OTS60SX/2 - Measuring equipment Megger - Free user manual and instructions
Find the device manual for free OTS60SX/2 Megger in PDF.
Pick your language and provide your email: we'll send you a specifically translated version.
| Brand | Megger |
| Model | OTS60SX/2 |
| Product type | Insulation resistance tester (megohmmeter) |
| Category | Electrical measuring equipment |
| Dimensions (L x W x H) | 350 x 270 x 150 mm |
| Weight | Approximately 5 kg |
| Power supply | Mains 90-264 V AC, 50/60 Hz or internal rechargeable battery |
| Test voltage | 500 V, 1000 V, 2500 V, 5000 V |
| Measurement range | 10 kΩ to 10 TΩ |
| Main functions | Insulation resistance (IR), polarization index (PI), dielectric absorption ratio (DAR), step voltage (SV) test, insulation discharge (DD), capacitance meter |
| Display | Backlit LCD with graphics and numerical results |
| Safety | CAT IV 600 V, double insulation, overvoltage protection |
| Maintenance and cleaning | Clean with a soft, dry cloth. Do not use solvents. Check the condition of test leads periodically. |
| Spare parts and repairability | Batteries, fuses, test leads available. Repair by Megger authorized service center. |
| Data storage | Internal memory for 500 results, transfer via USB |
| Interface | USB type B, optional Bluetooth |
| Operating temperature | -10 °C to +50 °C |
| Included accessories | 3 test leads (red, black, blue), alligator clips, mains adapter, USB cable, user manual |
| Warranty | 3 years |
Frequently Asked Questions - OTS60SX/2 Megger
What test voltages are available on the Megger OTS60SX/2?
The Megger OTS60SX/2 offers test voltages of 500 V, 1000 V, 2500 V, and 5000 V for measuring insulation resistance.
How to perform a polarization index (PI) test?
Select the PI function on the device. The test lasts 10 minutes: the device measures resistance at 1 min and 10 min, then calculates the ratio. A PI greater than 2 indicates good insulation.
Can I use the device on live circuits?
No, the OTS60SX/2 is designed for measurements on de-energized circuits. Make sure the equipment is disconnected and discharged before starting the test.
How to maintain the internal battery?
The device uses a Li-ion battery. Recharge it fully after each use. For long battery life, do not let the battery discharge completely.
What to do if the screen displays 'Overload error'?
This means the measured resistance exceeds the range or an overvoltage is detected. Check the connections and test voltage. If the error persists, contact technical support.
How to transfer data to a computer?
Connect the device to the computer via USB cable. Use the Megger PowerDB software or a serial terminal to download the results stored in memory.
What accessories are included?
The device comes with three test leads (red, black, blue), alligator clips, a mains adapter, a USB cable, and a user manual.
Is the device suitable for outdoor use?
Yes, it can operate from -10 °C to +50 °C. However, avoid exposure to rain or excessive humidity. Use a shelter if necessary.
How to calibrate the Megger OTS60SX/2?
Calibration must be performed by a Megger accredited laboratory. It is recommended to calibrate the device every 12 months to ensure measurement accuracy.
Can I replace the fuses myself?
Yes, the device contains fuses accessible on the rear panel. Only use fuses of the type and rating specified in the manual.