9171 - Temperature Controller FLUKE - Free user manual and instructions
Find the device manual for free 9171 FLUKE in PDF.
Pick your language and provide your email: we'll send you a specifically translated version.
| Product Type | Temperature Controller / Calibrator |
| Brand | Fluke |
| Model | 9171 |
| Dimensions (H x W x D) | 12.2 x 8.6 x 18.1 cm |
| Weight | 2.3 kg |
| Power Supply | 100-240 V AC, 50/60 Hz |
| Battery Type | Rechargeable NiMH |
| Battery Life | Approximately 20 hours continuous use |
| Measurement Functions | Thermocouple, RTD, Thermistor, and Voltage |
| Accuracy | ±0.3°C for thermocouple; ±0.05°C for RTD |
| Temperature Range | -200°C to 1372°C (depending on sensor) |
| Interfaces | USB, RS-232 |
| Display | LCD with backlight, dual line |
| Maintenance | Clean with a soft, dry cloth; do not use solvents |
| Safety Rating | EN 61010-1, CAT II 300V |
| Protection | Overload and input protection |
| Spare Parts | Replaceable test leads, thermocouple adapter, battery pack |
| Repairability | Service center recommended; user-replaceable battery |
| Warranty | 1 year standard |
| Included Accessories | Test leads, thermocouple, battery, charger, manual |
Frequently Asked Questions - 9171 FLUKE
What is the Fluke 9171 temperature controller used for?
The Fluke 9171 is a precision temperature controller and calibrator used for simulating and measuring temperature sensors such as thermocouples, RTDs, and thermistors. It is ideal for field calibration and maintenance.
How do I replace the battery in the Fluke 9171?
The battery is user-replaceable. Remove the battery compartment cover on the bottom of the unit, disconnect the old battery, and connect a new NiMH battery pack. Ensure correct polarity.
Can the Fluke 9171 measure both Celsius and Fahrenheit?
Yes, the device allows you to toggle between Celsius and Fahrenheit via the setup menu.
What types of thermocouples does the 9171 support?
The Fluke 9171 supports standard thermocouple types: K, J, T, E, N, R, S, and B.
How do I calibrate the Fluke 9171?
Calibration should be performed by a qualified technician using a certified reference. The device has a calibration adjustment menu accessible from the setup.
Is the Fluke 9171 compatible with PC software?
Yes, it includes a USB and RS-232 interface for connection to Fluke's calibration software for data logging and automated testing.
What is the maximum input voltage for the Fluke 9171?
The input protection is rated for CAT II 300V. Do not exceed 300V relative to earth ground.
Can I use the Fluke 9171 to simulate a 4-20 mA loop?
No, the Fluke 9171 is designed for temperature sensors and voltage measurement only. For 4-20 mA simulation, consider other Fluke calibrators.
How often should the Fluke 9171 be calibrated?
Fluke recommends a 12-month calibration interval, depending on usage and accuracy requirements.
What should I do if the display shows an error?
Refer to the manual's troubleshooting section. Common errors include 'OL' (overload) or 'Err' (sensor fault). Check connections and ensure the sensor is within range.