Product Type Uninterruptible Power Supply (UPS)
Model FP 1500
Brand FSP
Power Rating 1500 VA / 900 W
Topology Line-Interactive with AVR
Input Voltage 230 VAC, 50/60 Hz
Output Voltage 230 VAC ±10% (battery mode)
Waveform Simulated sine wave
Number of Outlets 4 x IEC 320 C13 (battery + surge) + 2 x IEC 320 C13 (surge only)
Battery Type Sealed Lead-Acid (SLA), maintenance-free
Battery Quantity 2 x 12V/9Ah (internal)
Typical Backup Time ~10-15 min at full load
Recharge Time 4-6 hours to 90%
Dimensions (W x D x H) 440 x 400 x 88 mm (rackmount 2U)
Net Weight ~19 kg
Communication Ports USB, RS-232 (dry contact)
Software FSP PowerManager (Windows)
Protection Features Surge protection, overcharge, overload, short circuit
Noise Level < 45 dBA at 1m
Operating Temperature 0°C to 40°C
Certifications CE, RoHS

Frequently Asked Questions - FP 1500 FSP

What does the FSP FP 1500 protect against?
The FSP FP 1500 protects connected equipment against power outages, sags, surges, and brownouts by providing battery backup and automatic voltage regulation (AVR).
How do I replace the battery in the FP 1500?
The battery compartment is located on the front panel. Remove the bezel, disconnect the battery connectors, slide out the old batteries, and insert new identical 12V/9Ah SLA batteries. Reassemble and charge for 4-6 hours before use.
What is the typical runtime at half load?
At half load (450W), the FP 1500 provides approximately 20-30 minutes of backup time, depending on battery age and condition.
Can I connect the FP 1500 to a generator?
It is not recommended. The UPS may have difficulty synchronizing with generator output, which can cause damage. Use a line-interactive or online UPS for generator compatibility.
Why does my FP 1500 beep continuously?
Continuous beeping often indicates a battery fault or overload. Check the load (should be below 900W) and ensure battery connections are tight. If the issue persists, replace the battery.
How do I perform a self-test?
Press and hold the ON/TEST button for 2-3 seconds. The UPS will switch to battery mode briefly to verify functionality. This can be done monthly.
What software is available for monitoring?
FSP offers PowerManager software for Windows, which provides monitoring, scheduled shutdown, and logging via USB or RS-232 connection.
Can I mount the FP 1500 in a rack?
Yes, the FP 1500 is designed for 2U rackmount installation. It includes rack ears and supports tower orientation as well.
What is the recommended maintenance schedule?
Perform a self-test monthly, clean the vents quarterly, and replace the battery every 3-5 years or when runtime decreases significantly.
Does the FP 1500 support hot-swap battery?
No, the battery is internal and not hot-swappable. Power off the UPS and disconnect mains before replacing the battery.

User questions about FP 1500 FSP

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Alimentation sans coupure in PDF format for free! Find your manual FP 1500 - FSP and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. FP 1500 by FSP.

USER MANUAL FP 1500 FSP

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : FSP

Model : FP 1500

Category : Alimentation sans coupure