| Product Type | Water Heater |
| Brand | Fagor |
| Model | FA-24 B |
| Energy Source | Electric |
| Capacity | 24 liters |
| Power Consumption | 2000 W |
| Supply Voltage | 220-240 V ~ 50/60 Hz |
| Temperature Range | 35°C - 75°C |
| Dimensions (H x W x D) | 490 x 340 x 340 mm |
| Weight | 15 kg |
| Installation Type | Wall-mounted, vertical |
| Safety Features | Thermostat, pressure relief valve, overheat protection |
| Control Type | Manual dial with indicator light |
| Material | Enameled steel tank with glass lining |
| Color | White |
| Warranty | 2 years |
| Included Accessories | Safety valve, mounting bracket, instruction manual |
| Maintenance | Annual descaling and anode rod check |
| Certifications | CE, RoHS |
| Country of Origin | Spain |
Frequently Asked Questions - FA-24 B FAGOR
How do I install the Fagor FA-24 B water heater?
Installation must be performed by a qualified professional. The unit should be mounted vertically on a solid wall with the provided bracket. Connect to cold water supply with a pressure relief valve. Electrical connection requires a dedicated circuit with proper grounding. Refer to the manual for detailed steps.
How do I adjust the water temperature?
Turn the thermostat dial located at the front of the unit. The temperature range is from 35°C to 75°C. Wait for the heater to reach the set temperature before use.
What does the indicator light mean?
The light indicates the heating element is active. When the water reaches the set temperature, the light turns off. It cycles on and off to maintain temperature.
How often should I perform maintenance?
We recommend annual descaling to remove lime deposits, especially in hard water areas. Also check the anode rod every two years and replace it if heavily corroded.
What safety features does the FA-24 B have?
It includes a built-in thermostat, overheat protection, and a pressure relief valve. The pressure relief valve must be installed and should be tested periodically.
Why is there no hot water?
Check if the power supply is on, the circuit breaker is not tripped, and the thermostat is set above the ambient temperature. If the problem persists, the heating element or thermostat may be faulty.
How do I drain the water heater?
Turn off the power and water supply. Attach a hose to the drain valve, open the valve, and open a hot water tap to allow air in. Drain completely before servicing.
Can the water heater be installed outdoors?
No, the FA-24 B is designed for indoor installation only. Exposure to moisture or freezing temperatures can damage the unit.
What is the energy efficiency rating?
This model complies with EU energy efficiency standards. The exact rating is C (typical for standard electric water heaters). For better efficiency, insulate pipes and lower the thermostat setting.
Where can I find spare parts?
Contact Fagor customer service or authorized dealers. Common spare parts include heating elements, thermostats, anode rods, and pressure relief valves. Always use genuine parts for safety.