USER MANUAL 1U12EH1ERA HAIER
Please read this operation manual before using the air conditioner.
OPERATION MANUAL Keep this operation manual for future reference.
Parts and Functions Indoor Unit
OUTLETINLETCONNECTING PIPINGDRAIN HOSE
(If the unit which youpurchased has healthy TIMER OFF display TIMER ON displaySLEEP displayIf not,please ignore.)
status operation.the body. Outer side of the controller temp display Negative AnionInlet grilleAir Purifying FilterOutletHorizontal flapDisplayboard(adjust left and Vertical bladeEmergency Switch generator(inside)Inlet(inside)Intelligent eye Please be subject to the actual produce purchased, the above picture is just from your reference. AND ELECTRICAL WIRING(adjust up and down air flowDon’t adjust it manually)right air flow)One is ambient temp displaying ,the other is set temp displaying. The displaying temp can be changed between ambient temp and set temp by some special operation.Temp display include two displaying types.
Remove the battery cover; Load the batteries as illustrated. 2 R-03 batteries,resetting key(cylinder); Be sure that the loading is in line with the" + "/"-"; Load the battery,then put on the cover again. Loading of the battery Hint: Clock set Operation The distance between the signal transmission head and the receiver hole should be within 7m without any obstacle as well.When electronic-started type fluorescent lamp or change-over so the distance to the indoor unit should be shorter.wireless telephone is installed in the type fluorescent lamp orroom, the receiver is apt to be disturbed in receivingthe signals, Note: Press CLOCK button, "AM" or "PM" flashes. SMART
Confirm time. press CONFIRM,"AM "and "PM" stop flashing,while clock starts working.
00W, and so forth) This function unavailable on this models. Inner side of the controller
the controller normal.and the operating power of button button button clock settings.explanation.Full display or unclear display during operation indicates thebatteries have been used up.Please change batteries.If the remote controller can’t run normally during operation,please remove the batteries and reload several minutes later.Remove the batteries in case unit won’t be in usage for along period.If there are any display after taking-out,just needto press reset key.After time setting is confirmed,Each press will increase ordecrease 1min.If the buttonis kept pressed,time willchange quickly. Press “+” or “-” to set correct time. special heating set function: 10 degree heating maintaining (valuable for RS)Control the lightening and extinguishing of the indoor LED display board. The manual of how to change the default display temp:Press LIGHT buttoncontinuously for ten times, thedisplay temp on display panelcan be changed betweenambient temp and set temp. 2SMART Operation SMART SMART Defrost
SMART SOFT Under the cooling, heating and dehumidifying mode, press the smart key to enter the smart function. When the smart function is running, press the “cooling” “heating” or “dehumidifying” key to switch to the other mode, you will exit from the smart function. Under the smart running mode, when the air conditioning is running, it will automatically select cooling, heating, dehumidifying or blowing mode as The air conditioning unit can judge the indoor temperature and humidity, and make the adjustment accordingly. SMARTSMART start Press ON/OFF button, unit starts. Press SMART button“ ” is displayed on the remote controller SMART DRY SMART Control temperature SMART SMART stopsor COOL,HEAT and DRY Operation SMART Unit start.
Select operation mode.
Operation (This function is unavailable on One key can give you a comfortable some models) room! and “ ” is displayed on the display board,unit will run in SMART per the setting temperature. mode. is displayed on the remote controller and “ ” is displayed on the display board, unit will run in COOL mode. controller and “ ” is displayed on the display board, unit will run in HEAT mode. controller and “ ” is displayed on the display board, unit will run in DRY mode. 1.In DRY mode, when room temperature becomes lower
than temp.setting+2 unit will run intermittently ai 2.Remote controller can memorize each operation status. When starting it next time, just press ON/OFF button LOW speed regardless of FAN setting. and unit will run in previous status. 3Operation SMART Every time the button is pressed, temp. setting
Every time the button is pressed, temp. setting
Unit will start running to reach the temp.setting on LCD.
Press FAN SPEED button. For each press, fan speed changes as follows: Unit will run at selected fan speed. Select TEMP.setting FAN Operation Press TEMP.setting Press TEMP button. air flow horizontally will be much more helpful for a When humidity is high,condensate water might occur at air outlet if all vertical louvers are adjusted to left or right. It is advisable not to keep horizontal flap at downward position for a long time in COOLor DRY mode , SWING Operation SMART
Up and down air flow direction Left and right air flow direction For each press of “ ” button, air flow direction on remote controller displays as follows according to different operation modes: COOL/DRY: HEAT: SMART: Initial state remote controller: Initial state For each press of “ ” buttor,remote controller displays as follows: As cold air flows downward in COOL mode, adjusting otherwise, condensate water might occur. better air circulation. increases 0.5 decreases 0.5 FAN Operation LOW MED HI AUTO 4HEALTH Operation HEALTH AIRFLOW Operation Note: 1.After setting the health airflow function, the position of inlet 2.In heating, it is better to select the mode.3.In cooling, it is better to select the mode.under the high air humidity, a phenomenon falling drips of 5.Select the appropriate fan direction according to the actual Operation SMART The anion generator in the airconditioner can generate a anion in the air and also to kill sediment in the room and finally the quantity of position and Press HEALTH disappears,the operation stops. SMART The setting of 2).Press the button of health airflow Avoid the strong airflow blows The cancel of Press the button of health airflow grills of the air conditioner are opened, and the unit goes on working under the condition before thesetting of health airflow function.After stopping, the outlet grille will close automatically.AMAM lot of anion effectively balance bacteria and speed up the dust clean the air in the room. button For each press, is displayed Air conditioner starts health anion function operation.Press HEALTH button for twice press, When indoor fan motor is running, it has healthyprocess function. (It’s available under any mode)When the fan in the indoor unit does not work,the health lamp lights up, but the anion generatordoes not release anion. health airflow function 1).Press the button of health airflow, appears on the display. Avoidthe strong airflow blows direct tothe body.again,appears on the display. direct to the body. the health airflow Cannot pull direct the outlet grille by hand.Otherwise,the grille will run incorrectly. If the grilleis not run correctly, stop for a minute and then start,adjusting by remote controller. Notice: Remote controller can memorize each operationstatus. when starting it next time, just press ON/OFFbutton and unit will run in previous status. function and outlet grills is fixed.4.In cooling and dry, using the air conditioner for a long time water occurs at the outlet grille .conditions.again, both the inlet and outlet 5POWER/SOFT Operation To cancel TIMER mode Just press CANCEL button several times until TIMER let unit start or stop automatically a following times:Before you wake up in the morning,or get back from outside or after TIMER Operation SMART AUTO POWER SOFT displayed Air conditioner starts For each press, is Press POWER button again, disappears,the operation POWER Operation When you need rapid cooling, you can use this function. POWER SOFT Operation You can use this function when starts POWER function operation. For each press, is displayed Air conditioner Press SOFT button again, disappears,the operation stops. SOFT In SOFT operation mode, fan speed automati cally takes low speed of AUTO fan mode. Hints: Long period SOFT operation will cause effect of not too cool or not too warm. In COOL mode, fan speed automatically takes high speed SMART
Select your desired Remote controller: " TIMER OFF
Every time the button is pressed, decreases 1 min, if kept depressed, it will increase
Confirming your setting. After setting correct time, press CONFIRM button press CONFIRM button to confirm "
"or" OFF " on the OFF remote controller stops flashing. TIMER ON Remote controller: Remote controller: OFF TIMER ON
Operation POWER function operation. of AUTO fan mode. stops. POWER silence is needed for rest or reading. SOFT During POWER operation, in rapid COOL mode, the room will show inhomogeneous temperature distribution. Set Clock correctly before starting Timer operation.You can you fall asleep at night. mode disappears. Select your desired operation mode. Select your desired TIMER ON. will flash. TIMER OFF. will flash. time setting increases or press TIMER ON button to confirm, follow the same procedure in "Time setting for TIMER OFF " OFFTIMER ON OFF TIMER ON press TIMER OFF button to confirm, follow the same procedure in "Time setting for TIMER ON " rapidly. It can be adjusted within 24 hours. 6Before going to bed,you can simply press the SLEEP button and unit will operate in SLEEP mode and bring Comfortable SLEEP you a sound sleep. Press SLEEP Operation Mode 1 hours after SLEEP mode
SLEEP operation starts SLEEP operation stops 1 hr Rises 1
Unit stop In COOL, DRY mode 1 hr 1 hours after SLEEP mode starts,temp will become 2
SLEEP operation starts SLEEP operation stops 1 hr 1 hr 3 hrs 3 hrs Rises 1
Temp.setting Unit stop In HEAT mode Decreases 2
3.In SMART mode the machine will be in the state of timing-on,if the two modes are set up at the same time, either of their 4.When quiet sleeping function is set to 8 hours the quiet sleeping time can not be adjusted.When TIMER function is set,the quiet sleeping function can't be set TIMER function, the sleeping function will be cancelled; automatically, and the other mode will be cancelled. Power Failure Resume Function If the unit is started for the first time, the compressor Note to the power failure resume: press the sleep button ten times in five seconds and enter function after hearing four sounds.And press the sleep button ten times within five seconds and Temp.setting Approx.6hrs SMART AUTO
The unit operates in corresponding sleep mode, which adapted to the automatically selected operation mode. Operation 1.In COOL,DRY mode starts, temp.will become 1 higher than temp.setting. After by 1 further. The unit will run Temp.is higher than temp. setting so that room temperature for further 6 hours then stops won’t be too low for your sleep.
2.In HEAT mode lower than temp.setting. After another 1 hours, temp decrease by 2 further. After more another 3 hours, temp. rises by 1 further. The unit will run for further 3 hours then stops. Temp. is lower than temp. setting so that room temperature won’t be too high for your sleep.
another 1 hours, temp. rises button. up.After the sleeping function is set up,if user resets operation time is ended first ,the unit will stop will not start running unless 3 minutes have elapsed. unit will run automatically, and 3 minutes later the When the power resumes after power failure, the compressor starts running. leave this function after hearing two sounds. 7iFP Operation ECO Operation The power saving function only works under the cooling, heating or dehumidifying mode, after the power saving function is set, press the sharp, mute, sleep, or smart key to exit the power saving function. and automatically control the switch of the compressor, which may be inconsistent with the user’s setting. The power saving function is more effective after the air conditioning has been running for a long time (more than 2 hours) SMART ECO ECO SMART iFP The movement of people in the room can be sensed, which can improve the air adjustment efficiency.
Remote controller: BLANK and “ ” is displayed on the Every time the button is pressed, display changes as follows: In iFP,FOLLOW and EVADE operation mode, Press“ ”
display board, unit will unrin Detect the location of the human body, adjust the wind swing,blow the location where the body is. Detect the location of the human body,adjust the wind swing,avoid the location where the body is. Automatic adjusting with the environmental temperature, running with power saving. Operation Press iFP button “ ” is displayed on the remote controller iFP mode. When several people are located at different positions,or one person is moving in different areas, no matter whether the wind is blowing or not, the wind will automatically swing and blow to multi areas, the wind direction adjustment will be delayed, it cannot be deflected suddenly while detecting. button, the unit will not operate “ ” mode, Press “ ” button, the operation stops. The human body sensor is used to detect if the infrared ray is changing. It may be inaccurate in the following The human body keeps still (when reading or watching TV etc.) or is blocked by barriers like screen, cabinet The person is wearing very thick clothes or the person A pet is moving frequently, or the wind is blowing the curtains, or something in the room is swinging frequently. or glass. is lying or sleeping. conditions: Press ECONOMY button “ ” is displayed on the remote controller,unit will run in ECONOMY operation. Press ECONOMY button For twice press, ECONOMY disappears, the operation stops. After the power saving is set, the host machine will automatically adjust the setting temperature, 8Emergency operation and test operation
Pi Pi Operation Emergency Operation: the room temperature is below 16 C, do
Test operation: Use this switch in the test operation when It is not possible to operate in dry mode. Room temperatureOperation modeDesignatedtemperatureTimer mode Air flowABOVE 23
AUTOMATIC Test operation switch is the same as Use this operation only when the remote controller is defective or lost. When the emergency operation switch is pressed,the"Pi" sound is heard once, In this operation,the system automatically selects the operation modes,cooling tor fan or heat, according to Continue to press the test operation switch for more than 5 seconds. After you hear the "Pi" sound twice,release your finger from the switch:the cooling operation starts
Air Filter cleaning Clean the filter Attach the filter Close the inlet grille Once everytwo weeks Open the inlet grille by pulling Remove the filter Push up the filter’s center tab slightly until it is released from the stopper, and remove the filter Use a vacuum cleaner to remove dust, or wash the filter with water. After washing, dry the filter For smart Use of The Air Conditioner temperature which means the start of this operation. the room temperature. emergency switch. not use it in the normal operation. with the air flow speed "Hi". downward. completely in the shade. it upward Attach the filter correctly so that the “FRONT” indication is facing to the completely fixed behind the stopper. If the right and left filters are not front. Make sure that the filter is attached correctly, that may cause defects. 9power supply cord and so on. Do not install in the place where there is any possibility of inflammable gas leakage around the unit.3.Do not get the unit exposed to vapor or oil steam. Cautions WARNING Please call Sales/Service Shop for the Installation. Do not attempt to install the air conditioner by yourself because improper works may cause When abnormality such as burnt-small found, immediately stop the operation button andcontact sales shop. OFF Use an exclusive power sourcewith a circuit breakerENFORCEMENTConnect power supply cordto the outlet completelyUse the proper voltageDo not use power supply cord in a bundle.Take care not to damagethe power supply cord.1.Do not use power supply cord extended or connected in halfwaySTRICTENFORCEMENTSTRICTSTRICTENFORCEMENTPROHIBITION PROHIBITION PROHIBITION PROHIBITIONDo not start or stop theoperation by disconnecting the Do not channel the air flow directlyat people, especially at infants orthe aged.Do not try to repair or reconstruct by yourself.Do not use for the purpose of storage offood, art work, precise equipment,breeding, or cultivation. CAUTION Take fresh air occasionally especiallywhen gas appliance is running at thesame time.PROHIBITIONSTRICTENFORCEMENTDo not operate the switch withwet hand.PROHIBITIONPROHIBITIONPROHIBITIONPROHIBITIONPROHIBITIONDo not install the unit near a fireplaceor other heating apparatus.Check good condition of theinstallation standDo not pour water onto the unitfor cleaningPROHIBITIONDo not place animals or plants inthe direct path of the air flowDo not place any objects on orclimb on the unit.Do not place flower vase or watercontainers on the top of the unit.Do not insert objects into the air inlet or outlet.PROHIBITIONPROHIBITIONPROHIBITION STRICTENFORCEMENT WARNING electric shock, fire, water leakage. Check proper installationof the drainage securelyConnect the earthcable.earthing 10Trouble shooting NormalPerformanceinspection Noise is heard Phenomenon Cause or check points The system immediately. Smells are generated. Mist or steam are Multiple check Poor cooling When unit is stopped, it won't restart elapsed to protect the system. When the electric plug is pulled out and reinserted, the protection circuit During unit operation or at stop, a swishing or gurgling noise may (This noise is generated by refrigerant flowing in the system.) During unit operation, a cracking noise may be heard.This noise is temperature changes. Should there be a big noise from filter may be too dirty. This is because the system circulates smells from the interiorDuring COOL or DRY operation, This is due to the sudden coolingIs power plug inserted?Is there a power failure?Is fuse blownout? Is the air filter dirty? Are there any obstacles before Is temperature set correctly? Are there some doors or Is there any direct sunlight through the window during the Are there too much heat sources or too many people in the room In dry mode, fan speed can’t be changed. In DRY mode, when room temperaturesetting+2 C,unit will runregardless of FAN setting. during cooling operation? cooling operation?(Use curtain) windows left open? inlet and outlet? Normally it should be cleaned every 15 days. intermittently at LOW speed becomes lower than temp.indoor unit may blow out mist.of indoor air.air such as the smell of furniture,paint, cigarettes. air flow in unit operation, air generated by the casing expanding or shrinking because of be heard.At first 2-3 minutes after unit start, this noise is more noticeable. will work for 3 minutes to protect the air conditioner. immediately until 3 minutes have Cautions
3. If the fuse of indoor unit on PC board is
it with the type of T. 3.15A/ 250V outdoor broken,change it with the type of T.25A/250V Do not obstruct or cover the ventilation conditoner.Do not put fingers inlet/outlet and swing louver. Do not allow children to play with the air conditioner case should children be allowed to sit on the outdoor unit. The refrigerating circuit is leak-proof. 1.Applicable ambient temperature range: Specifications The machine is adaptive in following situation 11 .The power plug and connecting cable acquired the local
2. If the power supply cord is damaged, it
must be replaced manufacturer qualified person.
4. The wiring method should be in line with
5. After installation, the power plug should
6. The waste battery should be disposed
7. The appliance is not intended for use
persons without supervision. 8.Young children should be supervised with the appliance.
9. Please employ the proper power plug,
cord. 12.In order to protect the units,please turn 30 seconds later, cutting off the power.
10. A breaker should be incorporated into
13.Please don't insert any sensor on 3-way stop valve pipe Minimum:Minimum: grille of the air or any other things into the .In no or its service agent or a similar broken,please . If the fuse of standard. by young children or to ensure that th
which fit into the fixed wiring. The all-pole switch and the distance must have off the A/C first, fitting. Before asking for service, check the following first. blown out. does not restart by the change unit is infirm do not play
ower supply breaker between its two attestation. and at least
All the products are in conformity with the following European provision: - Low Voltage Directive 73/23/EEC - Low Voltage Directive 2006/95/EC -Electomagnetic CompatibilitY 89/336/EEC -Electomagnetic CompatibilitY 2004/108/EC ROHS The products are fulfilled with the requirements in the directive 2002/95/EEC of the European parliament and of council on the Restriction of the use of Certain Hazardous Substances in Electrical and Electronic Equipment (EU RoHS Directive) WEEE DISPOSAL REQUIREMENTS: Your air conditioning product is marked with this symbol.This means that electrical and electronic products shall not be mixed with unsorted household waste. Do not try to dismantle the system yourself : the dismantling of the air conditioning system, treatment of the refrigerant, of oil and of other part must be done by a qualified installer in accordance with relevant local and national legislation. Air conditioners must be treated at a specialized treatment facility for reuse, recycling and recovery. By ensuring this product is disposed of correctly, you will help to prevent potential negative consequences for the environment and humen health. Please contact the installer or local authority for more information. Battery must be removed from the remote controller and disposed of separately in accordance with relevant local and nationl legislation. EUROPEAN REGULATIONS
2UL¿FHGXUpFHSWHXUGH signal