Product typeSubmersible water pump for clear water
BrandStanley
ModelSXUP750XCE
Power consumption750 W
Supply voltage230 V ~ 50 Hz
Nominal current3.3 A
Maximum flow rate5 000 L/h
Maximum discharge head35 m
Maximum immersion depth7 m
Outlet diameter1 inch (25 mm)
Dimensions (L x W x H)250 x 200 x 350 mm
Weight8 kg
Pump body materialStainless steel
Impeller materialStainless steel
Motor typeAsynchronous motor with permanent capacitor
Thermal protectionYes, with automatic shut-off in case of overheating
Protection ratingIPX8 (permanent immersion)
Power cable length10 m
Main functionsBasement drainage, clear water lifting, garden watering
Maintenance and cleaningClean the suction strainer after each use; rinse with clean water
SafetyPreferably use with a 30 mA residual current circuit breaker
Spare parts availableImpeller, O-ring, check valve, capacitor
RepairabilityRepairability score: 7.5/10 (spare parts available and disassembly possible)

Frequently Asked Questions - SXUP750XCE STANLEY

How do I prime the Stanley SXUP750XCE pump?
Before first use, fill the pump body with water through the outlet until it is full. Then plug in the pump. It is self-priming up to 1 m in height.
Can the pump run dry?
No, dry running damages the pump. It is equipped with thermal protection that stops it in case of overheating, but it is advisable to always keep it submerged.
What should I do if the pump does not start?
First check that the pump is properly powered (cable, plug, circuit breaker). Make sure the suction strainer is not blocked by debris. If the problem persists, the capacitor may be defective.
How do I clean the pump filter?
Unplug the pump, remove the filter basket located under the strainer and rinse it with clean water. A clogged filter reduces flow and may cause overheating.
What is the maximum discharge head?
The maximum discharge head is 35 meters. Beyond that, the flow rate decreases significantly. For high heads, use a hose of appropriate diameter.
Can I use this pump for salt water?
No, this pump is designed for clear water (rainwater, tap water). Salt water corrodes stainless steel parts and damages seals.
What is the maximum immersion depth?
The maximum immersion depth is 7 meters. Do not exceed this value to prevent water intrusion into the motor.
Can the pump run continuously?
Yes, it is designed for continuous operation, but it is recommended to take a few minutes break every hour to avoid overheating during intensive use.
How do I winterize the pump?
Completely drain the water from the pump and hoses. Clean it, dry it, and store it in a frost-free place. Freezing can crack the pump body.
Where can I find spare parts for the Stanley SXUP750XCE?
Spare parts (impeller, seal, check valve, capacitor) are available at authorized Stanley dealers or on online spare parts websites. Use the model number SXUP750XCE for your search.

User questions about SXUP750XCE STANLEY

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Water pump in PDF format for free! Find your manual SXUP750XCE - STANLEY and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. SXUP750XCE by STANLEY.

USER MANUAL SXUP750XCE STANLEY

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : STANLEY

Model : SXUP750XCE

Category : Water pump