| Product Type | Electric Storage Water Heater |
| Model | TR2000T 80 B |
| Brand | Bosch |
| Capacity | 80 liters |
| Power Supply | 230 V ~ 50 Hz |
| Power Consumption | 2.0 kW (heating element) |
| Dimensions (H x W x D) | Approx. 850 x 450 x 450 mm |
| Weight | Approx. 25 kg (empty) |
| Insulation | High-efficiency polyurethane foam |
| Tank Material | Enameled steel with magnesium anode |
| Max Water Temperature | 75 °C (adjustable) |
| Safety Features | Thermostat, thermal cut-out, safety valve |
| Installation | Wall-mounted, horizontal or vertical |
| Water Connection | G 1/2 inch inlet/outlet |
| Energy Efficiency Class | C (typical for electric storage heaters) |
| Control Type | Mechanical thermostat with indicator light |
| Maintenance | Annual inspection of anode and safety valve |
| Spare Parts Availability | Heating element, thermostat, anode, gaskets |
| Reparability | Modular design allows easy replacement of components |
| Included Accessories | Safety valve, mounting brackets |
Frequently Asked Questions - TR2000T 80 B BOSCH
How do I install the Bosch TR2000T 80 B boiler?
Installation must be done by a qualified professional. Ensure the wall can support the weight. Connect water supply (G 1/2 inch) and electrical supply (230 V). Fit the safety valve as per manual.
How do I adjust the water temperature?
Turn the thermostat knob located on the front panel. The temperature range is 30-75 °C. Wait for the heating element to reach the set temperature. The indicator light shows when heating.
What is the recommended temperature setting?
For energy efficiency and to prevent scalding, set between 55-60 °C. Higher temperatures increase energy consumption and risk of burns.
How often should I maintain the boiler?
Perform annual maintenance: check the magnesium anode for corrosion, test the safety valve, and drain a few liters to remove sediment. Replace anode if consumed by 50%.
Why is water not heating?
Check if power is on and thermostat is set. The thermal cut-out may have tripped (press reset button). If still not working, the heating element might be faulty.
Water is leaking from the boiler. What should I do?
Immediately turn off power and water supply. Leaks can occur from pipe connections, the safety valve (if pressure too high), or internal tank corrosion. Call a technician.
Can I install the boiler horizontally?
Yes, the TR2000T 80 B can be mounted either horizontally or vertically. Ensure proper support and that the water connections are oriented correctly as per manual.
How do I drain the boiler?
Turn off power and water supply. Connect a hose to the drain valve (at bottom). Open the valve and a hot water tap to allow air in. Drain completely for maintenance or winter storage.
What spare parts are available?
Common spare parts: heating element, thermostat, magnesium anode, gaskets, and safety valve. Order from Bosch service centers or authorized dealers using model number TR2000T 80 B.
Is the boiler safe to touch when operating?
The exterior remains cool to touch due to high-efficiency insulation. However, avoid touching hot water pipes. The tank surface temperature is typically below 40 °C.