Global Water

FL16 - Uncategorized Global Water - Free user manual and instructions

Find the device manual for free FL16 Global Water in PDF.

📄 37 pages English EN Download 💬 AI Question 10 questions ⚙️ Specs
Notice Global Water FL16 - page 3
Pick your language and provide your email: we'll send you a specifically translated version.
Product Type Water Flow Meter
Dimensions (H x W x D) 120 x 80 x 45 mm
Weight 0.3 kg
Power Supply 9V DC or 6x AA batteries
Flow Range 0.1 - 10 L/min
Accuracy ±1% of reading
Output Signal Pulse (NPN open collector)
Display LCD, 6-digit
Operating Temperature 0°C to 50°C
Storage Temperature -20°C to 60°C
Ingress Protection IP65
Material ABS plastic body with polycarbonate window
Battery Life Approximately 1 year (typical usage)
Functions Flow rate, totalized flow, pulse output, reset
Maintenance Clean sensor head with soft cloth; replace O-rings annually
Safety Do not exceed maximum pressure 10 bar
Spare Parts Available O-ring kit, sensor module, mounting bracket
Installation Horizontal or vertical; avoid air bubbles
Calibration Factory calibrated; field calibration possible

Frequently Asked Questions - FL16 Global Water

How do I install the FL16 flow meter?
Install the FL16 in a horizontal or vertical pipe section with straight runs of at least 10 diameters upstream and 5 downstream. Ensure the flow direction matches the arrow on the body. Tighten fittings hand-tight.
What is the battery life of the FL16?
The FL16 typically runs for about 1 year on 6 AA batteries with normal usage. Low battery indicator appears when replacement is needed.
How do I calibrate the FL16?
The FL16 comes factory calibrated. For field calibration, use the calibration mode to adjust the K-factor via the keypad. Refer to the calibration procedure in the manual.
What is the maximum pressure and temperature?
Maximum operating pressure is 10 bar (145 psi) and operating temperature range is 0°C to 50°C. Exceeding these limits may damage the device.
How do I clean the FL16 sensor?
Periodically remove the sensor head and clean gently with a soft cloth dampened with water. Avoid abrasive chemicals. Replace O-rings during annual maintenance.
What does the pulse output represent?
The pulse output provides an NPN open collector signal. Each pulse corresponds to a fixed volume of fluid (e.g., 1 pulse per liter). The K-factor is programmable.
Can the FL16 measure both flow rate and total?
Yes, the FL16 displays both instantaneous flow rate and totalized flow. The total can be reset via the keypad.
Is the FL16 suitable for potable water?
Yes, the FL16 is constructed from materials compliant with drinking water standards. It is suitable for cold potable water applications.
What does the error code E1 mean?
Error E1 indicates a sensor fault. Check the sensor connection and clean the sensor head. If persists, contact technical support.
How do I download the manual?
The manual can be downloaded for free from the notice-facile.com website. Click the download button and select your language.

User questions about FL16 Global Water

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Uncategorized in PDF format for free! Find your manual FL16 - Global Water and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. FL16 by Global Water.

USER MANUAL FL16 Global Water

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : Global Water

Model : FL16

Category : Uncategorized