| Product Type | Measuring Transducer |
| Model | SIRAX BT5210 |
| Brand | Camille Bauer |
| Dimensions (HxWxD) | 100 x 75 x 45 mm |
| Weight | 0.2 kg |
| Power Supply | 24 V DC |
| Power Consumption | < 2W |
| Measurement Functions | Current, Voltage, Power, Frequency |
| Accuracy Class | 0.5 |
| Display | 4-digit LED, red |
| Operating Temperature | -10°C to +55°C |
| Storage Temperature | -20°C to +70°C |
| Protection Rating | IP20 (front panel) |
| Electrical Safety | Overvoltage Category III, Pollution Degree 2 |
| Communication Interface | RS485 Modbus RTU |
| Input Types | AC/DC current via CT, voltage direct |
| Mounting | Panel mount (96x48 mm cutout) |
| Cleaning Instructions | Wipe with dry cloth; do not use solvents |
| Maintenance | No user-serviceable parts; refer to manual |
| Warranty | 2 years from date of purchase |
Frequently Asked Questions - SIRAX BT5210 Camille Bauer
How do I connect the SIRAX BT5210 to a current transformer?
Connect the secondary of the CT to the input terminals marked I1 and I2. Ensure the CT ratio matches the device settings.
What is the default Modbus address?
The default Modbus address is 1. You can change it via the front panel or software.
Can I measure DC voltage with this device?
Yes, the SIRAX BT5210 can measure both AC and DC voltage up to 600 V directly.
How do I reset the device to factory settings?
Press and hold the MENU button for 5 seconds, then select 'Factory Reset' from the menu.
What does the error code 'E02' mean?
Error code E02 indicates an input overrange. Check that the measured value does not exceed the maximum rated input.
Is the device calibrated?
Yes, each unit is factory calibrated and comes with a calibration certificate.
Can I use the SIRAX BT5210 in outdoor applications?
No, it is designed for indoor use only with IP20 protection. Protect from moisture and dust.
How do I update the firmware?
Firmware updates are done via the RS485 interface using the Camille Bauer configuration software. Contact support for the latest firmware.
What is the accuracy for current measurement?
The accuracy is 0.5% of reading ±1 digit for current and voltage.
Where can I find the wiring diagram?
The wiring diagram is included in the user manual. It is also available on the Camille Bauer website under the product page.