| Product Type | Voltage and Phase Tester |
| Brand | PCE Instruments |
| Model | VPP 20 |
| Category | Measurement |
| Measurement Functions | AC/DC voltage, phase rotation, continuity, resistance |
| Voltage Measurement Range | 12 V to 600 V (AC/DC) |
| Phase Rotation Detection | Three-phase sequence indication via LEDs and beeper |
| Continuity Test | 0 to 1000 Ω with acoustic signal |
| Display | High-brightness LED indicators |
| Safety Rating | CAT III 600 V |
| Dimensions (LxWxH) | Approx. 200 × 65 × 30 mm |
| Weight | Approx. 220 g |
| Power Supply | 2 × 1.5 V AA batteries |
| Operating Temperature | -10 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Overvoltage Category | CAT III 600 V |
| Ingress Protection | IP40 |
| Certifications | CE, TÜV |
| Included Accessories | Test leads, batteries, carrying case, user manual |
| Maintenance | Keep clean and dry; replace batteries when low |
| Cleaning | Use a soft, dry cloth; do not use solvents |
| Safety Precautions | Do not use on live circuits above rated voltage; wear protective equipment |
| Spare Parts and Repairability | Replaceable test leads and batteries; authorized service center |
| General Information | Handheld, lightweight, designed for electrical diagnostics |
Frequently Asked Questions - VPP 20 PCE Instruments
How do I test phase rotation with the PCE VPP 20?
Connect the test probes to the three phases (L1, L2, L3) and observe the phase rotation indicator. The device will show via LEDs and an audible beep whether the sequence is clockwise or counterclockwise.
Can I measure DC voltage with this device?
Yes, the PCE VPP 20 measures AC and DC voltage in a range from 12 V to 600 V. Select the appropriate mode and connect the leads accordingly.
How do I replace the batteries?
Open the battery compartment on the rear of the device. Remove the old AA batteries and insert two new 1.5 V AA batteries, respecting the polarity markings. Close the compartment securely.
What is the maximum voltage I can measure?
The maximum rated voltage is 600 V CAT III. Never exceed this limit to avoid electric shock or damage to the device.
How does the continuity test function work?
Set the rotary switch (or function) to the continuity mode. When the test probes detect a closed circuit below approximately 1000 Ω, the beeper sounds and the LED lights up.
Is the VPP 20 suitable for industrial use?
Yes, it has a robust housing and a CAT III 600 V safety rating, making it suitable for industrial electrical diagnostics. Always follow the safety guidelines.
What do the LED indicators show?
The LEDs provide a clear signal for voltage presence, phase rotation, and continuity. Each function has a distinct LED color or arrangement to avoid confusion.
How should I clean the device?
Use a slightly damp, lint-free cloth to wipe the exterior. Do not immerse in water or use abrasive solvents. Keep the test leads clean and dry.
What are the operating temperature limits?
The device is designed to operate between -10 °C and +50 °C. For storage, the range is -20 °C to +60 °C to maintain measurement accuracy.
Where can I find replacement test leads?
Replacement test leads are available from PCE Instruments or authorized dealers. Check the user manual for the exact part number and contact technical support.
User questions about VPP 20 PCE Instruments
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
No questions yet. Be the first to ask one.
Download the instructions for your Measurement in PDF format for free! Find your manual VPP 20 - PCE Instruments and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. VPP 20 by PCE Instruments.