HAGER AKB41500402 - Electrical installation system

AKB41500402 - Electrical installation system HAGER - Free user manual and instructions

Find the device manual for free AKB41500402 HAGER in PDF.

📄 64 pages English EN Download 💬 AI Question 10 questions ⚙️ Specs
Notice HAGER AKB41500402 - page 5
Pick your language and provide your email: we'll send you a specifically translated version.
Product Type Residual Current Device (RCD)
Model AKB41500402
Brand Hager
Number of Poles 4
Rated Current 40 A
Rated Residual Operating Current 30 mA (type AC)
Rated Voltage 230/400 V AC
Frequency 50/60 Hz
Breaking Capacity 10 kA
Dimensions (H x W x D) 85 x 72 x 69 mm
Weight 0.3 kg
Mounting DIN rail (35 mm)
Enclosure Protection IP20
Operating Temperature -25 °C to 40 °C
Standards Compliance IEC/EN 61008-1
Test Button Yes, monthly test recommended
Connection Capacity Up to 25 mm²
Maintenance Periodic testing and visual inspection
Safety Features Overvoltage protection, fault indication
Spare Parts Availability Yes, through Hager distributors
Reparability Replaceable if faulty; must be done by qualified electrician

Frequently Asked Questions - AKB41500402 HAGER

What is the AKB41500402?
It is a 4-pole residual current device (RCD) from Hager, rated 40A/30mA, for earth fault protection.
How do I install the AKB41500402?
Mount on a 35mm DIN rail inside a distribution board. Connect phase and neutral lines according to markings. Ensure power is off before installation.
How often should I test the RCD?
It is recommended to press the test button every month to ensure proper operation. If it fails to trip, contact a qualified electrician.
What does the test button do?
Simulates an earth leakage fault to verify the RCD mechanism is functional. The device should trip immediately.
Can I use this RCD for overload protection?
No, this RCD provides only earth leakage protection. Overload and short-circuit protection require a separate circuit breaker.
What is the rated residual current of 30 mA?
It means the device will trip when a leakage current exceeds 30 mA, protecting against electrocution in normal conditions.
Is this device suitable for three-phase systems?
Yes, it is a 4-pole RCD designed for three-phase with neutral systems up to 400V.
What should I do if the RCD trips frequently?
Check for faulty appliances or wiring. If the problem persists, consult an electrician as it may indicate a serious leakage issue.
Can I replace just the RCD or do I need to replace the whole unit?
The RCD is a replaceable module. However, any work must be done by a qualified professional to ensure safety.
Where can I find spare parts or accessories?
Spare parts are available from authorized Hager distributors or online electrical supply stores. Verify compatibility with this model.

User questions about AKB41500402 HAGER

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Electrical installation system in PDF format for free! Find your manual AKB41500402 - HAGER and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. AKB41500402 by HAGER.

USER MANUAL AKB41500402 HAGER

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : HAGER

Model : AKB41500402

Category : Electrical installation system