| Product Type | Pool Pump |
| Brand | AstralPool |
| Model | BX |
| Category | Pump |
| Dimensions (L x W x H) | 250 x 180 x 220 mm |
| Weight | 8.5 kg |
| Power Supply | 230 V / 50 Hz |
| Power Consumption | 0.75 kW |
| Max Flow Rate | 12 m³/h |
| Max Head | 8 m |
| Pump Type | Centrifugal |
| Material | Thermoplastic |
| Protection Rating | IPX5 |
| Sound Level | 65 dB(A) |
| Connection Size | 1 1/2" BSP |
| Functions | Water circulation, filtration |
| Maintenance | Clean strainer basket regularly, check seals |
| Safety Features | Thermal overload protection, IPX5 water resistance |
| Spare Parts | Impeller, diffuser, mechanical seal, O-rings |
| Repairability | Replaceable parts; service by qualified technician |
| Warranty | 2 years |
Frequently Asked Questions - BX ASTRALPOOL
How do I install the AstralPool BX pump?
Ensure the pump is placed on a level, stable surface. Connect the suction and discharge pipes using appropriate fittings. Always install a strainer basket before the pump to prevent debris damage.
What is the maximum flow rate?
The maximum flow rate is 12 m³/h at zero head. Actual flow depends on system resistance.
How often should I clean the strainer basket?
Check the strainer basket weekly and clean it when debris accumulates. A clogged basket reduces pump efficiency.
Why is my pump not priming?
Ensure the pump is flooded with water before starting. Check that the suction line is not blocked and that all connections are airtight. Prime the pump manually if necessary.
What type of oil does the pump use?
The BX pump is a dry-run design; it does not require oil lubrication. The motor bearings are sealed and maintenance-free.
Can I run the pump dry?
No, running the pump dry can damage the mechanical seal. Always ensure the pump is primed before operation.
How do I replace the mechanical seal?
Disconnect power and drain the pump. Remove the motor and rear cover. Replace the seal assembly, ensuring the ceramic and carbon faces are clean. Reassemble and check for leaks.
What is the maximum operating pressure?
The maximum operating pressure is 2.5 bar (36 psi). Do not exceed this to avoid damage.
Is the pump suitable for salt water?
The standard BX pump is designed for fresh water. For salt water or chlorinated pools, check the material compatibility. Some models may require upgraded seals.
Where can I find spare parts?
Spare parts are available through authorized AstralPool dealers or online. Common parts include impeller, diffuser, mechanical seal, and O-rings.