Product Type UPS
Brand INFOSEC
Model IPEL EVOLUTION 1000 VA
Technology Line interactive with voltage regulation (AVR)
Waveform Pseudo sine wave
Power 1000 VA
Power Factor 0.5
Dimensions (LxWxH) 100 x 330 x 140 mm
Weight 6.5 kg
Input Voltage 110-115-120 V or 220-230-240 V
Input Voltage Range 85-140 V (low) / 162-290 V (high)
Input Frequency 45-65 Hz (auto-detection)
Output Voltage 110-115-120 V or 220-230-240 V
Battery Mode Voltage Range +/- 10%
Battery Mode Frequency 50-60 Hz +/- 1%
Battery Type Sealed lead-acid, maintenance-free
Backup Time 8 to 30 minutes (depending on load)
Recharge Time 8 hours to 90% after full discharge
Spike Protection 125 joules
Noise Level < 40 dB at 1 m
Environment 0°C to 40°C, 0-90% humidity non-condensing
LED Indicators Green (normal), Yellow (battery), Red (fault)
Audible Alarms Yes (different rhythms depending on status)
Interface USB port
Standards CE, ISO 9001, PCT
Output Connectors 3 battery-backed outlets, 1 protected outlet, 2 protected RJ11 outlets
Main Functions AVR, cold start, energy saving, automatic restart
Phone/Fax/Modem Line Protection Yes (via RJ11 IN/OUT connectors)
Package Contents Manual, power cord, 3 IEC cables, RJ11 telephone cable
Maintenance and Cleaning Unplug before cleaning, use a slightly damp cloth, no liquid or aerosol detergents
Safety Do not disassemble, do not expose to moisture, do not connect laser printers or non-IT equipment
Spare Parts and Repairability User-replaceable fuse; battery replaceable only by qualified technician

Frequently Asked Questions - IPEL EVOLUTION 1000 VA INFOSEC

How to install the IPEL EVOLUTION 1000 VA UPS?
Place the UPS in a protected area away from dust and moisture, at a temperature between 0°C and 40°C. Plug the power cord into a 2-pole + ground outlet. Connect your devices to the output outlets. Turn on the UPS by pressing the power switch.
What to do if the audible alarm sounds continuously while power is normal?
This indicates an overload. Check that the total power of connected devices does not exceed 1000 VA. Remove non-essential loads (such as a printer), then turn the UPS off and on again.
How to replace the fuse of the UPS?
Unplug the UPS from the power source. Locate the fuse on the back of the device. Replace it with a fuse of the same type (provided). Reconnect the UPS.
Why is the yellow LED on while power is present?
This may be due to a blown fuse, a poorly connected power cord, or no power. Check the fuse, reconnect the cable, and ensure the outlet is powered.
What is the backup time of the battery?
The backup time varies from 8 to 30 minutes depending on the connected load. For maximum backup time, only connect essential equipment (computer, monitor).
Can I connect a laser printer to the UPS?
No, it is not recommended to connect a laser printer because it consumes too much power and may cause an overload. Use a non-backed-up outlet or a dedicated surge protector.
How to use the cold start function?
In the absence of mains power, press and hold the power button to start the UPS on battery. Make sure the battery is sufficiently charged.
How to protect my telephone/fax/modem line?
Connect the incoming telephone line to the RJ11 jack marked IN and your device to the jack marked OUT using the provided cable. Do not use during a thunderstorm.
What to do if backup time is reduced?
Check that the UPS is not overloaded. If the batteries are discharged, connect the UPS to mains power for 24 hours to fully recharge them. If the problem persists, the batteries may be worn out and need replacement.
How to download UPSurfer Pro software?
The software is available free of charge at www.infosec.fr. It allows you to manage the UPS status and schedule automatic computer shutdown.

User questions about IPEL EVOLUTION 1000 VA INFOSEC

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Inverter in PDF format for free! Find your manual IPEL EVOLUTION 1000 VA - INFOSEC and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. IPEL EVOLUTION 1000 VA by INFOSEC.

USER MANUAL IPEL EVOLUTION 1000 VA INFOSEC

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : INFOSEC

Model : IPEL EVOLUTION 1000 VA

Category : Inverter