| Product Type | Portable Air Conditioner |
| Brand | Airrex |
| Model | HSC-14P |
| Cooling Capacity | 14,000 BTU/h |
| Power Consumption (Cooling) | 1350 W |
| Energy Efficiency Ratio (EER) | 10.4 |
| Refrigerant Type | R410A |
| Air Flow (High Speed) | 420 m³/h |
| Noise Level (Low/High) | 48 / 54 dB(A) |
| Timer | 24-hour on/off timer |
| Remote Control | Yes, with LCD display |
| Dehumidification Function | Yes, up to 2.8 L/h |
| Fan Speeds | 3 (Low/Medium/High) |
| Auto Swing Louvers | Yes, vertical oscillation |
| Dimensions (W x D x H) | 450 x 380 x 720 mm |
| Net Weight | 28 kg |
| Power Supply | 220-240 V, 50 Hz |
| Recommended Room Size | Up to 40 m² |
| Self-Evaporative System | Yes, no external drainage needed in most conditions |
| Washable Filter | Yes, easy to remove and clean |
| Caster Wheels | 4 swivel casters for mobility |
| Safety Features | Auto shut-off on overheat, overload protection, anti-freeze protection |
| Maintenance | Clean filter every 2 weeks; wipe exterior with damp cloth |
| Spare Parts Available | Remote control, filter, exhaust hose kit |
Frequently Asked Questions - HSC-14P Airrex
How do I install the HSC-14P portable air conditioner?
Place the unit near a window. Extend the exhaust hose to the window kit, ensuring a tight seal. Plug into a grounded outlet. Ensure the air filter is clean before first use.
How often should I clean the air filter?
Clean the filter every two weeks under normal use. Remove the filter, wash with mild detergent, rinse, and dry completely before reinstalling.
What does the 'FL' error code mean?
The 'FL' error indicates a full water tank. Some models have a self-evaporative system, but if humidity is high, the tank may fill. Drain the tank through the bottom drain plug.
Can I use the HSC-14P without an exhaust hose?
No, the exhaust hose must be vented to the outside to remove hot air. Without it, the unit cannot cool effectively and may overheat.
Why is my unit not cooling enough?
Ensure the air filter is clean, the room is not too large (max 40 m²), all windows and doors are closed, and the exhaust hose is not blocked or kinked. Also check that the set temperature is below room temperature.
Does the HSC-14P require drainage?
In normal cooling mode with moderate humidity, the self-evaporative system expels moisture through the exhaust. In very humid conditions, the internal tank may need manual drainage via the bottom plug.
How do I use the remote control?
Insert two AAA batteries (not included). Point the remote at the unit's receiver. Use buttons for power, mode (cool/dry/fan), temperature up/down, fan speed, timer, and swing.
What is the recommended room temperature setting?
For energy efficiency, set the thermostat between 24°C and 26°C (75°F - 78°F). Lower settings increase power consumption without proportional cooling benefit.
Can I leave the unit on all day?
Yes, the HSC-14P is designed for continuous operation. Use the timer to schedule on/off times. Ensure proper ventilation of the exhaust hose.
Where can I purchase spare parts?
Spare parts such as filters, remote controls, and exhaust hose kits are available from authorized Airrex dealers or online retailers. Use the part number from your manual.
User questions about HSC-14P Airrex
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
No questions yet. Be the first to ask one.
Download the instructions for your Air Conditioning in PDF format for free! Find your manual HSC-14P - Airrex and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. HSC-14P by Airrex.