Global Water

PL200G - Uncategorized Global Water - Free user manual and instructions

Find the device manual for free PL200G Global Water in PDF.

📄 27 pages English EN Download 💬 AI Question 10 questions ⚙️ Specs
Notice Global Water PL200G - page 2
Pick your language and provide your email: we'll send you a specifically translated version.
Product Type Submersible Pressure Level Transducer
Brand Global Water
Model PL200G (Gauge Reference)
Measurement Range 0-30 PSI (Approx. 21 m Water Head)
Accuracy ±0.25% Full Scale
Output Signal 4-20 mA Loop-Powered
Supply Voltage 10-36 VDC
Body Material 316 Stainless Steel
Cable Material Polyurethane, Ventilated Shield
Standard Cable Length 10 m (33 ft)
Diameter 0.75 inch (19 mm)
Length 4.5 inches (115 mm)
Weight 0.6 lbs (270 g)
IP Rating IP68 (Submersible to 100 m)
Operating Temperature -20°C to 60°C
Overpressure Limit 2x Rated Range
Installation Vertical Submersion, Weighted Base Recommended
Maintenance Rinse with Fresh Water, Dry, Inspect Cable
Safety Do Not Exceed Rated Pressure, Keep Vent Tube Open
Spare Parts Replacement Cables, O-rings, Vent Tubes Available
Repair Field-Repairable Modular Design
General Information Compatible with Most Data Loggers and Transmitters

Frequently Asked Questions - PL200G Global Water

How should I install the PL200G pressure level transducer?
Install the sensor in a still well or protective tube to minimize turbulence. Submerge it vertically, avoiding contact with sludge or debris. Secure the cable with clamps and ensure the vent tube remains open to the atmosphere. Do not suspend the unit by its cable alone.
How do I calibrate the PL200G?
Calibration requires a known reference pressure. Use the zero adjustment at zero pressure (sensor dry) and span adjustment at full scale. Connect a precision current meter to the 4-20 mA loop. Follow the gear's manual for specific trimmer locations.
What is the output signal of the PL200G?
The PL200G provides a standard 4-20 mA two-wire loop signal, proportional to the measured water level. The loop is powered externally; the current varies linearly between 4 mA at zero level and 20 mA at full scale.
How do I connect the sensor to a data logger or PLC?
Connect the positive supply to the red wire, the signal return to the black wire, and the shield to earth. For a 4-20 mA loop, insert a 250 Ω resistor between the black wire and ground, then measure the voltage (1-5 V) across it with a logger.
Can I lengthen or shorten the cable?
The cable is vented through the shield for gauge measurement. Shortening is possible, but lengthening should be done by an authorized technician to maintain the vent path and signal integrity. Use an IP68 splice kit for submersible connections.
How often should the sensor be cleaned and maintained?
Inspect the sensor monthly and clean it after exposure to dirty water. Rinse with fresh water and mild detergent, then dry with a soft cloth. Check the vent tube for moisture or blockages. Re-calibrate annually or after any impact.
What is the maximum submersion depth for the PL200G?
With a 0-30 psi range, the maximum depth is approximately 21 meters of fresh water. The IP68 rating allows continuous submersion, but the polyurethane cable also has a tensile limit. Avoid exceeding the pressure rating.
Why does my sensor show unstable readings?
Possible causes include electrical interference, a loose connection, moisture in the vent tube, or air bubbles trapped against the diaphragm. Check the shield grounding, clear the vent tube, and ensure the sensor is not near pump turbulence.
What is the temperature range and can it compensate for temperature?
The sensor operates from -20°C to 60°C. The pressure sensing element is temperature compensated over the full range, but the output is not user-adjustable. For accurate readings, the reference pressure must remain liquid-free.
Where can I find replacement parts for the PL200G?
Replacement parts such as cables, O-rings, and vent tubes are available from Global Water distributors. Contact official support with the serial number to order. The sensor is designed for reparability, and most parts can be field-replaced.

User questions about PL200G Global Water

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Uncategorized in PDF format for free! Find your manual PL200G - Global Water and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. PL200G by Global Water.

USER MANUAL PL200G Global Water

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : Global Water

Model : PL200G

Category : Uncategorized