Product Type Temperature Controller / Calibrator
Brand Fluke
Model 9171
Dimensions (H x W x D) 12.2 x 8.6 x 18.1 cm
Weight 2.3 kg
Power Supply 100-240 V AC, 50/60 Hz
Battery Type Rechargeable NiMH
Battery Life Approximately 20 hours continuous use
Measurement Functions Thermocouple, RTD, Thermistor, and Voltage
Accuracy ±0.3°C for thermocouple; ±0.05°C for RTD
Temperature Range -200°C to 1372°C (depending on sensor)
Interfaces USB, RS-232
Display LCD with backlight, dual line
Maintenance Clean with a soft, dry cloth; do not use solvents
Safety Rating EN 61010-1, CAT II 300V
Protection Overload and input protection
Spare Parts Replaceable test leads, thermocouple adapter, battery pack
Repairability Service center recommended; user-replaceable battery
Warranty 1 year standard
Included Accessories Test leads, thermocouple, battery, charger, manual

Frequently Asked Questions - 9171 FLUKE

What is the Fluke 9171 temperature controller used for?
The Fluke 9171 is a precision temperature controller and calibrator used for simulating and measuring temperature sensors such as thermocouples, RTDs, and thermistors. It is ideal for field calibration and maintenance.
How do I replace the battery in the Fluke 9171?
The battery is user-replaceable. Remove the battery compartment cover on the bottom of the unit, disconnect the old battery, and connect a new NiMH battery pack. Ensure correct polarity.
Can the Fluke 9171 measure both Celsius and Fahrenheit?
Yes, the device allows you to toggle between Celsius and Fahrenheit via the setup menu.
What types of thermocouples does the 9171 support?
The Fluke 9171 supports standard thermocouple types: K, J, T, E, N, R, S, and B.
How do I calibrate the Fluke 9171?
Calibration should be performed by a qualified technician using a certified reference. The device has a calibration adjustment menu accessible from the setup.
Is the Fluke 9171 compatible with PC software?
Yes, it includes a USB and RS-232 interface for connection to Fluke's calibration software for data logging and automated testing.
What is the maximum input voltage for the Fluke 9171?
The input protection is rated for CAT II 300V. Do not exceed 300V relative to earth ground.
Can I use the Fluke 9171 to simulate a 4-20 mA loop?
No, the Fluke 9171 is designed for temperature sensors and voltage measurement only. For 4-20 mA simulation, consider other Fluke calibrators.
How often should the Fluke 9171 be calibrated?
Fluke recommends a 12-month calibration interval, depending on usage and accuracy requirements.
What should I do if the display shows an error?
Refer to the manual's troubleshooting section. Common errors include 'OL' (overload) or 'Err' (sensor fault). Check connections and ensure the sensor is within range.

User questions about 9171 FLUKE

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Temperature Controller in PDF format for free! Find your manual 9171 - FLUKE and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. 9171 by FLUKE.

USER MANUAL 9171 FLUKE

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : FLUKE

Model : 9171

Category : Temperature Controller