SIEMENS DE2427527M - Boiler

DE2427527M - Boiler SIEMENS - Free user manual and instructions

Find the device manual for free DE2427527M SIEMENS in PDF.

📄 24 pages English EN Download 💬 AI Question 8 questions ⚙️ Specs
Notice SIEMENS DE2427527M - page 6
Technical Features Wall-mounted gas boiler, nominal power 24 kW, high energy efficiency, class A.
Usage Central heating and domestic hot water production.
Maintenance and Repair Annual maintenance recommended, burner and water circuit check, filter cleaning.
Safety Integrated safety system, overheating protection, gas leak detection.
General Information Compact dimensions, easy installation, compatible with modern control systems.

Frequently Asked Questions - DE2427527M SIEMENS

What should I do if my SIEMENS DE2427527M boiler does not turn on?
Check if the device is properly plugged in and if the circuit breaker is in the "ON" position. Also ensure the thermostat is set to a temperature higher than the ambient temperature.
Why is my boiler making a strange noise?
Unusual noises can be caused by air bubbles in the system or limescale buildup. It is recommended to bleed the radiators and check the water condition in the system.
How do I reset my SIEMENS DE2427527M boiler?
To reset the boiler, locate the reset button on the control panel. Press this button for a few seconds until the display indicates the boiler is ready to operate.
What should I do if my boiler pressure is too low?
If the pressure is below 1 bar, you need to add water to the system using the filling valve. Consult the manual for specific filling instructions.
How do I know if my boiler needs maintenance?
It is advised to have your boiler checked at least once a year by a professional. Signs such as strange noises, unstable pressure, or error messages on the display may indicate maintenance is needed.
What should I do if my boiler display shows an error code?
Consult the user manual to identify the error code. This will inform you about the nature of the problem and the steps to resolve it.
Can I install the SIEMENS DE2427527M boiler myself?
It is strongly recommended to have the boiler installed by a qualified professional to ensure safety and proper operation.
How can I improve the energy efficiency of my boiler?
Make sure filters are clean, regularly bleed the radiators, and consider installing programmable thermostats to optimize energy consumption.

User questions about DE2427527M SIEMENS

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Boiler in PDF format for free! Find your manual DE2427527M - SIEMENS and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. DE2427527M by SIEMENS.

USER MANUAL DE2427527M SIEMENS

Operating instructions

Eine Störung, was tun?

SIEMENS DE2427527M - Eine Störung, was tun? - 1

Achtung!

This appliance is intended for domestic use and the household environment only.

Important safety information

Please read these instructions carefully, then act accordingly! Store for future reference. These instructions must be included when transferring this appliance to a new owner.

SIEMENS DE2427527M - Important safety information - 1

Risk of electric shock! Switch off the mains voltage supply immediately if a fault occurs. Immediately shut off the cold water supply to the appliance should it leak.

The installation and initial start-up must be undertaken by a specialist who complies with the enclosed installation instructions. The safety information in the installation instructions must be observed. We do not accept liability for damage resulting from failure to heed these instructions and the installation instructions.

This appliance can be used by children aged 8 years and older as well as by persons with diminished bodily, sensory or mental perception, or those who lack knowledge or experience, if they are monitored or have received instruction concerning use and comprehend the possible dangers that can result. Children may not play with the appliance. Cleaning and maintenance by the user may not be performed by unsupervised children.

  • Keep children away from the appliance.
  • Please monitor children to ensure that they do not play with the appliance.
    The mixer and the warm water pipe may be hot. Please inform and instruct children appropriately.
  • Do not use aggressive or abrasive cleaning detergents!
  • Do not use a steam cleaner.
    The appliance is only to be descaled by a suitably qualified specialist.

Congratulations on purchasing this Siemens appliance. You have acquired a top-quality product, which will give you a lot of enjoyment.

Operating instructions

Getting to know your appliance

This appliance is an electronically-regulated, pressurized continuous-flow heater for decentrally supplying hot water.

The electronic continuous-flow heater heats the water as it flows through the appliance. One or more taps can be supplied with warm water.

Operating elements and displays
SIEMENS DE2427527M - Getting to know your appliance - 1

text_image 40,0°C 1 2

1 Display
2 Rotary selector switch

Operating the appliance

Switching the appliance on and off

The continuous-flow heater switches on and heats the water when the warm water tap is opened. It switches off again if the water tap is closed.

Setting the water temperature

■ Turn the rotary selector switch. Any desired temperature can be set between 30 °C to 60 °C in increments of 0.5 °C. The display shows the selected temperature.

Note: The displayed temperature is the water temperature inside the appliance. The temperature of the water leaving the tap can vary from this due to heat losses in the pipework.

Error message in the display

If an error message "E.." appears in the display or an LED flashes, see chapter "A fault, what to do?".

Solar heated

The appliance can be operated with pre-warmed water (for example, from a solar energy unit).

SIEMENS DE2427527M - Solar heated - 1

Attention! Scalding danger!

If the output temperature of the water leaving the tap is higher than the set temperature, then this is because the supply water temperature from the domestic system is too hot, e. g. due to its being heated by a solar energy unit.

- The thermostatic premixer in the domestic supply must be set accordingly to lower temperatures.

Startup after power failure

- Open the warm water tap fully and allow water to flow until it is warm.

Using the appliance after switching off the water supply

  • Switch off the appliance (unscrew the fuse in the fusebox).
  • Open the warm water tap and keep it open until the air has been completely forced out of the water pipe.
    ■ Switch the fuse back on again.
  • Open the warm water tap fully and allow water to flow for at least one minute,

Only then (for safety reasons) will the appliance begin to heat. The appliance is now ready to operate.

Saving energy

- Set the desired water temperature directly on the appliance.

Note: Mixing in of cold water at the faucet/fitting consumes unnecessary water and energy.

This also accelerates calcification (scaling) of the appliance. Therefore, please always set the desired temperature directly on the continuous-flow heater.

Winter operation

Note: It is possible in winter that the supply temperature of the water is reduced and the required outlet temperature is no longer achieved.

- Reduce the water flow on the taps until the desired water temperature is reached.

Cleaning

■ Only wipe off the appliance using a moist cloth.
- Do not use acidic or abrasive cleaning materials.
- Do not use a steam cleaner.

Customer Service

We ask you to always provide the E-No. and the FD-No. of your appliance when calling in a customer service engineer. You will find the numbers on the ratings plate on the inner side of the front flap.

The contact information for your country can be found on the last pages of these instructions.

Environmentally-friendly disposal

■ Dispose of the packaging in an environmentally sound manner.

SIEMENS DE2427527M - Environmentally-friendly disposal - 1

This appliance is labelled in accordance with European Directive 2012/19/EU concerning used electrical and electronic appliances (waste electrical and electronic equipment – WEEE).

The guideline determines the framework for the return and recycling of used appliances as applicable throughout the EU.

Please ask your specialist retailer about current disposal facilities.

Subject to change without notice.

A fault, what to do?

SIEMENS DE2427527M - A fault, what to do? - 1

Attention!

Repairs must only be carried out by an authorised technician. Improper repairs can lead to risk of serious injury to the user.

If your appliance does not operate as required, it is often due to a very minor problem. Please check whether you can remedy the fault yourself by using the following guidelines. You will save yourself the costs of an unnecessary visit by customer service personnel.

Faults that the customer can troubleshoot himself

Fault Cause Solution
Water flow-rate is too low The filter in either the water tap or the showerhead is clogged.Remove the filter and either clean it or descale it.
A high water temperature is set, but it is not reached.The continuous-flow heater is connected to a thermostatically-controlled water tap.Set the temperature on the continuous-flow heater to „60 °C”.
The display is blank. The fuse in the fusebox has tripped/blown. Check the fuse in the fusebox.
The water is not warm. The supply temperature has reduced. Reduce the water flow on the taps until the desired water temperature is reached.
The temperature of the water leaving the tap is higher than the set temperature.The temperature of the water supplying the continuous-flow heater is higher than the set temperature (e. g. due to pre-warmed water supplied from a solar water heater).The thermostatic premixer in the domestic supply must be set accordingly to lower temperatures.
“°C” flashes in the display. The power limit has been reached. Reduce the water flow at the tap or lower the temperature setting on the appliance.

If the fault could not be eliminated, please call customer service.

Faults that the customer service specialist should troubleshoot

Fault Cause Solution
Water flow-rate is too low despite cleaning of filter using the water tap or showerheadA filter in the appliance is clogged. Get a servicing expert to clean the appliance.
The display is blank despite fault-free function of the mains electricity supply fuses.There is a fault in the appliance. Get a servicing expert to check the appliance.
The display shows the error code “E..”.There is a fault in the appliance. Get a servicing expert to check the appliance.

Faults that are automatically remedied

Fault Cause Solution
The display shows “00,0°C”. Theair sensor in the appliance detects air in the water and momentarily switches the heating element off.After a few seconds, the continuous-flow heater automatically goes back into operation.

Guarantee

The guarantee conditions for this appliance are as defined by our representative in the country in which it is sold.

Details regarding these conditions can be obtained from the dealer from whom the appliance was purchased. The bill of sale or receipt must be produced when making any claim under the terms of this guarantee.

European Trade Center Building, 5th floor 1784 Sofia

Tel.: 0700 208 18

Fax: 02 878 79 72

mailto:informacia.servis-bg@bshg.com

www.siemens-home.bg

CH Schweiz, Suisse, Svizzera, Switzer

BSH Hausgeräte AG

Central Branch Service

17 km E.O. Athinon-Lamias &

Potamou 20

14564 Kifisia

Unit 1 & 2, 3rd Floor

North Block, Skyway House

3 Sham Mong Road

Tai Kok Tsui, Kowloon

Hong Kong

Tel.: 2565 6151

Fax: 2565 6681

mailto:siemens.hk.service@bshg.com

www.siemens-home.com.hk

HR Hrvatska, Croatia

BSH kućni uređaji d.o.o.

Kneza Branimira 22

10000 Zagreb

Tel:. 01 552 09 99

Fax: 01 640 36 03

mailto:informacije.servis-hr@bshg.com

www.siemens-home.com/hr

LU Luxembourg

www.siemens-home.com/lu

ME Crna Gora, Montenegro

Elektronika komerc

UI. Slobode 17

84000 Bijelo Polje

Tel./Fax: 050 432 575

Mobil: 069 324 812

mailto:ekobosch.servis@t-com.me

MK Macedonia, Makedonija

GORENEC

Jane Sandanski 69 lok. 3

1000 Skopje

Tel.: 022 454 600

Mobil:070 697 463

mailto:gorenec@yahoo.com

PH Philippines

Häfele Philippines, Incorporated

Levi Mariano Avenue, Brgy. Ususan,

Taguig City 1632

Metro Manila

Tel.: 0842 3353

Fax: 0571 3662

mailto:siemens-home@hafele.com.ph

PL Polska, Poland

2034/1-5 Ital Thai Building,

1st Floor, New Petchburi Road

Bangkapi, Huaykwang,

Bangkok, 10310

Tel.: 02 769 7970

Fax: 02 769 7971

Service Call Center 02 351 8995

Spareparts 02 769 7975

www.siemens-home.com/th

TR Türkiye, Turkey

BSH Ev Aletleri Sanayi

ve Ticaret A. S.

Fatih Sultan Mehmet Mahallesi

Balkan Caddesi No: 51

34771 Ümraniye, Istanbul

Tel.: 0 216 444 6688*

Fax: 0 216 528 9188

mailto:careline.turkey@bshg.com

www.siemens-home.com/tr

www.siemens-homeappliances.com

9001217886

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : SIEMENS

Model : DE2427527M

Category : Boiler