| Product Type | Bottle Sterilizer |
| Brand | Royal Catering |
| Model | RC-KSSS501 |
| Dimensions (L x D x H) | 42 x 35 x 28 cm |
| Weight | 5.2 kg |
| Power Supply | 220-240 V ~ 50/60 Hz |
| Power | 800 W |
| Capacity | 6 standard bottles |
| Sterilization Temperature | 100 °C (steam) |
| Main Functions | Steam sterilization, drying cycle |
| Housing Material | Stainless steel |
| Basket Material | Heat-resistant plastic |
| Operating indicator light | Yes |
| Automatic shut-off | Yes, at the end of the cycle |
| Cleaning | Clean with a damp cloth; basket dishwasher safe |
| Maintenance | Regular descaling recommended (every 3 months) |
| Safety | Overheat protection, safety lid lock |
| Included accessories | 1 basket, 1 lid, user manual |
| Spare parts available | Yes (basket, gasket, lid) |
| Repairability | Repairability index: 7.5 / 10 |
| Warranty | 2 years |
| Country of manufacture | China |
Frequently Asked Questions - RC-KSSS501 Royal Catering
User questions about RC-KSSS501 Royal Catering
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
Download the instructions for your Bottle sterilizer in PDF format for free! Find your manual RC-KSSS501 - Royal Catering and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. RC-KSSS501 by Royal Catering.
USER MANUAL RC-KSSS501 Royal Catering
Safety & Operating Instructions
This User Manual has been translated using machine translation. We have made every effort to ensure the translation is accurate, but please note that automated translations are not perfect and are not meant to replace human translators. The official version of the User Manual is in English. Any differences between the translated version and the original English are not legally binding. If you have any questions about the accuracy of the translation, please refer to the English version, which is the official reference. More language versions are available upon request via info@expondo.com.
Technical data
| Parameter description | Parameter value | |
| Product name | Knife steriliser | |
| Model | RC-KSSS201 | RC-KSSS501 |
| Rated voltage [V~] / frequency [Hz] | 230 / 50 | |
| Rated power [W] | 8 | |
| Protection class | | | |
| Dimensions [width x depth x height, mm] | 570x350x125 | 590x440x125 |
| Weight [kg] | 5 | 5.9 |
| Magnetic strip length [mm] | 308,0 | 398,0 |
| Timer [min] | 0-60 | |
| Knife slots | 14 | 20 |
1. General description
The user manual is designed to assist in the safe and trouble-free use of the device. The product is designed and manufactured in accordance with strict technical guidelines, using state-of-the-art technologies and components. Additionally, it is produced in compliance with the most stringent quality standards.
DO NOT USE THE DEVICE UNLESS YOU HAVE THOROUGHLY READ AND UNDERSTOOD THIS USER MANUAL.
To increase the product life of the device and to ensure trouble-free operation, use it in accordance with this user manual and regularly perform maintenance tasks. The technical data and specifications in this user manual are up to date. The manufacturer reserves the right to make changes associated with quality improvement. The device is designed to reduce noise emission risks to a minimum, taking into account technological progress and noise reduction opportunities.
Legend
| CE | The product satisfies the relevant safety standards. |
![]() | Read instructions before use. |
![]() | The product must be recycled. |
![]() | WARNING! or CAUTION! or REMEMBER! Applicable to the given situation.(general warning sign) |
![]() | Wear protective goggles.WARNING! UV radiation is harmful to health. Do not expose eyes and skin to the device operation (UV-C radiation). |
![]() | |
![]() | ATTENTION! Electric shock warning! |
![]() | These devices have basic insulation but also rely on a physical connection to the earth (ground) for safety. |
![]() | ATTENTION! Hot surface, risk of burns! |
![]() | Only use indoors. |

PLEASE NOTE! Drawings in this manual are for illustration purposes only and in some details may differ from the actual product.
2. Usage safety

ATTENTION! Read all safety warnings and all instructions. Failure to follow the warnings and instructions may result in electric shock, fire and/or serious injury or even death.
The terms "device" or "product" are used in the warnings and instructions to refer to: Knife steriliser.
2.1. Electrical safety
a) The plug must fit the socket. Do not modify the plug in any way. Using original plugs and matching sockets reduces the risk of electric shock. b) Do not touch the device with wet or damp hands. c) Use the cable only for its designated use. Never use it to carry the device or to pull the plug out of a socket. Keep the cable away from heat sources, oil, sharp edges or moving parts. Damaged or tangled cables increase the risk of electric shock. d) If using the device in a damp environment cannot be avoided, a residual current device (RCD) should be applied. The use of an RCD reduces the risk of electric shock. e) Do not use the device if the power cord is damaged or shows obvious signs of wear. A damaged power cord should be replaced by a qualified electrician or the manufacturer's service centre. f) To avoid electric shock, do not immerse the cord, plug or device in water or other liquids. Do not use the device on wet surfaces. g) ATTENTION! DANGER TO LIFE! While cleaning, never immerse the device in water or other liquids.
2.2. Safety in the workplace
a) Make sure the workplace is clean and well lit. A messy or poorly lit workplace may lead to accidents. Try to think ahead, observe what is going on and use common sense when working with the device.
b) If there are any doubts as to the correct operation of the device, contact the manufacturer's support service. c) Only the manufacturer's service point may repair the device. Do not attempt any repairs independently! d) In case of fire, use a powder or carbon dioxide (CO2) fire extinguisher (one intended for use on live electrical devices) to put it out. e) Please keep this manual available for future reference. If this device is passed on to a third party, the manual must be passed on with it. f) Keep packaging elements and small assembly parts in a place not available to children. g) Keep the device away from children and animals.

Remember! When using the device, protect children and other bystanders.
2.3. Personal safety
a) Do not use the device when tired, ill, or under the influence of alcohol, narcotics, or medication that can significantly impair the ability to operate the device. b) The device is not designed to be handled by persons (including children) with limited mental and sensory functions or persons lacking relevant experience and/or knowledge unless they are supervised by a person responsible for their safety or they have received instruction on how to operate the device. c) The device can be handled only by physically fit persons who are capable of handling it, properly trained, familiar with this manual, and trained within the scope of occupational health and safety. d) When working with the device, use common sense and stay alert. Temporary loss of concentration while using the device may lead to serious injuries. e) Use personal protective equipment as required for working with the device, specified in section 1 (Legend). The use of correct and approved personal protective equipment reduces the risk of injury. f) To prevent the device from accidentally switching on, make sure the switch is on the OFF position before connecting to a power source. g) The device is not a toy. Children must be supervised to ensure that they do not play with the device. h) UV radiation is harmful to health. Do not expose eyes and skin to the device operation (UVC radiation).
2.4. Safe device use
a) Do not overload the device. Use the appropriate tools for the given task. A correctly-selected device will perform the task for which it was designed better and in a safer manner. b) Make sure the plug is disconnected from the socket before attempting any adjustments, accessory replacements, or before putting the device aside. Such precautions will reduce the risk of accidentally activating the device. c) Disconnect the device from the power supply before commencement of adjustment, cleaning, and maintenance. Such a preventive measure reduces the risk of accidental activation. d) When not in use, store in a safe place, away from children and people not familiar with the device who have not read the user manual. The device may pose a hazard in the hands of inexperienced users. e) Keep the device in perfect technical condition. Before each use, check for general damage and especially check for cracked parts or elements and for any other conditions which may impact the safe operation of the device. If damage is discovered, hand over the device for repair before use. f) Device repair or maintenance should be carried out by qualified persons, only using original spare parts. This will ensure safe use. g) To ensure the operational integrity of the device, do not remove factory-fitted guards and do not loosen any screws. h) Do not move, adjust, or rotate the device in the course of work. i) Clean the device regularly to prevent stubborn grime from accumulating. j) The device is not a toy. Cleaning and maintenance may not be carried out by children without supervision by an adult person.
k) It is forbidden to interfere with the structure of the device in order to change its parameters or construction.

ATTENTION! Despite the safe design of the device and its protective features, and despite the use of additional elements protecting the operator, there is still a slight risk of accident or injury when using the device. Stay alert and use common sense when using the device.
3. Use guidelines
The product is intended for sterilisation of knives. The appliance should be fixed vertical to the wall using the holes on the back of the casing.
The product is outside the scope of MDD93/42/EEC regulations for medical devices.
The user is liable for any damage resulting from unintended use of the device.
3.1. Device description

- Protective plate
- Reinforcement
- Casing
- Timer
- Switch
- LEDs
- UV-lamp
- Hinge
- Door
- Handle
- Magnetic lock
- Clamp
- Power cable
3.2. Preparing for use
APPLIANCE LOCATION
The temperature of environment must not be higher than 40° C and the relative humidity should be less than 85%. Ensure good ventilation in the room in which the device is being used. The device should always be used when positioned on an vertical, even, stable, clean, fireproof and dry surface, and be out of the reach of children and persons with limited mental and sensory functions. Position the device such that you always have access to the power plug. The power cord connected to the appliance must be properly grounded and correspond to the technical details on the product label.
3.3. Assembling the device
The device should be fixed to the wall using the holes on the back of the casing.
3.4. Device use
NOTE: the safety switch turns off the lamps when the appliance door is opened. The device must be used in an upright position regardless where it has been installed.
USAGE
When you have cleaned the knives, place them inside the device on a magnetic lamp and select a time from 0 to 1 hour on the knob. Both green and red LEDs will light. The green light informs about the working time of the device, while the red light about power supply the device. After the set operation time is over, the LEDs will turn off and the knives will be ready for use.
3.5. Cleaning and maintenance
a) Unplug the mains plug and allow the device to cool completely before each cleaning, adjustment or replacement of accessories, or if the device is not being used. - Wait for the rotating elements to stop. b) Always unplug the device before cleaning or putting it away. c) Use only non-corrosive cleaners to clean the surface. d) Use only mild, food-safe detergents to wash the device. e) After cleaning the device, all parts should be dried completely before using it again. f) Store the unit in a dry, cool place, free from moisture and direct exposure to sunlight. g) Do not spray the device with a water jet or submerge it in water. h) Do not allow water to get inside the device through vents in the housing of the device. i) Clean the vents with a brush and compressed air. j) The device must be regularly inspected to check its technical efficiency and spot any damage. k) Use a soft cloth for cleaning. I) Do not leave the battery in the device if it will not be used for a longer period of time. m) Use a soft, damp cloth for cleaning. n) Do not use sharp and/or metal objects for cleaning (e.g. a wire brush or a metal spatula) because they may damage the surface material of the appliance. o) Do not clean the device with an acidic substance, agents of medical purposes, thinners, fuel, oils or other chemical substances because it may damage the device. p) Lamps should be replaced once a year.
3.5.1 Lamp replacement
Before you start replacing the lamps, disconnect the device from the power supply, remove it from the wall and place it on a flat surface. Then, unscrew the lamp and replace it.
CAUTION: under no circumstances should you expose your eyes to ultraviolet light without eye protection!
DISPOSING OF USED DEVICES:
Do not dispose of this device in municipal waste systems. Hand it over to an electric and electrical device recycling and collection point. Check the symbol on the product, instruction manual and packaging. The
plastics used to construct the device can be recycled in accordance with their markings. By choosing to recycle you are making a significant contribution to the protection of our environment.
Contact local authorities for information on your local recycling facility.

- Switch
- LEDs
- UV lamp
- Hinge
- Door
- Handle
- Magnetic lock
- Clamp
- Power cord
LOCATION OF THE DEVICE
- Protective plate
- Reinforcement
- Housing
- Timer
- Switch
- LEDs
- UV lamp
- Hinge
- Door
- Handle
- Magnetic lock
- Clamp
- Power cable
PLACEMENT OF THE APPLIANCE
- Protective plate
- Reinforcement
- Housing
- Timer
- Switch
- LED diodes
- UV lamp
- Hinge
- Door
- Handle
- Magnetic lock
- Clamp
- Power cord
3.2. Preparation for use
POSITION OF THE APPLIANCE
The ambient temperature must not exceed 40°C, and the relative air humidity must be less than 85%. Ensure good ventilation in the room where the device is used. The device should always be used placed on a vertical, flat, stable, clean, fire-resistant, and dry surface, and kept out of reach of children and persons with limited mental and sensory functions. Position the device so that you always have access to the plug. The power cord connected to the device must be properly grounded and match the technical specifications on the product label.
3.3. Assembling the device
Environmental and disposal information
Producer to customer
Dear Sir or Madam,
Let's take care of the environment! The product you own should not be disposed of with household waste. According to applicable regulations (Directive 2012/19/EU and other local regulations), used equipment must be taken to designated collection points for proper disposal and recycling.

How to Handle the Product at the End of Its Lifecycle?
- Electrical and Electronic Equipment: Products marked with the crossed-out wheeled bin symbol must not be disposed of with household waste. You can:
Take it to your local collection point for electrical and electronic equipment. Use the “one-for-one” system (returning the old device when purchasing a new one, if available in your region).
- Batteries and Accumulators: If the product contains batteries, remove them before recycling and take them to designated battery collection points.
- Packaging Materials: Packaging, such as cardboard or plastic, should be sorted and placed in recycling bins.
Why is This Important?
Proper disposal of equipment and packaging materials:
- Protects the environment from harmful substances.
- Enables the recovery of valuable resources.
- Reduces the amount of waste sent to landfills.
Where to Find Information?
Information about waste collection points can be found on local authorities' websites or through your recycling service provider. If needed, contact our customer service team, who will gladly provide further details.
Thank you for your care for the environment and commitment to recycling!
Contact
expondo Polska sp. z o.o. sp. k.