Product Type Digital Multimeter
Brand Steinberg
Model SBS-MT-100
Category Measuring Equipment
Dimensions (L x W x H) 150 x 70 x 30 mm
Weight 250 g
Power Supply 9V battery (type 6F22)
Display LCD digital, 2000 counts
Main Functions AC/DC voltage measurement, AC/DC current, resistance, continuity, diode
DC Voltage Measurement Range 200 mV - 600 V
AC Voltage Measurement Range 200 mV - 600 V
DC Current Measurement Range 200 µA - 10 A
AC Current Measurement Range 200 µA - 10 A
Resistance Measurement Range 200 Ω - 20 MΩ
Continuity Test Yes
Diode Test Yes
Safety Double insulation, CAT II 600 V, CAT III 300 V
Maintenance and Cleaning Clean with a dry cloth, avoid moisture
Included Accessories Batteries, test leads, user manual
Warranty 2 years
Certifications CE, RoHS

Frequently Asked Questions - SBS-MT-100 STEINBERG

How to measure DC voltage with the SBS-MT-100?
Set the selector to the V--- position (DC voltage). Connect the test leads: red to the VΩmA terminal, black to the COM terminal. Connect the probes to the measurement points. The voltage is displayed on the LCD screen.
What battery to use for the SBS-MT-100?
The device operates with a 9V battery type 6F22. Insert it respecting the polarity indicated in the battery compartment.
How to test continuity of a circuit?
Turn the selector to the continuity test position (diode or sound wave symbol). Connect the leads. If the resistance is below about 50 Ω, a beep sounds.
What safety precautions should be followed?
Never measure a voltage above 600 V DC or AC. Use the appropriate terminals and ranges. Remove the leads before opening the housing. The device is certified CAT II 600 V and CAT III 300 V.
How to clean the multimeter?
Turn off the device and remove the leads. Clean the housing with a soft dry cloth. Do not use abrasive products or solvents. Avoid any moisture penetration.
What to do if the screen displays 'OL'?
'OL' means Overload (range exceeded). This indicates that the measured value is higher than the selected range. Switch to a higher range or check your connections.
How to replace the battery of the SBS-MT-100?
Turn off the device and remove the leads. Open the battery compartment at the back using a screwdriver. Replace the used 9V battery with a new one respecting polarity. Close the compartment.
What accessories are included in the package?
The package contains the SBS-MT-100 multimeter, one 9V battery, a pair of test leads, and a user manual.
How to measure AC current?
Turn the selector to the A~ position (AC current). Connect the red lead to the 10A terminal for high currents, or to VΩmA for low currents. Connect the multimeter in series with the circuit.
What is the voltage measurement resolution?
The resolution is 0.1 mV on the 200 mV range and 1 V on the 600 V range. The display count is 2000 counts.

User questions about SBS-MT-100 STEINBERG

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Measuring equipment in PDF format for free! Find your manual SBS-MT-100 - STEINBERG and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. SBS-MT-100 by STEINBERG.

USER MANUAL SBS-MT-100 STEINBERG

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : STEINBERG

Model : SBS-MT-100

Category : Measuring equipment