Power Supply 120 V, 60 Hz
Tank Capacity 3.75 L (1 US gallon)
Maximum Runtime 44 hours on low setting
Humidification Output Adjustable (high/low)
Mist Type Visible cool mist
Humidification Technology Ultrasonic
Demineralization Cartridge HDC-200 (replaceable every 20 to 30 fills)
Recommended Cleaning Descaling with white vinegar, disinfection with diluted bleach
Dishwasher-Safe Parts Top housing, pump, mist nozzle, clear cover (top rack, no detergent)
Non-Dishwasher-Safe Parts Main housing, demineralization cartridge, water hose
Safety Polarized plug, do not use without cover, unplug before maintenance
Warranty 3-year limited (defects in materials and workmanship)
Compliance FCC Part 18 (ISM device)
Use Residential only
Customer Service 1-800-477-0457 (USA)
Minimum Distance from Walls 15 cm (6 inches)
Noise Level Quiet

Frequently Asked Questions - HUT-200 KAZ

How do I clean the inside of the pump?
Turn the cover counterclockwise, remove it, then clean the housing and disc with a cloth soaked in undiluted vinegar.
Which parts are dishwasher-safe?
The top housing, pump, mist nozzle, and clear cover can be washed in the top rack of the dishwasher, without detergent, on delicate or normal cycle (max 70 °C).
Can I use liquid detergent to clean the humidifier?
No, because detergent residues are difficult to remove and can damage the unit. Only the water hose can be washed with soap, but it must be rinsed thoroughly.
Can I add water treatment products?
Only products specifically designed for ultrasonic humidifiers, such as the Protec™ antimicrobial cleaning cartridge (models PC-1 or PC-2), are recommended. Use distilled water if water is hard.
Which setting is most appropriate?
Use the highest setting if the air is very dry. Once the humidity level is balanced, switch to a lower setting to maintain humidity.
Can I use the humidifier without the demineralization cartridge?
Yes, but we recommend using a cartridge to reduce white dust. If you do not use it, replace it with a dummy cartridge HUT-200-BLANK to ensure proper operation.
How often should I replace the demineralization cartridge?
Generally, every 20 to 30 fills, depending on water quality. If white dust appears around the unit, replace the cartridge.
The level indicator glows but I see no mist. What should I do?
Make sure there is water in the tank. Check that the output control is turned fully. If the problem persists, remove the nozzle and check that the nebulizer chamber contains water. Otherwise, replace the demineralization cartridge.
Why does my humidifier suddenly become noisy?
Check the water level: if low, fill the tank. Noise may also indicate that the pump has sucked in air; turn the unit off and on again to purge the air.
What are the tank capacity and runtime?
The tank has a capacity of 3.75 L (1 US gallon). The humidifier runs for up to 22 hours on high setting and up to 44 hours on low setting.

User questions about HUT-200 KAZ

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

Your email remains private: it is only used to notify you if someone answers your question.

No questions yet. Be the first to ask one.

Download the instructions for your Humidifier in PDF format for free! Find your manual HUT-200 - KAZ and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. HUT-200 by KAZ.

USER MANUAL HUT-200 KAZ

IMPORTANT SAFETY INSTRUCTIONS

READ AND SAVE THESE SAFETY INSTRUCTIONS BEFORE USING THIS HUMIDIFIER

When using electrical appliances, basic precautions should always be followed to reduce the risk of fire, electric shock, and injury to persons, including the following

  1. Always place this humidifier on a firm, flat and level surface. This humidifier may not work properly on an uneven surface.
  2. Place this humidifier in an area where it is not accessible to children.
  3. Do not place the humidifier near any heat sources such as stoves, radiators, and heaters.
  4. Do not use the humidifier outdoors.
  5. Before using the humidifier, check the power cord for any signs of damage. If the cord is found to be damaged, DO NOT USE and return the humidifier to the manufacturer under the warranty agreement for repair.
  6. This appliance has a polarized plug (one blade is wider than the other). To reduce the risk of shock, this plug is intended to fit only one way in a polarized outlet. If the plug does not fit securely in the outlet, reverse the plug. If it still does not fit, contact a qualified electrician. DO NOT attempt to defeat this safety feature.

  7. To disconnect the humidifier, first turn controls to the OFF position, then grip the plug and pull it from the wall outlet. Never pull by the cord.

  8. A loose fit between the AC outlet (receptacle) and plug may cause overheating and a distortion of the plug. Contact a qualified electrician to replace loose or worn outlet.
  9. The humidifier should always be unplugged and emptied when not in operation or while being serviced or cleaned.
  10. Never tilt or attempt to move the humidifier while it is operating or filled with water. UNPLUG the humidifier before moving.
  11. This humidifier requires regular cleaning. Refer to the CLEANING instructions provided. Never clean the humidifier in any manner other than as instructed in this manual.
  12. Do not direct moisture flow directly at individuals, walls or furniture.
  13. When a humidifier is used in a closed room or small rooms, check periodically for proper ventilation, as excessive humidity can cause condensation stains on walls.
  14. Turn the humidifier OFF if you notice moisture on the inside of your windows. For proper humidity reading use a hygrometer, which is available in many hardware and department stores, or by ordering one from the manufacturer.
  15. This product is intended for residential use only.

Honeywell Ultrasonic Humidifier

Model HUT-200 Series

Kaz, Inc.

250 Turnpike Road

Southborough, MA 01772

1-800-477-0457

KAZ HUT-200 - Honeywell Ultrasonic Humidifier - 1

This device complies with Part 18 of the FCC rules.

Warning: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.

This equipment has been tested and found to comply with the limits for Consumer ISM equipment, pursuant to Part 18 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy, and if not installed and used in accordance with the instructions, may cause harmful interference with radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio TV technician for help.

INTRODUCTION

How it Works:

The Easy to Care Ultrasonic Humidifier is designed to silently provide visible cool moisture. Water is pumped from the water reservoir through the demineralization cartridge which helps capture minerals in the water. Demineralized water flows into the misting tray where it is turned into a fine visible mist through the action of ultrasonic sound waves. The mist is then propelled into the air by a small fan providing relief from dry air.

The unique top fill design makes filling as easy as watering a plant. This unit is also equipped with a water circulating feature which indicates when refilling is needed.

KAZ HUT-200 - How it Works: - 1
Your humidifier is made up of these parts:

SETTING UP YOUR HUMIDIFIER

Remove from box

Remove packaging material. Remove and set aside instruction manual. Recycle box and packaging materials or save box for end of season storage.

To prevent water pump from shifting during transportation it has been taped to the inside of your humidifier. Remove top housing and locate the water pump in the bottom of the main housing. Remove shipping tape located on water pump and place water pump back in slot.

Make sure it is securely in place and hose is not bent or crimped or unit will not operate.

KAZ HUT-200 - Remove from box - 1
Figure 1

Placement

Select a firm, level location at least 6" (15cm) from any walls for proper airflow. Place the humidifier on a water-resistant surface, as water can damage furniture and some flooring.

Kaz will not accept responsibility for property damage caused by water spillage.

KAZ HUT-200 - Placement - 1

Filling

KAZ HUT-200 - Filling - 1
Fill pitcher or jug with up to 1 gallon of cool water.

Note: You can fill this humidifier with as much as 1 gallon of water or as little as a cup of water.

KAZ HUT-200 - Filling - 2
Pour water into the fill funnel area located on the top of the unit.

Note: Water can be added up to, but not exceed the Full line.

Indications that your humidifier needs to be refilled are:

  • Water will stop circulating over the top housing.
  • Your humidifier will start to sound louder.

OPERATING: HUT-200 Series

Power

KAZ HUT-200 - Power - 1

With the power switch in the OFF position, plug the filled humidifier into a polarized 120V outlet. DO NOT FORCE THE POLARIZED PLUG INTO THE OUTLET; It will only fit one way.

DO NOT plug in humidifier with wet hands to avoid electric shock.

Output

KAZ HUT-200 - Output - 1

Variable mist control allows you to customize your humidifier output. Turn the mist control knob to the highest setting for fast moisture and lower setting for moisture maintenance.

Mist Direction

KAZ HUT-200 - Mist Direction - 1

Direct moisture away from walls, furniture and bedding. Failure to do so could result in wetting of these items.

NOTE: DO NOT OPERATE WITH TOP COVER REMOVED. Doing so could result in water spilling from humidifier.

REPLACING DEMINERALIZATION CARTRIDGE

The demineralization cartridge should be changed every 20-30 fillings depending on your water quality. Keep in mind, depending on your water quality, you may need to change your demineralization cartridge more frequently. Indications that you should change your cartridge are white colored particles/dust settling around the base of your humidifier.

For areas of extreme hard water it is recommended that you use distilled water in your humidifier.

KAZ HUT-200 - REPLACING DEMINERALIZATION CARTRIDGE - 1

Replacement Demineralization Cartridge HDC-200 or Cartridge Q

KAZ HUT-200 - REPLACING DEMINERALIZATION CARTRIDGE - 2

With dry hands unplug humidifier and carry to kitchen or bathroom.

KAZ HUT-200 - REPLACING DEMINERALIZATION CARTRIDGE - 3

Remove top housing and set aside.

KAZ HUT-200 - REPLACING DEMINERALIZATION CARTRIDGE - 4

Remove water hose from demineralization cartridge by gently pulling and twisting. Remove old demineralization cartridge and discard.

REPLACING DEMINERALIZATION CARTRIDGE (Continued)

KAZ HUT-200 - REPLACING DEMINERALIZATION CARTRIDGE (Continued) - 1

Replace with new demineralization cartridge by gently pressing into place. You will hear a click when it is fully seated. Reattach water hose making sure it is pushed on all the way and there are no kinks.

KAZ HUT-200 - REPLACING DEMINERALIZATION CARTRIDGE (Continued) - 2

Make sure water pump is securely in place.

KAZ HUT-200 - REPLACING DEMINERALIZATION CARTRIDGE (Continued) - 3

Replace top housing.

CLEANING: HUT-200 Series

NOTE: It is recommended that all maintenance be done in the kitchen or bathroom on a water resistant surface.

Weekly Cleaning: To properly clean your humidifier we recommend the process of scale removal and disinfecting.

KAZ HUT-200 - CLEANING: HUT-200 Series - 1

KAZ HUT-200 - CLEANING: HUT-200 Series - 2
Protective Clear Cover

DISHWASHER SAFE: The following parts are TOP RACK dishwasher safe for residential dishwashers operating at temperatures below 70°C / 158°F . It is recommended that you run the dishwasher on the light duty or normal cycle. Do not wash humidifier parts with soiled articles/dishes. DO NOT USE DETERGENTS. If you use your dishwasher to clean the following parts you will not need to follow the disinfecting and scaling procedure. Please Note: Do not place parts on lower rack of dishwasher. Using the lower rack could cause damage to the humidifier parts and dishwasher.

KAZ HUT-200 - CLEANING: HUT-200 Series - 3
Top housing

KAZ HUT-200 - CLEANING: HUT-200 Series - 4
Water Pump

KAZ HUT-200 - CLEANING: HUT-200 Series - 5
Mist Nozzle

THE MAIN HOUSING, DEMINERALIZATION CARTRIDGE AND WATER HOSE ARE NOT DISHWASHER SAFE.

Placing these parts in the dishwasher will damage your humidifier and render it unable to operate properly.

KAZ HUT-200 - THE MAIN HOUSING, DEMINERALIZATION CARTRIDGE AND WATER HOSE ARE NOT DISHWASHER SAFE. - 1
Main Housing

KAZ HUT-200 - THE MAIN HOUSING, DEMINERALIZATION CARTRIDGE AND WATER HOSE ARE NOT DISHWASHER SAFE. - 2
Demineralization Cartridge

KAZ HUT-200 - THE MAIN HOUSING, DEMINERALIZATION CARTRIDGE AND WATER HOSE ARE NOT DISHWASHER SAFE. - 3
Water Hose

CLEANING: HUT-200 Series (continued)

Scale Removal directions:

KAZ HUT-200 - Scale Removal directions: - 1
Remove top housing, clear protective cover, water pump and water hose and set aside.

KAZ HUT-200 - Scale Removal directions: - 2
Remove demineralization cartridge and set aside. DO NOT WASH OR SOAK IN VINEGAR.

KAZ HUT-200 - Scale Removal directions: - 3
Empty main housing, pouring water away from rear of housing. Fill water reservoir of main housing with 2 cups vinegar.

KAZ HUT-200 - Scale Removal directions: - 4
Place pump, mist nozzle, and protective clear cover inside main housing in the vinegar solution to soak or follow the dishwasher option.

KAZ HUT-200 - Scale Removal directions: - 5
- Wash hose with soap and warm water.
- Rinse hose thoroughly until all soap residue is removed.

KAZ HUT-200 - Scale Removal directions: - 6
Gently wipe top housing and nebulizer with undiluted vinegar Note: You can place the top housing in the dishwasher if you choose.

KAZ HUT-200 - Scale Removal directions: - 7
Be sure to keep water level sensor clean.
Gently wipe with a soft cloth and undiluted vinegar.

KAZ HUT-200 - Scale Removal directions: - 8
Soak for 20 minutes. Rinse base and parts not put in dishwasher until vinegar smell is gone.
For tough stains, soak the hose in a bowl of white household vinegar for 30 minutes and rinse with warm water while flexing and crushing the soft hose to loosen any debris. Clean and wipe dry with a hand cloth.

Note: For best cleaning results hose should be soaked in the base and then rinsed with clean, cool water until the smell of vinegar is gone.

With your unit un-assembled, proceed to the disinfecting instructions.

CLEANING: HUT-200 Series (continued)

Disinfecting directions: Disinfect following scale removal

KAZ HUT-200 - Disinfecting directions: Disinfect following scale removal - 1
DO NOT DISINFECT demineralization cartridge

KAZ HUT-200 - Disinfecting directions: Disinfect following scale removal - 2
Set aside top housing, clear protective cover, water pump and water hose.

KAZ HUT-200 - Disinfecting directions: Disinfect following scale removal - 3
Add 1 TB of bleach to 1 gallon water. Add 1/2 to 3/4 gallon of water/bleach solution to water reservoir of the main housing.
NOTE: USING MORE THAN 1 TB OF BLEACH PER GALLON OF WATER WILL RESULT IN DAMAGE TO YOUR HUMIDIFIER.

KAZ HUT-200 - Disinfecting directions: Disinfect following scale removal - 4
Soak water pump, mist nozzle and clear protective cover in water reservoir of the main housing if these parts were not cleaned on the top rack of dishwasher.

KAZ HUT-200 - Disinfecting directions: Disinfect following scale removal - 5
Wipe top cover with remaining water bleach solution if these parts were not placed in dishwasher. Soak for 15-20 minutes.
Thoroughly rinse base and any parts not placed in dishwasher until the smell of bleach is gone.

Note: For best cleaning results hose should be soaked in the base and then rinsed with clean, cool water until the smell of bleach is gone.

RE-ASSEMBLING: HUT-200 Series

KAZ HUT-200 - RE-ASSEMBLING: HUT-200 Series - 1

  1. Insert pump outlet into hose and gently press all the way on until it cannot go any further.

KAZ HUT-200 - RE-ASSEMBLING: HUT-200 Series - 2

  1. Insert water pump/ hose assembly into slot in base.

Note: please be sure pump is fully seated and there are no kinks in the hose.

KAZ HUT-200 - RE-ASSEMBLING: HUT-200 Series - 3

  1. Insert demineralization cartridge into slot and gently press into place.

KAZ HUT-200 - RE-ASSEMBLING: HUT-200 Series - 4

  1. Attach water hose opening to demineralization cartridge by gently inserting cartridge outlet into water hose opening.

KAZ HUT-200 - RE-ASSEMBLING: HUT-200 Series - 5

Replace mist nozzle by gently snapping into place.

KAZ HUT-200 - RE-ASSEMBLING: HUT-200 Series - 6

Replace top housing and protective clear cover.

Note: Please be careful of clothing, rugs and other non bleach resistant materials when disinfecting. Spilling bleach on clothing, rugs and certain surfaces may cause damage.

END-OF-SEASON CARE AND STORAGE

Follow the CLEANING instructions when the humidifier will not be used for at least one week or more, or at the end of the season.

At the end of the season, remove demineralization cartridge and allow to dry properly.

Note: If demineralization cartridge has been used you should replace it with a new cartridge.

Dry the humidifier completely before storing. DO NOT store with water inside the main housing water reservoir or water tube.

Pack unit in original carton and store in a cool, dry location.

Install new demineralization cartridge before next use.

CONSUMER RELATIONS

Mail questions or comments to:

Kaz, Incorporated

Consumer Relations Dept.

250 Turnpike Road, Southborough, MA 01772

Please be sure to specify model number.

Call us toll-free at: 1-800-477-0457

E-mail: consumerrelations@kaz.com

Or visit our website at: www.kaz.com

TO ORDER REPLACEMENT PARTS

HDC-200-Demineralization Cartridge

HUT-200-Tray

HUT-200-Tray Cover

HUT-200-Mist Nozzle

750/200-Pump

HUT-200-Hose

HUT-200-BLANK

PC-1/PC-2-Protec Antimicrobial Cleaning

Cartridge

ELECTRICAL RATINGS

The Honeywell HUT-200 Series models are rated at 120V, 60 Hz.

NOTE: IF YOU EXPERIENCE A PROBLEM, PLEASE CONTACT CONSUMER RELATIONS FIRST OR SEE YOUR WARRANTY. DO NOT RETURN THE HUMIDIFIER TO THE ORIGINAL PLACE OF PURCHASE. DO NOT ATTEMPT TO OPEN THE MOTOR HOUSING OR TAMPER WITH INTERLOCK SWITCH YOURSELF, DOING SO MAY VOID YOUR WARRANTY AND CAUSE DAMAGE TO THE PRODUCT OR PERSONAL INJURY.

FREQUENTLY ASKED QUESTIONS

Cleaning

QuestionAnswer
How do I clean inside the water pump?You can clean the inside of the pump by turning the cover counter-clockwise. Remove the cover and you can clean the housing and disk.
What parts are dishwasher safe?The water hose, water pump, top housing,and protective clear cover are all top rack dishwasher safe
How do I assemble my humidifier after cleaning?See page 9 of your owners manual.
Can I use dish soap to clean my humidifier?It is not recommended that you use dish soap to clean your humidifier as it is very hard to remove all the soap and this could cause damage to your humidifier. The only part that we recommend cleaning with soap is the water hose and this part should be rinsed until all soap residue is removed.
Can I add water treatments to this humidifier?You should only add water treatments to your humidifier that are specifically made for ultrasonic humidifiers such as the ProtecTM Antimicrobial Cleaning Cartridge, model PC-1 or PC-2. Using water treatments that are not recommended for ultrasonic humidifiers could damage your humidifier. If you are concerned about hard water it is recommended you use distilled water in your humidifier.

FREQUENTLY ASKED QUESTIONS (Continued)

Operation

QuestionAnswer
What setting should I put my humidifier on?You should run your humidifier on the highest setting if your room is very dry. Once you are at a more comfortable humidity you can turn your output setting to a lower setting.
I ran my humidifier overnight in a very dry room and the humidity barely changed but my water level decreased quite a bitIt may take a few days for your humidity to increase. Wood, rugs and other objects in your room will absorb moisture before you can feel the effects, if it is extremely dry.
Can I run my humidifier without a demineralization cartridge?Yes but it is recommended that you use a demineralization cartridge to help reduce white dust. If you choose to not use a demineralization cartridge you will need to replace the demineralization cartridge in your unit with HUT-200-BLANK for it to operate. It is recommended that you use distilled water if you chose not to use a demineralization cartridge.
How often should I change my demineralization cartridge?In general the demineralization cartridge will last 20-30 fillings depending on water quality and usage. White dust on surrounding surfaces could indicate that your demineralization cartridge needs to be replaced.
How do I know my humidifier is operating properlyYou will see visible mist coming from your humidifier. Also, water will flow down the top housing and you will notice a decrease in the water level after 8 hrs of use.
The water window is illuminated but I do not see any mist coming out of the mist nozzle.Make sure unit has water. See Troubleshooting Guide for more.
There is no water running through the water flow area on the top housing.First check to make sure there is water in your humidifier. If yes, check your water pump to make sure it is properly seated in the holding area. Next check to make sure the water hose is firmly attached to both the water pump and demineralization cartridge. Last, make sure there is nothing obstructing the water flow area on the top cover or water hose. If these steps do not help, please please see our Troubleshooting Guide or contact our customer service department at 1-800-477-0457.
Why did my humidifier suddenly start sounding loud?Check your water level. If your humidifier is out of water it is an indication that you need to refill your humidifier.
How much water does my humidifier hold?Your humidifier can hold up to 1.0 Gallon of water. It can be filled to the Full line.
How long will my humidifier run when full?Your humidifier will run up to 22 hrs on high and 44 hrs on low.

TROUBLESHOOTING

1. Water is not flowing

a. Check to be sure there is water in the tank and it is covering the pump.
b. Check hose to be sure there are no kinks. Hose should be pushed fully onto both the demineralization cartridge and pump.
c. Make sure pump is fully seated properly in bottom of tank.
d. Turn unit off, then back on to help clear any air in the system.
e. If water still is not flowing, remove pump, disassemble and make sure pump wheel can spin freely and there is nothing blocking pump inlet or demineralization cartridge inlet.

2. Unit flows water but does not produce mist

a. Make sure control is rotated fully clockwise.
b. Remove mist nozzle and check to see if there is water inside the nebulizer chamber which is the pocket located next to the demineralization cartridge. If there is no water in the nebulizer chamber, you may need to replace your demineralization cartridge.
c. If there is water in the nebulizer chamber and steps 2a and 2b have been followed, you may need to call our toll free number for further instructions.

3. Pump makes a swishing sound

a. The pump may have sucked in air. Be sure there is enough water in the tank to cover the pump.
b. After filling, turn the unit off for a few seconds, then turn it back on to clear the system of air.

4. Pump makes a whirring sound

a. The pump may not be properly seated. Be sure to push pump fully into tank. After seating the pump properly, turn the unit off for a few seconds, then turn it back on.

3 YEAR LIMITED WARRANTY

You should first read all instructions before attempting to use this product.

A. This 3 year limited warranty applies to repair or replacement of product found to be defective in material or workmanship. This warranty does not apply to damage resulting from commercial, abusive, unreasonable use or supplemental damage. It also does not apply to the filter or Protec™ Antimicrobial Cartridge. Defects that are the result of normal wear and tear will not be considered manufacturing defects under this warranty.

KAZ IS NOT LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES OF ANY NATURE. ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ON THIS PRODUCT IS LIMITED IN DURATION TO THE DURATION OF THIS WARRANTY.

Some jurisdictions do not allow the exclusion or limitation of incidental or consequential damages or limitations on how long an implied warranty lasts, so the above limitations or exclusions may not apply to you. This warranty gives you specific legal rights, and you also may have other rights which vary from jurisdiction to jurisdiction. This warranty applies only to the original purchaser of this product from the original date of purchase.

B. At its option, Kaz will repair or replace this product if it is found to be defective in material or workmanship.

C. This warranty does not cover damage resulting from any unauthorized attempts to repair or from any use not in accordance with the instruction manual.
D. Return defective product to Kaz, Incorporated with a brief description of the problem. Include proof of purchase and a 10 US/ 15.50 CAN check or money order for handling, return packing and shipping charges. Please include your name, address and a daytime phone number.

You must prepay shipping charges. We suggest having tracking or delivery confirmation. Send to:

In U.S.A.:

Kaz, Incorporated

Attn: Returns Department

4755 Southpoint Drive

Memphis, TN 38118

USA

In Canada:

Kaz Canada, Inc.

Attn: Returns Department

510 Bronte Street South

Milton, ON L9T 2X6

Canada

Please go to www.kaz.com and register your product under the Customer Care Center and receive product information updates and new promotional offers.

KAZ HUT-200 - In Canada: - 1

HUMIDIFICATEUR À ULTRASONS HONEYWELL REMPLI PAR LE HAUT

MODELE DE LA SÉRIE HUT-200

IMPORTANT INSTRUCTIONS DE SECURITÉ

LIRE CES INSTRUCTIONS DE SÉCURITÉ AVANT D'UTILISER L'HUMIDIFICATEUR

Southborough, MA 01772,

ETATS-UNIS

1-800-477-0457

KAZ HUT-200 - LIRE CES INSTRUCTIONS DE SÉCURITÉ AVANT D'UTILISER L'HUMIDIFICATEUR - 1

Note: For best cleaning results hose should be soaked in the base and then rinsed with clean, cool water until the smell of vinegar is gone.

Consumer Relations Dept.

250 Turnpike Road

Southborough, MA 01772

USA

Prière de specifier le numero de modele.

Kaz, Incorporated
Attn: Returns Department
4755 Southpoint Drive
Memphis, TN 38118
USA

Au Canada:

Kaz Canada, Inc.
Attn: Returns Department
510 Bronte Street South
Milton, ON L9T 2X6
Canada

Kaz, Inc.
250 Turnpike Road
Southborough, MA 01772
1-800-477-0457

KAZ HUT-200 - Au Canada: - 1

Consumer Relations Dept.

250 Turnpike Road

Southborough, MA 01772 USA

Attn: Returns Department

4755 Southpoint Drive

Memphis, TN 38118

USA

En Canada:

Kaz Canada, Inc.

Attn: Returns Department

510 Bronte Street South

Milton, ON L9T 2X6

Canada

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : KAZ

Model : HUT-200

Category : Humidifier