS2, NPS4, Auto. Default setting is Auto. NOTE! • Available options may vary by system configuration. • Only dual processor configuration supports NPS0. |
| Memory interleaving | Enable/Disable the Memory interleaving feature. Options available: Disabled, Auto, Enabled. Default setting is Auto. |
| 1TB remap | Enable/Disable to remap DRAM out of the space just below the 1TB boundary. The ability to remap depends on DRAM configuration, NPS, and interleaving selection, and may not always be possible. Options available: Do not remap, Attempt to remap, Auto. Default setting is Auto. |
| DRAM map inversion | Enable/Disable the DRAM map inversion function. Options available: Disabled, Enabled, Auto. Default setting is Auto. |
| Location of private memory regions | Controls whether or not the private memory regions (PSP, SMU and CC6) are at the top of DRAM or distributed. Options available: Distributed, Consolidated, Auto. Default setting is Auto. |
| CXL Memory interleaving Options available: Disabled, Enabled, Auto. Default setting is Auto. | |
| CXL Sublink interleaving Options available: Enable, Disable, Auto. Default setting is Auto. | |
2-3-2-2 ACPI

| Parameter Description | |
| ACPI | |
| ACPI SRAT L3 Cache As | Enable/Disable report each L3 cache as a NUMA Domain to the OS. |
| NUMA Domain | Options available: Disabled, Enabled, Auto. Default setting is Auto. |
| ACPI SLIT Distance Control | Determines how the SLIT distances are declared. Options available: Manual, Auto. Default setting is Auto. |
| ACPI SLIT remote relative distance | Sets the remote socket distance for 2P systems as near (2.8) or far (3.2). Options available: Near, Far, Auto. Default setting is Auto. |
2-3-2-3 Link

| Parameter Description | |
| GMI encryption control | Enable/Disable GMI link encryption. Options available: Disabled, Enabled, Auto. Default setting is Auto. |
| xGMI encryption control | Enable/Disable xGMI link encryption. Options available: Disabled, Enabled, Auto. Default setting is Auto. |
| xGMI Link Configuration | Configs the number of xGMI2 links used on a multi-socket system. Options available: Auto, 3 xGMI Links, 4 xGMI Links. Default setting is Auto. |
| 4-link xGMI max speed | Specifies the max speed of 4-link xGMI. Options available: 12Gbps, 16Gbps, 17Gbps, 18Gbps, 20Gbps, 22Gbps, 23Gbps, 24Gbps, 25Gbps, 26Gbps, 27Gbps, 30Gbps, 32Gbps, Auto. Default setting is Auto. |
| 3-link xGMI max speed | Specifies the max speed of 3-link xGMI. Options available: 12Gbps, 16Gbps, 17Gbps, 18Gbps, 20Gbps, 22Gbps, 23Gbps, 24Gbps, 25Gbps, 26Gbps, 27Gbps, 30Gbps, 32Gbps, Auto. Default setting is Auto. |
| xGMI 18GACOFC | Configs xGMI 18GACOFC. Options available: Auto, Enable, Disable. Default setting is Auto. |
| xGMI CRC Scale | Configs leaky bucket scale for xGMI and WAFL CRC errors. Every scale milliseconds an error will leak from the CRC counter. Default setting is 7. |
| xGMI CRC Threshold | Configs leaky bucket threshold for xGMI and WAFL CRC errors. If link CRC counter exceeds this threshold, an error will be logged. Default setting is 25. |
| xGMI Preset Control | Enable/Disable xGMI Preset control. Options available: Disabled, Enabled, Auto. Default setting is Auto. |
| xGMI Global Preset List Press [Enter] to configure the xGMI Preset list. | |
| xGMI Initial Preset Press [Enter] to configure the xGMI Initial Preset CPU link. | |
| xGMI TXEQ Search Mask Press [Enter] to configure the xGMI TXEQ Search Mask CPU link. | |
| xGMI AC/DC Coupled Link | Press [Enter] to configure the xGMI AC/DC Coupled link. • xGMI AC/DC Coupled Link Control (Note) - Options available: Manual, Auto. Default setting is Auto. |
| xGMI Channel Type | Press [Enter] to configure the xGMI Channel Type. • xGMI Channel Type Control (Note) - Options available: Manual, Auto. Default setting is Auto. |
2-3-2-4 SDCI

| Parameter Description | |
| SDCI(Note) | Options available: Disabled, Enabled, Auto. Default setting is Auto. |
| DisRmSteer Options available: Disabled, Enabled, Auto. Default setting is Auto. | |
(Note) Advanced items prompt when this item is defined.
2-3-2-5 Probe Filter

| Parameter Description | |
| Organization | Specifies whether multiple memory/CXL channels will share probe filter storage. Options available: Auto, Dedicated, Shared. Default setting is Dedicated. |
| Periodic Directory Rinse (PDR) | Controls PDR settings that may impact performance by workload and/or processor. |
| Tuning | Options available: Memory-Sensitive, Cache-Bound, Neutral, Auto. Default setting is Auto. |
2-3-3 UMC Common Options

| Parameter Description |
| UMC Common Options |
| DDR Addressing Options Press [Enter] for configuration of advanced items. |
| DDR Controller Configuration Press [Enter] for configuration of advanced items. |
| DDR MBIST Options Press [Enter] for configuration of advanced items. |
| DDR RAS Press [Enter] for configuration of advanced items. |
| DDR Bus Configuration Press [Enter] for configuration of advanced items. |
| Enforce POR Press [Enter] for configuration of advanced items. |
| DDR Training Options Press [Enter] for configuration of advanced items. |
| DDR Security Press [Enter] for configuration of advanced items. |
| DDR PMIC Configuration Press [Enter] for configuration of advanced items. |
| DDR Miscellaneous Press [Enter] for configuration of advanced items. |
| DDR PHY (CMN) Press [Enter] for configuration of advanced items. |
2-3-3-1 DDR Addressing Options

| Parameter Description | |
| DDR Addressing Options | |
| Chipselect Interleaving | Interleaves memory blocks across the DRAM chip selects for node 0. Options available: Disabled, Auto. Default setting is Auto. |
| Address Hash Bank | Enable or disable bank addressing hashing. Options available: Disabled, Enabled, Auto. Default setting is Auto. |
| Address Hash CS | Enable or disable CS addressing hashing. Options available: Auto, Enabled, Disabled. Default setting is Auto. |
| Address Hash Subchannel | Enable or disable sub-channel addressing hashing. Options available: Auto, Enabled, Disabled. Default setting is Auto. |
| BankSwapMode Options available: Auto, Disabled, Swap CPU. Default setting is Auto. | |
2-3-3-2 DDR Controller Configuration

Parameter Description
DDR Cotroller Configuration
DDR Power Options Press [Enter] for configuration of advanced items.
Memory Channel Disable Press [Enter] for configuration of advanced items.
Refresh Management (RFM) Press [Enter] for configuration of advanced items.
2-3-3-2-1 DDR Power Options

| Parameter Description | |
| DDR Power Options | |
| Power Down Enable | Enable or disable DDR power down mode. Options available: Disabled, Enabled, Auto. Default setting is Auto. |
| Sub Urgent Refresh Lower Bound | Specifies the stored refresh limit required to enter sub-urgent refresh mode. |
| Urgent Refresh Limit Specifies the stored refresh limit required to enter urgent refresh mode. | |
| DRAM Refresh Rate | DRAM refresh rate: 1.95us or 3.9us. Options available: 3.9 usc, 1.95usec. Default setting is 3.9 usec. |
| Self-Refresh Exit Staggering Options available: Disabled, n=1~9. Default setting is n=9. | |
2-3-3-2-2 Memory Channel Disable

| Parameter Description |
| Memory Channel Disable |
| Memory Channel Disable Bitmask |
| Socket 0 Channel_# Press [Enter] to enable/disable specific memory channel. |
2-3-3-2-3 Refresh Management (RFM)

| Parameter Description | |
| Refresh Management (RFM) | |
| Refresh Management | Configure Refresh Management. Options available: Enable, Disable, Auto, Force Enable. Default setting is Auto. |
| RAA Initial Management Threshold | Override Rolling Accumulated ACT Initial Management Threshold. Options available: 32, 40, 48, 56, 64, 72, 80, Auto. Default setting is Auto. |
| RAA Maximum Management Threshold | Override Rolling Accumulated ACT Maximum Management Threshold. Options available: 3X, 4X, 5X, 6X, Auto. Default setting is Auto. |
| RAA Refresh Decrement Multiplier | Override RAA Refresh Decrement Multiplier. Options available: 0.5, 1, Auto. Default setting is Auto. |
2-3-3-3 DDR MBIST Options

| Parameter Description | |
| DDR MBIST Options | |
| MBIST Enable | Enable/Disable the Memory MBIST function. Options available: Disabled, Enabled, Auto. Default setting is Auto. |
| MBIST Test Mode(Note1) | Selects MBIST Test Mode. Interface Mode: Tests Single and Multiple CS transactions and Basic Connectivity. Data Eye Mode: Measures Voltage vs. Timing. Options available: Auto, Both, Interface Mode, Data Eye Mode. Default setting is Auto. |
| MBIST Aggressors(Note1) | Enable/Disable MBIST Aggressor test. Options available: Auto, Enabled, Disabled. Default setting is Auto. |
| MBIST Per Bit Slave Die Reporting(Note1) | Enable/Disable to report 2D data eye results in ABL log for each DQ, Chipselect, and Channel. Options available: Auto, Enabled, Disabled. Default setting is Auto. |
| Data Eye | Press [Enter] to configure advanced items. |
| Memory Healing BIST | Enable/Disable memory healing BIST. Options available: Disabled, PMU Mem BIST, Self-Healing Mem BIST, PMU and Self-Healing Mem BIST. Default setting is Disabled. |
(Note1) This item appears when MBIST Enable is set to Enabled.
| Parameter Description | |
| DDR Healing BIST Execution Mode(Note2) | Options available: One Time, Every boot. Default setting is One Time. |
| PMU Mem BIST Algorithm(Note2) | Press [Enter] to enable/disable PMU Mem BIST Algorithm. |
| DDR Healing BIST Repair Type(Note2) | For DRAM errors found in the BIOS memory BIST select the repair type. Options available: Soft Repair, Hard Repair, No Repairs -Test only. Default setting is Soft Repair. |
(Note2) This item appears when DDR Healing BIST is defined.
2-3-3-3-1 Data Eye

| Parameter | Description |
| Data Eye | |
| Pattern Select | Options available: PRBS, SSO, Both. Default setting is PRBS. |
| Pattern Length | Determines the pattern length. The possible options are N=3....12. |
| Aggressor Channel | This item helps read the aggressors channels. Options available: One Sub-Channel, Half Channels, All Channels. Default setting is All Channels. |
| Aggressor Static Lane Control | Enable/Disable the Aggressor Static Lane Control function. Options available: Enabled, Disabled. Default setting is Disabled. |
| Aggressor Static Lane Select Upper 32 bits | This item is configurable when Aggressor Static Lane Control is set to Enabled. |
| Aggressor Static Lane Select Lower 32 bits | This item is configurable when Aggressor Static Lane Control is set to Enabled. |
| Aggressor Static Lane Select ECC | This item is configurable when Aggressor Static Lane Control is set to Enabled. |
| Aggressor Static Lane Value | This item is configurable when Aggressor Static Lane Control is set to Enabled. |
| Target Static Lane Control | Enable/Disable the Target Static Lane Control function. Options available: Enabled, Disabled. Default setting is Disabled. |
| Target Static Lane Select Upper 32 bits | This item is configurable when Target Static Lane Control is set to Enabled. |
| Target Static Lane Select Lower 32 bits | This item is configurable when Target Static Lane Control is set to Enabled. |
| Target Static Lane Select ECC | This item is configurable when Target Static Lane Control is set to Enabled. |
| Target Static Lane Value | This item is configurable when Target Static Lane Control is set to Enabled. |
| Worst Case Margin Granularity | Configs Worst Case Margin Granularity. Options available: Per Chip Select, Per Nibble. Default setting is Per Chip Select. |
| Read Voltage Sweep Step Size | Configs the step size for read Data Eye voltage sweep. Options available: 1, 2, 4. Default setting is 1. |
| Read Timing Sweep Step Size | Configs the step size for read Data Eye timing sweep. Options available: 1, 2, 4. Default setting is 1. |
| Write Voltage Sweep Step Size | Configs the step size for write Data Eye voltage sweep. Options available: 1, 2, 4. Default setting is 1. |
| Write Timing Sweep Step Size | Configs the step size for write Data Eye timing sweep. Options available: 1, 2, 4. Default setting is 1. |
| Silent Execution | Execute MBIST Data Eye silently without ABL log output. Options available: Enabled, Disabled. Default setting is Disabled. |

Parameter Description
| DDR RAS | |
| Data Poisoning | Enable/Disable the Data Poisoning function. Options available: Auto, Enabled, Disabled. Default setting is Auto. |
| DRAM Boot Time Post Package Repair | Enable/Disable the DRAM Boot Time Post Package Repair function. Options available: Enable, Disable. Default setting is Disable. |
| DRAM Runtime Post Package Repair | Enable/Disable the DRAM Runtime Post Package Repair function. Options available: Enable, Disable. Default setting is Disable. |
| RCD Parity | Enable/Disable the RCD Parity function. Options available: Auto, Enabled, Disabled. Default setting is Enabled. |
| Max RCD Parity Error Replay Default setting is 8. | |
| Disable Memory Error Injection | Options available: False, True, Auto. Default setting is Auto. |
| ECC Configuration | Press [Enter] to configure advanced items. ◆ DRAM ECC Symbol Size - Configures the DRAM ECC Symbol Size. - Options available: Auto, x4, x16. Default setting is Auto. ◆ DRAM ECC Enable - Enable/Disable DRAM ECC. When set to Auto, it will set ECC to enable. - Options available: Auto, Enabled, Disabled. Default setting is Auto. |
| Parameter Description | |
| ECC Configuration(continued) | DRAM UECC Retry- Enable/Disable DRAM UECC Retry.- Options available: Auto, Enabled, Disabled. Default setting isDisabled.Max DRAM UECC Error Replay(Note)- Default setting is 8.Memory Clear- Options available: Auto, Enabled, Disabled. Default setting isAuto ADDRESS XDR after ECC- Options available: Auto, Enabled, Disabled. Default setting isDisabled. |
| DRAM Scrubbers | Press [Enter] to configure advanced items.DRAM ECS Mode- Options available: Auto, AutoECS, ManualECS, DisableECS.Default setting is Auto.DRAM Redirect Scrubber Enable- Options available: Auto, Enabled, Disabled. Default setting isAuto.DRAM Scrub Redirection Limit- Options available: Auto, 8 Scrubs, 4 Scrubs, 2 Scrubs, 1 Scrub.Default setting is Auto.DRAM Scrub Time- Options available: Disabled, 1 hour, 4 hours, 6 hours, 8 hours,12 hours, 16 hours, 24 hours, 48 hours. Default setting is 24Hours.DRAM Error Threshold Count- Options available: Auto, ETC_4, ETC_16, ETC_64, ETC_256,ETC_1024, ETC_4096. Default setting is Auto.DRAM ECS Count Mode- Options available: Auto, Row Count Mode, Code Word CountMode. Default setting is Auto.DRAM AutoEcs during Self Refresh- Options available: Auto, AutoEcs Disabled, AutoEcs Enabled.Default setting is Auto.DRAM ECS WriteBack Suppression- Options available: Auto, Enable, Disable. Default setting isAuto.DRAM X4 WriteBack Suppression- Options available: Auto, Enable, Disable. Default setting isAuto. |
| DRAM Corrected Error Counter Enable | Configure DRAM Corrected Error Counter function. Options available: Disable, NoLeakMode, LeakMode. Default setting is LeakMode. |
| DRAM Corrected Error Counter Interrupt Enable | Enable SMI when DRAM corrected Error Counter count exceeds the threshold value. Options available: False, True. Default setting is True. |
| DRAM Corrected Counter Leak Rate | Program Rate value for DRAM Corrected Error Counter function. Default setting is 7. |
| DRAM Corrected Error Counter Start Count | Program starting value for DRAM Corrected Error Counter function. Default setting is FFF5. |
2-3-3-5 DDR Bus Configuration

| Parameter Description | |
| DDR Bus Configuration | |
| Dram ODT impedance RTT_NOM_WR | Select the DRAMs On-die Termination impedance for RTT_NOM_WR. Options available: Auto, RTT_OFF, RZQ (240), RZQ/2 (120), RZQ/3 (80) RZQ/4 (60), RZQ/5(48), RZQ/6(40), RZQ/7(34). Default setting is Auto. |
| Dram ODT impedance RTT_NOM_RD | Select the DRAMs On-die Termination impedance for RTT_NOM_RD. Options available: Auto, RTT_OFF, RZQ (240), RZQ/2 (120), RZQ/3 (80) RZQ/4 (60), RZQ/5(48), RZQ/6(40), RZQ/7(34). Default setting is Auto. |
| Dram ODT impedance RTT_WR | Select the DRAMs On-die Termination impedance for RTT_WR. Options available: Auto, RTT_OFF, RZQ (240), RZQ/2 (120), RZQ/3 (80) RZQ/4 (60), RZQ/5(48), RZQ/6(40), RZQ/7(34). Default setting is Auto. |
| Dram ODT Timpeadance RTT_PARK | Select the DRAMs On-die Termination impedance for RTT_PARK. Options available: Auto, RTT_OFF, RZQ (240), RZQ/2 (120), RZQ/3 (80) RZQ/4 (60), RZQ/5(48), RZQ/6(40), RZQ/7(34). Default setting is Auto. |
| Dram ODT Timpeadance DQS_RTT_PARK | Select the DRAMs On-die Termination impedance for DQS_RTT_PARK. Options available: Auto, RTT_OFF, RZQ (240), RZQ/2 (120), RZQ/3 (80) RZQ/4 (60), RZQ/5(48), RZQ/6(40), RZQ/7(34). Default setting is Auto. |
| Processor ODT impedance | Select the ODT impedance for all DBYTE IOs. Options available: Auto, High Impedance, 480 ohm, 240 ohm, 160 ohm, 120 ohm, 96 ohm, 80 ohm, 68.6 ohm, 60 ohm, 53.3 ohm, 48 ohm, 43.6 ohm, 40 ohm, 36.9 ohm, 34.3 ohm, 32 ohm, 30 ohm, 28.2 ohm, 26.7 ohm, 25.3 ohm. Default setting is Auto. |
| Dram DQ drive strengths | Select the Dram Pull-up and Pull-Down Output Driver Impedance for all DQ and DMI IOs.. Options available: Auto, 48 ohm, 40 ohm, 34 ohm, Default setting is Auto. |
2-3-3-6 Enforce POR

| Parameter Description | |
| Enforce POR Decline/Accept to configure the advanced items. | |
| Accept | |
| Active Memory Timing Settings (Note) | Active memory Timing Settings. Options available: Auto, Enabled. Default setting is Auto. |
| Memory Target Speed | Specifies the memory target speed in MT/s. Options available: Auto, DDR3200, DDR3600, DDR4000, DDR44 DDR4800, DDR5200, DDR5600. Default setting is Auto. |
| SPD Timing Press [Enter] to configure advanced items. | |
| Non-SPD Timing Press [Enter] to configure advanced items. | |
2-3-3-7 DDR Training Options

| Parameter Description | |
| DDR Training Options | |
| DRAM PDA Enumerate ID Programming Mode | Specify PDA enumeration mode. Options available: Auto, Toggling PDA enumeration mode, Legacy PDA enumeration mode. Default setting is Auto. |
2-3-3-8 DDR Security

| Parameter Description | |
| Security | |
| TSME | Enable/Disable Transparent SME. Options available: Auto, Enabled, Disabled. Default setting is Auto. |
| AES Options available: AES-128, AES-256. Default setting is AES-256. | |
| Data Scramble | Enable/Disable Data Scrambling. Options available: Enabled, Disabled. Default setting is Enabled. |
| SME-MK Options available: Enabled, Disabled. Default setting is Disabled. | |
2-3-3-9 DDR PMIC Configuration

| Parameter Description | |
| DDR PMIC Configuration | |
| PMIC Error Reporting | Enables support for PMIC Error Reporting. Options available: Auto, False, True. Default setting is Auto. |
| PMIC Operation Mode | Options available: Secure Mode, Programmable Mode. Default setting is Programmable Mode. |
| PMIC Fault Recovery Options available: Always, Never, Once. Default setting is Always. | |
| PMIC SWC VDDIO Default setting is 1100. | |
| PMIC SWA/SWB VDD Core Default setting is 1100. | |
| PMIC Stagger Delay Default setting is 5. | |
| Max PMIC Power On Default setting is FF. | |
2-3-3-10 DDR Miscellaneous

Parameter Description
DDR Miscellaneous
DRAM Survives Warm Reset Options available: Enabled, Disabled. Default setting is Disabled.
ODTS CMD Throttle Threshold Options available: Auto, >85^, > 90^, > 95^ . Default setting is Auto.
2-3-3-11 DDR PHY (CMN)

Parameter Description
DDR PHY (CMN)
Periodic Training (Note)
Options available: Auto, Enabled, Disabled. Default setting is Auto.
Periodic Training Interval Specifies the Periodic Training interval in millisecond.
2-3-4 NBIO Common Options


| Parameter | Description |
| NBIO Common Options | |
| IOMMU | Enable/Disable the IOMMU function. Options available: Disabled, Enabled. Default setting is Enabled. |
| DMAr Support | Enable/Disable DMAr system protection during POST. Options available: Disabled, Enabled, Auto. Default setting is Auto. |
| DMA Protection | Enable/Disable DMA remap support in IVRS IVinfo Field. Options available: Auto, Enabled, Disabled. Default setting is Auto. |
| DRTM Virtual Device Support | Enable/Disable DRTM ACPI virtual device. Options available: Disabled, Enabled, Auto. Default setting is Auto. |
| DRTM Memory Reservation | Enable/Disable DRTM Memory reservation. Options available: Disabled, Enabled, Auto. Default setting is Auto. |
| ACS Enable | Enable/Disable ACS. Options available: Enable, Disabled, Auto. Default setting is Auto. |
| PCIe ARI Support | Enable/Disable Alternative Routing-ID Interpretation. Options available: Disable, Enable, Auto. Default setting is Auto. |
| PCIe ARI Enumeration | ARI Forwarding Enable for each downstream port. Options available: Disable, Enable, Auto. Default setting is Auto. |
| PCIe Ten Bit Tag Support | Enable/Disable PCIe ten bit tags for supported devices. (Auto=Disabled) Options available: Disable, Enable, Auto. Default setting is Auto. |
| SMU Common Options Press [Enter] for configuration of advanced items. | |
| NBIO RAS Common Options | Press [Enter] for configuration of advanced items. |
| Enable AER Cap | Enable/Disable Advanced Error Reporting Capability. Options available: Enable, Disabled, Auto. Default setting is Auto. |
| Early Link Speed | Configs Early Link Speed. Options available: Auto, Gen1, Gen2. Default setting is Auto. |
| Hot Plug Handling mode | Controls the Hot Plug Handling mode. Options available: OS First, Firmware First/EDR if OS supports, Firmware First but allow OS First, System Firmware Intermediary, Auto. Default setting is Auto. |
| Hot Plug Allow FF in Synchronous | Allows firmware first hot plug handling mode to operate in mode A and mode B synchronous mappings. Options available: Disabled, Enabled. Default setting is Disabled. |
| Presence Detect Select mode | Controls the Presence Detect Select mode. Options available: OR, AND, Auto. Default setting is Auto. |
| Data Link Feature Cap | Enable/Disable the data link feature capability. Options available: Enabled, Disabled, Auto. Default setting is Auto. |
| CV test | Enable/Disable the running PCIE CV tool support. Options available: Auto, Enabled, Disabled. Default setting is Auto. |
| SEV-SNP Support | Enable/Disable the SEV-SNP support. Options available: Disable, Enable. Default setting is Disable. |
| Allow Compliance | When enabled, allows the PCIe RP to enter Polling.Compliance state. Options available: Auto, Disable, Enable. Default setting is Auto. |
| SRIS Options available: Auto, Disable, Enable. Default setting is Auto. | |
| Multi Upstream Auto Speed Change | Defines the setting of this feature for all PCIe devices. Options available: Disabled, Enabled, Auto. Default setting is Auto. |
| Multi Auto Speed Change On Last Rate | Options available: Disable, Enable, Auto. Default setting is Auto. |
| PCIE Link Speed Capability | Options available: Maximum speed, Gen1, Gen2, Gen3, Gen4, Gen5, Auto. Default setting is Auto. |
| RTM Margining Support Options available: Disable, Enable, Auto. Default setting is Auto. | |
| EQ Bypass To Highest Rate | Options available: Disable, Enable, Auto. Default setting is Auto. |
| Non-PCIe Compliant Support | Options available: Disable, Enable, Auto. Default setting is Auto. |
| PCIE Idle Power Setting | Modify PCIE Power Savings Features that can impact lightly loaded latency. Options available: Optimize for Latency, Optimize for Perf/Power. Default setting is Optimize for Latency. |
| nBif Common Options Press [Enter] for configuration of advanced items. | |
| Link EQ Preset Options Press [Enter] for configuration of advanced items. | |
| Enable 2 SPC (Gen4) | Enable this setting to use 2 symbols per clock for devices at Gen4 speed. Options available: Auto, Enabled. Default setting is Auto. |
2-3-4-1 SMU Common Options

| Parameter | Description |
| SMU Common Options | |
| TDP Control | Options available: Manual, Auto. Default setting is Auto. |
| PPT Control | Options available: Manual, Auto. Default setting is Auto. |
| Determinism Control | Selects use the fused Determinism or set customized Determinism. Options available: Manual, Auto. Default setting is Auto. |
| xGMI Link Width Control Options available: Manual, Auto. Default setting is Auto. | |
| APBDIS Options available: 0, 1, Auto. Default setting is Auto. | |
| DfPstate Range Support Options available: Disable, Enable, Auto. Default setting is Auto. | |
| Power Profile Selection | Options available: High Performance Mode, Efficiency Mode, Maximum IO Performance Mode. Default setting is High Performance Mode. |
| BoostFmaxEn Options available: Manual, Auto. Default setting is Auto. | |
| DF PState Frequency Optimizer | Options available: Auto, Enabled, Disabled. Default setting is Auto. |
| DF Cstates Options available: Disabled, Enabled, Auto. Default setting is Auto. | |
| CPPC | Enable/Disable the CPPC feature. Options available: Disabled, Enabled, Auto. Default setting is Auto. |
| HSMP Support | Enable/Disable the HSMP support. Options available: Disabled, Enabled, Auto. Default setting is Auto. |
| SVI3 SVC Speed Control | Options available: Auto, Manual. Default setting is Auto. |
| 3D V-Cache Options available: Auto, Disable, 1 stack. Default setting is Auto. | |
| Diagnostic Mode Options available: Disabled, Enabled, Auto. Default setting is Auto. | |
| PCIE Speed PMM Control | Options available: Dynamic link speed determined by Power Management functionality, Static Target Link Speed (GEN4), Static Target Link Speed (GEN5), Auto. Default setting is Auto. |
2-3-4-2 NBIO RAS Common Options

| Parameter | Description |
| NBIO RAS Common Options | |
| NBIO RAS Control Options available: Disabled, MCA, Auto. Default setting is Auto. | |
| Egress Poison Severity High | Configs the Egress Poison High Severity. Each bit set to 1 enables High severity on the associated IOHC egress port. A bit of 0 indicates LOW severity. |
| Egress Poison Severity Low | Configs the Egress Poison Low Severity. Each bit set to 1 enables High severity on the associated IOHC egress port. A bit of 0 indicates LOW severity. |
| NBIO SyncFlood Generation | The value may be used to mask SyncFlood caused by NBIO RAS options. Options available: Enabled, Disabled, Auto. Default setting is Auto. |
| NBIO SyncFlood Reporting | The value may be used to enable SyncFlood reporting to APML. Options available: Enabled, Disabled, Auto. Default setting is Auto. |
| Egress Poison Mask High | Enables mask for masking of errors logged in EGRESS_POISON_STATUS. For each bit set to 1, errors are masked. For each bit set to 0, errors trigger response actions. |
| Egress Poison Mask Low | Enables mask for masking of errors logged in EGRESS_POISON_STATUS. For each bit set to 1, errors are masked. For each bit set to 0, errors trigger response actions. |
| Uncorrected Converted to Poison Enable Mask High | Enables mask for masking of uncorrectable parity errors on internal arrays. |
| Uncorrected Converted to Poison Enable Mask Low | Enables mask for masking of uncorrectable parity errors on internal arrays. |
| System Hub Watchdog Timer | Specifies the timer interval of the SYSHUB Watchdog timer in milliseconds. |
| PCIe Aer Reporting Mechanism | Selects the method of reporting AER errors from PCI Express. Options available: Firmware First, Firmware Frist but allow OS First, OS First, Auto. Default setting is Auto. |
| Edpc Control Options available: | Disabled, Enabled, Auto. Default setting is Auto. |
| ACS RAS Request Value | Options available: Direct Request Access Enabled, Request Blocking Enabled, Request Redirect Enabled, Auto. Default setting is Auto. |
| NBIO Poison Consumption Options available: | Auto, Enabled, Disabled. Default setting is Auto. |
| Sync Flood on PCIe Fatal Error | Options available: Auto, True, False. Default setting is Auto. |
2-3-4-3 nBif Common Options

| Parameter | Description |
| MPDMA-TF | • SROV - Options available: Auto, Disable, Enable. Default setting is Auto. • ARI - Options available: Auto/Default, Disable, Enable. Default setting is Auto/Default. • AER - Options available: Auto, Disable, Enable. Default setting is Auto. • ACS - Options available: Auto, Disable, Enable. Default setting is Auto. • ATS - Options available: Auto, Disable, Enable. Default setting is Auto. • PASID - Options available: Auto, Disable, Enable. Default setting is Auto. • RTR - Options available: Auto, Disable, Enable. Default setting is Auto. • PAGE_REQ - Options available: Auto, Disable, Enable. Default setting is Auto. • PWR - Options available: Auto, Disable, Enable. Default setting is Auto. • ATC_ENABLE - Options available: Auto, Disable, Enable. Default setting is Auto. |
| RCC_DEV0 | ·ACS Rcc Dev0 -Options available: Auto, Disable, Enable. Default setting is Auto. ·AER Rcc Dev0 -Options available: Auto, Disable, Enable. Default setting is Auto. ·DlfEnableStrap1 -Options available: Auto, Disable, Enable. Default setting is Auto. ·Phy16GTrap1 -Options available: Auto, Disable, Enable. Default setting is Auto. ·MarginEnStrap1 -Options available: Auto, Disable, Enable. Default setting is Auto. ·SourceValStrap5 -Options available: Auto, Disable, Enable. Default setting is Auto. ·TranslationalBlockingStrap5 -Options available: Auto, Disable, Enable. Default setting is Auto. ·P2pReq ACS Control -Options available: Auto, Disable, Enable. Default setting is Auto. ·P2pCompStrap5 -Options available: Auto, Disable, Enable. Default setting is Auto. ·UpstreamFwdStrap5 -Options available: Auto, Disable, Enable. Default setting is Auto. ·P2PEgressStrap5 -Options available: Auto, Disable, Enable. Default setting is Auto. ·DirectTranslatedStrap5 -Options available: Auto, Disable, Enable. Default setting is Auto. ·SsidEnStrap5 -Options available: Auto, Disable, Enable. Default setting is Auto. ·PriEnPageReq -Options available: Auto, Disable, Enable. Default setting is Auto. ·PriResetPageReq -Options available: Auto, Disable, Enable. Default setting is Auto. ·SourceVal ACS cntl -Options available: Auto, Disable, Enable. Default setting is Auto. ·TranslationalBlocking ACS Control -Options available: Auto, Disable, Enable. Default setting is Auto. ·P2pComp ACS Control -Options available: Auto, Disable, Enable. Default setting is Auto. ·UpstreamFwd ACS Control -Options available: Auto, Disable, Enable. Default setting is Auto. ·P2PEgress ACS Control -Options available: Auto, Disable, Enable. Default setting is Auto. ·P2pReqStrap5 -Options available: Auto, Disable, Enable. Default setting is Auto. ·E2E_PREFIX -Options available: Auto, Disable, Enable. Default setting is Auto. |
| RCC_DEV0 | • EXTENDED_FMT |
| (continued) | - Options available: Auto, Disable, Enable. Default setting is Auto. |
2-3-4-4 Link EQ Preset Options

| Parameter | Description |
| GEN3/4/5 | Press [Enter] to configure advanced items. |
| • Preset Search Mask Configuration | |
| - Options available: Custom, Auto. Default setting is Auto. |
2-3-5 FCH Common Options

Parameter Description
FCH Common Options
I3C/I2C Configuration Options Press [Enter] for configuration of advanced items.
SATA Configuration Options Press [Enter] for configuration of advanced items.
USB Configuration Options Press [Enter] for configuration of advanced items.
AC Power Loss Options Press [Enter] for configuration of advanced items.
Uart Configuration Options Press [Enter] for configuration of advanced items.
ESPI Configuration Options Press [Enter] for configuration of advanced items.
FCH RAS Options Press [Enter] for configuration of advanced items.
Miscellaneous Options Press [Enter] for configuration of advanced items.
2-3-5-1 I3C/I2C Configuration Options

| Parameter | Description |
| I3C/I2C Configuration Options | |
| I3C/I2C 0/1/2/3 Enable | Options available: Both Disabled, I3C Enabled, I2C Enabled, Auto. Default setting is Auto. |
| I2C 4/5 Enable | Options available: Disabled, Enabled, Auto. Default setting is Auto. |
| Release SPD Host Control | Options available: Disabled, Enabled. Default setting is Disabled. |
| PMFW Poll DDR5 Telemetry | Options available: Disabled, Enabled. Default setting is Enabled. |
| Ixc Telemetry Ports Fence Control | Options available: Disabled, Enabled. Default setting is Disabled. |
| I2C SDA Hold Override | Options available: Disabled, Enabled, Auto. Default setting is Auto. |
| APML SB-TSI $ RMI Mode | Options available: I3C, I2C. Default setting is I3C. |
| I3C Mode Speed | Options available: SDR2(6MHz), SDR0(12.5MHz), Auto. Default setting is Auto. |
| I3C Push Pull HCNT Value | SCL push-pull High count for I3C transfers targeted to I3C devices. |
| I3C SDA Hold Override | Override I3C SDA Hold value. Options available: Disabled, Enabled, Auto. Default setting is Auto. |
2-3-5-2 SATA Configuration Options

| Parameter | Description |
| SATA Configuration Options | |
| SATA Enable | Enable/Disable OnChip SATA controller. Options available: Disabled, Enabled, Auto. Default setting is Auto. |
| SATA RAS Support | Options available: Disabled, Enabled, Auto. Default setting is Auto. |
| SATA Staggered Spin-up | Options available: Disabled, Enabled, Auto. Default setting is Auto. |
| SATA Disabled AHCI prefetch Function | Options available: Disabled, Enabled, Auto. Default setting is Auto. |
| Aggressive SATA Device Sleep P0/P1 | Options available: Disabled, Enabled, Auto. Default setting is Auto. |
| SATA Controller options | Press [Enter] for configuration of advanced items. • SATA Controller Enable • SATA Controller eSATA • SATA Controller DevSlp • SATA Controller SGPIO |
2-3-5-3 USB Configuration Options

| Parameter | Description |
| USB Configuration Options | |
| XHCI Controller0/1 enable | Enable/Disable USB controller. Options available: Enabled, Disabled, Auto. Default setting is Auto. |
| USB ecc SMI Enable | Options available: Enable, Off, Auto. Default setting is Auto. |
| MCM USB enable | Press [Enter] for configuration of advanced items. • XHCI2/ XHCI3 enable (Socket1) - Options available: Enabled, Disabled, Auto. Default setting is Auto. |
2-3-5-4 AC Power Loss Options

| Parameter | Description |
| AC Power Loss Options | |
| AC Loss Control | Selects the AC Loss Control Method. Options available: Power Off, Power On, Last State. Default setting is Last State. |
2-3-5-5 Uart Configuration Options

| Parameter | Description |
| Uart Configuration Options | |
| Uart 0/1/2/3 Enable | Options available: Disabled, Enabled, Auto. Default setting is Auto. |
2-3-5-6 ESPI Configuration Options

| Parameter | Description |
| ESPI Configuration Options | |
| ESPI Enable | Options available: Disabled, Enabled, Auto. Default setting is Auto. |
2-3-5-7 FCH RAS Options

| Parameter | Description |
| FCH RAS Options | |
| ALink RAS Support | Enable/Disable the ALink RAS Support. Options available: Disabled, Enabled, Auto. Default setting is Auto. |
| Reset after sync flood | Enables AB to forward downstream sync-flood message to system controller. Options available: Enable, Disable, Auto. Default setting is Auto. |
2-3-5-8 Miscellaneous Options

| Parameter | Description |
| Miscellaneous Options | |
| Boot Timer Enable | Enable/Disable Boot Timer. Options available: Disabled, Enabled, Auto. Default setting is Auto. |
2-3-6 SOC Miscellaneous Control

| Parameter | Description |
| SOC Miscellaneous Control | |
| ABL Console Out Control(Note) | Enable/Disable the ConsoleOut function for ABL. Options available: Disable, Enable, Auto. Default setting is Auto. |
| ABL Console Out Serial Port(Note) | Options available: eSPI, SOC UART0, SOC UART1, Auto. Default setting is Auto. |
| ABL Console Out Serial Port IO | Options available: 0x3F8, 0x2F8, 0x3E8, 0x2E8, Auto. Default setting is Auto. |
| ABL Basic Console Out Control | Enable/Disable the Basic ConsoleOut function for ABL. Options available: Disable, Enable, Auto. Default setting is Auto. |
| ABL PMU message Control | To Control the total number of PMU debug messages. Options available: Auto, Detailed debug message, Coarse debug message, Stage completion, Assertion messages, Firmware completion message only. Default setting is Auto. |
| ABL Memory Population message Control | Options available: Warning message, Fatal error. Default setting is Warning message. |
| PSP error injection support | Options available: False, True. Default setting is False. |
(Note) Advanced items are configurable when this item is defined.
Firmware Anti-rollback (FAR)
Press [Enter] for configuration of advanced items.
FAR enforcement state
- Default setting is Enabled.
SPL value in the CPU Fuse
SPL value in the SPL table
FAR Switch
- Options available: Disabled, Enabled, Auto. Default setting is Auto.
2-3-7 Workload Tuning

| Parameter | Description |
| Workload Tuning | |
| Workload Profile | Select the profile for different workloads. Options available: CPU Intensive, Java Throughput, Java Latency, Power Efficiency, Memory Throughput Intensive, Storage IO Intensive, NIC Throughput Intensive, NIC Latency Sensitive, Accelerator Throughput, VMware vSphere Optimized, Linux KVM Optimized, Container Optimized, RDBMS Optimized, Big Data Analytics Optimized, IOT Gateway, HPC Optimized, OpenStack NFV, OpenStack for ReakTime Kernel, Auto. Default setting is Auto. |
| Performance Tracing | Enable to allow capturing performance traces. Options available: Disabled, Enabled, Auto. Default setting is Auto. |
2-3-8 CXL Common Options

| Parameter | Description |
| CXL Common Options | |
| CXL Control Options available: Auto, Enabled, Disabled. Default setting is Auto. | |
| CXL SPM Options available: Auto, Enabled, Disabled. Default setting is Auto. | |
| CXL Encryption Options available: Enabled, Disabled. Default setting is Disabled. | |
| CXL DVSEC Lock Options available: Auto, Enabled, Disabled. Default setting is Auto. | |
| Temp Gen5 Advertisement | Options available: Disabled, Enabled, Auto. Default setting is Auto. |
| Sync Header Bypass Options available: Auto, Enabled, Disabled. Default setting is Auto. | |
| CXL RAS | Press [Enter] for configuration of advanced items. • CXL Protocol Error Reporting - Options available: Disabled, SameAsPcieAer, ForceAerFwFirstIfCxIPresent. Default setting is SameAsPcieAer. • CXL Component Error Reporting - Options available: OS First, FW-First. Default setting is FW-First. |
2-4 AMD PBS Menu
AMD PBS Option menu displays submenu options for configuring the function of AMD PBS. Select a submenu item, then press [Enter] to access the related submenu screen.

Parameter Description
RAS Press [Enter] for configuration of advanced items.
| SPI Locking | Enable/Disable SPI Locking for protect ROM part. Options available: Disabled, Enabled. Default setting is Disabled. |

| Parameter | Description |
| RAS Periodic SMI Control | Enable/Disable the Periodic SMI for polling [MCA Threshold] error. Options available: Disabled, Enabled. Default setting is Enabled. |
| SMI Threshold Configures the SMI Threshold value. | |
| SMI Scale Configures the SMI Scale value. | |
| SMI Scale Unit | Defines the unit of time scale. Options available: millisecond, second, minute. Default setting is millisecond. |
| SMI Period Configures the SMI Period. | |
| GHES Notify Type | Selects the Notification type for deferred/ corrected errors. Options available: Polled, SCI. Default setting is Polled. |
| GHES UnCorr Notify Type | Selects the Notification type for uncorrected errors. Options available: Polled, NMI. Default setting is NMI. |
| PCIe GHES Notify Type | Selects the Notification type for PCIe corrected errors. Options available: Polled, SCI. Default setting is Polled. |
| PCIe UnCorr GHES Notify Type | Selects the Notification type for PCIe uncorrected errors. Options available: Polled, NMI. Default setting is NMI. |
| PCIe Root Port Corr Err Mask Reg | Initialize the PCIe AER Corrected Error Mask register of Root Port. |
| PCIe Root Port UnCorr Err Mask Reg | Initialize the PCIe AER Uncorrected Error Mask register of Root Port. |
| PCIe Root Port UnCorr Err Sev Reg | Initialize the PCIe AER Uncorrected Error Severity register of Root Port. |
| PCIe Device Corr Err Mask Reg | Initialize the PCIe AER Corrected Error Mask register of PCIe device. |
| PCIe Device UnCorr Err Mask Reg | Initialize the PCIe AER Uncorrected Error Mask register of PCIe device. |
| PCIe Device UnCorr Err Sev Reg | Initialize the PCIe AER Uncorrected Error Severity register of PCIe device. |
| DRAM Hard Post Package Repair | This feature allows spare DRAM rows to replace malfunctioning rows via an in-field repair mechanism. Options available: Disabled, Enabled. Default setting is Disabled. |
| HEST DMC Structure Support | HEST DMC (Deferred Machine Check) Structure Support. Options available: Disabled, Enabled. Default setting is Disabled. |
| CXL Error Report Support | Enable/Disable CXL Error Reporting. Options available: Disabled, Enabled. Default setting is Disabled. |
2-5 Chipset Setup Menu
Chipset Setup menu displays submenu options for configuring the function of the North Bridge. Select asubmenu item, then press

| Parameter | Description |
| PCIe Link Training Type | Options available: 1 Step, 2 Step. Default setting is 1 Step. |
| PCIe Compliance Mode Options available: Off, On. Default setting is Off. | |
| Program All VR | Enable/Disable program all VR on MB. Options available: Disabled, Enabled. Default setting is Enabled. |
| North Bridge Press [Enter] for configuration of advanced items. | |
| Fabric Resource Press [Enter] for configuration of advanced items. | |
2-5-1 North Bridge

| Parameter | Description |
| North Bridge Configuration | |
| Memory Information | |
| Total Memory Displays the total memory information. | |
| CPU 0 Information Press [Enter] to view information related to CPU 0. | |
2-5-2 Fabric Resource


| Parameter | Description |
| Fabric Resource | |
| CPU 0 NBIO_# PCIe Bus Number | Change CPU 0 NBIO_# PCIe Bus Number. |
| Prefetchable Mnio Above 4G size | Change CPU 0/1 NBIO_# Prefetchable MMIO Above 4G Size. Options available: System Default, 0, 1G, 2G, 4G, 8G, 16G, 32G, 64G, 128G, 256G, 512G, 1T, 2T, 4T, 8T. Default setting is System Default. |
| PCIe IO Resource Change CPU 0 NBIO_# PCIe IO Resource. | |
2-6 Server Management Menu

| Parameter | Description |
| FRB-2 Timer | Enable/Disable FRB-2 timer (POST timer).Default setting is Enabled. |
| FRB-2 Timer timeout | Configs the FRB2 Timer timeoutOPTIONS available: 3 minutes, 4 minutes, 5 minutes, 6 minutes. Default setting is 6 minutes. |
| FRB-2 Timer Policy | Configs the FRB2 Timer policyOPTIONS available: Do Nothing, Reset, Power Down, Power Cycle.Default setting is Do Nothing. |
| OS Watchdog Timer | Enable/Disable OS Watchdog Timer functionOPTIONS available: Enabled, Disabled. Default setting is Disabled. |
| OS Wtd Timer Timeout(Note) | Configs OS Watchdog TimerOPTIONS available: 5 minutes, 10 minutes, 15 minutes, 20 minutes.Default setting is 10 minutes. |
| OS Wtd Timer Policy(Note) | Configure OS Watchdog Timer PolicyOPTIONS available: Do Nothing, Reset, Power Down, Power Cycle.Default setting is Reset. |
| Wait BMC Ready | Post wait BMC ready and reboot systemOPTIONS available: Disabled, 2 minutes, 4 minutes, 6 minutes. Default setting is 2 minutes. |
(Note) This item is configurable when OS Watchdog Timer is set to Enabled.
| Parameter | Description |
| System Event Log | Press [Enter] to configure advanced items. |
| View FRU Information | Press [Enter] to view the FRU information. |
| BMC network configuration | Press [Enter] to configure advanced items. |
| IPv6 BMC Network Configuration | Press [Enter] to configure advanced items. |
2-6-1 System Event Log

| Parameter | Description |
| Enabling / Disabling Options | |
| SEL Components | Change this item to enable or disable all features of System Event Logging during boot. Options available: Disabled, Enabled. Default setting is Enabled. |
| Erasing Settings | |
| Erase SEL | Choose options for erasing SEL. Options available: No/Yes, On next reset/Yes, On every reset. Default setting is No. |
| When SEL is Full | Choose options for reactions to a full SEL. Options available: Do Nothing, Erase Immediately. Default setting is Do Nothing. |
| Custom EFI Logging Options | |
| Log EFI Status Codes | Enable/Disable the logging of EFI Status Codes (if not already converted to legacy). Options available: Disabled, Both, Error code, Progress code. Default setting is Error code. |
2-6-2 View FRU Information
The FRU page is a simple display page for basic system ID information, as well as System product information. Items on this window are non-configurable.

2-6-3 BMC Network Configuration

| Parameter | Description |
| BMC network configuration | |
| Lan Channel 1 | |
| Configuration Address source | Selects to configure LAN channel parameters statically or dynamically (DHCP). Do nothing option will not modify any BMC network parameters during BIOS phase. Options available: Unspecified, Static, DynamicBmcDhcp. Default setting is DynamicBmcDhcp. |
| Station IP address | Displays IP Address information. |
| Subnet mask | Displays Subnet Mask information. Please note that the IP address must be in three digitals, for example, 192.168.000.001. |
| Router IP address | Displays the Router IP Address information. |
| Station MAC address | Displays the MAC Address information. |
| VLAN Support | Set BMC to enable/disable VLAN support. Options available: Enabled, Disabled. Default setting is Disabled. |
| Real-time synchronize BMC network parameter values | Press [Enter] will set Address source(Static/DHCP) to BMC and then get Station IP address, Subnet mask and Router IP address from BMC. |
2-6-4 IPv6 BMC Network Configuration

| Parameter | Description |
| IPv6 BMC network configuration | |
| IPv6 BMC Lan Channel 1 | |
| IPv6 BMC Lan Option | Enable/Disable IPv6 BMC LAN channel function. When this item is disabled, the system will not modify any BMC network during BIOS phase. Options available: Unspecified, Disable, Enable. Default setting is Enable. |
| IPv6 BMC Lan IP Address Source | Selects to configure LAN channel parameters statically or dynamically (by BIOS or BMC). Options available: Unspecified, Static, Dynamic-Obtained by BMC running DHCP. Default setting is Dynamic-Obtained by BMC running DHCP. |
| IPv6 BMC Lan IP Address/ Prefix Length | Check if the IPv6 BMC LAN IP address matches those displayed on the screen. |
2-7 Security Menu
The Security menu allows you to safeguard and protect the system from unauthorized use by setting up access passwords.

There are two types of passwords that you can set:
- Administrator Password
Entering this password will allow the user to access and change all settings in the Setup Utility.
- User Password
Entering this password will restrict a user's access to the Setup menus. To enable or disable this field, a Administrator Password must first be set. A user can only access and modify the System Time, System Date, and Set User Password fields.
| Parameter | Description |
| Administrator Password | Press [Enter] to configure the administrator password. |
| User Password | Press [Enter] to configure the user password. |
| Secure Boot | Press [Enter] to configure advanced items. |
2-7-1 Secure Boot
The Secure Boot feature is applicable if supported by your Operating System. If your Operating System is not supporting Secure Boot, the system will hang when starting the Operating System.

| Parameter | Description |
| System Mode | Displays if the system is in User mode or Setup mode. |
| Secure Boot | Enable/ Disable the Secure Boot function. Options available: Enabled, Disabled. Default setting is Disabled. |
| Secure Boot Mode(Note) | Secure Boot requires all the applications that are running during the booting process to be pre-signed with valid digital certificates. This way, the system knows all files being loaded before the Operating System loads to the login screen have not been tampered with. When set to Standard, it will automatically load the Secure Boot keys form the BIOS databases. When set to Custom, you can customize the Secure Boot settings and manually load its keys from the BIOS database. Options available: Standard, Custom. Default setting is Standard. |
| Restore Factory Keys | Forces the system to user mode and installs factory default Secure Boot key database. |
| Reset To Setup Mode | Press [Enter] to reset the system mode to Setup mode. |
| Enter Audit Mode | Press [Enter] to set the system mode to audit mode. |
(Note) Advanced items prompt when this item is set to Custom.
| Parameter | Description |
| Key Management | Press [Enter] to configure advanced items.Pleases note that this item is configurable when Secure Boot Mode is set to Custom.Factory Key Provision- Allows to provision factory default Secure Boot keys when system is in Setup Mode.- Options available: Enabled, Disabled. Default setting is Disabled.Restore Factory Keys- Installs all factory default keys. It will force the system in User Mode.- Options available: Yes, No.Enroll EFI Image- Press [Enter] to enroll SHA256 hash of the binary into Authorized Signature Database (db).Secure Boot variable- Displays the current status of the variables used for secure boot Platform Key (PK)- Displays the current status of the Platform Key (PK).- Press [Enter] to configure a new PK.- Options available: Update.Key Exchange Keys (KEK)- Displays the current status of the Key Exchange Key Database (KEK).- Press [Enter] to configure a new KE or load additional KE from storage devices.- Options available: Update, AppendAuthorized Signatures (DB)- Displays the current status of the Authorized Signature Database.- Press [Enter] to configure a new DB or load additional DB from storage devices.- Options available: Update, AppendForbidden Signatures (DBX)- Displays the current status of the Forbidden Signature Database.- Press [Enter] to configure a new dbx or load additional dbx from storage devices.- Options available: Update, AppendAuthorized TimeStamps (DBT)- Displays the current status of the Authorized TimeStamps Database.- Press [Enter] to configure a new DBT or load additional DBT from storage devices.- Options available: Update, Append.OsRecovery Signatures- Displays the current status of the OsRecovery Signature Database.- Press [Enter] to configure a new OsRecovery Signature or load additional OsRecovery Signature from storage devices.- Options available: Update, Append. |
2-8 Boot Menu
The Boot menu allows you to set the drive priority during system boot-up. BIOS setup will display an error message if the legacy drive(s) specified is not bootable.

| Parameter | Description |
| Boot Configuration | |
| Setup Prompt Timeout | Number of seconds to wait for setup activation key. 65535 (0xFFFF) means indefinite waiting.Press the numeric keys to input the desired values. |
| Bootup NumLock State | Enable/Disable the Bootup NumLock functionOPTIONS available: On, Off. Default setting is On. |
| Full Screen LOGO Show | Enable/Disable showing the logo during POSTOPTIONS available: Enabled, Disabled. Default setting is Enabled. |
| Setup Flash | Press [Enter] to run setup flash. |
| Dump full Setup Data | Press [Enter] to dump full setup data to file. |
| Dump non-default Setup Data | Press [Enter] to dump non-default setup data to file. |
| Restore Setup Data | Press [Enter] to restore setup data from file (cJson format). |
| Fast Boot | Options available: Enabled, Disabled. Default setting is Disabled. |
| Boot mode select | Selects the boot modeOPTIONS available: LEGACY, UEFI. Default setting is UEFI. |
| FIXED BOOT ORDER Priorities | |
| Boot Option #1 / #2 / #3 / #4 / #5 | Press [Enter] to configure the boot priority. By default, the server searches for boot devices in the following sequence: 1. Hard drive. 2. CD-COM/DVD drive. 3. USB device. 4. Network. 5. UEFI. |
| UEFI Network Drive BBS Priorities | Press [Enter] to configure the boot priority. |
| UEFI Application Boot Priorities | Press [Enter] to configure the boot priority. |
2-9 Save & Exit Menu
The Save & Exit menu displays the various options to quit from the BIOS setup. Highlight any of the exit options then press

| Parameter | Description |
| Save Options | |
| Save Changes and Exit | Saves changes made and closes the BIOS setup. Options available: Yes, No. |
| Discard Changes and Exit | Discards changes made and exits the BIOS setup. Options available: Yes, No. |
| Save Changes | Saves changes done so far to any of the setup options. Options available: Yes, No. |
| Default Options | |
| Restore Defaults | Loads the default settings for all BIOS setup parameters. Setup Defaults are quite demanding in terms of resources consumption. If you are using low-speed memory chips or other kinds of low-performance components and you choose to load these settings, the system might not function properly. Options available: Yes, No. |
| Boot Override | Press [Enter] to configure the device as the boot-up drive. |
| Launch EFI Shell from filesystem device | Attempts to Launch EFI Shell application (Shell.efi) from one of the available file system devices. |
2-10 BIOS Recovery
The system has an embedded recovery technique. In the event that the BIOS becomes corrupt the boot block can be used to restore the BIOS to a working state. To restore your BIOS, please follow the instructions listed below:
Recovery Instruction:
- Copy the XXX.rom to USB diskette.
- Setting BIOS Recovery jump to enabled status.
- Boot into BIOS recovery.
- Run Proceed with flash update.
- BIOS updated.


2-11 BIOS POST Beep code (AMI standard)
2-11-1 PEI Beep Codes
| # of Beeps Description | |
| 1 | Memory not Installed. |
| 1 | Memory was installed twice (InstallPeiMemory routine in PEI Core called twice) |
| 2 | Recovery started |
| 3 DXEiplL was not found | |
| 3 DXE Core Firmware Volume was not found | |
| 4 Recovery failed | |
| 4 | S3 Resume failed |
| 7 | Reset PPI is not available |
2-11-2 DXE Beep Codes
| # of Beeps Description |
| 1 Invalid password |
| 4 Some of the Architectural Protocols are not available |
| 5 No Console Output Devices are found |
| 5 No Console Input Devices are found |
| 6 Flash update is failed |
| 7 Reset protocol is not available |
| 8 Platform PCI resource requirements cannot be met |