| Product Type | Switched Rack PDU (Power Distribution Unit) |
| Brand | APC by Schneider Electric |
| Model | AP7898 |
| Mounting | 1U 19-inch rack mount |
| Input Voltage | 120 V AC |
| Maximum Input Current | 30 A |
| Maximum Power Capacity | 3.6 kW |
| Input Plug | NEMA L5-30P |
| Number of Outlets | 8 |
| Output Socket Type | NEMA 5-20R |
| Outlet Switching | Individual remote switching |
| Network Management | Web, SNMP, Telnet, SSH |
| LED Indicators | Power, current load, overload |
| Overload Protection | Built-in circuit breaker |
| Power Cord Length | 3.05 m (10 ft) |
| Dimensions (H x W x D) | 4.4 cm x 48.3 cm x 24.1 cm (approx) |
| Weight | 3.6 kg (8 lb) |
| Operating Temperature | 0–45 °C |
| Humidity Range | 0–95% non-condensing |
| Certifications | cULus, CE, RoHS |
| Maintenance | Wipe with soft dry cloth; disconnect before cleaning |
| Safety | Connect only to grounded outlet; avoid overloading |
| Spare Parts | Replaceable power cord and fuses; contact APC support |
Frequently Asked Questions - AP7898 APC
What is the APC AP7898?
The APC AP7898 is a switched rack PDU that provides remote power management for data center equipment. It features eight NEMA 5-20R outlets and supports network monitoring and control.
How do I mount the AP7898 in a rack?
Use the included mounting brackets to install the 1U unit in a standard 19-inch rack. Secure it at both the front and rear for stability, ensuring the intake and exhaust vents are not blocked.
Can I switch outlets on/off remotely?
Yes, each outlet can be individually controlled via the built-in web interface, SNMP, or CLI. This allows you to reboot devices remotely, cycle power, and manage load shedding.
What is the maximum power I can draw?
At 120 V, the AP7898 can deliver up to 30 A and 3.6 kW total. Always verify that the combined load of connected devices does not exceed this limit to prevent overloading.
What types of plugs does it accept?
The input is a NEMA L5-30P twist-lock plug, and the outputs are eight NEMA 5-20R receptacles. These are standard for 120 V AC devices in North America.
Does it need a network connection to operate?
For remote monitoring and switching, connect the Ethernet port to your network. However, basic power distribution is electrostatic even without a network connection.
How can I monitor power usage?
The PDU supports network management protocols. You can view current draw, voltage, and power consumption through the web interface or by integrating with SNMP management software.
What safety precautions should I follow?
Connect the unit only to a properly grounded AC outlet, avoid overloading the circuit, keep the unit away from moisture, and disconnect power before any cleaning or maintenance.
How do I clean and maintain the AP7898?
Unplug the unit, then wipe the exterior with a soft dry cloth. Do not use liquids or solvents. Periodically inspect the power cord and plugs for damage and ensure vents remain free of dust.
What is the warranty period?
APC provides a standard 2-year warranty for this PDU model. It covers defects in materials and workmanship under normal use. For extended coverage, contact APC support.
User questions about AP7898 APC
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
No questions yet. Be the first to ask one.
Download the instructions for your Power Strip in PDF format for free! Find your manual AP7898 - APC and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. AP7898 by APC.