| Product Type | Temperature Controller / Thermometer Readout |
| Brand | Fluke |
| Model | 1502A |
| Measurement Range | -200°C to 962°C (with suitable PRT) |
| Accuracy | ±0.01°C at 0°C |
| Resolution | 0.001°C |
| Input Type | 4-wire platinum resistance thermometer (PRT) |
| Display | LCD with backlight |
| Power Supply | 100-240 VAC, 50/60 Hz, 15 VA max |
| Dimensions | 88 mm x 178 mm x 238 mm (H x W x D) |
| Weight | 0.9 kg (2 lb) |
| Interfaces | RS-232 standard; GPIB optional |
| Functions | Temperature measurement, data logging, calibration, scan mode |
| Safety | Overvoltage protection, built-in fuse |
| Maintenance | Clean exterior with a damp cloth; do not use solvents |
| Spare Parts | AC power cord, RS-232 cable, probe connectors |
| Repairability | Calibration and service by qualified technicians only |
| Certifications | CE, NIST traceable calibration included |
| Operating Temperature | 0°C to 40°C |
| Storage Temperature | -20°C to 70°C |
Frequently Asked Questions - 1502A FLUKE
How do I connect a PRT probe to the Fluke 1502A?
Connect the probe using the 4-wire input terminals. Ensure the probe is compatible with the 1502A's range and accuracy.Use only platinum resistance thermometers (PRTs) with a nominal resistance of 100 ohms.
What is the maximum temperature the 1502A can measure?
The 1502A can measure from -200°C to 962°C with an appropriate PRT probe. The upper limit depends on the probe's rating.
How do I calibrate the Fluke 1502A?
The 1502A can be re-calibrated via the front panel or remote interface using known resistance standards. Refer to the manual for full calibration procedures. Regular calibration is recommended every 12 months.
Can I use the 1502A for data logging?
Yes, the 1502A supports data logging via its RS-232 interface. You can log temperature readings at programmed intervals using the LOG function and download data to a PC.
What are the RS-232 commands supported?
Commands include IDN? (identification), FETCh? (fetch reading), CONFigure, and SYSTem:ERROR?. A full list is in the programming manual.
Does the 1502A have a battery backup?
No internal battery for continuous operation. However, the unit retains calibration and configuration settings in non-volatile memory even when powered off.
How do I clean the 1502A?
Disconnect power and clean the exterior with a soft, damp cloth. Do not use abrasive cleaners, solvents, or immerse the unit in liquid.
What should I do if the display shows 'Overload'?
An 'Overload' indicates the input signal exceeds the measurement range. Check your probe connection, ensure it is within the -200°C to 962°C range, and verify the probe is not shorted or open.
Can I use the 1502A with a thermocouple?
No, the 1502A is designed exclusively for 4-wire platinum resistance thermometers (PRTs). For thermocouple measurements, use a different instrument like the Fluke 1524.
Where can I download the manual for the 1502A?
The user manual and programming guide are available for free on notice-facile.com in PDF format. Search for Fluke 1502A to download.