VDPYCE-50M - Heat pump Vevor - Free user manual and instructions
Find the device manual for free VDPYCE-50M Vevor in PDF.
Pick your language and provide your email: we'll send you a specifically translated version.
| Device type | Heat pump (air-to-water) for swimming pools |
| Model | VDPYCE-50M |
| Brand | Vevor |
| Heating capacity | 50,000 BTU/h (approx. 14.6 kW) |
| Coefficient of performance (COP) | approx. 5.0 at air temperature 25°C and water 26°C |
| Power supply | 230 V / 50 Hz, single-phase |
| Electrical power consumption | approx. 2.9 kW |
| Refrigerant | R32 (eco-friendly) |
| Operating temperature range | from +5°C to +35°C (outdoor air) |
| Max. outlet water temperature | 35°C |
| Hydraulic connections | 2 inches (50 mm), threaded |
| Recommended water flow | 8-12 m³/h |
| Noise level | 45 dB(A) (measured at 1 m distance) |
| Dimensions (W × H × D) | 1000 × 350 × 600 mm |
| Net weight | 70 kg |
| Control | Touch panel with LCD display |
| Additional features | Optional water cooling, automatic defrost, pressure protections |
| Maintenance and cleaning | Regularly clean the filter, check the evaporator and heat exchanger; clean with low-pressure water |
| Safety | Required residual current device; grounding; overcurrent circuit breaker |
| Spare parts and service | Available from the manufacturer; repairs only by authorized service |
| General information | Designed for pools up to 50 m³; outdoor installation |
Frequently Asked Questions - VDPYCE-50M Vevor
How to install the Vevor VDPYCE-50M heat pump?
Installation should be performed by a qualified installer. Place the unit on a flat, stable surface outdoors, maintaining minimum clearances from walls. Connect the hydraulic connections (2 inches) according to the water flow direction. Grounding and a residual current device are mandatory. Detailed steps can be found in the manual.
What refrigerant is used and is it environmentally safe?
The unit uses R32 refrigerant, which has a low GWP (Global Warming Potential) compared to older refrigerants such as R410A. R32 is more eco-friendly, but it still requires proper handling and must not be released into the atmosphere.
How often should the filter and evaporator be cleaned?
Check the water filter weekly and clean it when dirty. The evaporator (air heat exchanger) should be cleaned monthly with a soft brush or a low-pressure water stream. More frequent inspections are recommended during heavy use season.
What does error code E1 on the display mean?
Error code E1 usually indicates a problem with the water or air temperature sensor. Check the sensor connections and their operation. If the error does not clear, contact service; the sensor may need to be replaced.
Can the heat pump operate in winter?
The unit has a built-in automatic defrost system, which allows operation at temperatures from +5°C. However, below this temperature, performance decreases and there is a risk of water freezing in the heat exchanger. It is recommended to turn off the pump and drain the system during frost periods.
How to connect the heat pump to the pool system?
Connect the pump before the pool filter (on the water flow). Install shut-off valves on both sides of the unit to allow servicing without draining the pool water. Make sure the flow direction matches the arrows on the coils.
What are the electrical requirements?
Power supply of 230 V / 50 Hz with overcurrent and residual current protection is required. Recommended cable cross-section is 2.5 mm². Electrical installation should be performed by a certified electrician.
What maintenance is recommended after the summer season?
At the end of the season: disconnect the power supply, drain the water from the heat exchanger, clean the evaporator and filter, check electrical and mechanical connections, and finally cover the unit with a protective tarp.
Does the unit have a cooling function?
The VDPYCE-50M model is designed for reversible operation; in cooling mode, it lowers the water temperature, which is useful in tropical climates. The function is activated from the control panel by switching the operating mode.
Where can I buy spare parts?
Spare parts can be ordered from an authorized Vevor distributor or directly through the manufacturer's website. Provide the model number (VDPYCE-50M) and the unit's serial number. Do not use non-original parts; this may void the warranty.