| Product Type | Uninterruptible Power Supply (UPS) |
| Brand | MKC |
| Model | MK-1200UPS |
| Rated Power | 1200 VA / 720 W |
| Input Voltage Range | 220–240 V AC |
| Output Voltage | 220–240 V AC |
| Battery Type | Sealed lead-acid, maintenance-free |
| Battery Voltage/Capacity | 12 V / 7–9 Ah |
| Typical Backup Time | Full load ≈ 5 minutes, half load ≈ 15 minutes |
| Charging Time | 6–8 hours to full charge |
| Number of Outlets | 4 surge-protected outlets |
| Surge Protection | Yes, built-in |
| Overload Protection | Automatic circuit breaker |
| Display / Indicators | LED status indicators (AC, battery, fault) |
| Cooling | Temperature-controlled fan |
| Noise Level | < 45 dBA at 1 meter |
| Dimensions (W × D × H) | 370 × 140 × 200 mm |
| Weight | 7.5 kg |
| Operating Temperature | 0 °C to 40 °C |
| Safety Approvals | CE, RoHS |
| Maintenance | Keep vents clean; battery replacement every 2–3 years |
| Repair / Spare Parts | User-replaceable battery; internal repairs by authorized service |
Frequently Asked Questions - MK-1200UPS MKC
How do I connect devices to the MKC MK-1200UPS?
Plug the UPS into a wall outlet, then connect your critical devices (computer, router, monitor) to the battery-backup outlets. Press the power button if needed. Avoid connecting laser printers or high-power appliances.
What is the maximum load I can connect to this UPS?
The MK-1200UPS is rated at 1200 VA / 720 W. Keep the total power draw of connected devices below 720 watts to ensure reliable backup and overload protection.
How long will the battery last during a power outage?
Typical backup time is about 5 minutes at full load and 15 minutes at half load. Actual duration depends on the efficiency of the connected equipment and battery health.
How do I replace the battery in the MK-1200UPS?
Turn off the UPS and unplug it. Open the battery compartment (usually at the bottom or side), disconnect the old battery, and replace it with a compatible 12V 7-9Ah sealed lead-acid battery. Recycle the old battery properly.
Does the UPS protect against power surges?
Yes, it includes built-in surge protection for connected devices. It shields sensitive electronics from voltage spikes and transients.
Why is my UPS beeping continuously?
A continuous beep usually indicates the battery is low, the unit is overloaded, or it is running on battery power. Check the LED indicators, reduce the load, and recharge the battery if possible.
Can I test the UPS to ensure it works?
Yes, most UPS units have a test button. Press it to simulate a power failure and verify that connected devices remain powered. You can also unplug the UPS to test battery transfer.
Can I use a generator with the MK-1200UPS?
Yes, but the generator must provide a stable and clean output (pure sine wave preferred). Avoid running the UPS from high-voltage or frequency-fluctuating generators, as it may cause transfer issues.
What maintenance does the UPS require?
Keep the unit clean and well-ventilated. Check the battery every six months and replace it every 2–3 years. Avoid exposing the UPS to extreme heat or moisture.
Will the UPS charge the battery even when powered off?
Most models, including the MK-1200UPS, charge the battery whenever the AC input is present, even if the output is switched off. This ensures the battery stays ready for the next outage.