Notice Rigol MSO5204 - page 3
Pick your language and provide your email: we'll send you a specifically translated version.
Product TypeMixed Signal Oscilloscope
Bandwidth200 MHz
Analog Channels4
Digital Channels16 (MSO logic channels)
Maximum Sample Rate8 GSa/s (half-channel), 4 GSa/s (all channels)
Memory Depth200 Mpts per channel (standard)
Display10.1-inch WVGA color TFT LCD (1024x600)
Vertical Resolution8-bit (up to 10-bit with averaging)
Timebase Range1 ns/div to 100 s/div
Input Impedance1 MΩ ±1% || 15 pF
Maximum Input Voltage300 V RMS (CAT I)
Trigger TypesEdge, Pulse, Video, Slope, Pattern, Duration, Serial (I2C, SPI, UART, CAN, LIN)
Supported ProtocolsI2C, SPI, UART, CAN, LIN, I2S
ConnectivityUSB Host/Device, LAN (LXI), VGA, external trigger, probe compensation output
Power Supply100-240 VAC, 50/60 Hz, <70W
Dimensions (W x H x D)395 mm x 180 mm x 135 mm (15.6 in x 7.1 in x 5.3 in)
Weight6.8 kg (15 lbs)
CoolingActive fan cooling
Cleaning InstructionsDisconnect power; wipe with dry cloth; no solvents
Safety PrecautionsUse grounded outlet; do not exceed input limits; keep vents clear
RepairabilityCalibration and service by qualified personnel only; no user-serviceable parts

Frequently Asked Questions - MSO5204 Rigol

How to measure a DC voltage?
Connect the probe to the channel input and set vertical scale (VOLTS/DIV) appropriately. Press Auto Set or manually adjust horizontal and vertical. Read voltage from cursor or measurement menu.
How to use the trigger function?
Press the Trigger menu. Select trigger type (Edge, Pulse, etc.). Set slope (rising/falling) and level. For edge trigger, adjust level using the Level knob.
How to capture a single shot waveform?
Set trigger mode to Normal or Single. Press Run/Stop once to arm the trigger. The oscilloscope waits for the trigger condition and then captures the waveform.
How to perform FFT analysis?
Press Math button, select FFT. Choose source channel and window type (Hanning, Hamming, etc.). Adjust frequency span and center frequency using the scales.
How to save a waveform or screenshot?
Insert a USB flash drive. Press Save/Recall, choose Storage and file type (BMP, CSV, etc.). For waveform, select Waveform format. Press Save Now.
What is the maximum input voltage?
The maximum input voltage is 300 V RMS (CAT I). With a 10x probe, it can measure up to 3000 V. Ensure not to exceed ratings to avoid damage.
How to compensate a probe?
Connect the probe to the Probe Comp terminal. Set probe attenuation (e.g., 10x). Adjust the compensation screw on the probe box until the square wave is flat.
How to measure frequency and period?
Apply a signal. Open the Measure menu, add measurements. Select Frequency and Period. The values appear on screen. Alternatively use cursors.
How to decode serial data (e.g., UART)?
Connect signals to digital lines (or analog). Press Decode button, select protocol (UART). Set baud rate, parity, data bits. Decoded information appears in a bus display.
How to update firmware?
Download the latest firmware from Rigol website. Copy to USB flash drive. On oscilloscope, press Utility -> Update and follow prompts. Do not power off during update.

User questions about MSO5204 Rigol

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Measuring equipment in PDF format for free! Find your manual MSO5204 - Rigol and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. MSO5204 by Rigol.

USER MANUAL MSO5204 Rigol

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : Rigol

Model : MSO5204

Category : Measuring equipment