RE22P - Controller PCE Instruments - Free user manual and instructions
Find the device manual for free RE22P PCE Instruments in PDF.
Pick your language and provide your email: we'll send you a specifically translated version.
| Product Type | Controller |
| Model | RE22P |
| Brand | PCE Instruments |
| Display | Digital LED |
| Input Type | Thermocouple (K, J, etc.) or PT100 |
| Output Type | Relay or SSR |
| Control Method | PID |
| Power Supply | 110-240 V AC |
| Dimensions | 96 x 96 x 75 mm |
| Weight | 0.3 kg |
| Operating Temperature | 0 to 50 °C |
| Storage Temperature | -20 to 70 °C |
| Protection Rating | IP65 (front panel) |
| Mounting | Panel mount |
| Main Functions | On/Off control, PID control, alarm |
| Maintenance | Clean with dry cloth; avoid liquids |
| Safety Features | Overload protection |
| Spare Parts | Contact PCE Instruments support |
| Manual | Free PDF download available |
Frequently Asked Questions - RE22P PCE Instruments
How do I change the temperature setpoint on the RE22P?
Press the SET key, then use the up/down arrows to adjust the value. Press SET again to confirm.
What type of sensor does the RE22P use?
The RE22P accepts thermocouple types K, J, and PT100 RTD sensors. Refer to the manual for wiring.
Can I use the RE22P for cooling control?
Yes, the controller can be configured for heating or cooling mode via the parameters.
How do I reset the controller to factory defaults?
Hold the SET key while powering on until the display shows 'INIT'. Release, then confirm with SET.
What is the maximum output current of the relay?
The relay output is rated for 5 A at 250 V AC (resistive load). For inductive loads, use a contactor.
How do I configure the alarm function?
Enter the parameter menu by holding the SET key for 5 seconds. Navigate to AL1 or AL2 to set alarm type and value.
Is the RE22P suitable for outdoor use?
The front panel is IP65, but the rear is not protected. It should be installed indoors or in a weatherproof enclosure.
What is the power consumption of the RE22P?
Approximately 5 VA at nominal voltage.
How do I connect a solid-state relay (SSR)?
Use the SSR output terminals (typically terminals 13-14). Ensure the SSR voltage matches the controller's output (12 V DC).
Where can I find the user manual?
The manual is available for free download on the PCE Instruments website or at notice-facile.com.
User questions about RE22P PCE Instruments
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
No questions yet. Be the first to ask one.
Download the instructions for your Controller in PDF format for free! Find your manual RE22P - PCE Instruments and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. RE22P by PCE Instruments.