AEM08FL - Air conditioner GE - Free user manual and instructions
Find the device manual for free AEM08FL GE in PDF.
| Product Type | Window Air Conditioner |
| Brand | GE |
| Model | AEM08FL |
| Cooling Capacity | 8,000 BTU |
| Recommended Room Size | Up to 350 sq ft |
| Energy Efficiency Ratio (EER) | 10.7 |
| Power Supply | 115V / 60Hz |
| Power Consumption | 750 Watts |
| Current Draw | 6.5 Amps |
| Plug Type | 3-prong grounded |
| Cooling Modes | Cool, Fan Only |
| Fan Speeds | 2 (High/Low) |
| Thermostat | Mechanical rotary control |
| Air Direction | Adjustable vertical louvres |
| Air Filter | Washable, slide-out |
| Refrigerant Type | R-32 |
| Installation Type | Window, requires minimal tools |
| Dimensions (W x H x D) | 18.2" x 12.6" x 14.9" |
| Weight | 55 lbs |
| Cord Length | 6 ft |
| Control Type | Manual dials on front panel |
| Maintenance | Washable filter, coil cleaning recommended |
Frequently Asked Questions - AEM08FL GE
User questions about AEM08FL GE
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
Download the instructions for your Air conditioner in PDF format for free! Find your manual AEM08FL - GE and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. AEM08FL by GE.
USER MANUAL AEM08FL GE
Safety Instructions .....2, 3
Operating Instructions
Control Knob Models .....6, 7
Touch Pad Models .....4, 5
Care and Cleaning
Air Filter 7
Outdoor Coils 7
Installation Instructions ...8-11
Troubleshooting Tips .....12
Normal Operating Sounds .....12
Consumer Support
Consumer Support .....14
Warranty ....13
*ENERGY STAR ® labeled product

As an ENERGY STAR® partner, GE has determined that this product meets the ENERGY STAR® guidelines for energy efficiency.
Write the model and serial numbers here:
Model #
Serial #
Find these numbers on a label on the side of the air conditioner.
Owner's Manual and Installation Instructions
AER05
AEH06
AEH08
AEM08*
IMPORTANT SAFETY INFORMATION. READ ALL INSTRUCTIONS BEFORE USING.
WARNING!
For your safety, the information in this manual must be followed to minimize the risk of fire, electric shock or personal injury.

SAFETY PRECAUTIONS
Use this appliance only for its intended purpose as described in this Owner's Manual.
This air conditioner must be properly installed in accordance with the Installation Instructions before it is used.
■ Never unplug your air conditioner by pulling on the power cord. Always grip plug firmly and pull straight out from the receptacle.
- Replace immediately all electric service cords that have become frayed or otherwise damaged. A damaged power supply cord must be replaced with a new power supply cord obtained from the manufacturer and not repaired. Do not use a cord that shows cracks or abrasion damage along its length or at either the plug or connector end.
■ Turn the unit OFF and unplug your air conditioner before cleaning.
■ GE does not support any servicing of the air conditioner. We strongly recommend that you do not attempt to service the air conditioner yourself.
For your safety...do not store or use combustible materials, gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance.
All air conditioners contain refrigerants, which under federal law must be removed prior to product disposal. If you are getting rid of an old product with refrigerants, check with the company handling disposal about what to do.
If the receptacle does not match the plug, the receptacle must be changed out by a qualified electrician.

HOW TO CONNECT ELECTRICITY
Do not, under any circumstances, cut or remove the third (ground) prong from the power cord. For personal safety, this appliance must be properly grounded.
DO NOT use an adapter plug with this appliance.
The power cord of this appliance is equipped with a 3-prong (grounding) plug which mates with a standard 3-prong (grounding) wall outlet to minimize the possibility of electric shock hazard from this appliance.
Power cord includes a current interrupter device. A test and reset button is provided on the plug case. The device should be tested on a periodic basis by first pressing the TEST button and then the RESET button while plugged into the outlet. If the TEST button does not trip or if the RESET button will not stay engaged, discontinue use of the air conditioner and contact a qualified service technician.
Have the wall outlet and circuit checked by a qualified electrician to make sure the outlet is properly grounded.
Where a 2-prong wall outlet is encountered, it is your personal responsibility and obligation to have it replaced with a properly grounded 3-prong wall outlet.
The air conditioner should always be plugged into its own individual electrical outlet which has a voltage rating that matches the rating plate.
This provides the best performance and also prevents overloading house wiring circuits which could cause a fire hazard from overheated wires.
See the Installation Instructions, Electrical Requirements section for specific electrical connection requirements.
⚠ WARNING!
USE OF EXTENSION CORDS—115-Volt models only

Because of potential safety hazards under certain conditions, we strongly recommend against the use of an extension cord.
However, if you must use an extension cord, it is absolutely necessary that it be a UL-listed, 14 gauge, 3-wire grounding type appliance extension cord having a grounding type plug and outlet and that the electrical rating of the cord be 15 amperes (minimum) and 125 volts.
▲ CAUTION:
DO NOT use an extension cord with any of the 230/208 volt models.

READ AND FOLLOW THIS SAFETY INFORMATION CAREFULLY.
SAVE THESE INSTRUCTIONS
About the controls on the air conditioner—models with touch pads.
Lights next to the touch pads on the air conditioner control panel indicate the selected settings.

Air Conditioner Controls

Remote Control

Controls
1 Power Pad
Turns air conditioner on and off. When turned on, the display will show the room temperature.
2 Display
Shows the room temperature or time remaining on the Delay timer. Shows the Set temperature while setting the temperature in Cool or Energy Saver modes. The Set light will turn on while setting.
NOTE: The display will change to show the room temperature after settings have been made. To recall the Set temperature, press the Temp Increase ▲ or Decrease ▼ pads.
3 Temp Increase ▲ /Decrease ▼ Pads
Use to set temperature when in Coolor Energy Saver mode. The Set light will turn on while setting.
4 Delay Timer Increase ▲ (+) / Decrease ▼ (−) Pads
Each touch of the Increase ▲ / Decrease ▼ pads on the unit or the Increase + / Decrease - pads on the remote control will set the delay time when using the Delay 1–24hr timer ( Ⓤ The Set light will turn on while setting.
5 Fan Speed Pads
Use to set the fan speed to Low, Med, High or Auto on the unit. NOTE: On the remote control, use the fan speed Increase + / Decrease – pads to set the fan speeds to Low, Med or High. Use the Auto pad to turn Auto fan on.
6 Mode Pad Use to set t
Use to set the air conditioner to Cool, Energy Saver or Fan Only mode.
7 Delay Pads
Delay ON—When the air conditioner is off, it can be set to automatically come on in 1 to 24 hours at its previous mode and fan settings.
Delay OFF—When the air conditioner is on, it can be set to automatically turn off in 1 to 24 hours.
How to set:
Press the Delay 1–24hr pad on the unit or the pad on the remote control. Each touch of the Increase ▲ / Decrease ▼ pads on the unit or the Increase + / Decrease- pads on the remote control will set the timer in 1-hour intervals. The Set light will turn on while setting.
To review the remaining time on the Delay 1–24hr timer, press the Delay 1–24hr pad on the unit or the pad on the remote control. Use the Increase ▲ / Decrease ▼ pads on the unit or the Increase + / Decrease – pads on the remote control to set a new time if desired.
To cancel the timer, press the Delay 1–24hr pad until the light on the Delay 1–24hr pad goes off.
Do Not Operate in Freezing Outdoor Conditions
This cool-only air conditioner was not designed for freezing outdoor conditions. It must not be used in freezing outdoor conditions.
Remote Control
To ensure proper operation, aim the remote control at the signal receiver on the air conditioner.
The remote control signal has a range of up to 20 feet.
■ Make sure nothing is between the air conditioner and the remote control that could block the signal.
■ Make sure batteries are fresh and installed correctly as indicated on the remote control.
Cool Mode
Use the Cool mode at Low, Med, High or Auto Fan Speed for cooling. Use the Temperature Increase ▲ / Decrease ▼ pads to set the desired temperature between 64°F and 86°F in 1°F increments.
An electronic thermostat is used to maintain the room temperature. The compressor will cycle on and off to keep the room at the set level of comfort. Set the thermostat at a lower number and the indoor air will become cooler. Set the thermostat at a higher number and the indoor air will become warmer.
NOTE: If the air conditioner is off and is then turned on while set to a Cool setting or if turned from a fan setting to a Cool setting, it may take approximately 3 minutes for the compressor to start and cooling to begin.
Cooling Descriptions
For Normal Cooling—Select the Cool mode and High or Med fan with a middle set temperature.
For Maximum Cooling—Select the Cool mode and High fan with a lower set temperature.
For Quieter & Nighttime Cooling—Select the Cool mode and Low fan with a middle set temperature.
Energy Saver Mode
Controls the fan.
ON—The fan will cycle on and off with the compressor. This results in wider variations of room temperature and humidity. Normally used when the room is unoccupied. NOTE: The fan may continue to run for a short time after the compressor cycles off.
OFF—The fan runs all the time, while the compressor cycles on and off.
Fan Only Mode
Use the Fan Only Mode at Low, Med or High fan speed to provide air circulation and filtering without cooling. Since fan only settings do not provide cooling, a Set temperature cannot be entered. The room temperature will appear in the display.
NOTE: Auto Fan Speed cannot be used when in the Fan Only Mode.
Auto Fan Speed
Set to Auto fan speed for the fan speed to automatically set to the speed needed to provide optimum comfort settings with the set temperature. If the room needs more cooling, the fan speed will automatically increase. If the room needs less cooling, the fan speed will automatically decrease.
NOTE: Auto Fan Speed cannot be used when in the Fan Only Mode.
Power Outage Recovery Feature
In the case of a power outage or interruption, the unit will automatically re-start in the settings last used after the power is restored. If the Delay 1–24hr
feature was set, it will resume countdown. You may need to set a new time if desired.
About the controls on the air conditioner—models with control knobs.
Features and appearance will vary.


⑦ MODE CONTROL TEMPERATURE CONTROL

Controls
1 Mode Control
High Cool, Med Cool and Low Cool
provide cooling with different fan speeds.
Fan settings provide air circulation and filtering without cooling.
NOTE: If you move the mode control from a cool setting to OFF or to a fan setting, wait at least 3 minutes before switching back to a cool setting.
Cooling Descriptions
For Normal Cooling—Select High Cool or Med Cool with the TEMPERATURE control at midpoint.
For Maximum Cooling—Select High Cool with the TEMPERATURE control at the highest number available on your knob.
For Quieter & Nighttime Cooling—Select Low Cool with the TEMPERATURE control at midpoint.
2 TEMP Control
The TEMP control is used to maintain the room temperature. The compressor will cycle on and off to keep the room at the same level of comfort. When you turn the knob to a higher number, the indoor air will become cooler. Turn the knob to a lower number and the indoor air will become warmer.
Additional important information.
Air Direction
Use the lever to adjust the air direction left and right only.

Care and cleaning of the air conditioner.
Grille and Case
Turn the air conditioner off and remove the plug from the wall outlet before cleaning.
To clean, use water and a mild detergent. Do not use bleach or abrasives.
Air Filter
The air filter behind the front grille should be checked and cleaned at least every 30 days or more often if necessary.
To remove:
Push on one side of the filter edge and pull it out the other side.
Clean the filter with warm, soapy water. Rinse and let the filter dry before replacing it. Do not clean the filter in a dishwasher.

▲ CAUTION:DO NOT operate the air conditioner without a filter because dirt and lint will clog it and reduce performance.
Outdoor Coils
The coils on the outdoor side of the air conditioner should be checked regularly. If they are clogged with dirt or soot, they may be professionally cleaned.

How to Insert the Batteries in the Remote Control
1 Remove the battery cover by sliding it according to the arrow direction.
2 Insert new batteries, making sure that the (+) and (−) of battery are installed correctly.
3 Reattach the cover by sliding it back into position.
NOTES:
Use 2 "AAA" (1.5 volt) alkaline batteries. Do not use rechargeable batteries.
■ Remove the batteries from the remote control if the system is not going to be used for a long time.
Installation Instructions
Air Conditioner

Questions? Call 800.GE.CARES (800.432.2737) or Visit our Website at: ge.com

BEFORE YOU BEGIN
Read these instructions completely and carefully.
- IMPORTANT — Save these instructions for local inspector's use.
• IMPORTANT — Observe all governing codes and ordinances. - Note to Installer – Be sure to leave these instructions with the Consumer.
- Note to Consumer – Keep these instructions for future reference.
- Skill level – Installation of this appliance requires basic mechanical skills.
- Completion time – Approximately 1 hour
- We recommend that two people install this product.
- Proper installation is the responsibility of the installer.
- Product failure due to improper installation is not covered under the Warranty.
- You MUST use all supplied parts and use proper installation procedures as described in these instructions when installing this air conditioner.

ELECTRICAL REQUIREMENTS

Some models require a 115/120-volt AC, 60 Hz grounded outlet protected with a 15-amp time delay fuse or circuit breaker.
The 3-prong grounding plug minimizes the possibility of electric shock hazard. If the wall outlet you plan to use is only a 2-prong outlet, it is your responsibility to have it replaced with a properly grounded 3-prong wall outlet.

Some models require 230/208-volt AC, protected with a time delay fuse or circuit breaker. These models should be installed on their own single branch circuit for best performance and to prevent overloading house or apartment wiring circuits, which could cause a possible fire hazard from overheating wires.
▲CAUTION:
Do not, under any circumstances, cut or remove the third (ground) prong from the power cord.
Do not change the plug on the power cord of this air conditioner.
Aluminum house wiring may present special problems—consult a qualified electrician.
TOOLS YOU WILL NEED

Phillips head screwdriver

Flat-blade screwdriver


Ruler or tape measurePencil

Level

Scissors or knife
Power cord includes a current interrupter device. A test and reset button is provided on the plug case. The device should be tested on a periodic basis by first pressing the TEST button and then the RESET button while plugged into the outlet. If the TEST button does not trip or if the RESET button will not stay engaged, discontinue use of the air conditioner and contact a qualified service technician.

① WINDOW REQUIREMENTS
• These instructions are for a standard double-hung window. You will need to modify them for other types of windows.
- The air conditioner can be installed without the accordion panels if needed to fit in a narrow window. See the window opening dimensions.
- All supporting parts must be secured to firm wood, masonry or metal.
- The electrical outlet must be within reach of the power cord.
- Follow the dimensions in the table and illustration for your model.
| Models A B | ||
| AER05, AEH06 | 13" min. | 24 1/2"-38 1/8" |
| AEH08, AEM08 | 13 5/8" min. | 24 1/2"-38 1/8" |

② STORM WINDOW REQUIREMENTS
A storm window frame will not allow the air conditioner to tilt toward the outside, and will keep it from draining properly. To adjust for this, attach a piece of wood to the sill.
WOOD PIECES -
WIDTH: 2"
LENGTH: Long enough to fit inside the window frame.
THICKNESS: To determine the thickness, place a piece of wood on the sill to make it 1/2" higher than the top of the storm window frame or the vinyl frame.
Attach securely with nails or screws provided by the installer.

③ PREPARE THE AIR CONDITIONER
A Install the top mounting rail with 3 Type B screws from the outside of the case.

B Slide the left and right accordion panels into the top and bottom mounting rails.

③ PREPARE THE AIR CONDITIONER (cont.)
C Attach the accordion panels to the case using 3 Type A screws on each side.

④ PREPARE THE WINDOW
Cut the window sash seal to the proper length. Peel off the backing and attach the seal to the underside of the window sash.

⑤ INSTALL THE AIR CONDITIONER IN THE WINDOW
A Place the air conditioner on the sill with the bottom mounting rail against its back edge. Center it and close the window securely behind the top mounting rail. It should be level or slightly tilted to the outside. Use a level; about a 1/3 bubble will be the correct case slant to the outside.

B Extend the left and right accordion panels to the vertical window sashes and attach, through the holes in the panels, with 4 Type C screws, as appropriate.
6 INSTALL A SUPPORT BRACKET AND THE FOAM TOP WINDOW GASKET
A Attach the support bracket with one Type C screw.

B Cut the foam top window gasket to the window width.
C Stuff the foam between the glass and the window to prevent air and insects from getting into the room.

Troubleshooting Tips.
| Problem Possible Causes What To Do | ||
| Air conditioner does not start | The air conditioner is unplugged. completely into the outlet. | Make sure the air conditioner plug is pushed |
| The fuse is blown/circuit breaker is tripped. the fuse or reset the breaker. | Check the house fuse/circuit breaker box and replace the breaker. | |
| Power failure. | The unit will automatically re-start in the settings last used after the power is restored.There is a protective time delay (approximately 3 minutes) to prevent tripping of the compressor overload. For this reason, the unit may not start normal cooling for 3 minutes after it is turned back on. | |
| The current interrupter • Press the device is tripped. | RESETbutton located on the power cord plug.If the RESETbutton will not stay engaged, discontinue use of the air conditioner and contact a qualified service technician. | |
| Air conditioner does not cool as it should | Airflow is restricted. | Make sure there are no curtains, blinds or furniture blocking the front of the air conditioner. |
| The temp control may • On models with touch pads: In the Decrease ▼ pad. | Cool mode, press the | |
| • On models with control knobs, turn the temperature knob to a higher number. | ||
| The air filter is dirty. | Clean the filter at least every 30 days.See the Care and Cleaning section. | |
| The room may have been hot. | When the air conditioner is first turned on, you need to allow time for the room to cool down. | |
| Cold air is escaping. | Check for open furnace registers and cold air returns. | |
| Cooling coils have iced up. | See “Air conditioner freezing up” below. | |
| Air conditioner freezing up | Ice blocks the air flow and stops the air conditioner from cooling the room. | On models with control knobs, set the mode control at High Fan or High Cool with the Temp at 1 or 2.On models with touch pads, set the controls at High Fan or High Cool and set the thermostat to a higher temperature. |
| The remote control is not working | The batteries are inserted incorrectly. | Check the position of the batteries. They should be inserted in the opposite (+) and (-) direction. |
| The batteries may be dead. | Replace the batteries. | |
| Water drips outside | Hot, humid weather. | This is normal. |
| Water drips indoors | The air conditioner is not tilted to the outside. | For proper water disposal, make sure the air conditioner slants slightly from the case front to the rear. |
| Water collects in base pan | Moisture removed from air and drains into base pan. | This is normal for a short period in areas with little humidity; normal for a longer period in very humid areas. |
Normal Operating Sounds
- You may hear a pinging noise caused by water being picked up and thrown against the condenser on rainy days or when the humidity is high. This design feature helps remove moisture and improve efficiency.
- You may hear the thermostat click when the compressor cycles on and off.
Water will collect in the base pan during high humidity or on rainy days. The water may overflow and drip from the outdoor side of the unit. The fan may run even when the compressor does not.
GE Air Conditioner Warranty—One Year Limited Warranty.

Staple your receipt here.
Proof of the original purchase date
is needed to make a warranty claim.
For The Period Of: We Will Replace:
One Year Replacement unit
From the date of the original purchase
for any product which fails due to a defect in materials or workmanship.
The exchange unit is warranted for the remainder of your product's original one-year warranty period.
In Order to Make a Warranty Claim:
Properly pack your unit. We recommend using the original carton and packing materials.
Return the product to the retail location where it was purchased.
Include in the package a copy of the sales receipt or other evidence of date of original purchase. Also print your name and address and a description of the defect.
What Is Not Covered:
Customer instruction. This owner's manual provides information regarding operating instructions and user controls.
Improper installation. If you have an installation problem, or if the air conditioner is of improper cooling capacity for the intended use, contact your dealer or installer. You are responsible for providing adequate electrical connecting facilities.
Failure of the product resulting from modifications to the product or due to unreasonable use including failure to provide reasonable and necessary maintenance.
■ Replacement of house fuses or resetting of circuit breakers.
■ Damage to the product caused by improper power supply voltage, accident, fire, floods or acts of God.
■Incidental or consequential damage caused by possible defects with this air conditioner.
EXCLUSION OF IMPLIED WARRANTIES—Your sole and exclusive remedy is product exchange as provided in this Limited Warranty. Any implied warranties, including the implied warranties of merchantability or fitness for a particular purpose, are limited to one year or the shortest period allowed by law.
This warranty is extended to the original purchaser and any succeeding owner for products purchased for home use within the USA.
Some states do not allow the exclusion or limitation of incidental or consequential damages. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. To know what your legal rights are, consult your local or state consumer affairs office or your state's Attorney General.
Exclusion of implied warranties: Except where prohibited or restricted by law, there are no warranties, whether express, oral or statutory which extend beyond the description on the face hereof, including specifically the implied warranties of merchantability or fitness for a particular purpose.
Warrantor: General Electric Company. Louisville, KY 40225

GE Appliances Website
ge.com
Have a question or need assistance with your appliance? Try the GE Appliances Website any day of the year! For greater convenience and faster service, you can now download Owner's Manuals, order parts or even schedule service on-line.

Real Life Design Studio ge.com
GE supports the Universal Design concept—products, services and environments that can be used by people of all ages, sizes and capabilities. We recognize the need to design for a wide range of physical and mental abilities and impairments. For details of GE's Universal Design applications, including kitchen design ideas for people with disabilities, check out our Website today. For the hearing impaired, please call 800.TDD.GEAC (800.833.4322).

Parts and Accessories ge.com
Individuals qualified to service their own appliances can have parts or accessories sent directly to their homes (VISA, MasterCard and Discover cards are accepted). Order on-line today, 24 hours every day or by phone at 800.626.2002 during normal business hours.
Instructions contained in this manual cover procedures to be performed by any user. GE does not support any servicing of the air conditioner. We strongly recommend that you do not attempt to service the air conditioner yourself.

Contact Us ge.com
If you are not satisfied with the service you receive from GE, contact us on our Website with all the details including your phone number, or write to: General Manager, Customer Relations
GE Appliances, Appliance Park
Louisville, KY 40225

Tipo A (6)

⑥ INSTALE UN SOPORTE DE CIERRE Y LA JUNTA DE ESPUMA SUPERIOR DE LA VENTANA
Garante: General Electric Company. Louisville, KY 40225

General Manager, Customer Relations
GE Appliances, Appliance Park
Louisville, KY 40225