JHF80404B - Circuit Breaker HAGER - Free user manual and instructions

Find the device manual for free JHF80404B HAGER in PDF.

HAGER JHF80404B - Circuit Breaker
📄 10 pages English EN Download 💬 AI Question 10 questions ⚙️ Specs
Notice HAGER JHF80404B - page 4
Pick your language and provide your email: we'll send you a specifically translated version.
Product Type Miniature Circuit Breaker (MCB)
Brand HAGER
Model JHF80404B
Number of Poles 4
Rated Current (In) 80 A
Tripping Curve B
Rated Voltage (Ue) 400 V AC
Insulation Voltage 500 V
Rated Breaking Capacity 10 kA per IEC 60898-1
Mounting Type 35 mm DIN rail
Protection Degree IP20
Connection Capacity Up to 35 mm² (solid/stranded)
Tightening Torque 2.0 Nm
Mechanical Endurance 20,000 operations
Ambient Operating Temperature -25°C to +70°C
Storage Temperature -40°C to +70°C
Compliance Standards IEC/EN 60898-1
Width in Modules 4 (72 mm)
Depth 70 mm
Weight 0.5 kg
Functions Overload and short-circuit protection
Maintenance No special maintenance, periodic visual check
Safety Features Finger-safe terminals, sealed calibration
General Information Designed for residential and commercial distribution boards

Frequently Asked Questions - JHF80404B HAGER

What does the B curve in the model JHF80404B mean?
The B curve indicates that the circuit breaker will trip at instantaneous currents between 3 and 5 times the rated current (In). It is typically used for residential or lighting circuits where inrush currents are low.
Can the JHF80404B be used for three-phase applications?
Yes, the 4-pole design allows it to protect three-phase systems with a neutral, commonly used in commercial and industrial installations.
What is the maximum wire size that can be connected?
The connection capacity is up to 35 mm² for solid or stranded copper conductors. Ensure proper stripping and tightening torque of 2.0 Nm.
Is this circuit breaker suitable for DC applications?
No, the JHF80404B is designed for AC circuits only. For DC applications, use a dedicated DC circuit breaker to ensure safe operation.
What is the breaking capacity of this breaker?
It has a rated breaking capacity of 10 kA according to IEC 60898-1, meaning it can safely interrupt fault currents up to 10,000 amperes.
How do I install the JHF80404B on a DIN rail?
Simply clip the breaker onto a 35 mm DIN rail. Ensure it snaps firmly into place. Connect the incoming and outgoing conductors to the marked terminals, observing the correct torque.
What protection does the JHF80404B provide?
It provides overload protection (thermal) and short-circuit protection (magnetic). The B curve ensures fast tripping on high-fault currents.
Is there any maintenance required?
No regular maintenance is required. Periodically check for dust or moisture and verify that all connections are tight. Do not attempt to open or repair the unit; replace it if faulty.
Can the JHF80404B be used as a main switch?
While it can switch loads, it is primarily designed for overload and short-circuit protection. If used as a main switch, ensure it is not operated frequently under load.
What is the degree of protection provided by the enclosure?
The terminal faces have IP20 protection, meaning they are protected against fingers and objects larger than 12.5 mm. Installation in a suitable enclosure provides higher protection.

User questions about JHF80404B HAGER

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

Your email remains private: it is only used to notify you if someone answers your question.

No questions yet. Be the first to ask one.