EHR 202.5 S - Cement mixer Eibenstock - Free user manual and instructions
Find the device manual for free EHR 202.5 S Eibenstock in PDF.
Frequently Asked Questions - EHR 202.5 S Eibenstock
User questions about EHR 202.5 S Eibenstock
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
Download the instructions for your Cement mixer in PDF format for free! Find your manual EHR 202.5 S - Eibenstock and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. EHR 202.5 S by Eibenstock.
USER MANUAL EHR 202.5 S Eibenstock
natural_image
Green hexagonal logo with stylized letter 'E' (no text or symbols)natural_image
Black EIBENSTOCK pressure regulator device with green handle and red logo (no text or symbols on device body)EHR 20 / 2.5 S
DEUTSCH
Wichtige Hinweise
natural_image
Symbol of a trash bin crossed with diagonal lines, representing waste sorting or disposal (no text or labels)Important Instructions
Important instructions and warning notices are allegorated on the machine by means of symbols:



Before you start working, read the operating instructions of the machine.
Work concentrated and carefully. Keep your work-place clean and avoid dangerous situations.
In order to protect the user, take precautions.
During work you should wear goggles, ear protectors, dust mask, protective gloves and sturdy work clothes.




Use ear protection
Wear safety goggles
Use protective gloves
Wear a dust mask
Technical Characteristics
Stirrer EHR 20 / 2.5 S
| Rated voltage: 230 V ~ 110 V ~ | |||
| Rated power input: 1300 W 1200 W | |||
| Rated current: 6,8 A 11,5 A | |||
| Frequency: 40 - 60 Hz | |||
| No Load Speed: I | II | 400 rpm730 rpm | |
| Load Speed: I | II | 0 – 250 rpm0 – 450 rpm | |
| Max. basket diameter: 140 mm | |||
| Thread connection: M 14 | |||
| Protection class: II | |||
| Degree of protection: | IP 20 | ||
| Net weight: | about. 5,1 kg | ||
| Order number: | 07743 | ||
Interference suppression: EN 55014 and EN 61000
Available accessories:
| Item | Order No. |
| Round Stirring Rod RG 120 | 31124 |
| Helicon Ribbon Stirring Rod WG 135 | 31225 |
| Mortar Stirring Rod MG 140 | 31326 |
| Mortar Stirring Rod Stainless-Steel MGV 140 | 31426 |
| ... with M 14 Thread Connection | |
| Mixing Stand RST 91 with Reduction Rings ∅ 43 and ∅ 46 | 09403 |
Supply
Stirrer with stirring rod and operating instructions in a set box
Application for Indented Purpose
The Stirrer EHR 20 / 2.5 S is designed for use in mixing of prefab plaster, gypsum, lime, concrete and other building materials of medium and high viscosity in batches up to 50 kg.
Safety Instructions

Safe work with the machine is only possible if you read this operating instruction and the safety instructions completely and follow the instructions contained strictly. Additionally, the general safety instructions of the leaflet supplied with the tool must be observed. Prior to the first use, the user should absolve a practical training.

If the connection cable gets damaged or cut during the use, do not touch it, but instantly pull the plug out of the socket. Never use the tool with a damaged connection cable.

The tool must neither be wet nor used in humid environment.
- Do not use the tool near explosive materials (petrol, dilution).
■ Modifications of the tool are prohibited. - Always check the tool, cable and plug before use. Have damages only repaired by specialists. Only insert the plug into the socket when the tool switch is off.
- When the machine runs outside, always use a protection switch (30 mA max.) against fault current.
- The machine should only work under supervision of somebody. Plug and switch the machine off if it is not under supervision, e. g. in case of putting up and stripping down the machine, in case of setting up and striking, voltage drop or when fixing or mounting an accessory.
- Switch the machine off if it stops for whatever reason. This way, you avoid that it starts suddenly and not under supervision.
- Do not use the machine if one part of the housing is damaged or in case of damages on the switch, cable or plug.
- Electric tools have to be inspected by a specialist in regular intervals.
- Do not touch rotating parts.
- Persons under 16 years of age are not allowed to use the tool.
■ Before starting up, check that the mixing rod is securely attached and rotates without a hitch. - Do not reach into the mixing container with your hands or insert any other objects into it while mixing is in progress. Risk of crushing!
- Wait until the machine or tool comes to a complete standstill. Rotating tools can snag and cause injuries or damage.
- When working with this machine wear ear protectors, goggles, dust mask and protective gloves.




During use, always hold the machine with both hands and maintain a safe standing position. Start up and run down the machine in the mixing container only. Pay attention to the reaction moment of the machine.
For further safety instructions, please refer to the enclosure.
Electrical Connection
Before starting the machine, please check the correspondence between voltage and frequency against the data mentioned on the identification plate. Voltage differences of +6% and -10% are allowed.
The Stirrer EHR 20 / 2.5 S is made in protection class II. Only use extension cables with a sufficient cross section. A cross section which is too small could cause a considerable drop in performance and an overheating of machine and cable.
Recommended minimum cross sections and maximum cable lengths
| Mains voltage Cross section in s q. mm | ||
| 1.5 2.5 | ||
| 110V 20 m 40 m | ||
| 230V 50 m 80 m | ||
Tool Change



Attention!
Before any work on the tool, disconnect the plug from the mains!
When inserting the tool, you could catch your hands. For this reason, always wear protective gloves for changing the tool.
The work spindle of the machine has an M 14 - internal thread. Keep threads and front surface clean.
Please hold up with a jaw wrench 22 to remove the stirring rod.
Tool Protection
Wrong handling can cause damages on the tool. Therefore, the following instructions should be observed:
Only use stirring rods which have a M 14 - external thread
(diameter 140 mm max.) and are recommended by the producer.
Do not allow blocking of the tool.
Only use original accessories made by EIBENSTOCK.
Speed Selection
The machine is equipped with a mechanical two-speed gearbox. Select the required speed by pressing-in, shifting and engaging. The position of the lower speed is in direction of the working spindle. Change the speed only when the machine is not running, and support the speed-changing by slightly rotating the work spindle.
Switching on and off
Short-Time Operation
Switching-on: press the on/off switch
Switching-off: release the on/off switch
Permanent Operation
Switching-on: press the on/off switch and, keeping it pressed, engage the lock button
Switching-off: press the on/off switch and let release it again

Attention!
Use the lock button only when using a stand. In the case of any stopping of the machine or current interruption the lock-on button has to be released immediately by pressing the on/off switch, to prevent an unintentional restarting of the machine (danger of injuries)
The Stirrer EHR 23 / 2.5 S is equipped with an electronic switch. With this switch the speed can be regulated according to the pressure on the button. Only use the electronic switch when you want to start or stop the machine in order to avoid material splashing around. A permanent use with reduced speed can cause an overload because the motor then gets less cooling air and therefore the machine will be overheated much faster.
Care and Maintenance

Before the beginning of maintenance or repair works you have to disconnect the plug from the mains.
Repairs may be executed only be appropriately qualified and experienced personnel. After every repair the machine has to be inspected by an electric specialist. Due to its design, the machine needs a minimum of care and maintenance. However, the following points always have to be observed:
■ Always keep the power tool and the ventilation slots clean.
- During work, please pay attention that no particles get inside the machine.
- In case of failure, a repair has to be carried out by an authorised service workshop.
Environmental Protection

Raw Material Recycling instead of Waste Disposal
In order to avoid damages on transportation, the tool has to be delivered in solid packaging. Packaging as well as unit and accessories are made of recyclable materials and can be disposed accordingly.
The tool's plastics components are marked according to their material, which makes it possible to remove environmental friendly and differentiated because of available collection facilities.
Only for EU countries
Do not dispose of electric tools together with household waste material!

natural_image
Simple line drawing of a trash bin with crossed lines indicating no waste or restriction (no text or symbols)In observance of the European Directive 2002/96/EC on waste electrical and electronic equipment and its implementation in accordance with national law, electric tools that have reached the end of their life must be collected separately and returned to an environmentally compatible recycling facility.
Noise Emission / Vibration
The indication of noise emission is measured according to DIN 45 635, part 21. The level of acoustic pressure on the work place could exceed 85 dB (A); in this case protection measures must be taken.

Wear ear protectors!
The typical hand-arm vibration is below 2.5 m/s ^4 .
Measured values determined according to EN 60 745.
The declared vibration emission level represents the main applications of the tool. However if the tool is used for different applications, with different accessories or poorly maintained, the vibration emission may differ. This may significantly increase the exposure level over the total working period.
An estimation of the level of exposure to vibration should also take into account the times when the tool is switched off or when it is running but not actually doing
the job. This may significantly reduce the exposure level over the total working period.
Identify additional safety measures to protect the operator from the effects of vibration such as: maintain the tool and the accessories, keep the hands warm, organisation of work patterns.
Warranty
According to the general supply conditions for business dealings, suppliers have to provide to companies a warranty period of 12 months for redhibitory defects. Otherwise, the legal warranty period of 24 months applies. (to be documented by invoice or delivery note)
Damage due to natural wear, overstressing or improper handling are excluded from this warranty.
Damages due to material defects or production faults shall be eliminated free of charge by either repair or replacement.
Complaints will be accepted only if the tool was returned in non-dismantled condition to the manufacturer or an authorized Eibenstock service centre.
CE Declaration of Conformity
On sole responsibility we declare that this product is in conformity with the following standards and standard documents:
EN 60 745, EN 55 014, EN 61 000
According to the regulations 2006/95/EC, 2004/108/EC, 2006/42/EC

text_image
Handwritten signature or scribble on white background, possibly a signature or artistic marknatural_image
Simple line drawing of a trash bin with crossed lines indicating no waste or discharge (no text or symbols)2006/42/CE, 2006/95/EG, 2004/108/EG,