| Product type | Digital clamp meter |
| Measurement functions | AC current, AC voltage, DC voltage, resistance, continuity, frequency |
| Bluetooth connectivity | Yes, range up to 10 m |
| Display | LCD with backlight, 4000 counts |
| Maximum current measurement | 1000 A AC |
| Maximum voltage measurement | 600 V AC/DC |
| Continuity buzzer | Yes, threshold 50 Ω |
| Sample rate | 2 times per second |
| Auto power off | Yes, after 15 minutes of inactivity |
| Battery type | 2 × 1.5 V AAA alkaline batteries |
| Battery life | Approximately 200 hours without backlight |
| Dimensions | 248 × 78 × 43 mm |
| Weight | 220 g including batteries |
| Operating temperature | 0 °C to 50 °C, relative humidity up to 85% |
| Storage temperature | -20 °C to 60 °C without batteries |
| Safety rating | CAT III 600 V, EN 61010-1 compliant |
| Maintenance and cleaning | Wipe with a soft dry cloth; do not use solvents or abrasives |
| Spare parts and reparability | Batteries user-replaceable; internal repair only by qualified personnel |
| General information | Bluetooth pairing with Kyoritsu mobile app for data logging |
Frequently Asked Questions - KEW 5204BT Kyoritsu
How do I measure AC current with the KEW 5204BT?
Set the rotary switch to the current mode. Ensure the conductor is inside the clamp and not the clamp jaw. The device then displays the AC current value. For accurate results, avoid external magnetic fields and keep the clamp centered around the conductor.
Can I measure two wires at once?
No, you should only place one conductor inside the clamp. Measuring two wires at once may give a sum or difference current reading, which can be dangerous and produce incorrect results.
What is the Bluetooth function used for?
The Bluetooth feature allows you to connect the KEW 5204BT to a smartphone or tablet using the Kyoritsu app. This enables remote monitoring, data logging, and trend analysis of electrical measurements.
How do I replace the batteries?
Turn off the meter and remove the screws on the battery cover. Open the cover, remove the old batteries, and insert two new AAA 1.5V batteries with the correct polarity. Close the cover and tighten the screws before use.
What safety precautions should I follow when using this clamp meter?
Always observe the CAT III 600V rating. Do not measure circuits with voltage exceeding 600V. Keep fingers behind the protective barrier, and inspect the test leads and clamp for damage before use. Never use the meter without its battery cover properly installed.
How often does the KEW 5204BT need calibration?
For optimal accuracy, it is recommended to have the meter calibrated every year or as specified by your quality system. Calibration should be performed by an authorized Kyoritsu service center.
What is the difference between KEW 5204 and KEW 5204BT?
The KEW 5204BT includes Bluetooth connectivity, allowing wireless data transmission to a mobile device. The standard KEW 5204 is the non-Bluetooth version without this wireless capability.
Can I measure DC current with this meter?
The KEW 5204BT primarily measures AC current; it is not designed for DC current measurement. For DC current, you would need a different clamp meter that supports the DC current input. Refer to the specifications for exact measurement ranges.
How do I measure resistance and continuity?
Connect the test leads to the meter, set the rotary switch to the resistance (Ω) mode. For continuity, engage the continuity mode; the meter will sound a buzzer when the resistance is below about 50 Ω. Ensure the circuit is de-energized before measuring resistance.
What should I do if the display shows 'OL'?
The overload indication 'OL' means the input exceeds the measuring range. Remove the test leads or clamp from the circuit immediately to avoid damage, and select a higher range if available or use a different meter with a higher capacity.