Notice Stamos S-PLASMA 125H - page 34
Pick your language and provide your email: we'll send you a specifically translated version.
Product Type Plasma cutting machine
Brand Stamos
Model S-PLASMA 125H
Rated output current 125 A
Duty cycle at 125 A 60 % at 40 °C
Input voltage 230 V single-phase
Input frequency 50 / 60 Hz
Maximum cutting thickness (mild steel) 25 mm
Maximum cutting thickness (stainless steel) 16 mm
Dimensions (L x W x H) 480 x 230 x 360 mm
Weight 14,5 kg
Protection rating IP21
Protection class Class I
Plasma gas type Compressed air
Required air pressure 4,5 - 6 bar
Air consumption 150 - 200 L/min
Connector Euro negative center connector
Main functions Cutting, gouging, current adjustment, forced ventilation, thermal protection
Maintenance and cleaning Regularly clean the cooling fins and replace worn consumables
Safety Overheat protection, overvoltage protection, safety lock
Spare parts and repairability Electrodes, nozzles, diffusers, O-rings, side panels
General information Professional plasma cutting machine for industrial and artisan use

Frequently Asked Questions - S-PLASMA 125H Stamos

What is the maximum cutting thickness of the S-PLASMA 125H?
The S-PLASMA 125H can cut up to 25 mm of mild steel and 16 mm of stainless steel under optimal conditions.
What type of gas to use for plasma cutting?
Use clean, dry compressed air. Recommended pressure is between 4,5 and 6 bar.
How to adjust the output current?
The current is adjusted via the rotary knob on the front panel. Adapt the intensity to the thickness of the metal being cut: the thicker the metal, the higher the current should be.
What to do if the torch does not ignite?
First check the air supply and pressure. Then check the condition of the nozzle and electrode: replace worn consumables. Also ensure the work clamp is properly connected.
How to maintain the welding machine?
After each use, clean the cooling fins with a dry brush. Regularly check the condition of consumables and replace them if necessary. Do not expose the device to moisture.
What are the common consumables for this model?
The main consumables are electrodes, nozzles, and diffusers. They are available in replacement kits from Stamos or authorized dealers.
What is the duty cycle at full power?
At 125 A, the duty cycle is 60 % at 40 °C. This means you can weld for 6 minutes out of a 10-minute period before allowing it to cool.
Can I use this machine for gouging?
Yes, the S-PLASMA 125H supports gouging by using a suitable nozzle. Set the current lower and the air slightly stronger for effective gouging work.
What to do in case of overheating?
The device is equipped with thermal protection. If it overheats, the indicator light turns on and the machine stops. Let it cool for about 15 minutes before resuming work. Ensure the air intakes are not blocked.
What is the required supply voltage?
The machine operates on a 230 V single-phase supply with a frequency of 50/60 Hz. A 32 A circuit breaker is recommended for optimal use.

User questions about S-PLASMA 125H Stamos

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Plasma welder in PDF format for free! Find your manual S-PLASMA 125H - Stamos and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. S-PLASMA 125H by Stamos.

USER MANUAL S-PLASMA 125H Stamos

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : Stamos

Model : S-PLASMA 125H

Category : Plasma welder